Вы находитесь на странице: 1из 44

Set Free Sigma

THE NEXT GENERATION VRF


Cooling & Heating
HITACHI
5
YEAR
WARRANTY

SET FREE SIGMA


INDEX

04 Design Flexibility 32 Ducted (Slim) Indoor Units


08 Adaptability 33 Ducted (Low Height) Indoor Units
11 High Efficiency 34 Ducted (Standard) Indoor Units
18 Technical specification 35 Ducted (Large Capacity) Indoor Units
25 Sustainability 36 Ceiling Suspended Indoor Units
27 Wall Mounted Indoor Units 37 Hydro Free
28 Floor Mounted Indoor Units 38 Control Systems & Accessories
29 2-Way Cassette Indoor Units
30 4-Way Mini Cassette Indoor Units
31 4-Way Cassette Hi Efficiency Indoor Units

The information contained herein must be checked in the relevant technical catalogues
Design Flexibility

DESIGN FLEXIBILITY

SINGLE MODULE UP TO 24HP


HP 5-6 8 - 12 14 - 18 20 - 24 26 - 48 50 - 54
Cooling capacity (kW) 14.0 - 16.0 22.4 - 33.5 40.0 - 50.0 73.0 - 90.0 73.0 - 136.0 140.0 - 150.0

Series S
(RAS-FSXNSE)
Single module Single module Single module Dual module Triple module
HP 5-6 8 - 14 16 - 18 20 - 36 38 - 54

Series P
(RAS-FSXNPE)
Single module Single module Single module Dual Module Triple Module

Increase of the single-module versions for EUROVENT Certification

Compact modules (compared to the previous series)

New

Space
-11% Weight
SIGMA
-16%
reduction on reduction on
average average

18HP Space 24HP Space


50.0kW
New
SIGMA
Previous
series -37% 67.0kW
New
SIGMA
Previous
series -27%
Weight Weight
1,210 mm
1,920 mm
-29% 1,600 mm
2,180 mm
-32%
Space: 1.47 m2 0.93 m2 Space: :1.67 m2 1.22 m2
Weight: 445 kg 315 kg Weight: 540 kg 365 kg

42HP 54HP
New Previous New Previous
118.0kW SIGMA series 150.0kW SIGMA series

2,830 mm 3,670 mm
3,410 mm 4,380 mm

Space: 2.61 m2 2.16 m2 Space: 3.35 m2 2.81 m2


Weight: 850 kg 676 kg Weight: 1.080 kg 933 kg
Space Weight Space Weight
-17% -20% -16% -14%

4
Design Flexibility

EASY TRANSPORTATION

Smaller Lighter

Can be transported
in a lift by pallet jack Lift Crane
( up to 18HP) 800 mm

1210 mm

765 mm

1350 mm

IMPROVED STATIC PRESSUE


High static pressure for outdoor units: can handle up to 80Pa.

Current Model New Sigma

60Pa 80Pa

offers more options for


the indoor installation of
the outdoor unit

• Less piping length


• Lower installation cost
• Visual aesthetics

Outdoor unit Outdoor unit

5
Design Flexibility

DESIGN FLEXIBILITY

FLEXIBITY OF THE REFRIGERATION CIRCUIT


Total piping length 1000m

Longest lengh actual (equivalent) 165m (190m)

Longest length after first branch 90m*


top connection standard 50m and optional 110m*
Level difference between ODU and IDU
bottom connection 40m
Level difference between IDUs 30m

* Check the indications given in the technical catalog

• Suitable for buildings up to


Up to 110 m *

100m in height
• Leads to cost/time saving for
designers, with more efficient
30 m

design.

90m

190m

6
Design Flexibility

OPERATION TEMPERATURE RANGE


Up to
Cooling Capacity Range °C DB -10 up to 52 +9°C

Heating Capacity Range °C WB -20 up to 15

-5°C
-5°C 0 0
-10°C 52°C
48°C
52°C
48°C -20°C
-20°C
-20°C
-20 °C 00 15°C
15°C
15°C
15°C

Cooling 1 Cooling mode Heating Heating mode

NOTE:
1. Operation up to -10°C DB with low ambient setting and up to 52°C DB for the Premium version

IDU COMBINATIONS RANGE


Expansion of number of connectable indoor units

Up to
150%

38HP (106.0kW) 64 units maximum

Outdoor Unit Capacity (HP) 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38-54

Cooling Capacity (kW) 14.0 16.0 22.4 28.0 33.5 40.0 45.0 50.0 56.0 61.5 67.0 73.0 77.5 85.0 90.0 95.0 100.0 106.0-150.0

Index Load High Efficiency series: 50 up to 150%

Maximum Connectable IDU 16 19 26 32 39 45 52 58 64 64 64 64 64 64 64 64 64 64

7
Adaptability

ADAPTABILITY

LOW NOISE OPERATION


Thanks to the modifications on the compressor and on the exhaust fan

Sound Power Level dB(A)


-1.5dB(A)
Capacity (HP) 8 10 12 14 16 20 22 24 on average!
Cooling Capacity(kW) 22.4 28.0 33.5 40.0 45.0 56.0 61.5 67.0 Reduction of
High Efficiency Models 77 82 83 85 85 85 86 86 sound power

Compressor Fans
The new Scroll compressor larger than the The fans were inserted above the heat exchanger
previous version is incorporated into a shell that allows and completely incorporated into the external structure. This
to reduce the sound level up to -2dB (A). limits the propagation of sound waves.

New New
cover design

SILENT MODE TWIN SCROLL COMPRESSOR


In special applications, the most stringent environmental Inside the Standard and Premium units with higher powers
restrictions can be respected thanks to the possibility of changing at 16 HP (45.0 kW) two new Scroll compressors are used
the sound performance by adapting it on three different levels. for each module. The electronic control ensures departure
The Silent Mode function can be accessed from the external unit in sequence avoiding the related absorption problems
card or using specific BMS management systems to contemporary start-ups.

Day Night Day


Sound
Power
Level New
feature

86dB(A) 72.5dB(A) 86dB(A)


Nominal Step2 Nominal

86dB(A) Nominal 72.5dB(A) Step2

dB(A)
18HP (50.0kW) 42HP (118.0kW)
Noise Reduction mode Sound Power Level Sound Power Level

Nominal 86 89

Step 1 82.5 86

Step 2 77.5 81

Step 3 72.5 76

8
Adaptability

DEFROSTING
Prevention Improved!
For defrost prevention, the model controls frost and ice formation
during the heating operation by running mid-temperature
coolant (5°C-20°C) before decreasing the pressure through a heat
exchanger to control frost and ice formation on the lower part of frost
the outdoor heat exchanger.

defrosting

MORE EFFICIENT DEFROSTING Standard and High Efficiency Models

The defrost interval is increased by more than 200%, extending it Comfortably


from 120 to 250 minutes, this means that in an hour of operation, maintained
Temperatura ambiente

temperature
with defrost included, the average thermal power available to
the inside is equal to 80% of the capacity thermal available.

Heating
+ 200%

on off on off on

No cold air flow to Indoor


thanks to automatic IDU step

9
Adaptability

ADAPTABILITY

SERVICE CONTINUITY IN CASE OF EMERGENCY


Prevention Backup Function
Distribution of the workload of the compressors and the In case of interruption of the operation of a module, the remaining
timing of their operation are guaranteed automatically by the ones can continue to operate using the other units, thus avoiding
programming of the electronic card of the single module and the whole system to stop.
thus reduces the possible operating imbalances.

off on on
Combined ODUs

Rotation

on on off on off on

EASE OF MAINTENANCE
Completely redesigned structure Totally
redesigned
New Concept
In the upper section, all PCBs are
visible and easily accessible

Newly adopted window for


7-segment display
A dedicated access door leads to
easy access to 7-segment display,
PSW & DSW and so on without
interfering with the operation of
the system.
apertura

New Panel New DSW setting for


The upper panel (on the side of an Refrigerant pump-down:
electric box) can be independently Refrigerant evacuation: Enforced
detached from the lower panel (on New Structure operation to open ODU EVO/EVB,
More Space in lower section, easy
the compressor chamber side) IDU EVI, and Hi/Low pressure Bi-
access to compressors or valves pass SVB

10
High Efficiency

HIGH EFFICIENCY

LARGE VENTILATION SURFACE

Thanks to the double fan solution

Double Fans Controlled Air Flow

Smoother
air flow

Increased
height

Reduction of air
vortexes
1210 mm

Air volume area : 6334 cm2


Increased area
+40%

• Improvement of 23% of air flow per module


• Reduction on average of 20% in energy consumption in the driving shaft

IMPROVED HEAT EXCHANGER


New SIGMA design

14-24HP Standard series (40.0-67.0kW)


14-24HP (40.0-67.0kW)
8-18HP High Efficiency series (22.4-50.0kW)

Split left-right
Improved angle
heat exchanger
of the curve

Σ SIGMA
design

•The heat exchange area has been increased by more than 10% (single module)
• Greater heat exchange efficiency

11
High Efficiency

HIGH EFFICIENCY

NEW COMPRESSOR
New Design

Fixed Scroll

By-pass
Valve
Orbiting
Including 13 new components!
Scroll

Main
Oldham's
Bearing
Coupling
Thrust
Bearing

Frame Seal Compressor performance


Crankshaft increased by
+4.6 %
Counterweight

Motor Rotor
104.6%
Motor Stator
100.0%

Sub
Bearing

Oil Pump
Previous model New SIGMA

Greater capacity control Previous model* New SIGMA*


Better performance and an increase of
energy savings were obtained thanks to a 15Hz ~ 100Hz 11Hz ~ 110Hz
100% 100% 100% 100%
newly designed and high efficiency Scroll 85 Steps
990 Steps
DC inverter compressor, able to follow (by 1Hz) (by 0.1Hz)
Inverter Compressor

Inverter Compressor
Inverter Compressor

Inverter Compressor

increments of 0.1 Hz of frequency of the


Control Capacity

Control Capacity
Control Capacity

Control Capacity

inverter.
Another feature is the dramatically
extended working range that allows DC DC DC DC
InverterInverter InverterInverter
modulation and ignition even when the Compressor
Compressor Compressor
Compressor
smallest indoor unit of 0.4 HP (1.1 kW) 20% 20% 10% 10%
requires it. Max. Max. CoolingCooling
Max. Max. Load Load Min.
CoolingCooling Min.
Load Load Min. Min.

*Example at 12HP (33.5kW)

12
High Efficiency

IMPROVED COMPRESSOR CONTROL Transfer of the correct


refrigerant charge
Smooth Drive Control to the internal units Refrigerant flow
The outdoor unit calculates the amount of
refrigerant necessary to meet the demands
of each individual indoor unit and send the
exact quantity to the single unit; it also adjusts
the speed of the compressor according to the DC Scroll inverter
changed working conditions every 30 seconds. compressor

Each indoor unit receives exactly the required


refrigerant thus ensuring a regular and Transmit Transmit
load information load information
continuous operation to obtain constant
comfort in the environment.
The compressor, capable of modulating at very Bus H-Link II
low speeds, will no longer have repeated phases
of switching on and off meaning improved
energy savings. Calculation of proper
refrigerant amount

Previous model New SIGMA

Hitachi
Original

Room 30 Room 30
temperature
Temp (°C) (°C)
25 25
Unstable Temperature Constant Room Temperature
20 20

15 15

10 10
Energy Consuption Loss
5
5 Smooth Drive control
Power Power
(kW) (kW) 0
0 60 120 180
60 120 180 Tempo (min)
Time(min)

RoomTemperature (°C) Room temperature (°C)


Power (kW)
Power(kW)

Low load operation -40%


with repeated on / off less energy consumption

13
High Efficiency

HIGH EFFICIENCY

IMPROVEMENT OF EFFICIENCY IN PARTITIONING IN COOLING


The heat exchanger divided into two sections, upper part and lower part, allows to change the geometry of the exchanger according to
the required performance. In partialization mode this variable geometry directs the fluid through a narrow path that causes an increase in
refrigerant speed and a consequent increase in thermal conductivity.

(ph Diagram Conceptual Drawing)

Saturation
Condense Curve

Pressure:
Expand Compressor
p (Mpa)

Evaporate

Cooling Capacity

Enthalpy: h (kJ/kg)

Exchanger
Entrance

Direction
The refrigerant is of refrigerant
sent to a narrower
part of the heat
exchanger, which is
divided into the
upper and lower
part, thus increasing
Upper
the speed
Lower
Exit

Indoor Unit
Compressor
Increased refrigerant
speed and increased
thermal conductivity

14
HIGH EFFICIENCY

SMART REFRIGERANT TEMPERATURE CONTROL


For highly efficient seasonal operation the system will automatically adjust the target evaporating temperature of the indoor unit coil to reflect
the exact load at that given time.
As a space approaches its set temperature, the air onto the coil cools down and therefore its cooling requirement decreases. By automatically
increasing the evaporating temperature to reflect this changing environment the load on the compressor can be dramatically reduced leading
to considerably higher efficiency levels and running cost savings.

Evaporation Temperature is Variable


Inlet Air

Previous p
Trend of deviation
Temp. {No Control Target)
Current TLave* depends on
(ºC)
Set Temp. the cooling load
Deviation

Period of Control

Time (t) h

* TLave: Average of the Liquid sensor temperatures of the IDUs (Evaporation Temporature)

COLD DRAUGHT PREVENTION


Smart refrigerant temperature control automatically adjusts the air off temperature for optimum comfort levels for users. Individual users can
select their own tailored evaporating temperatures from the remote controls or let the system work automatically.

Minimum blown air User Energy Cooling


temprature Comfort Consumption Capacity

Std 100% Optimum


8°C comfort for
12°C S td 76% users

14°C - 15% 65%


16°C -30% 53%

15
High Efficiency

HIGH EFFICIENCY

SEASONAL EFFICIENCY

5 – 14 HP

16 – 24 HP

16
High Efficiency

HIGH EFFICIENCY

SEASONAL EFFICIENCY

26 – 38 HP

40 – 54 HP

17
Technical Specifications

SET FREE SIGMA


STANDARD SERIES RAS 8FSXNSE RAS 10FSXNSE RAS 12FSXNSE RAS 14FSXNSE RAS 16FSXNSE
Nominal Cooling Capacity kW 22,4 28,0 33,5 40,0 45,0

Nominal Heating Capacity kW 25,0 31,5 37,5 45,0 50,0

EER 4,15 3,85 3,77 3,30 3,25

SEER 7,50 7,17 6,97 7,47 7,30

COP 4,75 4,57 4,10 3,74 3,37

SCOP 4,17 4,11 4,29 4,48 4,42

Scroll Compressor type/n. Inverter x 1 Inverter x 1 Inverter x 1 Inverter x 1 Inverter x 2

Connection Data 2 pipe Gas mm (in) 19,05 (3/4) 22,2 (7/8) 25,4 (1) 25,4 (1) 28,58 (1-1/8)

Liquid mm (in) 9,52 (3/8) 9,52 (3/8) 12,7 (1/2) 12,7 (1/2) 12,7 (1/2)

3 pipe Gas HP mm (in) 15,88 (5/8) 19,05 (3/4) 22,2 (7/8) 22,2 (7/8) 22,2 (7/8)

Gas LP mm (in) 19,05 (3/4) 22,2 (7/8) 25,4 (1) 25,4 (1) 28,58 (1-1/8)

Liquid mm (in) 9,52 (3/8) 9,52 (3/8) 12,7 (1/2) 12,7 (1/2) 12,7 (1/2)

Maximum no. indoor units n 26 32 39 45 52

Load Index % HP 50 ÷ 130

Sound Power (preliminary data) dB(A) 80 82 82 85 85

Sound Pressure (preliminary data) dB(A) 58 60 59 63 63

Dimensions (H x W x D) mm 1725x959x784 1725x959x784 1725x959x784 1725x1219x784 1725x1219x784

Weight kg 210 210 233 289 332

Power Supply phase/V/Hz 3N / 400 / 50

Operating Range Heating °C -10 ÷ +48

Cooling °C -20 ÷ +15

Air Flow m3/min 165 170 190 239 256

Number of Fans n° 1 1 1 2 2

Static Pressure Pa (max) Pa 80

SET FREE SIGMA RAS 26FSXNSE


STANDARD SERIES RAS 18FSXNSE RAS 20FSXNSE RAS 22FSXNSE RAS 24FSXNSE
(RAS 12FSXNSE
+ RAS 14FSXNSE)
Nominal Cooling Capacity kW 50,0 56,0 61,5 67,0 73,0

Nominal Heating Capacity kW 56,0 63,0 69,0 77,5 82,5

EER 3,35 3,01 3,01 2,99 3,12

SEER 6,96 6,29 6,76 6,20 7,30

COP 3,29 3,35 3,19 3,40 3,90

SCOP 4,18 4,14 4,43 4,43 4,39

Scroll Compressor type/n. Inverter x 2 Inverter x 2 Inverter x 2 Inverter x 2 Inverter x 2

Connection Data 2 pipe Gas mm (in) 28,58 (1-1/8) 28,58 (1-1/8) 28,58 (1-1/8) 28,58 (1-1/8) 31,75 (1-1/4)

Liquid mm (in) 15,88 (5/8) 15,88 (5/8) 15,88 (5/8) 15,88 (5/8) 19,05 (3/4)

3 pipe Gas HP mm (in) 22,2 (7/8) 22,2 (7/8) 25,4 (1) 25,4 (1) 25,4 (1)

Gas LP mm (in) 28,58 (1-1/8) 28,58 (1-1/8) 28,58 (1-1/8) 28,58 (1-1/8) 31,75 (1-1/4)

Liquid mm (in) 15,88 (5/8) 15,88 (5/8) 15,88 (5/8) 15,88 (5/8) 19,05 (3/4)

Maximum no. indoor units n 58 64 64 64 64

Load Index % HP 50 ÷ 130

Sound Power (preliminary data) dB(A) 86 86 84 86 87

Sound Pressure (preliminary data) dB(A) 65 65 64 66 64,5

Dimensions (H x W x D) mm 1725x1219x784 1725x1609x784 1725x1609x784 1725x1609x784 1725x2198x784

Weight kg 333 382 396 397 233+289

Power Supply phase/V/Hz 3N / 400 / 50

Operating Range Heating °C -10 ÷ +48

Cooling °C -20 ÷ +15

Air Flow m3/min 256 329 329 348 190 + 239

Number of Fans n° 2 2 2 2 3

Static Pressure Pa (max) Pa 80

18
Technical Specifications

SET FREE SIGMA RAS 28FSXNSE RAS 30FSXNSE RAS 32FSXNSE RAS 34FSXNSE RAS 36FSXNSE
STANDARD SERIES (RAS 12FSXNSE
+ RAS 16FSXNSE)
(RAS 12FSXNSE
+ RAS 18FSXNSE)
(RAS 14FSXNSE
+ RAS 18FSXNSE)
(RAS 16FSXNSE
+ RAS 18FSXNSE)
(RAS 18FSXNSE
+ RAS 18FSXNSE)
Nominal Cooling Capacity kW 77,5 85,0 90,0 95,0 100,0

Nominal Heating Capacity kW 90,0 95,0 100,0 106,0 112,0

EER 3,45 3,51 3,04 3,30 3,35

SEER 7,10 7,11 7,36 7,18 7,20

COP 3,65 3,57 3,48 3,33 3,29

SCOP 4,35 4,22 4,30 4,28 4,18

Scroll Compressor type/n. Inverter x 3 Inverter x 3 Inverter x 3 Inverter x 4 Inverter x 4

Connection Data 2 pipe Gas mm (in) 31,75 (1-1/4) 31,75 (1-1/4) 31,75 (1-1/4) 31,75 (1-1/4) 38,1 (1-1/2)

Liquid mm (in) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4)

3 pipe Gas HP mm (in) 28,58 (1-1/8) 28,58 (1-1/8) 28,58 (1-1/8) 28,58 (1-1/8) 28,58 (1-1/8)

Gas LP mm (in) 31,75 (1-1/4) 31,75 (1-1/4) 31,75 (1-1/4) 31,75 (1-1/4) 38,1 (1-1/2)

Liquid mm (in) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4)

Maximum no. indoor units n 64 64 64 64 64

Load Index % HP 50 ÷ 130

Sound Power (preliminary data) dB(A) 87 87 89 89 89

Sound Pressure (preliminary data) dB(A) 64,5 66 67 67 68

Dimensions (H x W x D) mm 1725x2198x784 1725x2198x784 1725x2458x784 1725x2458x784 1725x2458x784

Weight kg 233+332 233+333 289 + 333 332 + 333 333 + 333

Power Supply phase/V/Hz 3N / 400 / 50

Operating Range Heating °C -10 ÷ +48

Cooling °C -20 ÷ +15

Air Flow m3/min 190 + 256 190 + 256 239 + 256 256 X 2 256 X 2

Number of Fans n° 3 3 4 4 4

Static Pressure Pa (max) Pa 80

SET FREE SIGMA RAS 38FSXNSE RAS 40FSXNSE RAS 42FSXNSE RAS 44FSXNSE RAS 46FSXNSE
STANDARD SERIES (RAS 14FSXNSE
+ RAS 24FSXNSE)
(RAS 18FSXNSE
+ RAS 22FSXNSE)
(RAS 18FSXNSE
+ RAS 24FSXNSE)
(RAS 22FSXNSE
+ RAS 22FSXNSE)
(RAS 22FSXNSE
+ RAS 24FSXNSE)
Nominal Cooling Capacity kW 106,0 112,0 118,0 122,0 128,0

Nominal Heating Capacity kW 118,0 125,0 132,0 140,0 145,0

EER 2,89 3,15 3,13 3,01 3,00

SEER 6,63 6,93 6,57 6,75 6,45

COP 3,52 3,23 3,35 3,19 3,30

SCOP 4,45 4,30 4,31 4,43 4,43

Scroll Compressor type/n. Inverter x 3 Inverter x 4 Inverter x 4 Inverter x 4 Inverter x 4

Connection Data 2 pipe Gas mm (in) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2)

Liquid mm (in) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4)

3 pipe Gas HP mm (in) 31,75 31,75 31,75 31,75 31,75

Gas LP mm (in) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2)

Liquid mm (in) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4)

Maximum no. indoor units n 64 64 64 64 64

Load Index % HP 50 ÷ 130

Sound Power (preliminary data) dB(A) 89 88 89 87 88

Sound Pressure (preliminary data) dB(A) 68 67,5 68,5 67 68

Dimensions (H x W x D) mm 1725x2848x784 1725x2848x784 1725x2848x784 1725x3238x784 1725x3238x784

Weight kg 289 + 397 333 + 396 333 + 397 396 + 396 396 + 397

Power Supply phase/V/Hz 3N / 400 / 50

Operating Range Heating °C -10 ÷ +48

Cooling °C -20 ÷ +15

Air Flow m3/min 239 + 348 256 + 329 256 + 348 329 X 2 329 + 348

Number of Fans n° 4 4 4 4 4

Static Pressure Pa (max) Pa 80

19
Technical Specifications

RAS 50FSXNSE RAS 52FSXNSE RAS 54FSXNSE


SET FREE SIGMA RAS 48FSXNSE (RAS 14FSXNSE (RAS 16FSXNSE (RAS 18FSXNSE
STANDARD SERIES (RAS 24FSXNSE
+ RAS 24FSXNSE)
+ RAS 18FSXNSE
+ RAS 18FSXNSE)
+ RAS 18FSXNSE
+ RAS 18FSXNSE)
+ RAS 18FSXNSE
+ RAS 18FSXNSE)
Nominal Cooling Capacity kW 136,0 140,0 145,0 150,0

Nominal Heating Capacity kW 150,0 155,0 160,0 165,0

EER 2,99 3,15 3,32 3,35

SEER 6,19 7,30 7,18 7,20

COP 3,40 3,41 3,31 3,29

SCOP 4,43 4,26 4,25 4,18

Scroll Compressor type/n. Inverter x 4 Inverter x 5 Inverter x 6 Inverter x 6

Connection Data 2 pipe Gas mm (in) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2)

Liquid mm (in) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4)

3 pipe Gas HP mm (in) 31,75 31,75 31,75 31,75

Gas LP mm (in) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2)

Liquid mm (in) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4)

Maximum no. indoor units n 64 64 64 64

Load Index % HP 50 ÷ 130

Sound Power (preliminary data) dB(A) 89 90 90 91

Sound Pressure (preliminary data) dB(A) 69 69 69 70

Dimensions (H x W x D) mm 1725x3238x784 1725x3697x784 1725x3697x784 1725x3697x784

Weight kg 397 + 397 289 + 333 + 333 332 + 333 + 333 333 + 333 + 333

Power Supply phase/V/Hz 3N / 400 / 50

Operating Range Heating °C -10 ÷ +48

Cooling °C -20 ÷ +15

Air Flow m3/min 348 X 2 239 + 256 X 2 256 X 3 256 X 3

Number of Fans n° 4 6 6 6

Static Pressure Pa (max) Pa 80

SET FREE SIGMA


HIGH EFFICIENCY SERIES RAS 5FSXNPE RAS 6FSXNPE RAS 8FSXNPE RAS 10FSXNPE RAS 12FSXNPE
Nominal Cooling Capacity kW 14,0 16,0 22,4 28,0 33,5

Nominal Heating Capacity kW 16,0 18,0 25,0 31,5 37,5

EER 4,82 4,75 4,44 4,53 3,97

SEER 8,33 8,00 7,97 8,06 7,91

COP 5,72 5,12 4,92 4,74 4,68

SCOP 5,06 4,58 4,55 4,73 4,81

Scroll Compressor type/n. Inverter x 1 Inverter x 1 Inverter x 1 Inverter x 1 Inverter x 1

Connection Data 2 pipe Gas mm (in) 15,88 (5/8) 19,05 (3/4) 19,05 (3/4) 22,2 (7/8) 25,4 (1)

Liquid mm (in) 9,52 (3/8) 9,52 (3/8) 9,52 (3/8) 9,52 (3/8) 12,7 (1/2)

3 pipe Gas HP mm (in) 12,7 (1/2) 15,88 (5/8) 15,88 (5/8) 19,05 (3/4) 22,2 (7/8)

Gas LP mm (in) 15,88 (5/8) 19,05 (3/4) 19,05 (3/4) 22,2 (7/8) 25,4 (1)

Liquid mm (in) 9,52 (3/8) 9,52 (3/8) 9,52 (3/8) 9,52 (3/8) 12,7 (1/2)

Maximum no. indoor units n 16 19 26 32 39

Load Index % HP 50 ÷ 150

Sound Power (preliminary data) dB(A) 75 78 77 82 83

Sound Pressure (preliminary data) dB(A) 54 56 55 59 60

Dimensions (H x W x D) mm 1725x959x784 1725x959x784 1725x1219x784 1725x1219x784 1725x1219x784

Weight kg 210 210 274 278 282

Power Supply phase/V/Hz 3N / 400 / 50

Operating Range Heating °C -10 ÷ +52

Cooling °C -20 ÷ +15

Air Flow m3/min 150 170 185 219 219

Number of Fans n° 1 1 2 2 2

Static Pressure Pa (max) Pa 80

20
Technical Specifications

SET FREE SIGMA RAS 20FSXNPE RAS 22FSXNPE


HIGH EFFICIENCY SERIES RAS 14FSXNPE RAS 16FSXNPE RAS 18FSXNPE
(RAS 10FSXNPE
+ RAS 10FSXNPE)
(RAS 10FSXNPE
+ RAS 12FSXNPE)
Nominal Cooling Capacity kW 40,0 45,0 50,0 56,0 61,5

Nominal Heating Capacity kW 45,0 50,0 56,0 63,0 69,0

EER 3,47 3,91 3,91 4,53 4,21

SEER 7,69 7,76 7,6 8,06 7,97

COP 4,15 3,87 3,74 4,74 4,71

SCOP 4,63 4,84 4,81 4,76 4,76

Scroll Compressor type/n. Inverter x 1 Inverter x 2 Inverter x 2 Inverter x 2 Inverter x 2

Connection Data 2 pipe Gas mm (in) 25,4 (1) 28,58 (1-1/8) 28,58 (1-1/8) 28,58 (1-1/8) 28,58 (1-1/8)

Liquid mm (in) 12,7 (1/2) 12,7 (1/2) 15,88 (5/8) 15,88 (5/8) 15,88 (5/8)

3 pipe Gas HP mm (in) 22,2 (7/8) 22,2 (7/8) 22,2 (7/8) 22,2 (7/8) 25,4 (1)

Gas LP mm (in) 25,4 (1) 28,58 (1-1/8) 28,58 (1-1/8) 28,58 (1-1/8) 28,58 (1-1/8)

Liquid mm (in) 12,7 (1/2) 12,7 (1/2) 15,88 (5/8) 15,88 (5/8) 15,88 (5/8)

Maximum no. indoor units n 45 52 58 64 64

Load Index % HP 50 ÷ 150

Sound Power (preliminary data) dB(A) 85 85 86 85 86

Sound Pressure (preliminary data) dB(A) 62 65 65 62 62,5

Dimensions (H x W x D) mm 1725x1219x784 1725x1609x784 1725x1609x784 1725x1609x784 1725x2458x784

Weight kg 292 369 384 278+278 278+282

Power Supply phase/V/Hz 3N / 400 / 50

Operating Range Heating °C -10 ÷ +52

Cooling °C -20 ÷ +15

Air Flow m3/min 243 326 362 219 X 2 219 X 2

Number of Fans n° 2 2 2 4 4

Static Pressure Pa (max) Pa 80

SET FREE SIGMA RAS 24FSXNPE RAS 26FSXNPE RAS 28FSXNPE RAS 30FSXNPE RAS 32FSXNPE
HIGH EFFICIENCY SERIES (RAS 12FSXNPE
+ RAS12FSXNPE)
(RAS 10FSXNPE
+ RAS 16FSXNPE)
(RAS 12FSXNPE
+ RAS 16FSXNPE)
(RAS 12FSXNPE
+ RAS 18FSXNPE)
(RAS 14FSXNPE
+ RAS 18FSXNPE)
Nominal Cooling Capacity kW 67,0 73,0 77,5 85,0 90,0

Nominal Heating Capacity kW 77,5 82,5 90,0 95,0 100,0

EER 3,97 4,13 3,94 3,93 3,70

SEER 7,91 7,92 7,71 7,43 7,62

COP 4,68 4,17 4,18 4,07 3,91

SCOP 4,81 4,78 4,82 4,71 4,63

Scroll Compressor type/n. Inverter x 2 Inverter x 3 Inverter x 3 Inverter x 3 Inverter x 3

Connection Data 2 pipe Gas mm (in) 28,58 (1-1/8) 31,75 (1-1/4) 31,75 (1-1/4) 31,75 (1-1/4) 31,75 (1-1/4)

Liquid mm (in) 15,88 (5/8) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4)

3 pipe Gas HP mm (in) 25,4 (1) 25,4 (1) 28,58 (1-1/8) 28,58 (1-1/8) 28,58 (1-1/8)

Gas LP mm (in) 28,58 (1-1/8) 31,75 (1-1/4) 31,75 (1-1/4) 31,75 (1-1/4) 31,75 (1-1/4)

Liquid mm (in) 15,88 (5/8) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4)

Maximum no. indoor units n 64 64 64 64 64

Load Index % HP 50 ÷ 150

Sound Power (preliminary data) dB(A) 86 87 87 88 89

Sound Pressure (preliminary data) dB(A) 63 66 66 66 67

Dimensions (H x W x D) mm 1725x2458x784 1725x2458x784 1725x2848x784 1725x2848x784 1725x2848x784

Weight kg 282+282 278+369 282 + 369 282 + 384 292 + 384

Power Supply phase/V/Hz 3N / 400 / 50

Operating Range Heating °C -10 ÷ +52

Cooling °C -20 ÷ +15

Air Flow m3/min 219 X 2 219 + 326 219 + 326 219 + 362 243 + 362

Number of Fans n° 4 4 4 4 4

Static Pressure Pa (max) Pa 80

21
Technical Specifications

RAS 42FSXNPE
SET FREE SIGMA RAS 34FSXNPE RAS 36FSXNPE
RAS 38FSXNPE
(RAS 12FSXNPE
RAS 40FSXNPE
(RAS 12FSXNPE (RAS 14FSXNPE
HIGH EFFICIENCY SERIES (RAS 16FSXNPE
+ RAS 18FSXNPE)
(RAS 18FSXNPE
+ RAS 18FSXNPE)
+ RAS 12FSXNPE
+ RAS 14FSXNPE)
+ RAS 14FSXNPE
+ RAS 14FSXNPE)
+ RAS 14FSXNPE
+ RAS 14FSXNPE)
Nominal Cooling Capacity kW 95,0 100,0 106,0 112,0 118,0

Nominal Heating Capacity kW 106,0 112,0 118,0 125,0 132,0

EER 3,91 3,91 3,77 3,60 3,47

SEER 7,83 7,6 7,67 7,67 7,67

COP 3,80 3,74 4,47 4,29 4,15

SCOP 4,72 4,64 4,74 4,68 4,63

Scroll Compressor type/n. Inverter x 4 Inverter x 4 Inverter x 3 Inverter x 3 Inverter x 3

Connection Data 2 pipe Gas mm (in) 31,75 (1-1/4) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2)

Liquid mm (in) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4)

3 pipe Gas HP mm (in) 28,58 (1-1/8) 28,58 (1-1/8) 31,75 31,75 31,75

Gas LP mm (in) 31,75 (1-1/4) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2)

Liquid mm (in) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4)

Maximum no. indoor units n 64 64 64 64 64

Load Index % HP 50 ÷ 150

Sound Power (preliminary data) dB(A) 89 89 89 89 90

Sound Pressure (preliminary data) dB(A) 68 68 65,5 66 67

Dimensions (H x W x D) mm 1725x3238x784 1725x3238x784 1725x3697x784 1725x3697x784 1725x3697x784

Weight kg 369 + 384 384 + 384 282 + 282 + 292 282 + 282 + 292 282 + 282 + 292

Power Supply phase/V/Hz 3N / 400 / 50

Operating Range Heating °C -10 ÷ +52

Cooling °C -20 ÷ +15

Air Flow m3/min 326 + 362 362 X 2 219 X 2 + 243 219 + 243 X 2 243 X 3

Number of Fans n° 4 4 6 6 6

Static Pressure Pa (max) Pa 80

SET FREE SIGMA RAS 44FSXNPE


(RAS 12FSXNPE
RAS 46FSXNPE
(RAS 14FSXNPE
RAS 48FSXNPE RAS 50FSXNPE RAS 52FSXNPE RAS 54FSXNPE
HIGH EFFICIENCY SERIES + RAS 14FSXNPE + RAS 14FSXNPE
(RAS 12FSXNPE
+ RAS 18FSXNPE
(RAS 14FSXNPE
+ RAS 18FSXNPE
(RAS 16FSXNPE
+ RAS 18FSXNPE
(RAS 18FSXNPE
+ RAS 18FSXNPE
+ RAS 18FSXNPE) + RAS 18FSXNPE) + RAS 18FSXNPE) + RAS 18FSXNPE) + RAS 18FSXNPE) + RAS 18FSXNPE)
HIGH EFFICIENCY SERIES kW 122,0 128,0 136,0 140,0 145,0 150,0

Nominal Heating Capacity kW 140,0 145,0 150,0 155,0 160,0 165,0

EER 3,77 3,63 3,92 3,77 3,91 3,91

SEER 7,64 7,64 7,61 7,61 7,75 7,60

COP 4,09 3,98 3,94 3,85 3,78 3,74

SCOP 4,68 4,63 4,68 4,64 4,70 4,64

Scroll Compressor type/n. Inverter x 4 Inverter x 4 Inverter x 5 Inverter x 5 Inverter x 6 Inverter x 6

Connection Data 2 pipe Gas mm (in) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2)

Liquid mm (in) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4)

3 pipe Gas HP mm (in) 31,75 31,75 31,75 31,75 31,75 31,75

Gas LP mm (in) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2) 38,1 (1-1/2)

Liquid mm (in) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4) 19,05 (3/4)

Maximum no. indoor units n 64 64 64 64 64 64

Load Index % HP 50 ÷ 150

Sound Power (preliminary data) dB(A) 90 90 90 90 90 91

Sound Pressure (preliminary data) dB(A) 67,5 68 68,5 69 70 70

Dimensions (H x W x D) mm 1725x4087x784 1725x4087x784 1725x4477x784 1725x4477x784 1725x4867x784 1725x4867x784

Weight kg 282 + 292 + 384 292 + 292 + 384 282 + 282 + 384 292 + 384 + 384 369 + 384 + 384 384 + 384 + 384

Power Supply phase/V/Hz 3N / 400 / 50

Operating Range Heating °C -10 ÷ +52

Cooling °C -20 ÷ +15

Air Flow m3/min 219 + 243 + 362 243 X 2 + 362 219 + 362 X 2 243 + 362 X 2 326 + 362 X 2 362 X 3

Number of Fans n° 6 6 6 6 6 6

Static Pressure Pa (max) Pa 80

22
Technical Specifications

Set Free Sigma Standard Series


RAS-(8-12)FSXNSE

RAS-(14-18)FSXNSE

RAS-(20-24)FSXNSE

23
Technical Specifications

Set Free Sigma High Efficency Series


RAS-(5-6)FSXNPE

RAS-(8-14)FSXNPE

RAS-(16-18)FSXNPE

24
Sustainability

SUSTAINABILITY

FOCUS ON COMFORT AND THE ENVIRONMENT


Significant Reductions to CO2 Estimation of CO2 emissions reduction (10HP 28.0 kW unit)

The improvement of the efficiency


of the systems allows a significant
reduction of CO2 emissions and 15 year old circa 5,188 kg/yr
models
therefore of the environmental impact.

current models circa 2,523 kg/yr

Reduction of around
2,665
kg/yr
NOTE:
The calculation of CO 2 emissions is based on the JIS B 8616: 2015 Standards (Tokyo office).

Significant reduction to energy Estimated reduction in seasonal energy consumption (10HP 28.0 kW unit)
consumption
The increase in performances and efficiency 9,331 kWh/yr
15 year old
together with the reduction of the absorp- models
tions due to today’s increasingly performing
fans and to the improvement of the com-
pression capacity, have contributed to a sub-
stantial decrease in consumption. current models 4,537 kWh/yr

Reduction of around
51%

0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000
kWh/yr

25
SYSTEM FREE

INDOOR UNITS

Unique to Hitachi: our range of


indoor units are compatible with
Utopia Split & Multi systems,
as well as our entire VRF range.
This provides the flexibility to
meet any climate requirements
using the same control
interfaces for complete
integration and ease
of installation.

26
Wall Mounted Indoor Units

SYSTEM FREE

RPK 0.6-1FSN3M RPK 1.5FSN3M RPK 2-4FSN3M


Integrated infra-red receiver and automatic restart
Easily accessible filters PC ARFPE

Sizes 0.4 to 1.5HP available with external EEV option. Multi-function graphical remote control
SY

WALL MOUNTED Unit RPK 0.4FSN3M RPK 0.6FSN(H)3M RPK 0.8FSN(H)3M RPK 1.0FSN(H)3M RPK 1.5 (1.3)FSN(H)3M RPK 1.5FSN(H)3M
Nominal Cooling Capacity (Set Free System)(1) Kw 1.1 1.7 2.2 2.8 3.8 4.0
Nominal Heating Capacity (Set Free System)(2) Kw 1.3 1.9 2.5 3.2 4.2 4.8
UK Cooling Capacity total/sensible (Set Free system)(3) Kw 1.0 / 0.9 1.5 / 1.4 2.1 / 1.9 2.6 / 2.0 3.4 / 2.8 3.9 / 3.2
Noise Level (sound pressure) (L / M / H / H2)(4) (5) dB(A) 29 / 30 / 31 / 32 29 / 31 / 32 / 35 30 / 32 / 35 / 39 30 / 32 / 35 / 39 33 / 36 / 40 / 46 33 / 36 / 40 / 46
Noise level (sound power) dB(A) 49 49 53 53 58 58

Air flow cooling mode (L / M / H / H2)(5) 360 / 402 / 438


m3/h 360 / 420 / 450 / 480 390 / 420 / 480 / 600 390 / 420 / 480 / 600 450 / 540 / 660 / 840 450 / 540 / 660 / 840
/ 450
Dimensions (H x W x D) mm 300 x 790 x 230 300 x 790 x 230 300 x 790 x 230 300 x 790 x 230 300 x 900 x 230 300 x 900 x 230
Weight kg 10 10 10 10 11 11
Included Condensate Pump No
Drain Diameter (ext) φ20mm φ20mm φ20mm φ20mm φ20mm φ20mm
Inch 1/4 / 1/2
Piping Diameter (Liquid / Gas)
mm 6.35 / 12.70
Fan motor output 38 40
Power supply 230V / 1Ph / 50Hz
Recommended fuse size A 5

Unit RPK 2.0(1.8)FSN3M RPK 2.0FSN3M RPK 2.5(2.3)FSN3M RPK 2.5FSN3M RPK 3.0FSN3M RPK 4.0FSN3M
Nominal Cooling Capacity (Set Free System)(1) Kw 5.2 5.6 6.7 7.1 8.0 11.2
Nominal Heating Capacity (Set Free System)(2) Kw 5.6 6.3 7.5 8.5 9.0 12.5
UK Cooling Capacity total/sensible (Set Free system)(3) Kw 4.5 / 3.2 5.2 / 3.7 6.2 / 4.6 6.4 / 4.7 7.5 / 5.7 10.5 / 7.5
Noise Level (sound pressure) (L / M / H / H2)(4) (5) dB(A) 33 / 38 / 40 / 42 33 / 38 / 40 / 42 36 / 40 / 43 / 49 36 / 40 / 43 / 49 36 / 40 / 43 / 49 41 / 46 / 49 / 51
Noise level (sound power) dB(A) 57 57 57 59 59 64
Air flow cooling mode (L / M / H / H2)(5) m3/h 600/780/840/900 600/780/840/900 720/840/1020/1140 720/840/1020/1140 450/540/660/840 900/1020/1140/1320
Dimensions (H x W x D) mm 333 x 1150 x 245 333 x 1150 x 245 333 x 1150 x 245 333 x 1150 x 245 333 x 1150 x 245 333 x 1150 x 245
Weight kg 17 17 18 18 18 18
Included Condensate Pump No
Drain Diameter (ext) φ20mm φ20mm φ20mm φ20mm φ20mm φ20mm
Inch 1/4 / 5/8 1/4 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8
Piping Diameter (Liquid / Gas)
mm 6.35 / 15.88 6.35 / 15.88 9.53 / 15.88 9.53 / 15.88 9.53 / 15.88 9.53 / 15.88
Fan motor output 40
Power supply 230V / 1Ph / 50Hz
Recommended fuse size A 5

