Академический Документы
Профессиональный Документы
Культура Документы
WELD INDI. THK X Y(yw) BPL(w) A d CLASS L DEPTH y Y-y RESULT REMARKS
IDENTIFICATION NO. mm mm mm mm. dB dB. mm. mm. mm. mm.
Welding Joint Joint no1(F) 25 - - - 37.05 - - - - - Accepted Satisfactory
MB/01A(F) Joint no 25 Accepted Satisfactory
2(F)
Welding Joint 25 350 mm left ward 23.02 42.08 100% 37.05 A Full 11.08 21.01 2.01 Repair e defect IPFind th,SL
Joint no 1(F)
MB/03B(F) To right
25 227mm left ward 27.07- 57.89- 87 37.05 A Full 15.45 26.09 0.80 Repair Find the defect IP,SL
Joint no 2(F)
To right-
Joint no 3(F) 25 - - - - 37.5 - - - - - Accepted Satisfactory
Joint no 4F 25 - - - - 37.05 - - - - - Accepted Satisfactory
Defect Code: C
R- Crack IP-Incomplete Penetration IF– Incomplete Fusion SL- Slag P
- Porosity EP-Excess Penetration CP- Cluster Porosity CON – Concavity BSR – Before Stress Relief ASR – After Stress Rel
TESTED BY: KK JV Witness KK JV AUTHORITY approved
Name:Shaharia alam Name: Md. TowhidHossain Name:
ASNT Level –II (Ultrasonic Test) KK JV - Assistant Engineer
Signature: Signature:
T** LEGEND: X = Circumferential distance from datum, Y= Distance from weld C/L to probe index. BPL = Beam path length, y = Calculated distance from probe index, L = Length, a = Indication level, d =
Indication rating,
T** LEGEND: X = Circumferential distance from datum, Y= Distance from weld C/L to probe index. BPL = Beam path length, y = Calculated distance from probe index, L = Length, a = Indication level, d =
Indication rating,
atisfactory
Defect Code: C
R- Crack IP-Incomplete Penetration IF– Incomplete Fusion SL- Slag P
- Porosity EP-Excess Penetration CP- Cluster Porosity C
ON – Concavity BSR – Before Stress Relief ASR – After Stress Rel
TESTED BY: KK JV Witness KK JV AUTHORITY approved
Name:Shaharia alam Name: Md. TowhidHossain Name:
ASNT Level –II (Ultrasonic Test) KK JV - Assistant Engineer
Signature: Signature: