Вы находитесь на странице: 1из 2

TECHNICAL DATA

Specification: FOR INSTRUMENT, FIRE RESISTANT, OVERALL


SCREENED, ARMOURED CABLE, GENERALLY TO BS EN 50288-7 &
IEC 60331-23 & IEC 60332-1-2
Customer : CABLE DEPOT FZCO / UAE
Customer's Appellation:
Manufacturer's Appelation/Type : S FXSURU …//DEP-R
RATED VOLTAGE 300/500 V

DESCRIPTION: CU/MICA/XLPE/OSCR/LSZH/GSWA/LSZH
CONDUCTOR STRANDED ANNEALED COPPER Class 2 acc. to BS EN 60228
INSULATION MICA/GLASS FIRE RESISTANT TAPE + XLPE
OVERALL SCREEN POLYESTER TAPE + TINNED STRANDED COPPER DRAIN WIRE + METALLIZED POLYESTER TAPE
BEDDING LOW SMOKE ZERO HALOGEN COMPOUND ( LSZH )
ARMOUR GALVANIZED STEEL WIRES Type-4
OVERSHEATH LOW SMOKE ZERO HALOGEN COMPOUND ( LSZH )

DIMENSIONAL CHARACTERISTICS
ITEM NO. : 10
CABLE SIZE mm² 1*2*1.5
CONDUCTOR Size mm² 1.5
Shape Circular
Fire resistant tape Mica/Glass
INSULATION
Nom. thickness of XLPE mm 0.6
TWISTING Pair
Nom. size. of tinned drain wire mm² 0.5
OVERALL SCREEN
Total thick.of metallized tape mm 0.036
BEDDING Nom. thickness mm 0.9
ARMOUR Nom.diam. of each wire mm 0.9
Nom. thickness mm 1.4
OVERSHEATH
Color Red
MARKING By ink jet printing on one line over the outer jacket
OVERALL DIAM. Nom. Diam. (±7%) mm 13.5
CABLE WEIGHT Approx. kg/km 340

ELECTRICAL & MECHANICAL CHARACTERISTICS


Max. DC conductor resistance at 20°C. ohm/Km 12.34
Voltage test for 1 minute
- Between conductors VAC 2000
- Between conductors & screen VAC 1000

• Conductor operating conditions:


Max. Continuous operating Temp. : 90°C
Max. short circuit Temp. : 250°C
• Cable Operation Temperature Range: -30°C to +70°C
• Installation Condition: -5°C to +50°C • Fire Resistant
Acc. to IEC 60331-23 (750°C for 90 mins)
• Flame Retardant
according to IEC 60332-1-2

Prepared by: Customer Ref. N°:. Our Ref.: 22868 Approved by:

DS 1 14/02/2018 4/13
TECHNICAL DATA
Specification: FOR INSTRUMENT, FIRE RESISTANT, OVERALL
SCREENED, ARMOURED CABLE, GENERALLY TO BS EN 50288-7 &
IEC 60331-23 & IEC 60332-1-2
Customer : CABLE DEPOT FZCO / UAE
Customer's Appellation:
Manufacturer's Appelation/Type : S FXSURU …//DEP
RATED VOLTAGE 300/500 V

DESCRIPTION: CU/MICA/XLPE/OSCR/LSZH/GSWA/LSZH
CONDUCTOR STRANDED ANNEALED COPPER Class 2 acc. to BS EN 60228
INSULATION MICA/GLASS FIRE RESISTANT TAPE + XLPE
OVERALL SCREEN POLYESTER TAPE + TINNED STRANDED COPPER DRAIN WIRE + METALLIZED POLYESTER TAPE
+ POLYESTER TAPE
BEDDING LOW SMOKE ZERO HALOGEN COMPOUND ( LSZH )
ARMOUR GALVANIZED STEEL WIRES
OVERSHEATH LOW SMOKE ZERO HALOGEN COMPOUND ( LSZH )

DIMENSIONAL CHARACTERISTICS
ITEM NO. : 70+160 150
CABLE SIZE mm² 2*2*1.5 1*2*2.5
CONDUCTOR Size mm² 1.5 2.5
Shape Circular Circular
Fire resistant tape Mica/Glass Mica/Glass
INSULATION
Nom. thickness of XLPE mm 0.6 0.7
TWISTING Quad Pair
Nom. size. of tinned drain wire mm² 0.5 0.5
OVERALL SCREEN
Total thick.of metallized tape mm 0.036 0.036
BEDDING Nom. thickness mm 1.1 1.0
ARMOUR Nom.diam. of each wire mm 0.9 0.9
Nom. thickness mm 1.5 1.4
OVERSHEATH
Color Black Black
MARKING By ink jet printing on one line over the outer jacket
OVERALL DIAM. Nom. Diam. (±7%) mm 15.5 16
CABLE WEIGHT Approx. kg/km 423 429

ELECTRICAL & MECHANICAL CHARACTERISTICS


Max. DC conductor resistance at 20°C. ohm/Km 12.34 7.56
Voltage test for 1 minute
- Between conductors VAC 2000 2000
- Between conductors & screen VAC 1000 1000

• Conductor operating conditions:


Max. Continuous operating Temp. : 90°C
Max. short circuit Temp. : 250°C
• Cable Operation Temperature Range: -30°C to +70°C
• Installation Condition: -5°C to +50°C • Fire Resistant
Acc. to IEC 60331-23 (750°C for 90 mins)
• Flame Retardant
according to IEC 60332-1-2

Prepared by: Customer Ref. N°:. Our Ref.: 22868 Approved by: