Design Housing (1), sealing ball (2), spring (3), nipple (A), socket (B)
Function A non-return valve prevents flow in one direction, while allowing free flow in the
opposite direction. In the closed position, the spring (3) presses the sealing ball (2)
onto the valve seat. Flow begins when the pressure in the flow direction exceeds a
value of approx. 1 bar or 5 bar. The sealing ball (2) is then lifted off the valve seat
against the force of the spring (3).
Note Circuits must always be depressurised before a non-return valve is coupled up. It is
not possible in this case to release pressure by means of the pressure relief device
(Order no. 152971).
0.9
n : 30 cSt
p (MPa) 5 bar
J : 42 °C
0.7
0.6
0.5
0.4
0.3
0.2 1 bar
0.1
0
0 1 2 3 4 5 6 8
Pressure-drop/flow-rate characteristic
Actuation Hydraulic