Вы находитесь на странице: 1из 82

HYDRAULIC ANALYSIS OF REINFORCED CONCRETE BOX CULVERT

STA. 3+329.00
» Remove / Replace Existing 1-3.00m. X 2.00m. X 6.00m. Box Culvert

Existing RCBC Dimension:


L = 1.00 m
W = 1.00 m
H = 1.00 m
CiA
Q(Run - Off) = 362
Given:
C = 0.40
i = 100 mm./hr.
A = 100 hectares (assumed)

Q(Run - Off) = 11.05 m3/s


1
Q(RCBC) = n (A) (R)2/3 (S)1/2
Given:
S = 0.01
n = 0.08 (for trees within channel)
A
R = P
Assume, ( Box Culvert Fully Submerged)
A = HxW
W = 2 H,
A = 2H2

P = 2H + W
W=2H ,
P = 4H

2H2
R = 4H
H
R = 2
Substitute Values for,

Q(Run - Off) = Q(RCBC)


1
11.05 = 0.08 (2H2) (H/2)2/3 (0.01)1/2
H =
2.08 m.
W = 2H
W = 4.15 m.
Designed RCBC Dimension = 2.08 m. x 4.15 m.
Area of Designed RCBC = 8.62 m2
Area of Existing RCBC = 1.00 m. x 1.00 m.
Area of Existing RCBC = 1.00 m2

Therefore: NOT SAFE, Area of Designed RCBC>Area of Existing RCBC

THEREFORE, Area of Designed RCBC ≤ Area of Existing RCBC, SAFE.


HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 0+16.70
» Repair / Rehab. of Existing 1-0.910m. Ø x 4.00 m. RCPC
» Additional 1-0.910m. Ø x 4.00 m. RCPC

Runoff Discharge

CiA Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 2.00


160
Q =
362

Q = 0.44198895 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY :


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.4331114 m or 433.11 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.91 m
A = 0.6504 m²
MANNING'S = 0.050 Fairly Regular Section (some grass and
COEFFECIENT
(n) weeds, little or no brush)
S = 0.010
Pwet = 2.8589 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.48476 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.


HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 1+215.00
» Remove / Replace Existing 1-0.610m. Ø x 5.00 m. RCPC to 1-0.910m. Ø x 8.00 m. RCPC

Runoff Discharge

CiA Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 2.00


160
Q =
362

Q = 0.44198895 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.4 m or 433.11 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.91 m
A = 0.6504 m²
MANNING'S Fairly Regular Section (some grass and
COEFFECIENT = 0.050
(n) weeds, little or no brush)
S = 0.010
Pwet = 2.8589 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.48476 m³/sec
Remarks: SAFE Qrunoff < Qdischarge
THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 1+383.00
» Remove / Replace Existing 1-0.610m. Ø x 10.00 m. RCPC (Skewed)
to 1-0.910m. Ø x 11.00 m. RCPC

Runoff Discharge

CiA Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.30


104
Q =
362

Q = 0.28729282 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.3 m or 349.19 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.91 m
A = 0.6504 m²
MANNING'S
COEFFECIENT = 0.08 Some Weeds, Dense Trees
(n)
S = 0.010
Pwet = 2.8589 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.30297 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 1+770.00
» Remove / Replace Existing 2-0.610m. Ø x 6.50 m. RCPC to 1-0.910m. Ø x 8.00 m. RCPC

Runoff Discharge

CiA Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.91 m
A = 0.6504 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 2.8589 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)
Q = 0.44069 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 2+224.00
» Remove / Replace Existing 2-0.610m. Ø x 5.20 m. RCPC to 1-0.910m. Ø x 8.00 m. RCPC

Runoff Discharge

CiA Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.50


120
Q =
362

Q = 0.33149171 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)

D= 0.375085488 m or 375.09 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.91 m
A = 0.6504 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 2.8589 m (assumed Fully Submerged)
�/�𝑤𝑒�
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.44069 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 2+252.00
» Remove / Replace Existing 2-0.610m. Ø x 5.00 m. RCPC to 1-0.910m. Ø x 8.00 m. RCPC