NOTES: (2) Heating: Internal ambient 20°C - Ambient 7°C db (6°C wb) 1.0m from the air inlet (measured in anechoic room)
(3) UK Cooling: Internal Temperature 23°C db (16°C wb) - Ambient 30°C (5) 4 step fan speed only available with PC-ARFPE remote controller
(1) Cooling: Internal ambient 27°C db (19°C wb) - Ambient 35°C
(4) Sound pressure level measured at 1.0 metres below the unit and

27
Floor Mounted Indoor Units

SYSTEM FREE
FLOOR MOUNTED

RPF-1~2.5FSN2E RPFI-1~2.5FSN2E

Horizontal or vertical flow (uncased model)


Many switches available (Start relay, Fault relay, thermostat control, remote “on/off”)
PC ARFPE

Multi-function graphical remote control

FLOOR MOUNTED
RPF RPF RPF RPF RPF RPF RPF RPF
(CASED) Unit 1.0 (0.8)FSN2E 1.0FSN2E 1.5 (1.3)FSN2E 1.5FSN2E 2.0(1.8)FSN2E 2.0FSN2E 2.5(2.3)FSN2E 2.5FSN2E
Nominal Cooling Capacity (Set Free System)(1) Kw 2.2 2.8 3.8 4.0 5.2 5.6 6.7 7.1
Nominal Heating Capacity (Set Free System)(2) Kw 2.5 3.2 4.2 4.8 5.6 6.3 7.5 8.5
UK Cooling Capacity total/sensible (Set Free
system)(3) Kw 2.1 / 1.5 2.6 / 1.9 3.4 / 2.5 3.9 / 2.8 4.5 / 3.3 5.2 / 3.8 6.2 / 4.5 6.4 / 4.7

Noise Level (sound pressure) (L / M / H / H2)(4) (5) dB(A) 29 / 32 / 35 29 / 32 / 35 31 / 35 / 38 31 / 35 / 38 32 / 36 / 39 32 / 36 / 39 34 /38 / 42 34 / 38 / 42


Noise level (sound power) dB(A) 57 60
Air flow cooling mode (L / M / H / H2)(5) m3/h 360/420/510 360/420/510 540/600/720 540/600/720 660/840/960
Dimensions (H x W x D) mm 630x1045x220 630x1045x220 630x1170x220 630x1170x220 630x1420x220
Weight kg 25 25 28 28 33 33 34 34
Included Condensate Pump no
Drain Diameter (ext) φ18.5mm
Inch 1/4 / 1/2 1/4 / 5/8 3/8 / 5/8
Piping Diameter (Liquid / Gas)
mm 6.35 / 12.70 6.35 / 15.88 9.53 / 15.88
Fan motor output 20 28 45
Power supply 230V / 1Ph / 50Hz
Recommended fuse size A 5

FLOOR MOUNTED
RPFI RPFI RPFI RPFI RPFI RPFI RPFI RPFI
(UNCASED) Unit 1.0 (0.8)FSN2E 1.0FSN2E 1.5 (1.3)FSN2E 1.5FSN2E 2.0(1.8)FSN2E 2.0FSN2E 2.5(2.3)FSN2E 2.5FSN2E
Nominal Cooling Capacity (Set Free System)(1) Kw 2.2 2.8 3.8 4.0 5.2 5.6 6.7 7.1
Nominal Heating Capacity (Set Free System)(2) Kw 2.5 3.2 4.2 4.8 5.6 6.3 7.5 8.5
UK Cooling Capacity total/sensible (Set Free
system)(3) Kw 2.1 / 1.5 2.6 / 1.9 3.4 / 2.5 3.9 / 2.8 4.5 / 3.3 5.2 / 3.8 6.2 / 4.5 6.4 / 4.7

Noise Level (sound pressure) (L / M / H / H2)


(4) (5) dB(A) 29 / 32 / 35 29 / 32 / 35 31 / 35 / 38 31 / 35 / 38 32 / 36 / 39 32 / 36 / 39 34 / 38 / 42 34 / 38 / 42

Noise level (sound power) dB(A) 57 60


Air flow cooling mode (L / M / H / H2)(5) m3/h 360/420/510 360/420/510 540/600/720 540/600/720 660/840/960
Dimensions (H x W x D) mm 620x840x220 620x840x220 620x973x220 620x973x220 620x122x220
Weight kg 19 19 23 23 27 27 28 28
Included Condensate Pump no
Drain Diameter (ext) φ18.5mm
Inch 1/4 / 1/2 1/4 / 5/8 3/8 / 5/8
Piping Diameter (Liquid / Gas)
mm 6.35 / 12.70 6.35 / 15.88 9.53 / 15.88
Fan motor output 20 28 45
Power supply 230V / 1Ph / 50Hz
Recommended fuse size A 5

28
2-Way Cassette Indoor Units

SYSTEM FREE
2-WAY CASSETTE

Low installation height (298mm)


Integrated lift pump

PC ARFPE
RCD 1~5FSN2E
Multi-function graphical remote control

WALL MOUNTED Unit RCD 0.8FSN3 RCD 1.0FSN3 RCD 1.5(1.3)FSN3 RCD 1.5FSN3 RCD 2.0(1.8)FSN3 RCD 2.0FSN3
Nominal Cooling Capacity (Set Free System)(1) Kw 2.2 2.8 3.8 4.0 5.2 5.6
Nominal Heating Capacity (Set Free System)(2) Kw 2.5 3.2 4.2 4.8 5.6 6.3
UK Cooling Capacity total/sensible (Set Free system)(3) Kw 1.9 / 1.8 2.5 / 2.1 3.4 / 2.5 3.5 / 2.8 4.5 / 3.4 4.9 / 3.9
Noise Level (sound pressure) (L / M / H / H2)(4) (5) dB(A) 27 / 28 / 29 / 30 27 / 28 / 29 / 31 30/31/34/37 30/31/34/37 30/33/36/39 30/33/36/39
Noise level (sound power) dB(A) 44 46 49 49 51 51
Air flow cooling mode (L / M / H / H2)(5) m3/h 390/450/540/600 390/450/570/600 600/690/780/900 600/690/780/900 630/750/870/990 630/750/870/990
Dimensions (H x W x D) mm 345x860x630
Weight kg 23 25
Included Condensate Pump yes
Condensate Pump Lift 850 mm from the bottom edge of the unit
Drain Diameter (ext) φ32mm
Inch 1/4 / 1/2
Piping Diameter (Liquid / Gas)
mm 6.35 / 12.70
Fan motor output 57
Power supply 230V / 1Ph / 50Hz
Recommended fuse size A 5
Standard Panel Reference P-AP90DNA
Panel dimensions (H x W x D) mm 30 x 1100 x 710
Panel weight kg 7.5

Unit RCD 2.5(2.3)FSN3 RCD 2.5FSN3 RCD 3.0FSN3 RCD 4.0FSN3 RCD 5.0FSN3 RCD 6.0FSN3
Nominal Cooling Capacity (Set Free System)(1) Kw 6.7 7.1 8.0 11.2 14.0 16.0
Nominal Heating Capacity (Set Free System)(2) Kw 7.5 8.5 9.0 12.5 16.0 18.0
UK Cooling Capacity total/sensible (Set Free system)(3) Kw 6.2 / 4.6 6.2 / 4.7 7.0 / 5.6 9.8 / 7.7 12.3 / 8.8 14.0 / 9.9
Noise Level (sound pressure) (L / M / H / H2)(4) (5) dB(A) 33/36/39/42 33/36/39/42 33 /38/42/45 34/37/40/43 35/41/ 44 /47 39/42/45/48
Noise level (sound power) dB(A) 52 52 55 55 55 59

Air flow cooling mode (L / M / H / H2)(5) 1440 / 1710 / 1950


m3/h 750/870/990/1110 750/870/990/1110 750 / 960 / 1110 / 1260 1200 / 1380 / 1590/1800 1260 / 1620 / 1860 / 2100 / 2220
Dimensions (H x W x D) mm 345x860x630 345x1420x630
Weight kg 25 39
Included Condensate Pump yes
Condensate Pump Lift 850 mm from the bottom edge of the unit
Drain Diameter (ext) φ32mm
Inch 3/8 / 5/8
Piping Diameter (Liquid / Gas)
mm 9.53 / 15.88
Fan motor output 57 57 x2
Power supply 230V / 1Ph / 50Hz
Recommended fuse size A 5
Standard Panel Reference P-AP90DNA P-AP160DNA
Panel dimensions (H x W x D) mm 30 x 1100 x 710 30 x 1660 x 710
Panel weight kg 7.5 10.5

29
Mini 4-Way Cassette Indoor Units

SYSTEM FREE
MINI 4-WAY CASSETTE

Fits neatly in a 600 × 600 mm ceiling tile PC ARFPE


RCIM 1~2FSN4
Wiring box inside and integrated lift pump Multi-function graphical remote control

Motorised air-flow shutters, 2, 3 or 4 channels with shutter KIT PI 23LS5 kit

MINI 4-WAY CASSETTE Unit RCIM 0.4FSN4 RCIM 0.6FSN4 RPK 0.8FSN(H)3M RCIM 1.0FSN4 RCIM 1.5(1.3)FSN4
Nominal Cooling Capacity (Set Free System)(1) Kw 1.1 1.7 2.2 2.8 3.8
Nominal Heating Capacity (Set Free System)(2) Kw 1.3 1.9 2.5 3.2 4.2
UK Cooling Capacity total/sensible (Set Free system)(3) Kw 1.0 / 0.9 1.5 / 1.4 1.9 / 1.7 2.5 / 2.0 3.3 / 2.4
Noise Level (sound pressure) (L / M / H / H2)(4) dB(A) 28 / 32 / 34 24 / 28 / 30 / 34 24 / 29 / 33 / 36 24 / 30 / 34 / 38 27 / 33 / 37 / 41
Noise level (sound power) dB(A) 43 47 50 51 54
Air flow cooling mode (L / M / H / H2)(5) m3/h 360 / 414 / 468 / 510 360 / 480 / 570 / 660 360 / 480 / 570 / 660 360 / 510 / 600 / 720 420 / 570 / 660 / 780
Dimensions (H x W x D) mm 285x570x570 285x570x570 285x570x570 285x570x570 285x570x570
Weight kg 16
Included Condensate Pump yes
Condensate Pump Lift 650 mm from the bottom edge of the unit
Drain Diameter (ext) φ32mm
Inch 1/4 / 1/2
Piping Diameter (Liquid / Gas)
mm 6.35 / 12.70
Fan motor output 70
Power supply 230V / 1Ph / 50Hz
Recommended fuse size A 5

