Вы находитесь на странице: 1из 4

Page No.

1/4

Date 26th July 2019

No. ZZHL0725P

To:

ARGENT VENTURES INC.

FOR

WIRE CABLE PROJECT

Cable approved by the CCC,ISO,PCCC certificates.

Prepared by

Senior Design Engineer General Manager


Design & Engineering Group Design & Engineering Group
Engineering Department Engineering Department
Zhengzhou Hongliang Cable Co.,Ltd Zhengzhou Hongliang Cable Co.,Ltd

Zhengzhou Hongliang Cable


Zhengzhou Hongliang Cable Co.,Ltd
ADD: NO.11 ZHENGSHANG ROAD,ZHENGZHOU CITY,HENAN P.R.,CHINA

TEL: 0086-371-66766667 FAX: 0086-371-87513085 Web:www.cables-factory.com

Bare Copper Conductor

Application:
Solid and stranded (classes AA and A) bare copper are suitable for overhead transmission and distribution applications.
Stranded conductor of greater flexibility (classes B and C) are suitable for uninsulated hook up, jumpers, and grounds in
electrical construction. Soft Drawn copper is unilay construction.

Construction:
Conductor Class 2 annealed stranded copper conductor according to IEC 60228

Drawing

Techinical sheet of Bare Copper


Reference Standard: ASTM,BS EN 13602,IEC 60228 IEC 61089

Item Description Unit Data


1 Specification Bare Copper 50mm²
Copper Conductor
- Material / Annealed copper stranded wire

-Conductor Type / Circular Stranded


2
- Area mm² 50
- No. Of Wires / 7
- Wire diameter mm 3.0
Finished Cable
3 - Overall Dia. of Cable mm 9.0
- Weight kg/km 457
Electrical Characteristics
4
- Max.D.C. Resistance at 20℃ Ω/KM ≤0.387
Zhengzhou Hongliang Cable Co.,Ltd
ADD: NO.11 ZHENGSHANG ROAD,ZHENGZHOU CITY,HENAN P.R.,CHINA

PHILIPPINE NATIONAL STANDARD DPNS 35:2002


Electric wires and cables - -insulated copper wires and cables rated 600 volts - Specification

type THHN insulation


a heat-resistant thermoplastic (PVC) insulation with nylon jacket suitable for the type of service where the conductor temperature does
not exceed 90°C in dry location or 105°C in wet location. It is employed as insulation for class THHN building wire

conductor
a material usually in the form of a wire or cable suitable for carrying electric current

bare conductor
a conductor with no covering or insulation

insulated conductor
a conductor covered with an insulation

stranded conductor
a conductor composed of a group of wires or any combination of wire groups

dielectric strength
the capability of the insulation of a finished wire or cable to withstand without breakdown the application of a test potential
under specified conditions

insulation
a non-conducting material used to serve as barrier between energized parts of an electric circuit thereby confining the flow of
electric current to the conductor

jacket
a protective covering over the insulation
ZhengZhou Hongliang Cable Co.,LTD
ADD: NO.11 ZHENGSHANG ROAD,ZHENGZHOU CITY,HENAN P.R.,CHINA

THHN CABLE:600V/CU/PVC/PVC Technical Sheet

For cable tray installation,wire ways,open


wiring,conduits,service entrances,feeders,ad branch
Application: circuits for permanent installations,suitable for power
lighting installations in residential,commercial,and
industrial establishments.

Voltage: 600v
Copper conductor according to ICEA,ASTM, DIN VDE
Construction: 0295 and IEC 60228 class 2.
Copper compacted stranded conductors,pvc insulated
and PVC jacketed for THHN with temperature of
Description: 600v/90℃ dry or wet applications.
Cable standard: IEC 60227,UL Standard
Specification
NO. Description Unit Manufacture offer Manufacture offer
1 Rated Voltage V 600 600
2 Test voltage kv 3.5 3.5
3 Specification - Cu/PVC/PVC Cu/PVC/PVC
4 Cross section mm2 14 3.5
5 Conductor - Pure Tinned Copper Pure Tinned Copper
6 No. of conductor No. 7 7
Conductor shape Compacted Circular Compacted Circular
Standed Standed
7 Conductor diameter mm 4.8 2.4
Insulation material Fire Resistance & Fire Resistance &
UV-Protection & Oil UV-Protection & Oil
Resistant WITH Resistant WITH
8 -
ANTI-Rodent / Termite ANTI-Rodent /
Protection Termite Protection
PVC 90℃ PVC 90℃
9 Insulation color - Black Black
10 Average insulation Thickness mm 1.0 1.0
Jacket material Fire Resistance & Fire Resistance &
UV-Protection & Oil UV-Protection & Oil
Resistant WITH Resistant WITH
11 -
ANTI-Rodent / Termite ANTI-Rodent /
Protection Termite Protection
PVC 90℃ PVC 90℃
12 Insulation color - Black Black
13 Average insulation Thickness mm 1.4 1.4
14 Diameter of complete cable mm 10.2 7.2
15 Approximate weight Kg/km 213 84
16 Max. DC Resistance at 20℃ Ω/km 1.35 5.64
Min.insulation DC resistance (15℃ in
17 MΩ.km 175 175
water)
18 Unaged Acceptable tensile strength Mpa 13.8 13.8
Unaged acceptable ultimate
19 % 150 150
Elongation
20 Retention of tensile strength percent % 75 75
21 Retention of elongation percent % 65 65
Current rating
22 A 75/85 40/50
Direct in air/Direct in soil