Вы находитесь на странице: 1из 2

CARUHATAN NATIONAL HIGH SCHOOL

TECHNOLOGY AND LIVELIHOOD EDUCATION


4th Grading Examination
Grade 10 Electrical Installation and Maintenance

Name: ______________________________________________________ Score: _________________


Grade & Section: _____________________________________________ Date: _________________
DIRECTIONS: Read the following questions carefully and choose the letter that best describes the statement.
1. Seiton
a. Sort b. Sweep c. Standardize d. Set in order
2. Seiri
a. Sort b. Sweep c. Standardize d. Set in order
3. Shitsuke
a. Sweep b. Set in order c. Standardize d. Self-discipline
4. Seiketsu
a. Sweep b. Set in order c. Standardize d. Self-discipline
5. Seiso
a. Sweep b. Set in order c. Standardize d. Self-discipline
6. Gloves
a. Hand b. Foot c. Head d. Body
7. Hard Hat
a. Head b. foot c. hands d. body
8. Ear plug
a. Ear b. Nose c. Eyes d. Mouth
9. Apron
a. chest b. head c. hand d. foot
10. Safety glass
a. body b. eyes c. hand d. foot
11. Face shield
a. head b. body c. face d. foot
12. Holster
a. Seiton b. Seiri c. Seiketsu d. Seiso
13. Tools operated and manipulated by our hands w/ electrical energy
a. hand tool b. power c. pneumatic d. Hydraulic
14. NOT Biological Hazards
a. Bacteria b. Virus c. Fungi d. Dust
15. Physical hazards
a. Noise b. Vibration c. Ionizing d. All of the above
16. Chemical
a. Vapor b. Dust c. Mist d. All of the above
2
17. 2.0mm
a. #16 b. #14 c. #12 d. #10
18. Less expensive and abundant material for electrical wire
a. coppers b. aluminums c. lead d. Zinc
19. 8.0mm2
a. #8 b. #10 c. #12 d. #14
20. Protective device for C.0
a. 10 b. 20 c. 30 d. 60
21. This is usually bare solid or stranded conductor used for overhead transmission line and ground wires.
a. Copper or aluminum conductor b. Non-metallic sheathed cable (type NM)
c. Control cable (braided type) d. Copper or aluminum PE insulated line wire
22. This is a flame retardant, moisture resistant wire used for building wiring installation in dry or wet locations.
a. Thermoplastic Portable cords (type SJT & ST) b. Thermoplastic wire (type TW)
c. Control cable (braided type) d. Flat cord (type SPT)
23. A wire commonly used for wiring motorized engines and appliances with high temperature, and for switch
board wiring
a. Temperature wire (type HI) b. Control cable (braided type)
c. Asbestos covered nickel cord (Rockbestos) d. Steel tape armored power cable with ground wire
24. This is a multi-conductor cable generally used for interior wiring installations in dry and wet locations.
a. Power cable b. Nonmetallic sheathed cable (type NMC)
c. Royal cable d. Submersible pump cable
25. What is the equivalent diameter size of number 10 AWG wire in millimeter (mm)?
a. 2.0 mm b. 3.5 mm c. 5.5 mm d. 8 mm
26. What is the equivalent diameter size of number 8 AWG wire in millimeter (mm)?
a. 6mm b. 8 mm c. 10 mm d. 12 mm
27. It is a type of flexible armored cable that has rubber insulation and a lead sheath between the conductor
and the armor.
a. type AC b. type ACT c. type ACV d. type ACL
28. The appropriate tool used in cutting flexible armored cable.
a. Pliers b. Backsaw c. Hacksaw d. Knife
29. What do you call a plastic or metal material that is used for mounting of convenient outlets and switches on
walls?
a. Junction Box b. Frames c. Utility Box d. Fitting
30. It is used for branching conductors and enclosing splices.
a. Utility Box b. Fastening Device c. Junction Box d. Adhesive
31. It is any associated material for connecting end of stock securely.
a. Fitting b. Ground c. Rigid d. Wire ways
32. It is used for mounting a convenience outlet on walls.
a. Junction Box b. Frames c. Utility Box d. Fitting
33. It is used for splitting conductors and splices.
a. Utility Box b. Fastening Device c. Junction Box d. Adhesive
34. It is a blend used to adopt the conduit from surface to a particular box or fittings.
a. Bending b. Offset c. Conduit bending d. Strap
35. It is a process of removing sharp edges or burrs left after cutting the pipe.
a. Shaping b. Reaming c. Finishing d. Smoothing
36. What is the tool used to bend a metallic conduit?
a. Hacksaw b. Hickey c. Hammer d. Reamer
37. How many degrees is a quarter angle bend?
a. 45 degrees b. 90 degrees c. 180 degrees d. 135 degrees
38. What type of conduit is designed to lessen or eliminate fire hazard and electrical accident?
a. Electrical Metallic Tubing b. Rigid Steel Conduit
c. Polyvinyl Chloride d. Armored Cable (BX)
39. How many quarter bends are allowed in one run of electrical metallic and nonmetallic conduit as allowed by
code?
a. 2 b. 3 c. 4 d. 5
40. What type of fitting is used to secure EMT to metallic boxes?
a. Connector b. Condulets c. Adapter with locknut d. Coupling
41. What is the type of bend that makes one quarter turn?
a. Offset b. Elbow c. Saddle d. Goose neck
42. What is the standard length of Rigid Metallic Conduit?
a. 10 ft. b. 12 ft. c. 14 ft. d. 20 ft.
43. A neutral conductor shall be placed within the __________________
a. Same conduit b. The other conduit c. Separate circuit d. anywhere
44. It is the minimum size of conduit which can be installed in industrial occupancies.
a. ½” b. ¾” c. 1” d. 1 ½”
45. It is a type of fitting which is used to change direction.
a. Connector b. Coupling c. Adaptor d. Elbow
46. It is a short length conduit or tubing which is used to extend a conduit system and used between conduit
and tubing such as boxes or enclosures between two boxes.
a. Connector b. Coupling c. Nipple d. Condulets
47. It is a type of bend which is used for circuit homerun.
a. Offset b. Elbow c. Saddle d. Goose neck
48. What electrical materials are used for the installation of electrical wiring fixtures like switches, receptacles
and for making electrical termination?
a. Utility box b. Square Box c. Junction Box d. Electrical Boxes
49. What code is responsible for setting the rules and regulations which govern all electrical wiring installations
where in standard and specifications must be followed?
a. Municipal Code b. local Code c. Philippine Electrical Code d. National Electrical Code
50. What types of electrical conduit are designed to protect the electrical wiring of building from electrical
hazard due to faulty wiring?
a. Electrical Metallic Tubing b. Rigid Steel Conduit
c. Polyvinyl Chloride d. Flexible Metallic Tubing

Вам также может понравиться