Вы находитесь на странице: 1из 6

A-1 STIPULATIONS FOR PROPORTIONING

a) Grade designation(fck) 35
b) Type of cement OPC 43 grade conforming to IS 8112
c) maximum nominal size of aggregate 10
d) minimum cement content 450 kg/m^3
e) maximum water-cement ratio 0.42
f) workability mm (slump) 75
g) exposure condition Severe(for reinforced concrete)
h) method of concrete placing normal
i) degree of supervision good
j) type of aggregate crushed angular aggregate
k) maximum cement content 450 kg/m^3
l) chemical admixture type superplasticizer
A-2 TEST DATA FOR MATERIALS
a) cement used OPC 43 grade conforming to IS 8112
b) specific gravity of cement 3.15
c) chemical admixture superplasticizer conforming to IS 9103
d) specific gravity of:
1) coarse aggregate 2.74
2) fine aggregate 2.74
e) water absorption:
1) coarse aggregate 0.5 percent
2) fine aggregate 1.0 percent
f) free(surface) moisture:
1) coarse aggregate nil (absorbed moisture also nil)
2) fine aggregate nil (absorbed moisture also nil)

standard diviation 5

TARGET STRENGTH FOR MIX PROPORTIONONING(f'ck) 43.25


SELECTION WATER CEMENT RATIO 0.45
based on experience ,adoptwater cement ratio as 0.42
HENCE OK
SELECTION OF WATER CONTENT 208
FOR TAKEN WATER CONTENT SLUPMP INCREASED % 0.03
estimated water content for 75mm slump 214.24
AS SUPERPLASTICIZER IS USED,HENCE THE WATER CONTENT
CAN BE REDUCED UP 10% AND ABOVE 192.816
CALCULATION OF CEMENT CONTENT
WATER-CEMENT RATIO 0.42
CEMENT CONTENT 459.0857142857
from T-5 of IS 456,minimum cement content for severe exposure
condition HENCE NOT OK
as per code book 450
189

so adopted water content

IF NOT OK THE FINAL W/C IS 0.428

AS PER TABLE 3(0.5) 0.46


VOLUME OF CA 0.476
VOLUME OF FA 0.524
MIX CALCULATIONS
VOLUME OF CONCRETE(m3) 1
VOLUME OF CEMENT 0.143
VOLUME OF WATER 0.189
VOLUME OF CHEMICAL ADMIXTURES(SUPER PLASTICIZERS) 0.004
VOLUME OF ALL IN AGGREGATES 0.664
MASS OF CA 866
MASS OF FA 954

MIX PROPORTIONS
CEMENT 450
WATER 189
FINE AGGREGATE 954
COARSE AGGREGATE 866
WATER-CEMENT RATIO 0.42

MIX PROPORTIONS ratio

120*210*1500 volume required quantities


0.0378 for 1 beam(for two mixex)
for 1 time of mixex
for 6 beam

150*150*150 volume of required quantities


0.003375 for 1 cube
for 3 cubes

final required quantities 1beam+3cubes quantities required


25% increase required quantities 1beam+3cubes quantities required
for 1 beam+3 cubes(for two mixex)
for RETROFITTING BEAM size of increased depth

for 1 m3 volume actual quantities M35


for (50*120*1500)mm volume 0.009
10% increase
for 1 beam TOTAL QUANTITIES
for two beams TOTAL QUANTITIES
M 10 3.5
M 15 3.5
M 20 4
M 25 4
M 30 5
M 35 5
M 40 5
M 45 5
M 50 5
M 55 5

IS 456-2000,TABLE 5
MIN CEM MAX W/C MIN GRADE CONC(M)
300 0.55 20
300 0.5 25
320 0.45 30
340 0.45 35
360 0.4 40

IS 10260:2009
NOMINAL SIZE OF MAXIMUN WATER
AGGREGATE(mm) CONTENT(kg)
10 208
20 186
40 165

SLUMP RATIO ZONEII


25 0.01 10 0.46

50 0.01 20 0.62
75 0.03 40 0.71
100 0.06

Adjustments
kg/m3 0.5 0.46 required in

Change in
Volume
of coarse
aggregat
e per
Change in Water unit
condition content volume
For degree of
0.42 workability 186 0.62
For decrease in
Water-Cement
ratio is ( 0.6-
0.4 0.48 0.45)=0.15 0 0.03
X2-X1 -0.1 Total 186 0.65
Y2-Y1 0.02
X-X1 -0.08
Y-Y1 0.016
Y 0.476

0.5 0.46
0.4 0.48

0.5 0.46
0.4 0.48

0.42

WATER CEMENT FA CA
189 450 954 866
1 2.12 1.925
7.1442 17.01 36.0479724071 32.7458680645
3.5721 8.505 18.0239862036 16.3729340322
42.8652 102.06 216.2878344428 196.4752083869

WATER CEMENT FA CA
0.637875 1.51875 3.2185689649 2.92373822
1.913625 4.55625 9.6557068948 8.7712146601

9.057825 21.56625 45.7036793019 41.5170827246


11.32228 26.95781 57.1295991274 51.8963534058
` 13.47891 28.5647995637 25.9481767029
size of increased depth of beam
B D L VOLUME
0.12 0.05 1.5 0.009
water cement FA CA
189 450 954 866
1.701 4.05 8.586 7.794
0.1701 0.405 0.8586 0.7794
1.8711 4.455 9.4446 8.5734
3.7422 8.91 18.8892 17.1468