SOIL FILLING
Supply of any approved type of soil in approved borrow area by
mechanical means loading into and transportation by mechanical means
and unloading the soil within initial lead of 10 kms on properly prepared and
scientifically approved surface including spreading and levelling the earth in
22.5 cm layers to make ready for watering and compaction with Earth
rammer/Vibro Rollor for all heights including
construction,maintenance,watering, testing and lightening of haul road and
borrow area etc complete as per the direction of engineer-in-charge.(Earth
to be arranged by agency)
ANTI-CARBONATION COATING
Providing and Applying of three coats of high build micro porous anti-
carbonation coating over a coat of primer to exposed concrete surface of
Pier, Pier cap, pedestal, soffit & sides of segmental girders of viaduct,
Railway span and Double Decker spine segment , cantilever arm & crash
barriers sides ,with excellent resistance to attack by carbon-dioxide, air
borne chlorides, acid rain with exceptional weathering characteristics as per
manufacturer specification, including cost of all materials, conveyance ,
royalties and taxes, loading and unloading, labour,sundries, T&P
etc.completed as direction of Engineer In Charge. Make: Primer-Sikagard®-
552 W Aquaprimer or equivalent, Anti Carbonation coat-Sikagard®-550 W
Elastic or equivalent
REMOVING VEGETATION FROM CONCRETE STRUCTURE
Removing vegetation by uprooting stumps and disposal of rubbish including
chipping and cleaning the area, applying two coat of epoxy bonding agent,
filling the area with high strength microconcrete, including cost of all
materials, scaffolding, conveyance , royalties and taxes, loading and
unloading, labour,sundries, T&P etc.completed as direction of Engineer In
Charge. complete at all levels and locations and as directed. Make:
Bonding Agent - Nitobond EP, Micro Concrete - Renderoc LAXtra.
WEATHER COAT
Painting two coats with Water soluble weather coat emulsion paint
(Conforming to IS 15489 Type 2) of approved shade of approved make
over out side brick wall over a coat of primer,and a coat of cement paint on
surface of new walls after scraping, cleaning the surface inclusive of cost of
waterproofing cement paint and primer and also including all cost of
materials, scaffolding, labour, watering & curing T&P etc complete as per
direction of Engineer -in-charge.
MIRROR POLISHING
Mirror polishing on marble work/Granite work/stone work where ever
required to give high gloss finish complete. including all cost of materials,
scaffolding, labour, watering & curing T&P etc complete as per direction of
Engineer -in-charge.
MARBLE FLOORING
Providing and laying Mirror polished White Marble Flooring in floor Using 18
mm thick approved size with residue and skirting as per the Approved
Pattern and Drawing on 20 mm thick cement mortar 1:3 ( 1cement : 3
coarse sand)with Neat White cement slurry on top of bedding , Including
filling joints with floating white cement slurry, Nosing, Mirror Polishing, Anti
slip treatment Etc. all Complete. All work inclusive of all taxes,
transportation, wastage, protection coverings etc. All mortar dropping shall
be cleaned by wet jute brush immediately after completing masonry work to
show clean stones in elevation before closing day's work. Based on basic
plans, elevations & sections of temple provided by the EIC, the contractor
shall submit detailed final execution Autocad drawings applicable to all
stone works for the temple to EIC for their approval before issuing the same
for execution. The drawings would include all elements and ornamentation
work based on tender items applicable to all stone works for the temple.
GRANULAR SUB-BASE
Providing and laying of granular sub-base by providing close graded
Material conforming to specifications, mixing in a mechanical mix plant at
OMC, carriage of mixed material by tippers to work site, for all leads & lifts,
spreading in layers of specified 200mm thickness with motor grader on
prepared surface, watering and compacting with vibratory power roller of 8
to 12 tonne to achieve the 98% of the maximum dry density (Modified
proctor density). With material conforming to Grade-I (size range 75 mm to
0.075 mm) having CBR Value-30. confirming Table 400-1 & Table 400-2 of
MORTH. complete as per specifications and directions of Engineer-in-
Charge.
WMM
Providing, laying, spreading and compacting graded stone aggregate
(Grading II) to wet mix macadam (WMM) conforming to IRC 109 including
premixing the material with water at OMC in for all leads & lifts, laying in
200mm layers with mechanical paver finisher in sub- base / base course on
well prepared surface and compacting with vibratory roller of 8 to 10 tonne
capacity to achieve the 98% of Maximum dry density(Modified proctor
density). complete as per specifications and directions of Engineer-in-
Charge.