Unit RCIM 1.5FSN4 RCIM 2.0(1.8)FSN4 RCIM 2.0FSN5 RCIM 2.5(2.3)FSN5 RCIM 2.5FSN5
Nominal Cooling Capacity (Set Free System)(1) Kw 4 5.2 5.6 6.7 7.1
Nominal Heating Capacity (Set Free System)(2) Kw 4.8 5.6 6.3 7.5 8.5
UK Cooling Capacity total/sensible (Set Free system)(3) Kw 3.5 / 2.6 4.5 / 3.2 4.9 / 3.6 5.9 / 4.0 6.2 / 4.2
Noise Level (sound pressure) (L / M / H / H2)(4) dB(A) 27/33/37/41 31/35/39/45 31/35/39/45 35/39/43/47 35/39/43/47
Noise level (sound power) dB(A) 54 56 56 60 60
Air flow cooling mode (L / M / H / H2)(5) m3/h 420/570/660/780 480/600/720/900 480/600/720/900 600/720/840/960 600/720/840/960
Dimensions (H x W x D) mm 285x570x570 285x570x570 285x570x570 285x570x570 285x570x570
Weight kg 16 17
Included Condensate Pump yes
Condensate Pump Lift 650 mm from the bottom edge of the unit
Drain Diameter (ext) φ32mm
Inch 1/4 / 1/2 3/8 / 5/8
Piping Diameter (Liquid / Gas)
mm 6.35 / 12.70 9.52 / 15.88
Fan motor output 70 71
Power supply 230V / 1Ph / 50Hz
Recommended fuse size A 5

Standard Panel Reference P-AP56NAM


Panel dimensions (H x W x D) mm 30 x 620 x 620
Panel weight kg 3

30
4-Way Cassette Indoor Units

SYSTEM FREE
4-WAY CASSETTE HI-EFFICIENCY

RCI 1~6FSN4

Low noise level 27 dB(A)


4 fan speeds
After inactivity in room temperature set point can be adjusted by 1 or 2°C or thermo-off via mode setting in PC-ARFPE PC ARFPE

Exceptional performance Multi-function graphical remote control

After inactivity in room Air flow is reduced by one fan speed. Louvres move to horizontal position

4-WAY CASSETTE Unit RCI 1.0FSN4 RCI 1.5(1.3)FSN4 RCI 1.5FSN4 RCI 2.0(1.8)FSN4 RCI 2.0FSN4 RCI 2.5(2.3)FSN4
Nominal Cooling Capacity (Set Free System)(1) Kw 2.8 3.8 4.0 5.2 5.6 6.7
Nominal Heating Capacity (Set Free System)(2) Kw 3.2 4.2 4.8 5.6 6.3 7.5
UK Cooling Capacity total/sensible (Set Free system)(3) Kw 2.6 / 2.1 3.4 / 2.6 3.9 / 3.0 4.5 / 3.5 5.2 / 4.1 6.2 /4.5
Noise Level (sound pressure) (L / M / H / H2)(4) (5) dB(A) 27 / 28 / 30 / 33 27 / 30 / 31 / 35 27 / 30 / 31 / 35 27 / 30 / 32 / 37 27 / 30 / 32 / 37 28 / 32 / 36 / 42
Noise level (sound power) dB(A) 52 53 53 55 55 56
Air flow cooling mode (L / M / H / H2)(5) m3/h 540 / 660 / 780 / 900 660 / 840 / 1020 / 1260 660 / 840 / 1020 / 1260 660 / 840 / 1020 / 1320 660 / 840 / 1020 / 1320 840 / 1080 / 1380 / 1620
Dimensions (H x W x D) mm 248 x 840 x 840
Weight kg 20 21
Included Condensate Pump yes
Condensate Pump Lift 850 mm from the bottom edge of the unit
Drain Diameter (ext) φ32mm
Inch 1/4 / 1/2 3/8 / 5/8
Piping Diameter (Liquid / Gas)
mm 6.35 / 12.70 9.52 / 15.88
Fan motor output 57
Power supply 230V / 1Ph / 50Hz
Recommended fuse size A 5

Unit RCI 2.5FSN4 RCI 3.0FSN4 RCI 4.0FSN4 RCI 5.0FSN4 RCI 5.0FSN4
Nominal Cooling Capacity (Set Free System)(1) Kw 7.1 8.0 11.2 14.0 16.0
Nominal Heating Capacity (Set Free System)(2) Kw 8.5 9.0 12.5 16.0 18.0
UK Cooling Capacity total/sensible (Set Free system)(3) Kw 6.4 / 4.7 7.5 / 5.9 10.5 / 8.2 12.7 / 9.4 14.8 / 10.8
Noise Level (sound pressure) (L / M / H / H2)(4) (5) dB(A) 28 / 32 / 36 / 42 28 / 32 / 36 / 42 33 / 39 / 43 / 48 35 / 40 / 45 / 48 37 / 41 / 46 / 48
Noise level (sound power) dB(A) 56 57 64 64 65
Air flow cooling mode (L / M / H / H2)(5) m3/h 840/1080/1380/1620 840 / 1080 / 1380 / 1620 1200 / 1440 / 1860 / 2220 1260 / 1560 / 1980 / 2220 1320 / 1680 / 2100 / 2220
Dimensions (H x W x D) mm 248 x 840 x 840
Weight kg 22 26
Included Condensate Pump yes
Condensate Pump Lift 850 mm from the bottom edge of the unit
Drain Diameter (ext) φ32mm
Inch 3/8 / 5/8
Piping Diameter (Liquid / Gas)
mm 9.52 / 15.88
Fan motor output 57
Power supply 230V / 1Ph / 50Hz
Recommended fuse size A 5

Standard Panel Reference P- N23NA2


Panel dimensions (H x W x D) mm 40 x 950 x 950
Panel weight kg 6.5

31
Ceiling Ducted Slim Indoor Units

SYSTEM FREE
DUCTED IN THE CEILING SLIM WIDTH

RPIM 0.6~1.5FSN4E
(Slim width)

Very low noise


DC Inverter fan motors deliver up to 70% reduction in energy consumption compared to previous model
Designed for small spaces with maintenance access through the underside of the unit PC ARFPE

Easy maintenance, very compact and low noise – ideal for hotels Multi-function graphical remote control

Available with (or without) built-in condensate pump.

RPIM 0.8FSN4E- RPIM 1.0FSN4E- RPIM 1.5(1.3)


DUCTED IN THE CEILING (SLIM WIDTH) Unit RPIM 0.6FSN4E-(DU) (DU) (DU) FSN4E-(DU) RPIM 1.5FSN4E-(DU)
Nominal Cooling Capacity (Set Free System)(1) Kw 1.7 2.2 2.8 3.8 4.0
Nominal Heating Capacity (Set Free System)(2) Kw 1.9 2.5 3.2 4.2 4.8
UK Cooling Capacity total/sensible (Set Free system)(3) Kw 1.5 / 1.2 2.1 / 1.7 2.6 / 2.1 3.4 / 2.4 3.9 / 2.8
Noise Level (sound pressure) (L / M / H )(4)(SP-00) dB(A) 25 / 28 / 28 27 / 29 / 29 27 / 29 / 29 28 / 30 / 30 28 / 30 / 30
Noise level (sound power) (SP-00) dB(A) 49 50 50 51 51
Air flow cooling mode (L / M / H )(5) (SP-00) m3/h 330/372/420 330 / 408 / 480 330 / 408 / 480 480 / 540 / 600 480 / 540 / 600
Static Pressure Nom. (min ~ max) Pa 20 (0~35) 32 (0~50) 27 (0 - 58)
Dimensions (H x W x D) mm 275x702x600
Weight kg 26
Included Condensate Pump (DU Model Only) yes
Condensate Pump Lift 850 mm from the bottom edge of the unit
Drain Diameter (ext) φ25mm
Inch 1/4 / 1/2
Piping Diameter (Liquid / Gas)
mm 6.35 / 12.70
Fan motor output 60
Power supply 230V / 1Ph / 50Hz
Recommended fuse size A 5

NOTES: (2) Heating: Internal ambient 20°C - Ambient 7°C db (6°C wb) 1.0m from the air inlet (measured in anechoic room)
(3) UK Cooling: Internal Temperature 23°C db (16°C wb) - Ambient 30°C (5) 4 step fan speed only available with PC-ARFPE remote controller
(1) Cooling: Internal ambient 27°C db (19°C wb) - Ambient 35°C
(4) Sound pressure level measured at 1.0 metres below the unit and

32
Ceiling Ducted Low Indoor Units

SYSTEM FREE
DUCTED IN THE CEILING LOW HEIGHT

RPI 0.6~1.5FSN5E
(Low height)

DC Inverter fan motors deliver up to 70% reduction in energy consumption compared to previous model
Very low noise PC ARFPE

Designed for small spaces with maintenance access through the underside of the unit Multi-function graphical remote control

Easy maintenance, very compact and low noise – ideal for hotels
Available with (or without) built-in condensate pump.