Runoff Discharge

CiA Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.50


120
Q =
362

Q = 0.33149171 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.375085488 m or 375.09 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.91 m
A = 0.6504 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 2.8589 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.44069 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 2+485.10
» Remove / Replace Existing 1-0.610m. Ø x 5.20 m. RCPC (Skewed)
to 1-0.910m. Ø x 11.00 m. RCPC (Skewed)

Runoff Discharge

CiA Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)

D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.91 m
A = 0.6504 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 2.8589 m (assumed Fully Submerged)
R = �/�𝑤𝑒�
𝑄= 1/𝑛 �𝑅^(2/3)
𝑆^(1/2)
Q = 0.44069 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 2+887.20
» Remove / Replace Existing 1-0.310m. Ø x 6.50 m. RCPC (Skewed)
to 1-0.910m. Ø x 11.00 m. RCPC (Skewed)

Runoff Discharge

CiA Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)

D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.91 m
A = 0.6504 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 2.8589 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.44069 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 3+390.00
» Remove / Replace Existing 1-0.610m. Ø x 7.00 m. RCPC (Skewed)
to 1-0.910m. Ø x 11.00 m. RCPC (Skewed)

Runoff Discharge

CiA Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)

D= 0.422144789 m or 422.14 mm < 910 mm


Check for RCPC Discharge :
RCPC DATA
D = 0.91 m
A = 0.6504 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 2.8589 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.44069 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 3+470.00
» Remove / Replace Existing 1-0.610m. Ø x 7.00 m. RCPC (Skewed)
to 1-0.910m. Ø x 11.00 m. RCPC (Skewed)

Runoff Discharge

CiA Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø


�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.91 m
A = 0.6504 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 2.8589 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.44069 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 4+084.00
» Remove / Replace Existing 1-0.610m. Ø x 7.00 m. RCPC
to 1-0.910m. Ø x 8.00 m. RCPC

Runoff Discharge

CiA Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.91 m
A = 0.6504 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 2.8589 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.44069 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 4+352.00
» Remove / Replace Existing 1-0.610m. Ø x 6.00 m. RCPC (Skewed)
to 1-0.910m. Ø x 11.00 m. RCPC (Skewed)

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)

D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 4+468.50
» Remove / Replace Existing 1-0.310m. Ø x 4.00 m. RCPC to 1-0.910m. Ø x 8.00 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec
USE MAXIMUM AVERAGE BARREL VELOCITY
V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 4+571.00
» Remove / Replace Existing 1-0.310m. Ø x 7.00 m. RCPC (Skewed)
to 1-0.910m. Ø x 11.00 m. RCPC (Skewed)

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362
Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 4+652.90
» Remove / Replace Existing 1-0.610m. Ø x 7.70 m. RCPC to 1-0.910m. Ø x 8.00 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 4+727.70
» Remove / Replace Existing 1-0.610m. Ø x 7.80 m. RCPC (Skewed)
to 1-0.910m. Ø x 11.00 m. RCPC (Skewed)

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)
0.40 200.00 1.90
152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 5+155.00
» Remove / Replace Existing 1-0.610m. Ø x 6.80 m. RCPC to 1-0.910m. Ø x 8.00 m. RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 5+260.00
» Remove / Replace Existing 1-0.610m. Ø x 6.00 m. RCPC to 1-0.910m. Ø x 8.00 m. RCPC
Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 6+093.00
» Remove / Replace Existing 1-0.210m. Ø x 6.10 m. RCPC to 1-0.910m. Ø x 8.00 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)
STA. 6+420.00
» Repair / Rehab. of Existing 1-0.910m. Ø x 5.00 m. RCPC
» Additional 1-0.910m. Ø x 3.00 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.


HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 6+524.00
» Remove / Replace Existing 4-0.710m. Ø x 4.20 m. RCPC
to 3-0.910m. Ø x 8.00 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 12.00


960
Q =
362

Q = 2.65193370 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 1.060901969 m or 1060.90 mm > 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.91 m
A = 0.6504 m²
Total Area = 1.9512 m² for 3 barrel RCPC
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 2.8589 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 2.75001 m³/sec
Remarks: SAFE Qrunoff < Qdischarge
THEREFORE: Adopt a 3-0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 7+180.00
» Remove / Replace Existing 1-0.610m. Ø x 5.00 m. RCPC to 1-0.910m. Ø x 8.00 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge
THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 7+987.00
» No Improvement of Existing 1-1.10m. Ø x 8.00 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 1.10 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 8+564.00
» Repair / Rehab. of Existing 1-1.10m. Ø x 6.00 m. RCPC
» Additional 1-1.10m. Ø x 2.00 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 1.10 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�
�/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 8+931.00
» Repair / Rehab. of Existing 1-1.10m. Ø x 5.00 m. RCPC (Skewed)
» Additional 1-1.10m. Ø x 6.00 m. RCPC (Skewed)

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 1.10 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 9+459.00
» Remove / Replace Existing 1-0.610m. Ø x 5.50 m. RCPC (Skewed)
to 1-0.910m. Ø x 11.00 m. RCPC (Skewed)

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 9+522.00
» Remove / Replace Existing 1-0.610m. Ø x 5.00 m. RCPC
to 1-0.910m. Ø x 8.00 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 9+704.00
» Repair / Rehab of Existing 1-1.210m. Ø x 3.60 m. RCPC
» Additional 1-1.210m. Ø x 4.40 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 1.210 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 9+826.00
» Repair / Rehab of Existing 1-1.210m. Ø x 4.00 m. RCPC
» Additional 1-1.210m. Ø x 4.00 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 1.210 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm
Check for RCPC Discharge :
RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 10+058.00
» Repair / Rehab of Existing 1-1.10m. Ø x 5.00 m. RCPC
» Additional 1-1.10m. Ø x 3.00 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 1.10 m. Ø

�=√(4𝑄/𝜋𝑉)
�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 10+574.00
» Remove / Replace Existing 2-0.610m. Ø x 6.00 m. RCPC (Skewed)
to 1-0.910m. Ø x 11.00 m. RCPC (Skewed)

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 10+640.00
» Remove / Replace Existing 1-0.310m. Ø x 5.50 m. RCPC
to 1-0.910m. Ø x 8.00 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 10+857.00
» Remove / Replace Existing 1-0.610m. Ø x 6.00 m. RCPC
to 1-0.910m. Ø x 11.00 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec
USE MAXIMUM AVERAGE BARREL VELOCITY
V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 11+147.00
» Repair / Rehab. of Existing 1-1.10m. Ø x 4.00 m. RCPC
» Additional 1-1.10m. Ø x 4.00 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362
Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 1.10 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 11+356.00
» Remove / Replace Existing 1-0.610m. Ø x 4.00 m. RCPC
to 1-0.910m. Ø x 8.00 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 11+357.00
» Repair / Rehab. of Existing 1-1.10m. Ø x 4.00 m. RCPC
» Additional 1-1.10m. Ø x 4.00 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)
0.40 200.00 1.90
152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 1.10 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 12+023.00
» Repair / Rehab. of Existing 1-1.10m. Ø x 7.50 m. RCPC
» Additional 1-1.10m. Ø x 0.50 m. RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 1.10 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 12+205.00
» Repair / Rehab. of Existing 1-1.10m. Ø x 7.80 m. RCPC
» Additional 1-1.10m. Ø x 0.20 m. RCPC
Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 1.10 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 12+683.00
» Remove / Replace Existing 2-0.610m. Ø x 11.70 m. RCPC (Skewed)
to 1-0.910m. Ø x 11.00 m. RCPC (Skewed)

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)
STA. 12+872.50
» No Improvement of Existing 2-1.10m. Ø x 11.50 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


152
Q =
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 1.10 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.422144789 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.


HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 12+900.00
» No Improvement of Existing 3-1.10m. Ø x 11.50 m. RCPC (Skewed)

Runoff Discharge

Q = C i A Runoff Coeffecient Ave. Rainfall Intensity Area


362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


Q = 152
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 1.10 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.4 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
A = 1.1499 m²
MANNING'S = 0.055 Cultivated Land, Field Crops
COEFFECIENT
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.


HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 13+052.80
» No Improvement of Existing 2-1.10m. Ø x 11.00 m. RCPC (Skewed)

Runoff Discharge

Q = C i A Runoff Coeffecient Ave. Rainfall Intensity Area


362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


Q = 152
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 1.10 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.4 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
MAN
NING
A = 1.1499 m²
'S
COEF = Cultivated
0.055 Land, Field Crops
FECIE
NT
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge
THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 13+210.00
» Repair / Rehab. of Existing 2-1.10m. Ø x 10.00 m. RCPC (Skewed)
» Additional 2-1.10m. Ø x 2.00 m. RCPC (Skewed)

Runoff Discharge

Q = C i A Runoff Coeffecient Ave. Rainfall Intensity Area


362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


Q = 152
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 1.10 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.4 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
MAN
NING
A = 1.1499 m²
'S
COEF = Cultivated
0.055 Land, Field Crops
FECIE
NT
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 13+390.00
» No Improvement of Existing 1-1.10m. Ø x 8.50 m. RCPC

Runoff Discharge

Q = C i A Runoff Coeffecient Ave. Rainfall Intensity Area


362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


Q = 152
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 1.10 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.4 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
MAN
NING
A = 1.1499 m²
'S
COEF = Cultivated
0.055 Land, Field Crops
FECIE
NT
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�
�/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 13+730.50
» Repair / Rehab. of Existing 1-1.10m. Ø x 7.10 m. RCPC
» Additional 1-1.10m. Ø x 0.90 m. RCPC

Runoff Discharge

Q = C i A Runoff Coeffecient Ave. Rainfall Intensity Area


362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


Q = 152
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 1.10 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.4 m or 422.14 mm < 1100 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.10 m
MAN
NING
A = 0.9503 m²
'S
COEF = Cultivated
0.055 Land, Field Crops
FECIE
NT
(n)
S = 0.010
Pwet = 3.4558 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.73069 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 1.10mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 13+930.50
» Remove / Replace of Existing 2-0.310m. Ø x 6.00 m. RCPC (Skewed)
to 1-0.910m. Ø x 12.00 m. RCPC (Skewed)

Runoff Discharge

Q = C i A Runoff Coeffecient Ave. Rainfall Intensity Area


362 (C) ( i ) mm/hr (hectares)

0.40 200.00 1.90


Q = 152
362

Q = 0.41988950 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.4 m or 422.14 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 1.21 m
MAN
NING
A = 1.1499 m²
'S
COEF = Cultivated
0.055 Land, Field Crops
FECIE
NT
(n)
S = 0.010
Pwet = 3.8013 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.94214 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.


HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 3+374.00 TO STA. 3+380.00 (Right Side)


» Installation of 1-0.610m. Ø x 6.00m. RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.65


52
Q =
362

Q = 0.14364641 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :

�=√(4𝑄/𝜋𝑉)
D= 0.246911496 m or 246.91 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.


HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 3+802.25 TO STA. 3+805.65 (Right Side)


» Remove/Replace Existing 1-0.410m. Ø x 3.40m. RCPC to 0.610m. Ø RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.65


52
Q =
362

Q = 0.14364641 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :

�=√(4𝑄/𝜋𝑉)
D= 0.246911496 m or 246.91 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.


HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 3+813.30 TO STA. 3+819.10 (Right Side)


» Remove/Replace Existing 1-0.410m. Ø x 5.80m. RCPC to 0.610m. Ø RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.60


48
Q =
362

Q = 0.13259669 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :

�=√(4𝑄/𝜋𝑉)
D= 0.237224892 m or 237.22 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.


HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 3+858.52 TO STA. 3+862.82 (Right Side)


» Repair / Rehab. of Existing 1-0.610m. Ø x 4.30m. RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.65


52
Q =
362

Q = 0.14364641 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :

�=√(4𝑄/𝜋𝑉)
D= 0.246911496 m or 246.91 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.


HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 3+896.90 TO STA. 3+903.10 (Right Side)


» Remove/Replace Existing 0.60m. X 0.60m. x 5.80m. Box Type Concrete with
Cover Canal to 0.610m. Ø RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.65


52
Q =
362

Q = 0.14364641 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :

�=√(4𝑄/𝜋𝑉)
D= 0.246911496 m or 246.91 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610m.Ø RCPC for the drainage.


HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 3+909.15 TO STA. 3+913.80 (Left Side)


» Repair / Rehab. of Existing 1-0.910m. Ø x 4.65m. RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.60


48
Q =
362

Q = 0.13259669 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.910 m. Ø
Check for RCPC Diameter :

�=√(4𝑄/𝜋𝑉)
D= 0.237224892 m or 237.22 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.91 m
A = 0.6504 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 2.8589 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.44069 m³/sec
Remarks: SAFE Qrunoff < Qdischarge
THEREFORE: Adopt a 0.910m.Ø RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 3+919.35 TO STA. 3+923.35 (Right Side)


» Repair / Rehab. of Existing 1-0.610m. Ø x 4.00m. RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.65


52
Q =
362

Q = 0.14364641 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :

�=√(4𝑄/𝜋𝑉)

D= 0.246911496 m or 246.91 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge
THEREFORE: Adopt a 0.610mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 4+006.70 TO STA. 4+009.60 (Left Side)


» Repair / Rehab. of Existing 1-0.910m. Ø x 2.90m. RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.60


48
Q =
362

Q = 0.13259669 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.910 m. Ø
Check for RCPC Diameter :

�=√(4𝑄/𝜋𝑉)
D= 0.237224892 m or 237.22 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.91 m
A = 0.6504 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 2.8589 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.44069 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 4+015.00 TO STA. 4+019.65 (Right Side)


» Repair / Rehab. of Existing 1-0.610m. Ø x 4.65m. RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.60


48
Q =
362

Q = 0.13259669 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :

�=√(4𝑄/𝜋𝑉)

D= 0.237224892 m or 237.22 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 3+025.60 TO STA. 3+026.70


» Repair / Rehab. of Existing 1-0.910m. Ø x 1.10m. RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.60


48
Q =
362

Q = 0.13259669 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :
�=√(4𝑄/𝜋𝑉)

D= 0.237224892 m or 237.22 mm < 910 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.91 m
A = 0.6504 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 2.8589 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3)
𝑆^(1/2)
𝑄= 1/𝑛 �𝑅^(2/3)
𝑆^(1/2)
Q = 0.44069 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.910mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 4+151.40 TO STA. 4+155.40 (Left Side)


» Remove / Replace Existing 1-0.410m. Ø x 4.00m. RCPC to 1-0.610m. Ø RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.60


48
Q =
362

Q = 0.13259669 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :

�=√(4𝑄/𝜋𝑉)
D= 0.237224892 m or 237.22 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�
�/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 4+422.00 TO STA. 4+435.70 (Right Side)


» Remove / Replace Existing 1-0.410m. Ø x 13.70m. RCPC to 1-0.610m. Ø RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.60


48
Q =
362

Q = 0.13259669 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :

�=√(4𝑄/𝜋𝑉)
D= 0.237224892 m or 237.22 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 3+443.00 TO STA. 3+445.10


» Remove / Replace Existing 1-0.410m. Ø x 2.10m. RCPC to 1-0.610m. Ø RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.45


36
Q =
362

Q = 0.09944751 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :
�=√(4𝑄/𝜋𝑉)

D= 0.2054427829 m or 205.44 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3)
𝑆^(1/2)
Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 4+453.15 TO STA. 4+456.30 (Right Side)


» Remove / Replace Existing 1-0.410m. Ø x 3.15m. RCPC to 1-0.610m. Ø RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.60


48
Q =
362

Q = 0.13259669 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :

�=√(4𝑄/𝜋𝑉)
D= 0.237224892 m or 237.22 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 3+471.50 TO STA. 3+473.60


» Remove / Replace Existing 1-0.410m. Ø x 2.10m. RCPC to 1-0.610m. Ø RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.60


48
Q =
362

Q = 0.13259669 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :
�=√(4𝑄/𝜋𝑉)

D= 0.237224892 m or 237.22 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3)
𝑆^(1/2)
Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 4+490.75 TO STA. 4+494.55 (Right Side)


» Repair / Rehab. of Existing 1-0.610m. Ø x 3.80m. RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.65


52
Q =
362

Q = 0.14364641 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :

�=√(4𝑄/𝜋𝑉)

D= 0.246911496 m or 246.91 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 4+591.00 TO STA. 4+594.20 (Right Side)


» Repair / Rehab. of Existing 1-0.610m. Ø x 3.20m. RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.65


52
Q =
362

Q = 0.14364641 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :

�=√(4𝑄/𝜋𝑉)

D= 0.246911496 m or 246.91 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 4+607.80 TO STA. 4+611.00 (Right Side)


» Repair / Rehab. of Existing 1-0.610m. Ø x 3.20m. RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.65


52
Q =
362

Q = 0.14364641 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :

�=√(4𝑄/𝜋𝑉)
D= 0.246911496 m or 246.91 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 4+629.85 TO STA. 4+635.75 (Right Side)


» Repair / Rehab. of Existing 1-0.610m. Ø x 5.90m. RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.60


48
Q =
362

Q = 0.13259669 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :

�=√(4𝑄/𝜋𝑉)

D= 0.237224892 m or 237.22 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 4+660.85 TO STA. 4+662.24


» Repair / Rehab. of Existing 1-0.610m. Ø x 1.40m. RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.65


52
Q =
362

Q = 0.14364641 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.610 m. Ø


�=√(4𝑄/𝜋𝑉)

D= 0.246911496 m or 246.91 mm < 610 mm


Check for RCPC Discharge :
RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3)
𝑆^(1/2)
Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 3+861.60 TO STA. 3+863.10


» Repair / Rehab. of Existing 1-0.610m. Ø x 1.40m. RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.60


48
Q =
362

Q = 0.13259669 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :
�=√(4𝑄/𝜋𝑉)

D= 0.237224892 m or 237.22 mm < 610 mm


Check for RCPC Discharge :
RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3)
𝑆^(1/2)
Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 5+184.73 TO STA. 5+189.73 (Left Side)


» Repair / Rehab. Of Existing 2-1.210m. Ø x 5.00m. RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.60


48
Q =
362

Q = 0.13259669 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :

�=√(4𝑄/𝜋𝑉)
D= 0.237224892 m or 237.22 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 5+418.00 TO STA. 5+422.00 (Left Side)


» Remove / Replace Existing 1-0.410m. Ø x 4.00m. RCPC to 1-0.610m. Ø RCPC

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.60


48
Q =
362

Q = 0.13259669 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :
�=√(4𝑄/𝜋𝑉)
D= 0.237224892 m or 237.22 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3)
𝑆^(1/2)
Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 5+460.00 TO STA. 5+461.00 (Left side)


» Retain / No Improvement of Existing 2-1.00m. X 1.00m. X 1.00m. Box Type
Irrigation Gate Canal (Drop)

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.65


52
Q =
362

Q = 0.14364641 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :
�=√(4𝑄/𝜋𝑉)

D= 0.246911496 m or 246.91 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.

HYDRAULIC ANALYSIS
(LATERAL DRAIN)

STA. 5+480.00 TO STA. 5+482.00 (Left side)


» Retain / No Improvement of Existing Water Gate Canal (N.I.A.)

Runoff Discharge
C i A Runoff Coeffecient Ave. Rainfall Intensity Area
Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 0.65


52
Q =
362

Q = 0.14364641 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s
D = 0.610 m. Ø
Check for RCPC Diameter :
�=√(4𝑄/𝜋𝑉)

D= 0.246911496 m or 246.91 mm < 610 mm

Check for RCPC Discharge :


RCPC DATA
D = 0.61 m
A = 0.2922 m²
MANNING'S
COEFFECIENT = 0.055 Cultivated Land, Field Crops
(n)
S = 0.010
Pwet = 1.9164 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Q = 0.15167 m³/sec
Remarks: SAFE Qrunoff < Qdischarge

THEREFORE: Adopt a 0.610mØ RCPC for the drainage.


