Академический Документы
Профессиональный Документы
Культура Документы
Page 1 of 24
Form 1335
Issue 5
Certificate Contents
Approved Site Application ........................................................................................................ 2
Basis of Certification ............................................................................................................... 2
Certified Performance ............................................................................................................. 5
Description........................................................................................................................... 23
General Notes ...................................................................................................................... 24
Any potential user should ensure, in consultation with the manufacturer, that the monitoring system
is suitable for the intended application. For general guidance on monitoring techniques refer to the
Environment Agency Monitoring Technical Guidance Notes available at www.mcerts.net
On the basis of the assessment and the ranges required for compliance with EU Directives this instrument is
considered suitable for use on waste incineration and large coal-fired combustion plant applications. This CEM
has been proven suitable for its measuring task (parameter and composition of the flue gas) by use of the QAL
1 procedure specified in EN14181, for LCPD/IED Chapter III and IED Chapter IV applications for the ranges
specified. The lowest certified range for each determinand shall not be more than 1.5X the daily average
emission limit value (ELV) for IED Chapter IV applications, and not more than 2.5X the ELV for IED Chapter
III and other types of application.
Two initial field trials were conducted over 4 months from 25.11.2014 until 18.03.2015 and from 15.04.2014
until 13.08.14, in clean gas in a waste combustion plant; the third field trial ran from 13.11.2015 to 24.5.2016.
A fourth field trial was conducted on the ULTRAMAT 23 additional NO2 and SO2 ranges, and the SIPROCESS
GA700 for CO2 and O2 on a waste combustion plant from 06.11.2018 to 13.02.2019.
Basis of Certification
This certification is based on the following Test Report(s) and on Sira’s assessment and ongoing
surveillance of the product and the manufacturing process:
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 2 of 24
Form 1335
Issue 5
The Set CEM CERT measuring system consists of the following parts:
A different brand or model of sampling system of the same type, provided that there is
evidence the alternative system works with similar types of CEM.
Additional manifolds and heated valves used to allow more than one analyser to share a
sampling system.
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 3 of 24
Form 1335
Issue 5
This certificate applies to all instruments fitted with software version:
ULTRAMAT 23-7MB2355 – Software version: 2.15.05. onwards (Serial No: N1-E7-928 onwards)
ULTRAMAT 23-7MB2357 – Software version: 2.15.05 onwards (Serial No: N1-B5-208 onwards)
ULTRAMAT 23-7MB2358 – Software version: 2.15.05 onwards(Serial No: N1-E7-261 onwards)
SIPROCESS GA700 Ultramat 7 – Software version CALC 1.40.03 / ADU 1.33.00 onwards (Serial
no: N1JN000255 onwards)
SIPROCESS GA700 Oxymat 7 – software version CALC 1.40.05 / ADU 1.20.05 onwards (Serial no:
N1JN000255 onwards)
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 4 of 24
Form 1335
Issue 5
Certified Performance
The instrument was evaluated for use under the following conditions:
*For use with the ULTRAMAT 23 (7MB2355, 7MB2357 and 7MB2358), the system needs to be equipped with an air
conditioning unit.
Note: For outdoor installations the analyser needs to be mounted into an IP65 environment. If the instrument is supplied
with an enclosure, then the ambient temperature shall be monitored inside the enclosure to ensure that it stays within the
above ambient temperature range.