DUCTED IN THE CEILING


(LOW HEIGHT) Unit RPI 0.4FSN5E RPI 0.6FSN5E RPI 0.8FSN5E) RPI 1.0FSN5E RPI 1.5(1.3)FSN5E RPI 1.5FSN5E
Nominal Cooling Capacity (Set Free System)(1) Kw 1.1 1.7 2.2 2.8 3.8 4.0
Nominal Heating Capacity (Set Free System)(2) Kw 1.3 1.9 2.5 3.2 4.2 4.8
UK Cooling Capacity total/sensible (Set Free system)(3) Kw 1.0 / 0.8 1.5 / 1.2 2.1 / 1.7 2.6 / 2.1 3.4 / 2.4 3.9 / 2.8
Noise Level (sound pressure) (L / M / H )(4)(SP-00) dB(A) tbc 27 / 30 / 32 29 / 31 / 33 29 / 31 / 33 29 / 31 / 34 29 / 31 / 34
Noise level (sound power) (SP-00) dB(A) tbc 50 52 52 53 53
Air flow cooling mode (L / M / H )(5) (SP-00) m3/h 336 / 354 / 384 330 / 372 / 420 378 / 432 / 480 378 / 432 / 480 480 / 540 / 600 480 / 540 / 600
Static Pressure Nom. (min ~ max) Pa 20 (0~35) 32 (0~50) 27 (0 - 58)
Dimensions (H x W x D) mm 197 x 700 x 600 197 x 1084 x 600
Weight kg 18 29
Included Condensate Pump (DU Model Only) yes
Condensate Pump Lift 850 mm from the bottom edge of the unit
Drain Diameter (ext) φ32mm
Inch 1/4 / 1/2
Piping Diameter (Liquid / Gas)
mm 6.35 / 12.70
Fan motor output 60
Power supply 230V / 1Ph / 50Hz
Recommended fuse size A 5

NOTES: (2) Heating: Internal ambient 20°C - Ambient 7°C db (6°C wb) 1.0m from the air inlet (measured in anechoic room)
(3) UK Cooling: Internal Temperature 23°C db (16°C wb) - Ambient 30°C (5) 4 step fan speed only available with PC-ARFPE remote controller
(1) Cooling: Internal ambient 27°C db (19°C wb) - Ambient 35°C
(4) Sound pressure level measured at 1.0 metres below the unit and

33
Ceiling Ducted Indoor Units

SYSTEM FREE
DUCTED IN THE CEILING STANDARD

RPI 2~6FSN5E
(Standard)

Adjustable static pressure depending on installation requirements


Static pressure adjustment via remote controller PC ARFPE

Built-in drain pump (excludes RPI-FSN3E models) Multi-function graphical remote control

DUCTED IN THE CEILING RPI


2.0(1.8) RPI RPI 2.5(2.3) RPI
(STANDARD) Unit FSN5E 2.0FSN5E FSN5E 2.5FSN5E RPI 3.0FSN5E RPI 4.0FSN5E RPI 5.0FSN5E RPI 6.0FSN5E
Nominal Cooling Capacity (Set Free System)(1) Kw 5.2 5.6 6.7 7.1 8.0 11.2 14.0 16.0
Nominal Heating Capacity (Set Free System)(2) Kw 5.6 6.3 7.5 8.5 9.0 12.5 16.0 18.0
UK Cooling Capacity total/sensible (Set Free system)
(3) Kw 4.5 / 3.4 5.2 / 4.0 6.2 / 4.7 6.4 / 4.9 7.5 / 5.6 10.5 / 7.7 12.7 / 9.1 14.8 / 10.7

Noise Level (sound pressure) (L / M / H )(4)(SP-00) dB(A) 27 / 29 / 29 27 / 29 / 29 28 / 30 /30 28 / 30 / 30 29 / 31 / 31 32 / 35 / 37 33 / 35 / 38 33 / 36 / 39


Noise level (sound power) (SP-00) dB(A) 55 56 57 62 65 66
Air flow cooling mode (L / M / H )(5) (SP-00) m3/h 600/750/960 600/750/960 780/960/1140 780/960/1140 960 / 1140 / 1320 1500 / 1680 / 1800 1740 / 1920 / 2100 1800 / 1980 / 2160
Static Pressure Nom. (min ~ max) Pa 30 (0 - 120) 30 (0 - 125) 45 (0 - 120) 50 (0 - 140)
Dimensions (H x W x D) mm 275x1084x600 275x1474x600
Weight kg 35 36 48
Included Condensate Pump (DU Model Only) yes
Condensate Pump Lift 850 mm from the bottom edge of the unit
Drain Diameter (ext) φ32mm
Inch 1/4 / 5/8 3/8 / 5/8
Piping Diameter (Liquid / Gas)
mm 6.35 / 15.88 9.53 / 15.88
Fan motor output 60 150 250
Power supply 230V / 1Ph / 50Hz
Recommended fuse size A 5
NOTES: (2) Heating: Internal ambient 20°C - Ambient 7°C db (6°C wb) 1.0m from the air inlet (measured in anechoic room)
(3) UK Cooling: Internal Temperature 23°C db (16°C wb) - Ambient 30°C (5) 4 step fan speed only available with PC-ARFPE remote controller
(1) Cooling: Internal ambient 27°C db (19°C wb) - Ambient 35°C
(4) Sound pressure level measured at 1.0 metres below the unit and

34
Ceiling Ducted Large Indoor Units

SYSTEM FREE
DUCTED IN THE CEILING LARGE CAPACITY

Adjustable static pressure depending on installation requirements


Static pressure adjustment via remote controller
Built-in drain pump(excludes RPI-FSN3E models)

PC ARFPE
RPI 8~10FSN3E
Multi-function graphical remote control
(Large capacity)

DUCTED IN THE CEILING


(LARGE CAPACITY) Unit RPI 8.0FSN3E RPI 10.0FSN3E RPI 16.0FSN3PE RPI 20.0FSN3PE
Nominal Cooling Capacity (Set Free System)(1) Kw 22.4 28.0 45.0 56.0
Nominal Heating Capacity (Set Free System)(2) Kw 25.0 31.0 50.0 63.0
UK Cooling Capacity total/sensible (Set Free system)(3) Kw 18.4 / 14.21 22.9 / 18.1 36.8 / 28.4 45.8 / 36.2
Noise Level (sound pressure) (L / M / H )(4)(SP-00) dB(A) 51/54/54 52/55/55 53/56 54/57
Noise level (sound power) (SP-00) dB(A) 77 78 79 80
Air flow cooling mode (L / M / H )(5) (SP-00) m3/h 3600/3960/3960 4110/4500/4500 7200/7920 8220/9000
Static Pressure Nom. (min ~ max) Pa 180/220/220
Dimensions (H x W x D) mm 432x 1592x600 846 x 1592 x 600
Weight kg 85 87 171 175
Included Condensate Pump (DU Model Only) Yes
Condensate Pump Lift -
Drain Diameter (ext) φ25mm 2 x φ25mm
Inch 3/8 / 3/4 3/8 / 7/8 2 x 3/8 / 3/4 2 x 3/8 / 7/8
Piping Diameter (Liquid / Gas)
mm 9.53 / 19.05 9.53 / 22.2 2 x 9.53 / 19.05 2 x 9.53 / 22.2
Fan motor output 1065 2 x 1065
Power supply 230V / 1Ph / 50Hz
Recommended fuse size A 10 25

NOTES: (2) Heating: Internal ambient 20°C - Ambient 7°C db (6°C wb) 1.0m from the air inlet (measured in anechoic room)
(3) UK Cooling: Internal Temperature 23°C db (16°C wb) - Ambient 30°C (5) 4 step fan speed only available with PC-ARFPE remote controller
(1) Cooling: Internal ambient 27°C db (19°C wb) - Ambient 35°C
(4) Sound pressure level measured at 1.0 metres below the unit and

35
Ceiling Suspended Indoor Units

SYSTEM FREE
CEILING SUSPENDED HIGH EFFICIENCY

RPC FSN3

New Improved Impeller Design Motion Sensor


PC ARFPE
New Improved Heat Exchanger Four Fan Speeds Available (With PC-ARFPE)
Multi-function graphical remote control
New Louvre Design with Larger Discharge New Optional Infra-Red Receiver Kit (SOR-NEP)
Air Outlet

CEILING SUSPENDED
(HIGH EFFICIENCY) Unit RPC 1.5(1.3)FSN3 RPC 1.5FSN3E RPC 2.0(1.8)FSN3 RPC 2.0FSN3 RPC 2.5(2.3)FSN3
Nominal Cooling Capacity (Set Free System)(1) Kw 3.8 4.0 5.2 5.6 6.7
Nominal Heating Capacity (Set Free System)(2) Kw 4.2 4.8 5.6 6.3 7.5
UK Cooling Capacity total/sensible (Set Free system)
(3) Kw 3.4 / 2.4 3.9 / 2.8 4.5 / 3.2 5.2 / 3.7 6.2 / 4.5

Noise Level (sound pressure) (L / M / H/H2 )(4)(5) dB(A) 28/31/35/37 28 /31/35/37 28/31/35/38 28/31/35/38 28/31/35/38
Noise level (sound power) dB(A) 53 54
Air flow cooling mode (L / M / H /H2)(4)(5) m3/h 540 / 660 / 780 / 900 690 / 840 / 990 / 1140
Dimensions (H x W x D) mm 235 x 960 x 690 235 x 1270 x 690
Weight kg 26 27 35
Included Condensate Pump (DU Model Only) Opt
Drain Diameter (ext) φ25mm
Inch 1/4 / 1/2 1/4 / 5/8 3/8 / 5/8
Piping Diameter (Liquid / Gas)
mm 6.35 / 15.88 6.35 / 15.88 9.53 / 15.88
Fan motor output 50 80
Power supply 230V / 1Ph / 50Hz
Recommended fuse size A 5

NOTES: (2) Heating: Internal ambient 20°C - Ambient 7°C db (6°C wb) 1.0m from the air inlet (measured in anechoic room)
(3) UK Cooling: Internal Temperature 23°C db (16°C wb) - Ambient 30°C (5) 4 step fan speed only available with PC-ARFPE remote controller
(1) Cooling: Internal ambient 27°C db (19°C wb) - Ambient 35°C
(4) Sound pressure level measured at 1.0 metres below the unit and

36
Hydro Free Units

SYSTEM FREE
HYDRO FREE

OUTDOOR WATER MODULE SYSTEM INDOOR

CH box (optional)
Indoor unit

Water module

Set free
outdoor unit

CH box (optional)
(or low temperature radiator)

High & Low temperature applications connect High temperature ideal for refurbishment Low temperature reversible so ideal solution
to both 3 & 2-pipe VRF where boiler systems can be replaced and for fan coils
existing heat emitters kept
Permanent hot water when connected to heat
recovery, timed when connected to heat pump Smart cascade system using a separate R134A
compressor produces hot water up to 80oC with
Low temperature ideal for providing low cost
the highest seasonal efficiency on the market
sanitary hot water for offices & hotel applications

