A001572
(E)
▣Specifications Panel
meter
Detecting distance 2mm ±10% 4mm ±10% 5mm ±10% 8mm ±10% 10mm ±10% 15mm ±10%
(G)
Hysteresis Max. 10% of detecting distance Display
unit
Standard detecting 18×18×1mm 25×25×1mm 30×30×1mm 45×45×1mm
12×12×1mm(Iron)
target (Iron) (Iron) (Iron) (Iron)
Setting distance 0~1.4mm 0~2.8mm 0~3.5mm 0~5.6mm 0~7mm 0~10.5mm
(H)
Power supply 24VDC Sensor
controlle
(Operation voltage) (15-30VDC)
Leakage current Max. 0.9mA
Response frequency 800Hz 400Hz 350Hz 200Hz 250Hz 100Hz (I)
Proximit
Residual voltage Max. 7V sensor
Affection by Temp. ±10% Max. for detecting distance at +20℃ within temperature range of -25 ~ +70℃
Control output 2~50mA (J)
Photo
Dielectric strength Min. 50MΩ(at 500VDC) electri c
Insulation resistance 1500VAC 50/60Hz for 1 minute sensor
I-18
PRCM Series
▣Specifications
lDC 3-wire type
PRCM18-5DN PRCM 18-8DN PRCM30-10DN PRCM30-15DN
PRCM18-5DP PRCM 18-8DP PRCM30-10DP PRCM30-15DP
PRCM 12-2DN PRCM12-4DN PRCM18-5DN2 PRCM 18-8DN2 PRCM30-10DN2 PRCM30-15DN2
PRCM 12-2DP PRCM12-4DP PRCM18-5DP2 PRCM 18-8DP2 PRCM30-10DP2 PRCM30-15DP2
Model PRCML18-5DN PRCM L18- 8DN PRCML30-10DN PRCML30-15DN
PRCM 12-2DN2 PRCM12-4DN2
PRCM 12-2DP2 PRCM12-4DP2 PRCML18-5DP PRCM L18- 8DP PRCML30-10DP PRCML30-15DP
PRCML18-5DN2 PRCM L18- 8DN2 PRCML30-10DN2 PRCML30-15DN2
PRCML18-5DP2 PRCM L18- 8DP2 PRCML30-10DP2 PRCML30-15DP2
Detecting distance 2mm ±10% 4mm ±10% 5mm ±10% 8mm ± 10% 10mm ± 10% 15mm ±10%
Hyster esis Max. 10% of detecting distance
St andard detecting 18×18×1mm 25×25× 1mm 30×30×1mm 45×45×1mm
12×12×1mm(Iron)
target (Iron) (Iron) (Iron) (Iron)
Setting dist ance 0~1.4mm 0~2.8mm 0~3.5mm 0~5.6mm 0~7mm 0~10.5mm
Power supply 12-24VDC
(Operation voltage) (10-30VDC)
Current consumption Max. 10mA
Response frequency 800Hz 400Hz 350Hz 200Hz 250Hz 100Hz
Residual voltage Ma x. 1.5V
Affection by Temp. ±10% Max. for detecting distance at +20℃ within temperature range of -25 ~ +70℃
Control output 200m A
Insulation resistance Min. 50MΩ(at 500VDC)
Dielectric str ength 1500VAC 50/60Hz for 1 minute
Vibration 1mm amplitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 2 hours
Shock 500m/s²(50G) in X, Y, Z directions for 3 times
Indicator Opera tion indicator(Red LED)
Ambient temperature -25 ~ +70℃(at non-freezing status)
St orage temperature -30 ~ +80℃(at non-freezing status)
Ambient humidity 35~95%RH
Pr otection circuit Revers e polarity protection, Surge protection c irc uit, Overload & short circuit protection
Pr otection IP67(IEC specification)
Approval
P RCM18 : Approx. 49g PRCM30 : Approx. 134g
Weight Approx. 26g
P RCML 18 : Approx. 73g PRCML : Approx. 169g
I-19
Quick Disconnection Type
▣Dimensions Unit:mm
(A)
lPRCM(T)12-2D□ lPRCM(T)12-4D□ Counter
55 .8 55.8
Operation Operation
Ø21 35.5 Ø21 35.5
indicator indicator
17 17 7 24.5
31.5
(B)
Timer
M12×1 M12×1
M12×1 4 M12×1
4
lPRCM(T)18-5D□ lPRCM(T)18-8D□
53.8
Ø29 53.8
Operation Ø29 Operation (C)
33.5 33.5 Temp.