BITUMINOUS CONCRETE
Providing and laying Bituminous concrete using crushed stone aggregates
of Grade 2 confirming to IRC 111, premixed with bituminous binder and
filler, transporting the hot mix to work site by tippers, laying with paver
finisher equiped with electronic sensor to the required grade, level and
alignment and rolling with smooth wheeled, vibratory and tandem rollers to
achieve the desired compaction and density as per specification, Cold
rolling complete and as per directions of Engineer-in-Charge.
30 mm compacted
thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of
total mix) and Mineral filler @ 3% (percentage by weight of Aggregate)
prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
SEAL COAT
Providing and laying close graded premix surfacing (seal coat) of Type A
Grade confirming to IRC SP 78, fine aggregate shall be 0.27 cum and
binder(VG30 garde) for premixing shall be 22.0 kg per 10 Sqm area for
carpet thickness of 20 mm, including rolling and finishing with road roller all
complete as per direction of Engineer in Charge.
ROAD GULLY CHAMBER
Constructing brick masonry road gully chamber 500x300x450 mm with
bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including
excavation, inside 1: 4 plastering, 500x300mm size MS flat grating cover
with MS angle frame , fixing arrangement, etc., complete as per approved
drawing & Engineer In Charge.
MANHOLE
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4
coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand
: 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8
mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal
size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3
coarse sand) finished with floating coat of neat cement and making
channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate 20 mm nominal size) finished with a floating coat of neat
cement complete as per standard design & direction of Engineer in charge.
Fly ash Bricks of class designation 7.5. A) Inside size 120x90 cm and 90
cm deep including C.I. cover with frame (medium duty) 500 mm internal
diameter, total weight of cover and frame to be not less than 116 kg (weight
of cover 58 kg and weight of frame 58 kg) :
FIXING WINDOWS
Fixing Windows in existing opening including embedding in partition walls
by cutting, assembly, welding, jointing, building up new sections, cost of
SS/MS fasteners (nuts, bolts and washers) etc. and making good the
damages to partition walls as required complete, including cleaning before
and after assembly, disposal of rubbish to the dumping ground, all complete
as per directions of Engineer-In-Charge.
HAND SHOWER
Providing and fixing Hand Shower ( Health Fucet ) with 1 m long PVC tube
and wall hook complete including painting of fittings and brackets, cutting
and making good the walls and floors wherever required including all cost of
labour, material, conveyance, royality, loading, unloading, T&P etc. all
complete as per the direction of Engineer-incharge.
URINAL
Providing and fixing white vitreous china flat back or wall type lipped front
urinal of 710X480X300 mm sizes respectively with standard flush pipe
and CP brush spreders with brush unions and GI clamps complete,
including painting of fittings and brackets, cutting and making good the
walls and floors wherever required & automatic concealed urinal flush of
jaquar make.including all cost of labour, material, conveyance, loading,
unloading, T&P etc. all complete as per the direction of Engineer-in-charge.
SS SINK
Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS:
13983 with C.I. brackets and stainless steel plug 40 mm, including painting
of fittings and brackets, cutting and making good the walls wherever
required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
wherever required with provision for Sink cock with approved make and
model, Including the cost of Sink cock, including all cost of labour, material,
conveyance, loading, unloading, T&P etc. all complete as per the direction
of Engineer-in-charge
STEEL WORKS
Supplying, fabrication and erection of steel structure work, including all
temporary staging and supporting work and making all structural steel work
in accordance with the approved drawing for trusses, purlins, girders,
brackets, etc. with connections using plates, channels and angles, gusset
plate, foundation bolt, cleats, fasteners etc., steel conforming to IS 226 and
IS 2062 with minimum yield strength of 250Mpa.The rate of steel work shall
include assembly, welding, jointing, building up new sections, cost of
fasteners (nuts, bolts and washers) etc. The rate shall also include one coat
zinc rich primer & two coat of Synthetic enamel paint of approved shade
after properly cleaning the steel surface, necessary bolts & washers for
fixing including grouting of bolts with 1:3 non shrink cement grout etc.,
complete all as per drawings, specifications etc. with all lead & lift for all
materials & labour and as direction of the Enineer in Incharge at all heights
& locations
SS HANDRAIL
Supply, fabrication and erection of Handrail with bruch finish Stainless steel
( grade 304) of 50mm dia pipe, Square/round bar, channels, plates etc.,
including welding , grinding, buffing, polishing and making curvature and
fitting the same with necessary stainless steel nuts & bolts complete. i/c
fixing the rail and gate with necessary accessories & stainless steel bolts
ets., of required size(as per approved drawing) on top of the floor or side of
waist slab with suitable arrangement as per approval of Engineer In charge.
