Вы находитесь на странице: 1из 22

CARMEL B. SABADO CE-164 PROF.Allan E.

Milano
BSCE-5 Timber Excel Program
*note:the boxes in yellow should be inputed by the designer,while blue ones are computed by the program.=)

DESIGN OF PURLINS

DATA: LOADINGS:
Type of wood: pahutan Wind Pressure 0.96 kPa (+) Windward
Bending and Tension(Fb) 13.80 MPa Minimum Roof Live Load 0.80 kPa
Shear(Fv) 1.34 MPa GI roofing 0.15 kPa
Compression(Fc) 8.14 MPa Residential Live Load 2.00 kPa
Modulus of Elasticity(E) 9100.00 MPa
Relative Density(G) 0.55
Specific Gravity 5.40 kN/m3 SPACING:
Purlins 0.40 m
Truss 2.75 m
Floor Joist 0.40 m

Wnt
Wn2

q WDL+LL

DATA: TRIAL DIMENSION:


Span 3.73 m 50 x 150 mm
Height 2.00 m I= 1.41E+07 mm4
Theta, q; 28.23

LOADINGS:
Live load 0.32 Kn/m
Roofing 0.06 Kn/m
Purlin weight 0.04 Kn/m
WDL+LL 0.42 Kn/m
Load Combinations:
Condition 1: DL + LL
WDL+LL = 0.37 kN/m governs!!
Condition 2: DL + LL + WL
WDL+LL+WL = 0.22 kN/m LOAD COMBINATION:
Windward:
Pn = 1.3(sinq - 0.5)P 0.11 kN/m
Leeward:
MOMENTS: Pn = -0.5P -0.48 kN/m
Mn = Mx = 1/8(WnLx2) 0.6425298 Kn-m
(WW) Wn1 = Pn(Spacing) 0.04 kN/m
Mt = My = 1/12(WnLy2 0.1234836 Kn-m (LW) Wn1 = Pn(Spacing) -0.192
Wn2 = WDL+LL(cosq) 0.37 kN/m
Wnt = WDL+LL(sinq) 0.20 kN/m
SHEAR:
WN = Wn1 + Wn2 0.41 kN/m
Vx = (1/2)WnLx 0.6899648 Kn Wt = Wnt 0.20 kN/m

Vy = (1/2)WnLy 0.198899821 Kn

CHECK FOR BENDING:


6 Mx 6 My
To be safe, Fb > Fact = + 2 = 5.40 Kn-m < 13.80 Mpa
bh 2 b h it is safe!=)

CHECK FOR SHEAR;


3 Vx 3 Vy
To be safe, Fv > Fvact = + = 0.18 Kn < 1.34 Mpa
2 bh 2 bh it is safe!=)

CHECK FOR DEFLECTION: ****To be safe, Yall > Yact

Yact = (5/384)(WLn4/EI) = 2.16 mm


Yallow = L/360 = 7.64 mm
it is safe!=)
DESIGN OF TRUSS

TRIAL DIMENSION:
75 x 200 mm
I= 5.00E+07 mm4

LOAD CARRIED BY THE TRUSS:

Loadings:
GI roofing = 1.7440325 Kn
Wt. of Purlins = 0.1112925 Kn
Min. Roof LL = 9.3015066 Kn
total = 11.156832 Kn

Weight of truss:
Overall Length of Truss = 44.52 m
Weight of Truss = 3.6034488 Kn
TOTAL 14.76028 Kn

Windward 0.607
wind load = 1.28309604 Kn/m
fx = 0.15173947 Kn 1.283
fy = 0.28261476 Kn q

1.130

Leeward
wind load = -5.58090396 Kn/m
fx = 0.66 Kn
fy = 1.22925 Kn
4.917

Load carried by the ceiling: 5.581


Ceiling Loa = 0.003725 Kn/m q

2.64

Forces Due to DL + LL
7.38014 KN

3.690 Kn 3.6901 Kn

3.690 Kn 3.690 Kn

3.69 kn
3.69 Kn
ceiling load

0.8
0.8

1.8625 m 1.8625 m 1.8625 m 1.8625 m 1.863 m 1.8625 m

7.45 m
0.946635
Forces Due to Wind Load
0.28261476
0.811739 0.2826
v
0.1517 J 0.66
0.2826148 K 0.283
v
0.1517 I
L 0.66
0.283 0.283
H v
0.66
A G
B C D E F