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 5 of 24
Form 1335
Issue 5
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
NO (ULTRAMAT 23) – (0 to 3000mg/m3) 41s <200s
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 6 of 24
Form 1335
Issue 5
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
NO (SIPROCESS UV600) – (0 to 50mg/m3) 0.23 <2.0%
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 7 of 24
Form 1335
Issue 5
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
NO2 (SIPROCESS UV600) – (0 to 50mg/m3) 0.11 <2.0%
Lack-of-fit
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 8 of 24
Form 1335
Issue 5
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
NO (ULTRAMAT 6) – (0 to 2000mg/m3) -0.45 <2.0%
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 9 of 24
Form 1335
Issue 5
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
Influence of ambient temperature zero point
(+5°C to +40°C)
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 10 of 24
Form 1335
Issue 5
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
CO (ULTRAMAT 23) – (0 to 1250mg/m3) 1.5 <5.0%
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 11 of 24
Form 1335
Issue 5
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
NO (ULTRAMAT 6) – (0 to 1000mg/m3) -0.1 <2.0%
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 12 of 24
Form 1335
Issue 5
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
SO2 (ULTRAMAT 23) – (0 to 400mg/m3) -1.0 <2.0%
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 13 of 24
Form 1335
Issue 5
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
Influence of voltage variations (reference)
(196V to 253V)
Influence of vibration To be
No effect
reported
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 14 of 24
Form 1335
Issue 5
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
NO (SIPROCESS UV600) – (0 to 50mg/m3) 2.42 <4.0%
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 15 of 24
Form 1335
Issue 5
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
NO2 (SIPROCESS UV600) – (0 to 50mg/m3) -3.69 <4.0%
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 16 of 24
Form 1335
Issue 5
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
CO2 (ULTRAMAT 23) - (For an ELV of 25Vol-%) 7.3% <7.5% (10%)
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 17 of 24
Form 1335
Issue 5
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
Response time (field)
Lack-of-fit (field)
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 18 of 24
Form 1335
Issue 5
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
NO (ULTRAMAT 6) – (0 to 100mg/m3) -1.70 <2.0%
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 19 of 24
Form 1335
Issue 5
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
O2 *P (ULTRAMAT 23) (0 to 25 Vol-%) 6 months
Zero and Span drift requirement The AMS has a means of automatic checking Clause
and as necessary readjustment of the zero 6.13 & 10.13
point. The deviations are recorded; a status
signal is set should the level exceed the Manufacturer shall provide a
permissible limit. The deviations in the description of the technique to
indicative drift test in the laboratory were within determine & compensate for
the permissible tolerance limits. zero and span drift
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 20 of 24
Form 1335
Issue 5
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
O2 (OXYMAT 6) - (0 to 25 Vol-%) -0.06 <0.2%
Availability
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 21 of 24
Form 1335
Issue 5
Test Results expressed as % of the Other results MCERTS
certification range specification
<0.5 <1 <2 <5
OXYMAT 6 99.2% >95%
Reproducibility
Note 1: For the SIPROCESS UV600-7MB2621 analyser, the maintenance interval is 2 weeks, but can be
extended to six months for the component SO2 and 3 months for the component NO2 by way of weekly checks
using the internal calibration cell. When adding additional modules to the Set CEM CERT 7MB1957 measuring
system, each combination of modules needs to be checked for functionality as part of testing proper installation
and the maintenance interval has to be determined.
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 22 of 24
Form 1335
Issue 5
Description
Set CEM Cert is a modular, multi-component continuous emission monitoring system for flue gases. The
sample gas is taken from the gas duct by use of a gas sampling and led to the measuring system via a heated
sample gas line.
Subsequent analysis of the gas concentrations is carried out by individual gas analyser modules according to
desired measuring component and measuring range.