For payments purpose only weight of stainless steel members shall be
considered including fixing accessories such as nuts, bolts, fasteners,
plates, locking arrangements etc., complete all as per approved drawings,
specifications etc. with all lead & lift for all materials & labour and as
direction of the Engineer in charge at all heights & locations
ROOLING SHUTTER
Supply, fabrication and fixing of MS rolling shutter of the following
specifications including grill window of 300 mm height at eye level for
visibility even in closed position. Code: Conforming to IS 6248 - 1979 Type:
Self Coiling type (manual) Curtains: Interlocking cold rolled lath section of
0.8 mm thickness. Lock plate : MS sheet of 3.15 mm thick reinforced with
MS angles of 35 x 35 mm. Guide channel : MS sheets of 3.5 mm thick
Bracket Plate : MS Sheet of 0.9 mm thick.Hood Covers : MS sheet of 0.9
mm thick Locking handle : To be provided suitably. Rate shall include
providing and fixing holdfasts and painting two coats of enamel paint of
approved make and shade over two coats of zinc phosphate primer. Shutter
up to 10 SQM -push pull type hand operated with ball bearings , For 10
SQM upto 30 SQM- Mechanical operated gear type with ball bearing, a
pulling hook shall be provided for each of the rolling shutter
WATER PUMP
Dewatering Water Pump with constant pressure water supply of average
discharge pressure comprising of horizontal or vertical mounted, single
outlet, centrifugal stainless steel, & variable speed. Each Pump having a
capacity of minimum 200 Lpm @ 15 m head with cast iron casing, stainless
steel impeller, Stainless steel shaft and electric motor operating on 3 phase,
AL supply of 415V. The pumps to be installed in the pump room and will
have negative suction. Each Pump shall be controlled with Auto switch
connected to the controlled panel. Necessary cabling for Power and control
having a total length of about 20 Rmt shall be laid for auto control. The
installation shall include suction pipe from the pump to the water tank. This
suction pipe, shall be fitted to the foot valve. They will be one size higher
than the pipe suction diameter. The quoted price shall be inclusive of the
Foot Valve, Suction pipe, Installation of pump, Suction valve and strainer
and discharge NRV and valve and Pressure Vessels . The Pump, shall be
approved Make having 2.2 KW of motor. There shall be seperate Electrical
Feeder provided for each pump. The starter electrical panel with all
protection and Amp Meter / Volt Meter / Auto Manual selector shall be in the
scope of the supplier. Complete as per direction of Engineer In Charge.
60 KG RAIL
Providing & fixing of 60 KG rails with approved plates damps,railed tracks
with all necessary fittings & fixtures on existing sleepers at any density,
linking the rails with fish plates and fastenings, levelling & gauging Clamps
all completes as per the drawing & railway specification including cost of
rails,all fixtures, welding, Drilling, cutting all leads and lifts complete as per
direction Engineer In Charge.
EXHAUST FAN
Supply, Installation, Testing, and commissioning of Exhaust fan of size 250
mm sweep, 300mm dia suitable to work on 230/ 250 volts, 50HZ complete
with mounting frame and louvers including making the hole to suit the size
of above fan, making good the damage, connections, with 1.5 sq.mm PVC
insulated, copper conductor, single core cable etc including all other
materials as required complete as per the direction of Engineer-in-Charge.
EARTHING PIT
Earthing with G.I earth plate electrode of 600 mm x 600 mm x 6mm thick
including accessories and providing masonary enclosure with cover plate
having locking arrangement and 2mm thick 3 mtr. long 50dia. G.I pipe for
watering, including 25 x 3 mm size G.I. flat, 2'-0' x 2'-0" chamber with 5"
Brick wall etc. with charcole / coke and salt etc. as required. complete as
per the direction of Engineer-in-Charge.
EARTHING STRIPS
Supplying and laying 25 mm x 5 mm G.I earth strip ISI marked on surface
or recess as strip earth electrode including soldering etc. as required
complete as per the direction of Engineer-in-Charge.