Reactions due to DL + LL

Summary of Bar Forces:

Top Chords Length DL + LL WL DL + LL + WL


AH 1.40 0.55 0.36 0.91
HI 1.40 -9.53 -0.13 -9.65
IJ 1.40 -9.15 -0.07 -9.22
JK 1.40 -9.15 -0.98 -10.1
KL 1.40 -9.53 -0.95 -10.5
LG 1.40 0.55 -0.59 -0.04
Bottom ChordS
AB 1.24 -0.97 -0.50 -1.47
BC 1.24 3.24 2.71 5.95
CD 1.24 8.42 3.00 11.42
DE 1.24 8.42 2.17 10.59
EF 1.24 3.24 1.35 4.59
FG 1.24 -0.97 1.20 0.23
Verticals
BH 0.64 -10.68 -0.56 -11.2
CI 1.27 -2.69 -0.10 -2.8
DJ 1.91 0.50 -0.46 0.0
EK 1.27 -2.69 -0.38 -3.1
FL 0.64 -10.68 -0.26 -10.9
Diagonals
HC 1.40 5.78 0.39 6.17
ID 1.78 -0.22 -0.22 -0.44
KD 1.78 -0.22 0.93 0.70
LE 1.40 5.78 0.90 6.68

Design of Truss Members


Stresses Length
Top Chord -9.526 1.395
Bottom chord 8.419 1.240
Vertical -10.680 / -0.560 0.640
Diagonal 5.780 / 0.390 1.395

DESIGN OF Top Chord

TRIAL DIMENSION:
75 x 200 mm
I= 5.00E+07 mm4

P= -9.526 Kn
L= 1395.00 mm

L/d = 18.6

.5
π E
K= ( )(
4 6 fc ) = 10.7206903 since L/d>K and L/d>11 it is long column

To be safe:
Fc >= fc

2
π E
Fc=
L 2
36( )
d
Fc = 7.21
fc = P/A = 0.64 < 7.21 it is safe!=)

Therefore use 75 x 200 mm for BOTTOM CHORD

DESIGN OF Bottom Chord

TRIAL DIMENSION:
75 x 200 mm
I= 5.00E+07 mm4

P= 8.419 Kn
L= 1.24 mm
L/d = 0.0165333

.5
π E
K= ( )(
4 6 fc ) = 10.7206903 since L/d<K and L/d<11 it is short column

To be safe:
Fc >= fc

π2 E
Fc=
L 2
36( )
d
Fc = 9126784.44
fc = P/A = 0.56 < 9126784 it is safe!=)

Therefore use 75 x 200 mm for BOTTOM CHORD

DESIGN OF Verticals

TRIAL DIMENSION:
75 x 200 mm
I= 5.00E+07 mm4
P= -10.680 / -0.560 Kn
L= 0.64 mm

L/d = 0.0085333

.5
π E
K= ( )(
4 6 fc ) = 10.7206903 since L/d<K and L/d<11 it is short column

To be safe:
Fc >= fc

2
π E
Fc=
L 2
36( )
d
Fc = 3.43E+07
fc = P/A = 0.71 < 3.43.E+07 it is safe!=)

Therefore use 75 x 200 mm for BOTTOM CHORD

Check for Stress Reversals: To be safe:

Fb >= ft

Fb = 13.80 MPa
P
f t= = 0.06 < 13.80 it is safe!=)
( 3/ 5 ) A g

Since Fb > Ft, Use 75 x 200 mm for VERTICALS

DESIGN OF Diagonals

TRIAL DIMENSION:
75 x 200 mm
I= 5.00E+07 mm4

P= 5.780 / 0.390 Kn
L= 1.40 mm

L/d = 0.0186

.5
π E
K= ( )(
4 6 fc ) = 10.7206903 since L/d<K and L/d<11 it is short column

To be safe:
Fc >= fc

2
π E
Fc=
L 2
36( )
d
Fc = 7.21E+06
fc = P/A = 0.39 < 7.21.E+06 it is safe!=)
Therefore use 75 x 200 mm for BOTTOM CHORD

Check for Stress Reversals: To be safe:

Fb >= ft

Fb = 13.80 MPa
P
f t=
( 3/ 5 ) A g= 0.04 < 13.80 it is safe!=)

Since Fb > Ft, Use 75 x 200 mm for VERTICALS


DESIGN OF POST

At Truss supports DL + LL WL DL + LL + WL
A -26.7 -0.66 -27.36
B -26.7 -0.28 -26.98
At Girder Supports -9.98 0 -9.98 4P= Interior posts carries a max of
4 girders
4P= 109.4 Kn

TRIAL DIMENSION: 110.1 Kn


200 x 200 mm
I= 1.33E+08 mm4

Length of column = 3.15 m


Weight of Column = 0.679896 Kn

L/d= 15.75
.5
π E
K= ( )(
4 6 fc ) = 10.7206903

since L/d > K and L/d > 11 it is long column.

To be safe:
Fc >= fc
Fc = 8.14 Mpa
fc = P/A
= 2.7529974 Mpa

Therefore use 200 x 200 mm for POST


CARMEL B. SABADO CE-164 PROF.Allan E. Milano
BSCE-5 Timber Excel Program
*note:the boxes in yellow should be inputed by the designer,while blue ones are computed by the program.=)

DESIGN OF T & G

DATA: TRIAL DIMENSION:


Residential Live Load 2.00 kPa 25 x 100 mm
Specific Gravity 5.40 kN/m 3
I= 2.08E+06 mm 4

Modulus of Elasticity 9100.00 MPa

0.1 0.1 0.1 0.1

0.025

0.4 m

LOADINGS:
Dead Load (Weight of T&G) = Area X S.G. = 0.0135 kN/m
Live Load (Residential LL) = 0.2 kN/m
WDL+LL = 0.2135 kN/m

MMAX = (1/8)WL2 = 0.0043 kN-m


VMAX = wL/2 = 0.0427 kN
CHECK FOR BENDING: To be safe, Fb > Fact

Fact = 6Mmax/bh2
= 0.10
Fb= 13.80 ****Since Fact is less than Fallowable, it is safe=)

CHECK FOR SHEAR; To be safe, Fv > Fvact

Fvact = (3/2)(Vmax/bh)
= 0.03
Fv= 1.34 ****Since Fvact is less than Fvallowable, it is safe=)

CHECK FOR DEFLECTION: To be safe, Yall > Yact

Yact = (5/384)(WLn4/EI) = 0.00375 mm


Yallow = L/360 = 1.11111 mm
****Since Yact is less than Yallowable, it is safe=)

THEREFORE USE 25 x 100 T&G

DESIGN OF FLOOR JOISTS

DATA:
Specific Gravity = 7.26 kN/m3
Modulus of Elasticity = 14600.0 MPa
Length of joist = 2.75 m
Joist Spacing = 0.50 m
Residential Live Load = 2.00 kPa

TRIAL DIMENSION:
50 x 175 mm
I= 2.23E+07 mm4
SECTION A-A: T&G

Floor Joist 0.18 m

0.50 m

0.05 m

Dead Loads:

Weight of joist = Specific Gravity X Area of Joist = 0.06352 Kn/m


Load carried by the T&G = 0.090743 Kn/m

Live Load:
Floor LL = 1 Kn/m

WDL+LL = 1.154262 Kn/m

MMAX = (1/8)WL2 = 1.091139 Kn-m


VMAX = wL/2 = 1.587111 Kn

CHECK FOR BENDING: To be safe, Fb > Fact

Fact = 6Mmax/bh2
= 4.275 Mpa
Fb= 13.80 Mpa ****Since Fact is less than Fallowable, it is safe=)

CHECK FOR SHEAR; To be safe, Fv > Fvact

Fvact = (3/2)(Vmax/bh)
= 0.27208 Mpa
Fv= 1.34 Mpa ****Since Fact is less than Fallowable, it is safe=)

CHECK FOR DEFLECTION: To be safe, Yall > Yact

Yact = (5/384)(WLn4/EI) = 2.64E+00 mm


Yallow = L/360 = 7.6388889 mm
****Since Yact is less than Yallowable, it is safe=)
THEREFORE USE 50 x 175 FLOOR JOISTS
CARMEL B. SABADO CE-164 PROF.Allan E. Milano
BSCE-5 Timber Excel Program
*note:the boxes in yellow should be inputed by the designer,while blue ones are computed by the program.=)

