Actuator Inspection SH200

Actuator Inspection

Actuator Inspection
Air Mix Motor Actuator Inspection
• Structural diagram

Air mix damper operation defect

See the chart.

Specifying the trouble location

1 Control amp
2 Air mix motor actuator
3 Connector 1
4 Connector 9

22 RST-07-04-001EN
1
Actuator Inspection
• Chart

IGN OFF ON (when the engine starts)

Does the Is an error


actuator operate at all No displayed after the No
in initial operations? end of initial operation?

Control panel defect


Yes Yes

Does it Is there
operate according to No conductance in the No
the initial operation table harness between the actua-
below? tor and controller
amp?
Harness defect
Yes Yes

Actuator defect or damper


Is an error lock or link defect
displayed after the No
end of initial operation?

Damper lock or link defect

Yes

Disconnect the actuator connector (9).

Is the
resistance btween No
L / Y and B of the actuator
about 4 k ?
Initial operation table
Actuator position before initial operation start Actuator initial operation
Yes
(1) COOLMAX position (0 ) 0 90 0

Is there (2) HOTMAX position (90 ) 90 0


conductance between No (3) Other than the above Current position 90 0
the G / L and L / Y of the actuator
and between G / L
and B?

Yes

Control panel defect Actuator defect

RST-07-04-001EN 23
2
Actuator Inspection
Refresh/Recirculate Motor Actuator Inspection
• Structural diagram

L/W L/W

L/G

M
L/R L/R

L/G

Inside / outside air mix damper operation defect

See the chart.

Specifying the trouble location

1 Control amp
2 Refresh/recirculate motor actuator
3 Connector 1
4 Connector 2
5 Connector 11

24 RST-07-04-001EN
3
Actuator Inspection
• Chart

Switch the ignition OFF ON (to start the engine)


and complete the air mix and mode initial operation.

Press the
refresh / recirculate No
switch. Does the actuator
operate at all?

Yes

Switch the
setting to recirculate. No
Does the actuator become
about 0 ?

Yes

Switch the
setting to refresh. Does No
the actuator become
about 90 ?

Yes Is a refresh / recirculate No


error displayed?
Damper lock or link defect
Control panel defect
Yes

Is there
conductance in the No
harness between the actuator
controller and
amp?
Harness defect
Yes

Actuator defect or damper


lock or link defect

RST-07-04-001EN 25
4
Actuator Inspection
Mode Motor Actuator Inspection
• Structural diagram

Y/W Y/W

Y
Y/R
B Y
Y/L
L/Y M
Y/R
B

Y/L

1 L/Y

Mode damper operation defect

See the chart.

Specifying the trouble location

1 Control amp
2 Mode motor actuator
3 Connector 1
4 Connector 10

26 RST-07-04-001EN
5
Actuator Inspection
• Chart

IGN OFF ON (when the engine starts)

Does the Is an error


actuator operate at all No displayed after the No
in initial operations? end of initial operation?

Control panel defect


Yes Yes

Does it Is there
operate according to No conductance in the No
the initial operation table harness between the actua-
below? tor and controller
amp?
Harness defect
Yes Yes

Actuator defect or damper


Is an error lock or link defect
displayed after the No
end of initial operation?

Damper lock or link defect

Yes

Disconnect the actuator connector (10).

Is the
resistance btween No
L / Y and B of the actuator
about 4 k ?
Initial operation table
Actuator position before initial operation start Actuator initial operation
Yes
(1) COOLMAX position (0 ) 0 90 0

Is there (2) HOTMAX position (90 ) 90 0


conductance between No (3) Other than the above Current position 90 0
the Y / L and L / Y of the actuator
and between Y / L
and B?

Yes

Control panel defect Actuator defect

RST-07-04-001EN 27