The tested Set CEM Cert system comprised the following analysers:
ULTRAMAT 23 – 7MB2355 for 1 measuring component out of 4 (CO, CO2, NO, SO2) or the 2 components
NO2 and SO2
ULTRAMAT 23 – 7MB2357 for 2 measuring components out of 4 (CO, CO2, NO, SO2) or the 2
components NO2 and SO2 and 1 measuring component out of 4 (CO, CO2, NO, SO2)
ULTRAMAT 23 – 7MB2358 for 3 measuring components (CO, NO, SO2) or the 2 components NO2 and
SO2 and 2 measuring component out of 4 (CO, CO2, NO, SO2)
ULTRAMAT 23 – 7MB235x –Z –T13 (x=5, 7, 8) including paramagnetic O2 measurement
ULTRAMAT 23 – 7MB235x –Z –T23 (x=5, 7, 8) including electrochemical. O2 measurement
SIPROCESS UV600 for NO, NO2, and SO2 measurement
ULTRAMAT 6 for 1 or 2 measuring component out of 3 (CO, NO, SO2)
OXYMAT 6 for O2 measurement
ULTRAMAT OXYMAT 6 for measuring O2 and 1 component out of 3 (CO, NO SO2)
SIPROCESS GA700 ULTRAMAT 7 for measuring CO2
SIPORCESS GA700 OXYMAT 7 for measuring O2
Additional measuring ranges:
Component Analyser Certification range Additional Ranges Unit
CO ULTRAMAT 23-7MB2355 0 – 200 0 – 1250 - mg/m³
ULTRAMAT 23-7MB2357 0 – 1250 0 - 6000 -
ULTRAMAT 23-7MB2358 0 – 250 0 – 1250 - mg/m³
ULTRAMAT 6 0 – 75 0 - 1250 0 - 3000 mg/m³
0 - 1000 0 – 10,000 -
ULTRAMAT/OXYMAT 6 0 – 75 0 – 1250 - mg/m³
0 - 1000 0 – 10,000 -
NOx ULTRAMAT 23-7MB2355 0 – 150 1) 0 – 750 1) 0 – 2000 1) mg/m³
0 – 230 2) 0 – 1150 2) 0 – 3067 2)
ULTRAMAT 23-7MB2357 0 – 150 1) 0 – 400 1) 0 – 2000 1) mg/m³
0 – 230 2) 0 – 613 2) 0 – 3067 2)
ULTRAMAT 23-7MB2358 0 – 400 1) 0 – 2000 1) - mg/m³
0 – 613 2) 0 – 3067 2) -
NO SIPROCESS UV600 0 – 50 0 – 200 0 – 2000 mg/m³
ULTRAMAT 23-7MB2355 0 - 600 0 - 3000 - mg/m³
ULTRAMAT 23-7MB2357
ULTRAMAT 6 0 – 100 0 – 2000 - mg/m³
0 – 1000 0 – 10,000
ULTRAMAT/OXYMAT 6 0 – 100 0 – 2000 - mg/m³
0 – 1000 0 – 10,000
NO2 SIPROCESS UV600 0 – 50 0 – 500 - mg/m³
SO2 ULTRAMAT 23-7MB235x 3) 0 – 400 0 – 2000 0 – 7000 mg/m³
SIPROCESS UV600 0 – 75 0 – 130 0 – 2000 mg/m³
ULTRAMAT 6 0 - 75 0 - 1500 - mg/m³
ULTRAMAT/OXYMAT 6 0 - 75 0 - 1500 - mg/m³
CO2 ULTRAMAT 23-7MB2355 0 - 25 - - mg/m³
ULTRAMAT 23-7MB2357
O2 ULTRAMAT 23-7MB235x – Z – T13 3) 0 – 25 - - Vol.-%
paramagnetic OXYMAT 6 0 – 25 0–5 - Vol.-%
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 23 of 24
Form 1335
Issue 5
General Notes
1. This certificate is based upon the equipment tested. The Manufacturer is responsible for
ensuring that on-going production complies with the standard(s) and performance criteria
defined in this Certificate. The Manufacturer is required to maintain an approved quality
management system controlling the manufacture of the certified product. Both the product
and the quality management system shall be subject to regular surveillance according to
‘Regulations Applicable to the Holders of Sira Certificates’. The design of the product certified
is defined in the Sira Design Schedule V00 for certificate No. Sira MC160288/01
2. If certified product is found not to comply, Sira Certification Service should be notified
immediately at the address shown on this certificate.
3. The Certification Marks that can be applied to the product or used in publicity material are
defined in ‘Regulations Applicable to the Holders of Sira Certificates’.
4. This document remains the property of Sira and shall be returned when requested by the
company.
Certificate No : MC160288/03
This Certificate issued : 29 March 2019
This certificate may only be reproduced in its entirety and without change
To authenticate the validity of this certificate please visit www.csagroupuk.org/mcerts
Page 24 of 24
Form 1335
Issue 5