24 indicator indicator
29 24 10 19 controlle
(F)
Tacho/
M12× 1 M30×1.5 M12×1 Speed/
5 M3 0×1 .5 5 Pulse
meter
lPRCM12-2A□ lPRCM12-4A□
72.8 72.8
Operation Operation
Ø21 52.5 Ø21 52.5 indicator
indicator (G)
17 48.5 17 7 41.5
Display
unit
(H)
lPRCM18-5A□ lPRCM18-8A□ Sensor
60.1 60.1 controlle
Ø29 39.5 Operation Ø29 39.5 Operation
24 indicator 24 indicator
35.3 10 25.3
(I)
Proximit
sensor
M18×1 M12×1 M18×1 M12×1
4 4
(K)
Pressur
sensor
M12×1 M1 2×1
5 M30×1.5 5 M30× 1.5
(M)
5-Phase
stepping
4 M18×1 M12×1 4 M18×1 motor &
M12×1
Driver &
Controlle
lPRCML30-10D□ / PRCML30-10A□ lPRCML30-15D□ / PRCML30-15A□
Ø42 85.8 Ø42 85.8
Operation 65 Operation
35 65 35
indicator 10 50 indicator
60
M12×1 M12×1
5 M30×1.5 5 M30×1.5
I-20
PRCM Series
▣Control output diagram
◎DC 3-wire type
NPN universal output type PNP universal output type
Brown NO NC NO NC
Detecting Presence Brown Detecting Presence
a +V a +V
target Nothing target Nothing
Load
10K Load Operation Load Operation
Black 2Ω Black
f (Brown-Black) Return f (Black-Blue) Return
2Ω
Output voltage H 10K Output voltage H
Load
(Black-Blue) L (Brown-Black) L
Blue Blue
d 0V Indicator ON d 0V Indicator ON
(LED) OFF (LED) OFF
Brown NO NC Brown NO NC
f Load Detecting Presence
f Load +V
Detecting Presence
target Nothing target Nothing
AC
POWER ~ Operation Operation
Load Load
Return Return
Blue
d
Indicator ON Blue Indicator ON
(LED) OFF d 0V (LED) OFF
▣Wiring diagram
◎DC 2-wire type(Standard type) ◎DC 2-wire type(IEC standard type)
Normal Open (NO) / Normal Close (NC) Normal Open (NO) / Normal Close (NC)
Brown Brown
2 1 2 1 2 1 Load 24VDC 2 1 24VDC
Brown Br own
3 4 Load 24VDC 3 4 24VDC 3 4 3 4
※Pin ①, ② are N.C(Not Connected). ※Ordering of connector pin according to IEC standard is available.
※When use DC 3-wire connection cable, black(24VDC) ※Please put " I " behind of model name for selecting proximity
and blue(0V) can be used. sensor by IEC standard. Ex)PRWT12-4DO-I
※Connector cable by IEC standard is also available.
Please put " I " behind of model name for selecting proximity
sensor by IEC standard. Ex)CID2-2-I, CLD2-5-I
I-21
Quick Disconnection Type
▣Proper usage
(A)
◎Load connections Counter
Brown Brown
Load Load
+ +
~ 24VDC ~ 100-240VAC
- _ (B)
Blue Blue Timer
<DC 2-wire type & AC 2-wire type> <DC 2-wire type> <AC 2-wire type >
(C)
When using DC or AC 2-wire type proximity sensor, the load must be connected otherwise internal Temp.
controlle
components may be damaged. And the load can be connected to either wire.
AC
If the load current is under 5mA, please make sure the
Bleeder res istor(R) ~ P OWE R residual voltage is less than the return voltage of the
(E)
load by connecting a bleeder resistor in parallel with Panel
meter
110VAC : Over 20kΩ 3W the load as shown in the diagram.
220VAC : Over 39kΩ 10W
lDC 2-wire type (F)
Please make the current on proximity sensor smaller Tacho/
Load Speed/
than the return current of load by connecting a bleeder Pulse
+
meter
Vs resistor in parallel.
Bleeder resistor(R) -
※W value of bleeder resistor should be bigger for
(G)
proper heat dissipation.
* Vs : Power supply Display
Vs unit
R ≤ (㏀) P : Bleeder resistor, number of W
Io-Ioff Io : Operating curr ent of proximity sensor
Vs² (2.5㎃ but, P RT08, PS T17 is 0.9㎃)
P> (㎽) Ioff : Return current of load
R (H)
Sensor
controlle
◎Mutual-interference & Influence by surrounding metals
When several proximity sensors are mounted close together, malfunction of sensor may be caused due to
mutual interference. Therefore, be sure to provide a minimum distance between the two sensors, as below (I)
Proximit
charts. sensor
B
(J)
A Photo
electri c
Face to Face sensor
Parallel
When sensors are mounted on metallic panel, it must be prevented sensors from being affected by any
(K)
metallic object except target. Therefore, be sure to provide a minimum distance as below chart. Pressur
sensor
m
ød n (L)
Rotary
ℓ encoder
ℓ
ℓ
Unit:mm (M)
5-Phase
stepping
Model PRCMT12-2D PRCMT12-4D PRCMT18-5D PRCMT18-8D PRCMT30-10D PRCMT30-15D motor &
PRCM12-2D PRCM12-4D PRCM(L)18-5D PRCM(L)18-8D PRCM(L)30-10D PRCM(L)30-15D Driver &
Controlle
Item PRCM12-2A PRCM12-4A PRCM(L)18-5A PRCM(L)18-8A PRCM(L)30-10A PRCM(L)30-15A
A 12 24 30 48 60 90
B 24 36 36 54 60 90
ℓ 0 11 0 14 0 15
ød 12 36 18 54 30 90
m 6 12 15 24 30 54
n 18 36 27 54 45 90
I-22