Applications
KS1000 RW SF is a secret-fix, trapezoidal profiled
insulated roof panel which can be used for building
applications with roof pitches of 3° or more after
deflection.
Available Lengths
Standard Lengths 1.8 – 11.8m
Not possible due to
Longer lengths shipping container
restrictions
Shorter Lengths
Below 1.8m
(non-standard)
The number of cover caps per panel width will depend on the purlin centres
1500 - 2000 2
Overall Thickness (mm) 71 81 91 101 111 131 146 151 168 181
U-value (W/m²K) 0.52 0.41 0.34 0.29 0.26 0.21 0.18 0.17 0.15 0.14
R-value (m² K/W) 1.92 2.44 2.94 3.45 3.85 4.76 5.55 5.88 6.67 7.14
Weight kg/m² 0.5 / 0.4 Steel 9.9 10.3 10.7 11.0 11.5 12.3 12.8 13.1 13.7 14.2
The U-values and R-values have been calculated using the method required by the appropriate National Building
Regulations
2
KS1000 RW SF Product
Trapezoidal SF Data Sheet
Product Tolerance
Cut to Length -0.05% +0.1%
Liner Sheet Length -0.1% +0.1%
Cover Width -0mm +3mm
Thickness -2mm +2mm
3
KS1000 RW SF Product
Trapezoidal SF Data Sheet
End Square -3mm +3mm The table below shows the number of panels per pack,
according to depth.
Handing
KS1000 RW SF Core No of panels per
The KS1000 RW SF insulated roof panel can be Thickness (mm) pack
manufactured in both left to right handed (LH) and right 40mm 17
to left handed (RH). 50mm 15
4
KS1000 RW SF Product
Trapezoidal SF Data Sheet
Structural Tables
Unfactored load/span table (use unfactored calculated design wind load values).
Notes:
1. Values have been calculated using the method described in BS EN 14509: 2013, for medium and light coloured panels.
2. Deflection limit for: downward loading is L/200 and suction loading is L/150.
3. The actual wind suction load resisted by the panel is dependent on the number of fasteners used and the purlin thickness as well as the fastener
material.
4. The fastener calculation should be carried out in accordance with the appropriate standards. For further advice please contact Kingspan Technical
Services.
5. The allowable steelwork tolerance between bearing planes of adjacent supports is +/- 5mm.
6. Load span tables for the panel specifications not shown are available from Kingspan Technical Services.
5
KS1000 SF Product
Trapezoidal Secret-Fix Data