HYDRAULIC ANALYSIS FOR LINE DITCH CANAL

STA. 5+187.00 TO STA. 5+334.00


RUNOFF DISCHARGE

Runoff Coeffecient Ave. Rainfall Intensity Area


(C) ( i ) mm/hr (hectares)
0.40 200.00 1.65

Q = CiA
362

Q = 132
362

Q = 0.365 m³/sec

𝑄 = 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Data:
use n = 0.015
R^(2/3)= A/P
S^(1/2)= 1/100 P=2HX2W
d= 0.60 d= 0.50 m
W= 0.40 m
P= 0.20 m

R^(2/3)= 0.45
S= 0.01

𝑄 = 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

2/3 1/2
0.36 = 1.00 0.50
0.50 0.01
0.015 0.50 + 2d

Q(RUNOFF) =Q(RCPC)

0.36 ≤ 0.36 m³/s


safe
HYDRAULIC ANALYSIS FOR LINE DITCH CANAL

STA. 5+344.50 TO STA. 5+384.50


RUNOFF DISCHARGE

Runoff Coeffecient Ave. Rainfall Intensity Area


(C) ( i ) mm/hr (hectares)
0.40 200.00 0.60

Q = CiA
362

Q = 48
362

Q = 0.133 m³/sec

𝑄 = 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

Data:
use n = 0.015
R^(2/3)= A/P
S^(1/2)= 1/100 P=2HX2W
d= 0.60 d= 0.30 m
W= 0.30 m
P= 0.09 m

R^(2/3)= 0.26
S= 0.01

𝑄 = 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)

2/3 1/2
0.13 = 1.00 0.50
0.50 0.01
0.015 0.50 + 2d

Q(RUNOFF) =Q(RCPC)

0.13 ≤ 0.13 m³/s


safe
HYDRAULIC ANALYSIS
(CROSS PIPES)

STA. 6+524.00
» Remove / Replace Existing 4-0.710m. Ø x 4.20 m. RCPC
to 3-0.910m. Ø x 8.00 m. RCPC

Runoff Discharge

C i A Runoff Coeffecient Ave. Rainfall Intensity Area


Q =
362 (C) ( i ) mm/hr (hectares)

0.40 200.00 2.00


160
Q =
362

Q = 0.44198895 m³/sec

USE MAXIMUM AVERAGE BARREL VELOCITY


V = 3.00 m/s

Check for RCPC Diameter : D = 0.910 m. Ø

�=√(4𝑄/𝜋𝑉)
D= 0.4331114152 m or 433.11 mm < 910 mm
Check for RCPC Discharge :
RCPC DATA
D = 0.91 m
A = 0.6504 m²
MANNING'S
COEFFECIENT (n) = 0.055 Cultivated Land, Field Crops

S = 0.010
Pwet = 2.8589 m (assumed Fully Submerged)
R = �/�𝑤𝑒�

𝑄= 1/𝑛 �𝑅^(2/3) 𝑆^(1/2)


Q = 0.4407 m³/sec
Remarks: NOT SAFE Qrunoff > Qdischarge

THEREFORE: Adopt a 3-0.910mØ RCPC for the drainage.


1 0.035Flood Plains (Pasture, Short Grass, No Brush)

0.050 Fairly Regular Section (some grass and


2 weeds, little or no brush)

3 0.08
Some Weeds, Dense Trees

4 0.055 Cultivated Land, Field Crops

5 0.16 Wooded

6 0.05 Some Weeds, Lights Brush on Banks

Area (1-Barrel Cross Pipe,0.71mØ)= 0.40 m²


Area (4-Barrel Cross Pipe,0.71mØ)= 1.58 m²
Area (3-Barrel Cross Pipe,0.91mØ)= 1.95 m²

Area (4-Barrel Cross Pipe,0.71mØ) No. of


=
Area (4-Barrel Cross Pipe,0.91mØ) RCPC
1.58
= 3 Barrel - 0.910m. Ø RCPC
0.65

Q(4-Barrel Cross Pipe,0.71mØ) = 3.91216 m³/sec

Q(3-Barrel Cross Pipe,0.91mØ) = 5.53939 m³/sec