DESIGN OF GIRDER

DATA: TRIAL DIMENSION:


Specific Gravity = 5.40 kN/m 3
150 x 300 mm
Modulus of Elasticity = 9100.00 MPa I= 3.38E+08 mm4
Length of Girder = 2.75 MPa Weight of the girder: = Area X Specific Gravity
Joist Spacing = 0.40 m = 0.24282 kn-m
Residential Live Load = 2.00 kPa

1.587 kn 3.174221 3.174221 kn 3.174221 3.174221 3.174221 kn 1.587111

0.40 0.4 0.4 0.4 0.4 0.4

Weight
of girder

2.75 m

9.98 kn 9.98 kn

CHECK FOR BENDING: Mmax = 8.54 kn-m


Vmax = 9.98 kn
Fact = 6Mmax/bh2
= 3.7939084333 Mpa
Fb= 13.80 Mpa ****Since Fact is less than Fallowable, it is safe=)

CHECK FOR SHEAR;

Fvact = (3/2)(Vmax/bh)
= 0.3326666667 Mpa
Fv= 1.34 Mpa ****Since Fact is less than Fallowable, it is safe=)

CHECK FOR DEFLECTION:


2
5 wl4 Pa( 3 L−4 a ) PL 3 -2.03E+00 mm
Y actual= + +
384 EI 24 EI 48 EI
Yallow = L/360 7.6388888889 mm
****Since Yact is less than Yallowable, it is safe
DESIGN OF STAIRS

DESIGN OF TREAD

TRIAL DIMENSION: Loadings:


50 x 200 mm Weight of Tread = 0.05396 Kn
I= 3.33E+07 mm 4
Live Load = 0.4 Kn
TOTAL = 0.45396 Kn

WIDTH OF STAIRS= 1.1 m


in mm = 1100

Analytical Model:
w= 0.45396 Kn

1.1 m

MMAX = (1/8)WL2 = 0.068661 Kn-m


VMAX = wL/2 = 0.249678 Kn

CHECK FOR BENDING: To be safe, Fb > Fact

Fact = 6Mmax/bh2
= 0.20598435 Kn
Fb= 13.80 Kn ****Since Fact is less than Fallowable, it is safe=)

CHECK FOR SHEAR; To be safe, Fv > Fvact

Fvact = (3/2)(Vmax/bh)
= 0.0374517 Kn
Fv= 1.34 Kn ****Since Fact is less than Fallowable, it is safe=)

CHECK FOR DEFLECTION: To be safe, Yall > Yact

Yact = (5/384)(WLn4/EI) = 0.0285 mm


Yallow = L/360 = 0.003056 mm
****since this deflection is alrady in mm, it is very neglegible

THEREFORE USE 50 x 200 TREAD

DESIGN OF CARRIAGE

TRIAL DIMENSION:
50 x 200 mm
I= 3.33E+07 mm 4

Considering the longest span of the stairs:

No. of Stairs = 18 @ 0.2 m


Load carried by the tre = 0.45396 Kn

Theta, q = 36.8699
Length of Carriage = 4.5 m
Weigth of Carriage = 0.05396 Kn

Analytical Model:

2.7
m

Theta, q = 36.8699
3.6 m

w= 0.41 Kn/m

L= 4.50 m

concrete landing

Load by the Tread: Weight of Carriage:

0.363 0.272376 0.032376


0.45396 0.043168
0.05396

MMAX = 1/2WL2 = 4.11 Kn-m


VMAX = wL/2 = 0.914256 Kn

CHECK FOR BENDING: To be safe, Fb > Fact

Fact = 6Mmax/bh2
= 12.342456 Kn
Fb= 13.80 Kn ****Since Fact is less than Fallowable, it is safe

CHECK FOR SHEAR; To be safe, Fv > Fvact

Fvact = (3/2)(Vmax/bh)
= 0.1371384 Kn
Fv= 1.34 Kn ****Since Fact is less than Fallowable, it is safe

CHECK FOR DEFLECTION: To be safe, Yall > Yact


Yact = (5/384)(WLn4/EI) = 4.70E+00
Yallow = L/360 = 12.5 ****Since Yact is more than Yallowable, not safe

THEREFORE USE 50 x 200 CARRIAGE