DISTRIBUTION BOARD
Supplying and fixing following way, horizontal type three pole and neutral,
sheet steel, MCB distribution board, 415 V, on surface/ recess, complete
with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required.
including fitting & cutting walls & making good the damages with cement
concrete (1:2:4) with hard granite chips, including scaffolding wherever
necessary, including all cost of labour, material all complete as per direction
of the Engineer-in -charge. 8 way (4 + 24), Double door
MCB - 5A to 32A
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve,
miniature circuit breaker suitable for inductive load of following poles in the
existing MCB DB complete with connections, testing and commissioning
etc. as required, including scaffolding wherever necessary, including all cost
of labour, material all complete as per direction of the Engineer-in -charge.
RCCB
Supplying and fixing 40A rating, four pole, (three phase and neutral), 415 V,
residual current circuit breaker (RCCB), having a sensitivity current 30 mA
in the existing MCB DB complete with connections, testing and
commissioning etc. as required.including scaffolding wherever necessary,
including all cost of labour, material all complete as per direction of the
Engineer-in -charge.
AIR CONDITIONER
Supply / Installation / Gas charging / Testing & Commissioning of any of the
following makes 2T cooling capacity remote condenser split type Air
Conditioning Unit at five different locations & Floor levels (condensing units
mounted on wall brackets or on surface as per site requirements) with
extended liquid/ vapour lines (different lengths),PVC condensate drain pipe
of proper size run on surface, through walls, columns, etc. inside proper
size PVC duct channel, Wiring , complete with material hardware, fittings,
fixture, masonry work such as cutting of grooves, holes etc. and making the
damages good with cement plaster, fillings, painting complete in all respects
as per site conditions and directed by the Engineer-in- Charge. Rating 5
Star
TELEPHONE POINT
Supply & fixing of Telephone point suitable for RJ 11 telephone socket
including mounting box (G.I/PVC) & top cover of approved make to be fixed
in concealed manner in partition/wall by necessary bolts & nuts with all
other accessories etc. as required complete as per the direction of
Engineer-in-Charge.
TELEPHONE WIRE
Supply & Laying of 2 pairs telephone wires ( 0.5 sqmm) in existing Conduit
including all other materials as required as per EIC. A) 2 pairs telephone
wires ( 0.5 sqmm)
OUTDOOR LIGHT WITH FITTING
Supply, Installation,Testing & commissioning of 150W LED IP55 outdoor
light fittings including luminairs of approved make complete with all
materials & labour.(Make : PHILIPS/CG/Havells/Wipro )
CIRCUIT OR SUB-MAIN WIRING
Sub-Main Wiring 4x35 sq.mm sizes PVC insulated XLPE sheathed 1100V,
FRLS Cu. conductor wire of approved make with all other required materials
& labour complete as per the direction of Engineer-in-Charge. 4x35 Sq.mm
METALLIC POLE
Supply & Erection of metallic pole of following length in cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal
size) foundation including excavation and refilling , materials, machinery,
etc. as required including one coat zinc rich primer & two coat of Synthetic
enamel paint of approved shade after properly cleaning the steel surface,
necessary bolts & washers for fixing etc., complete all as per drawings,
specifications etc. with all lead & lift for all materials & labour and as per
direction of Engineer In Charge, at all heights & locations.
Cum
Cum
Kg
Cum
Each
Sqm
Cum
Sqm
Cum
Cum
Sqm
Cum
Sqm
Cum
Cum
Cum
MT
Sqm
Sqm
Sqm
Nos
Kg
Sqm
Nos
Sqm
Kg
Nos
Sqm
Kg
Sqm
Cum
Cum
Cum
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Sqm
Cum
Cum
Cum
Cum
MT
Sqm
Rm
Sqm
Sqm
Cum
Cum
Cum
Sqm
Nos
Nos
Cum
MT
Rm
Rm
Nos
Cum
Sqm
Sqm
Sqm
Cum
Sqm
Nos
Kg
Sqm
Sqm
Cum
Sqm
Sqm
Sqm
Rm
Sqm
Sqm
Each
Each
Rm
Rm
Rm
Nos
Nos
Nos
Rm
Rm
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Nos
Rm
Nos
Rm
MT
MT
Sqm
Sqm
Sqm
Sqm
Sqm
Rm
Kg
Rm
Rm
Sqm
Sqm
Sqm
Nos
Nos
Nos
Nos
Each
Meter
Nos
Nos
Nos
Nos
Rm
Nos
Nos
Nos
Nos
Rm
Rm
Rm
Rm
Nos
Nos
Nos
Rm
Nos
Nos
Nos
Nos
Nos
Nos
Rm
Nos
Rm
Nos
Nos