Вы находитесь на странице: 1из 3

Page 1​ of 3

ULTRASONIC TEST REPORT


Inspection Date : July 15, 2018 Report no : IES/ARBAB/UT-06
Project Name : ARBAB Steel Building UT Equipment : ADVANSCAN AS-414
Contractor : Steel Abiding Ltd Range : 0-100
Location : Shimrail, Demra Road, Dhaka. Search unit : MBW 70 N4 (9MM,60˚,4 MHz)
Inspection Request No. : N/A Calibration block : IIW V2 Block, Reference block
Drawing Reference (S) : Main Beam & Sub Beam Welding Process : ARC WELDING.
Location Details : N/A Welding Prep : Double Vee
ARBAB Comments : Sub-Beam Butt Joint Surface Condition : As Smooth
Couplent : Lube Oil

WELD INDI. THK X Y(yw) BPL(w) A d CLASS L DEPTH y Y-y RESULT REMARKS
IDENTIFICATION NO. mm mm mm mm. dB dB. mm. mm. mm. mm.
Welding Joint Joint no1(F) 25 - - - 37.05 - - - - - Accepted Satisfactory
MB/01A(F) Joint no 25 Accepted Satisfactory
2(F)
Welding Joint 25 350 mm left ward 23.02 42.08 100% 37.05 A Full 11.08 21.01 2.01 Repair e defect IPFind th,SL
Joint no 1(F)
MB/03B(F) To right
25 227mm left ward 27.07- 57.89- 87 37.05 A Full 15.45 26.09 0.80 Repair Find the defect IP,SL
Joint no 2(F)
To right-
Joint no 3(F) 25 - - - - 37.5 - - - - - Accepted Satisfactory
Joint no 4F 25 - - - - 37.05 - - - - - Accepted Satisfactory
Defect Code: C
​ R​- Crack IP-Incomplete Penetration IF– Incomplete Fusion SL- Slag P
​ ​- Porosity ​EP​-Excess Penetration ​CP​- Cluster Porosity ​CON ​– Concavity ​BSR –​ Before Stress Relief ​ASR –​ After Stress Rel
TESTED BY: KK JV Witness KK JV AUTHORITY approved
Name:Shaharia alam Name: Md. TowhidHossain Name:
ASNT Level –II (Ultrasonic Test) KK JV - Assistant Engineer
Signature: Signature:

Date: 25/01/2018 Date: 25/01/2018


TEST CARRIED OUT AS PER CODE & STANDARD OF API Standard 1104

TESTED BY IES-INDUSTRIAL ENGINEERING SERVICES


House # 64, (1​st​ Floor), Road # 06, Block # A, Sec # 12, Mirpur, Dhaka-1216, Phone : +8804477972245, 01710134359, 01711834576,
E-mail: ​iesbd2000@gmail.com​, ​ahies.bd@gmail.com​ashik@iesndt.com​, ​amit@iesndt.com​, Web: www.iesndt.com
Page 2​ of 3

T** LEGEND: X = Circumferential distance from datum, Y= Distance from weld C/L to probe index. BPL = Beam path length, y = Calculated distance from probe index, L = Length, a = Indication level, d =
Indication rating,

ULTRASONIC TEST REPORT


Project ARBAB Steel Building Report no IES/ARBAB/UT-06
Contractor Steel Abiding Ltd Location : Shimrail, Demra Road, Dhaka
WELD INDI. THK X Y(yw) BPL(w) A d CLASS L DEPTH y Y-y RESULT REMARKS
IDENTIFICATION NO. mm mm mm mm. dB dB. mm. mm. mm. mm.
Welding Joint Joint no 1(F) 25 - - - - 37.5 - - - - - Accepted Satisfactory
MB/01B(F) Joint no2(F) 25 - - - - 37.5 - - - - - Accepted Satisfactory
Welding Joint Joint 25 - - - - 37.05 - - - - Accepted Satisfactory
MB/02B(F) no1(F)

T** LEGEND: X = Circumferential distance from datum, Y= Distance from weld C/L to probe index. BPL = Beam path length, y = Calculated distance from probe index, L = Length, a = Indication level, d =
Indication rating,

ULTRASONIC TEST REPORT


Defect Code: C
​ R​- Crack IP-Incomplete Penetration IF– Incomplete Fusion SL- Slag P
​ ​- Porosity ​EP​-Excess Penetration ​CP​- Cluster Porosity C
​ ON ​– Concavity ​BSR –​ Before Stress Relief ​ASR –​ After Stress Rel
TESTED BY: KK JV Witness KK JV AUTHORITY approved
Name:Shaharia alam Name: Md. TowhidHossain Name:
ASNT Level –II (Ultrasonic Test) KK JV - Assistant Engineer
Signature: Signature:

Date: 25/01/2018 Date: 25/01/2018


TEST CARRIED OUT AS PER CODE & STANDARD OF API Standard 1104

TESTED BY IES-INDUSTRIAL ENGINEERING SERVICES


House # 64, (1​st​ Floor), Road # 06, Block # A, Sec # 12, Mirpur, Dhaka-1216, Phone : +8804477972245, 01710134359, 01711834576,
E-mail: ​iesbd2000@gmail.com​, ​ahies.bd@gmail.com​ashik@iesndt.com​, ​amit@iesndt.com​, Web: www.iesndt.com
Page 3​ of 3

Project ARBAB Steel Building Report no IES/ARBAB/UT-06


Contractor Steel Abiding Ltd Location : Shimrail, Demra Road, Dhaka

atisfactory

Defect Code: C
​ R​- Crack IP-Incomplete Penetration IF– Incomplete Fusion SL- Slag P
​ ​- Porosity ​EP​-Excess Penetration ​CP​- Cluster Porosity C
​ ON ​– Concavity ​BSR –​ Before Stress Relief ​ASR –​ After Stress Rel
TESTED BY: KK JV Witness KK JV AUTHORITY approved
Name:Shaharia alam Name: Md. TowhidHossain Name:
ASNT Level –II (Ultrasonic Test) KK JV - Assistant Engineer
Signature: Signature:

Date: 25/01/2018 Date: 25/01/2018


TEST CARRIED OUT AS PER CODE & STANDARD OF API Standard 1104

TESTED BY IES-INDUSTRIAL ENGINEERING SERVICES


House # 64, (1​st​ Floor), Road # 06, Block # A, Sec # 12, Mirpur, Dhaka-1216, Phone : +8804477972245, 01710134359, 01711834576,
E-mail: ​iesbd2000@gmail.com​, ​ahies.bd@gmail.com​ashik@iesndt.com​, ​amit@iesndt.com​, Web: www.iesndt.com