LOW TEMPERATURE HIGH TEMPERATURE

HYDRO FREE
Unit RWLT-3.0VNE RWLT-5.0VNE RWLT-10.0VNE RWHT-5.0VNFE
Nominal capacity (7°C ext / 35°C water)(heating) Kw 9 16 31 16
Nominal capacity (-7°C ext / 35°C water)(heating) Kw 5.5 11.5 20.3 13.9
Nominal capacity (-7°C ext / 45°C water) Kw 5.2 11.1 17.9 12.4
Net Weight kg 35 50 62 129
Height (with connections) mm 712 (782) 890 (960) 890 (960) 751(802)
Dimensions Width mm 450 520 670 600
Depth mm 275 360 360 623
Sound Power dB(A) 37 39 47 57
Flow Rate (min - nom - max) m3/h 0.8 - 1.29 - 3.3 1.3 - 2.41 - 4.0 2.3 - 4.13 - 5.5 1.3 - 1.64 - 3.2
Minimum Water Volume L 100 150 180 80
Power Supply 1~ 230V 50Hz 1~ 230V 50Hz
Maximum Power Consumption kW 0,05 0,08 0,14 6.23
Refrigeration connection type Flare nut Liq:Flarenut / Gas:Braze Flare nut
Diameter of pipes (liq - gas) Inch 3/8” - 5/8” 3/8” - 7/8” 3/8” - 5/8”
Hydraulic connection (male/male vales provided) Inch 1” 1 - 1/4” 1 - 1/4” 1-1/4” - 1-1/4”
Total connection ratio of Hydro Free 0 ~ 100% 0 ~ 100% 0 ~ 100%
Total connection ratio of IU when Hydro Free installed
50% ~ 130% 50% ~ 130% 50% ~ 130%

2 Pipe VRF 50% ~ 130% 50% ~ 130%


Total connection ratio of
Hyrdro Free & IU RAS-FSXNSE: 50% ~ 150% RAS-FSXNSE: 50% ~ 150%
3 Pipe VRF
RAS-FSXNPE: 50% ~ 180% RAS-FSXNPE: 50% ~ 180%
Max number of IU when Hydro Free is installed 32 32
Water outlet temperature range 20°C ~ 45°C 20°C ~ 45°C
Remote Control PC-ARFWE (to be mounted on site) PC-ARFWE (to be mounted on site)

37
CONTROL
SYSTEMS
& ACCESSORIES

38
Control Systems & Accessories

CONTROL
AND ACCESSORIES
SYSTEMS

Hitachi offers a wide range of control systems, from simple to complex, which enables intelligent
management of its products and systems both locally or remotely.

OUTDOOR UNITS INDOOR UNITS REMOTE


BACNET®

BUS OPERATES BY REMOTE


MODBUS® / IP IP or RTU
or
MODBUS® / RTU H-LINK II
SET-FREE FSXNSE/PE PC ARFPE

H-LINK II
KNX® H-LINK II

MINI VRF
FSNM / FS(V)N(Y)2E
PC ARH
LON® H-LINK I
H-LINK II

MICRO-VRF-IVX
KNX® / IP CS-NET WEB 4.0 Premium / Comfort

PC LH3A/
PC-AWR
MICRO VRF CENTRIFUGAL

PC-A1IO
CS-NET MANAGER
H-LINK I

(dry contact)

MODBUS® / IP HC-A64NET

CENTRAL CONTROLS
PSC-A64GT
PSC - A16RS

PSC-A32MN PSC-A64S PSC - A1T

39
Control Systems & Accessories

CONTROL
AND ACCESSORIES
SYSTEMS
CHANGEOVER BOXES

CH-AP04MSSX

CH-AP160SSX

CH-APO8MSSX

CHANGEOVER BOXES
Hitachi’s range of single and multi port
CH boxes can be installed or removed as
CH-AP280SSX
building requirements change to switch
from 2 to 3 pipe without changing the
outdoor units.
Both single and multi port boxes can be
CH-AP12MSSX
used on the same installation for maximum
flexibility and adaptability.

13% fewer connections than competitor single port CH boxes


Longer piping lengths
No drain connections required
CH-AP16MSSX
Smallest footprint, lowest height and lightest of main competitor models

Single Branch Multiple Branch


CH-AP160SSX CH-AP280SSX CH-AP04MSSX CH-AP08MSSX CH-AP12MSSX CH-AP16MSSX
Power Supply 1 ~ 230V 50Hz

Electrical Power Consumption W 5 5 11.2 22.4 33.6 44.8

Current A 0.1 0.1 0.2 0.4 0.6 0.8

Maximum Total Capacity kW 16 28 44.8 85 85 85

Number of Branches (for Indoor Unit) 1 1 4 8 12 16

Maximum Capacity per Branch kW - - 16 16 16 16

Maximum Connectable Indoor Units per Branch 7 8 6 6 6 6

Dimensions (Height x Width x Depth) 191 x 301 x 214 191 x 301 x 214 260 x 303 x 352 260 x 543 x 352 260 x 783 x 352 260 x 1023 x 352

Weight kg 6 6 14 25 36 47

40
Control Systems & Accessories

CONTROL
AND ACCESSORIES
SYSTEMS
CS-NET WEB

Hitachi’s CS-Net web is a standalone control system that allows users to fully monitor and control
their air conditioning from anywhere with web access.

FUNCTIONS  CS-NET WEB provides a means to control your system known as “Building schematic.” Very user-
friendly, all the units are displayed on a site plan of the building. CS-NET WEB has a virtual remote
control that you open by clicking on the icon of the unit or you can simply use the software
installed on your PC. The virtual remote has the same basic functionality as the
standard remote.

PRACTICAL MAINTENANCE TOOL


 From the client interface, the user can control the installation
and view any error that has occurred providing detail of the
error code and a description of the problem identified.
 Alarm Log: from the first occurrence of the fault, an alarm log
is automatically generated by the CS-NET WEB and can be
exported at any time (SYSTEM FREE range).
 Historical data: the CS-NET WEB records all operating settings
of the installation and allows the user to chart development
graphs for the changes to the settings applied during a specific
period of time in order to accurately analyse the unit operation and send specific reports prior to
maintenance works.
CALCULATED ENERGY CONSUMPTION  The mail server alerts the user by e-mail in the event that an error code is triggered on the system.
 This function is available as standard to measure and The monitoring and remote control is possible via the Modbus/IP protocol. The Centralised
record the energy consumption of all or a proportion Technical Management system (GTC) can also utilise the CS-NET WEB for comprehensive building
of the indoor units and outdoor units controlled by management.
the CS-NET WEB. This consumption distribution is
displayed as a percentage.

INSTALLATION
It is particularly suitable for administrators of buildings and can support the operation and
management of systems from the SET FREE or UTOPIA ranges. The CS-NET WEB provides
maintenance companies with all the advantages of a Centralised Technical Management system
that can be accessed remotely.
 By adding an energy meter, the
consumption is displayed in KWh.  T he CS-NET WEB operates  Standard distance: 1000 m (or 5000 m
The energy consumption can be autonomously providing both with additional booster
displayed in € or £ by providing the the system “intelligence” and
information in an hourly cost.  Ability to control 512 indoor units
the “software” interface that is
(depending on the H-LINK 2 configuration)
installed on the PC which allows
and 64 outdoor units in the SYSTEM FREE.
for remote supervision. The CS-NET
 Hotel: CS-NET WEB is compatible with the Micros hotel WEB can be connected to the site  A Modbus/IP interface is integrated as
management software Micros-Fidello, which enables and the internet either through an standard in the CS-NET WEB.
for example, the guaranteed start-up of air conditioning internal Local Area Network (LAN)
 A web server provides remote access to
in the room according to the client records. or a standard ADSL modem.
the menus.

41
** 5000 m with 4 H-LINK relays: PSC 5 HR.
Control Systems & Accessories

CONTROL
AND ACCESSORIES
SYSTEMS
CS-NET WEB
AVAILABLE FUNCTIONS ON THE SET FREE RANGE SIMPLICITY OF SETTINGS
 Control functions  Temperature set-point From the interface installed on the remote
 On / Off  Returned room temperature PC (Web), the user can choose any operating
 Operating mode  Remote temperature sensor settings for an indoor unit. These settings can
be applied to all or part of the units on site
 Temperature set-point  Temperature sensor on remote control
(SYSTEM FREE range). In order to restrict access
 Available set-point range  Filter
to the settings, it is possible to lock a number of
 Fan speed  Fan speed
the settings (temperature set-point, operating
 Direction of air flow  Direction of airflow
mode, fan speed, on/off) or limit the range of
 Local / central mode  Alarm
available settings (SYSTEM FREE range).
 Monitoring functions  Error code
 Status: on/off  Timer
 Operating mode  Energy consumption

RESTRICTED AND SECURE


ACCESS
Several levels of secure access using passwords
are available, restricting access to the operating
settings.

Recommendation: for remote access an internet connection is required.


LONG-TERM TIMER
A programmer on the timer can be used
for up to four years, enabling autonomous
operation over prolonged periods. In order
to simplify the programming, a greater
number of templates can be created and
applied to any or all of the units on site.

CS-NET WEB 4 Integrated inter- Ref: PSC-A160WEB1


net access from your smartphone

42
Control Systems & Accessories

CONTROL
AND ACCESSORIES
SYSTEMS
CS-NET MANAGER
CONTROL OF SMALL AND LARGE INSTALLATIONS
FROM 64 TO 512 INDOOR UNITS FROM ACROSS THE WEB.

The new CS-NET MANAGER is a control and supervision


interface for Hitachi air-conditioning and heating units. The
range includes two touch screens, 10 “and 17” (see below).
It is possible to add an Ethernet/H-Link
(HC- A64NET) interface to the console.
CS-NET MANAGER was designed to combine with the
CS-NET WEB and therefore form a new package on the
market; combining control functionality, maintenance,
consumption management and interface protocols. No
additional options are required.
The 320 GB storage capacity can store applications and
installation history.
Ethernet, USB and RS-485 ports allow interfacing with a
wide variety of systems. The CS-NET MANAGER can handle
from 64 to 1,280 indoor units via the internet.
CS-NET Manager 17"

ON SET FREE RANGE


Control functions
• On/Off
• Operating mode
• Temperature set-point
• Available set-point range
• Fan speed
• Direction of the airflow.
• Local/central mode

Monitoring functions CS-NET Manager 12"

• Status: start/stop
• Operating mode
• Temperature set-point
• Returned room temperature
• Filter
• Fan speed
• Airflow direction. HC-A64NET, Ethernet/H-Link interface
• Alarm connect 64 indoor units to the
module, mounted on 35mm DIN-Rail
• Error code
• Timer

43

Johnson Controls Hitachi Air Conditioning Europe SAS - UK
– –
Whitebrook Park, Lower Cookham Road, CERTIFICATION
Maidenhead
Berkshire SL6 8YA, United Kingdom
Tel.: 020 3901 0912
Email: aircon.UK@jci-hitachi.com

AVAILABLE FROM
PURE AIR DISTRIBUTION LTD.
3000 Cathedral Hill, Guildford,
JCHIT PAD SIGMA 0518

Surrey, GU2 7YL


T: 01483 246800
Specifications in this catalogue are subject to change E: sales@pureairdistribution.co.uk
without notice in order that HITACHI may bring the latest
innovations to their customers, omitting typing errors.
www.pureairdistribution.co.uk
@PureAirDist

Вам также может понравиться