Вы находитесь на странице: 1из 2

CENTAUR 40

Gas Turbine Generator Set

Power Generation

General Specifications
Centaur ® 40 Gas Turbine
• Industrial, Single-Shaft • NEMA Class F Insulation • Turbine Compressor Cleaning Systems
• 11 Stage Axial Compressor • Class F Temperature Rise – On-Crank/On-Line
– Variable Inlet Guide Vanes and Stators • Class B Temperature Rise* – Portable Cleaning Tank*
– Pressure Ratio: 10:1 • Continuous Duty Rating Voltages: • Package Power
– Inlet Airflow: 18.7 kg/sec (41.3 lb/sec) – 3300, 6600, 11 000 (50Hz) – 120VDC Battery/Charger System*
– Vertically Split Case – 4160, 6900, 12 470, 13 200, 13 800 (60Hz) • Turbotronic™ On-Skid Gas Turbine and
• Combustion Chamber, Annular-Type Generator Control System Features
Package
– 10 Conventional Fuel Injectors or – Combination Generator Control Module
• Mechanical Construction with Load Share, Auto Synchronization,
12 Lean-Premixed, Dry Low – Steel Base Frame with Drip Pans
Emissions SoLoNOx™ Injectors Voltage Control
– 316L Stainless Steel Piping – Standard Display with Discrete Event Log,
– Single Torch Ignitor System – Compression Type Tube Fittings Strip Chart, Historical Trend,
• Power Turbine • Start System Maintenance Screen
– 3-Stage Reaction – Direct Drive AC Motor with VFD Control – Vibration and Temperature Monitoring
– Clockwise Rotation • Package Electrical Certification – English Display Text and Labels
• Bearings – NEC, CSA Class 1, Group D, Div.2 – Spanish, Portuguese, German, French
– 3 Radial Journal: Tilt-Pad • Fuel System or Simplified Chinese Display Text
– Thrust, Active: Tilt-Pad – Natural Gas and Labels*
– Thrust, Inactive: Fixed Tapered Land – Diesel* – Auxiliary and Remote Display/Control
• Coatings – Dual (Natural Gas and Diesel)* Terminals*
– Compressor: Inorganic Aluminum – Low BTU Gas* – Turbine Performance Map*
– Turbine and Nozzle Blades: Precious • Integrated Lube Oil System – KW Import Control*
Metal Diffusion Aluminide – Turbine-Driven Lube Pump – KVAR/Power Factor Control*
• Vibration Monitoring – AC Motor Driven Pre/Post Lube Pump – ControlNet Redundant Media, Ethernet,
– DC Motor Driven Backup Lube Pump Data Highway Plus or Modbus
– Velocity Transducers
– Air to Oil Cooler RS232C/422/485 Supervisory Interface*
Main Reduction Drive – Water to Oil Cooler* – Heat Recovery Application Interface*
• Epicyclic Type – Integral Lube Oil Tank – Multi-Unit Applications: Load Shed Control,
– 1500 or 1800 rpm (50 or 60 Hz) – Lube Oil Tank Heater Import/Export or kW/KVAR Control Panels*
– Vibration monitoring: Acceleration – Lube Oil Filter – InSight Platform™ Equipment Health
Transducer – Duplex Lube Oil Filter* Management*
Generator – Oil Tank Vent Separator with – Printer/Logger*
Flame Arrestor • Electrical System Options
• 4 Pole, 3 Phase, 6 Wire, Wye Connected,
• Air Inlet and Exhaust Systems – Neutral Grounding Resistor or Transformer*
Synchronous with Permanent Magnet
– Carbon Steel – Switchgear and Generator Protective Relay*
Generator Exciter
– Stainless Steel* – Motor Control Center with Automatic
• Available Construction Types: Transfer Switch*
– Open Drip-Proof Construction – Barrier Type Filters
– Self-Cleaning Filters • Documentation
– CACA/TEAAC (Closed Air, Cooling Air/
– Inlet and Exhaust Silencers – Drawings
Totally Enclosed, Air to Air Cooling)*
– Inlet Evaporative Cooler* – Quality Control Data Book
– CACW/TEWAC (Closed Air, Cooling
– Inlet Chiller Coils* – Inspection and Test Plan
Water/Totally Enclosed, Water to Air
• Enclosure – Test Reports
Cooling)*
– Complete Package – O&M Manuals
• Sleeve Bearings
– Driver Only* • Factory Testing of Turbine
• Vibration Monitoring; Velocity Transducers – Fire Detection and CO2 Suppression • Factory Testing of Package Systems
• Vibration Monitoring; Displacement System – Non-Dynamic
Transducers* – Dynamic

* Option
CENTAUR 40
Gas Turbine Generator Set

Power Generation

Performance Available Power


Output Power 3515 kWe 5000 14.5
(13,750)
Heat Rate 12 910 kJ/kWe-hr
(12,240 Btu/kWe-hr) Output Power

HEAT RATE, MJ/kW-hr (Btu/kWe-hr)


14.0
4500
(13,270)
Exhaust Flow 68 365 kg/hr

OUTPUT POWER, kWe


(150,715 lb/hr)
13.5
Exhaust Temp. 445°C 4000 (12,320)
(830°F)

13.0
Application Performance 3500 (12,320)
Steam (Unfired) 8.9 tonnes/hr
(19,600 lb/hr)
12.5
Steam (Fired) 50.9 tonnes/hr 3000 (11,850)
1536°C (2800°F) (112,190 lb/hr) Heat Rate
12.0
Chilling (Absorp.) 7670 kW
(2180 refrigeration tons) 2500 (11,370)
-30.0 -15.0 0.0 15.0 30.0 45.0
Nominal rating – per ISO (-22) (5) (32) (59) (86) (113)
At 15°C (59°F), sea level
INLET AIR TEMPERATURE, °C (°F)
No inlet/exhaust losses DS40PG-002M

Relative humidity 60%


Natural gas fuel with
LHV = 35 MJ/Nm3 (940 Btu/scf)
No accessory losses
Engine efficiency: 27.9%
(measured at generator terminals)

Enclosure Access and Maintenance Space

3.0 mm
3048 m 9.8 m
9800 mm
(10’ 4”) (32’ 3")
(32' 3”)
(9' 10")

MINIMUM SPACE CLEARANCE


2.6 mm
2477 m GENERATOR REQUIRED FOR ENCLOSURE
(8’(8'
1-1/2”)
6") MAINTENANCE ACCESS DOORS AND
ROUTINE OPERATION
AND MAINTENANCE

MINIMUM CLEARANCE REQUIRED


3.0 mm
3048 m
FOR ENGINE REMOVAL (9’11”)
(9' 10")

9.8 m
9754 mm
(32’ 3")
(32' 0”)
DS40,50,60PG-003C
Package Height: 3.2 m (10' 5")
Package Weight: 30 460 kg (67,150 lb) Dry weight, enclosed height

Solar Turbines Incorporated


P.O. Box 85376 FOR MORE INFORMATION
San Diego, CA 92186-5376 Telephone: (+1) 619-544-5352
Caterpillar is a trademark of Caterpillar Inc.
Solar, Centaur, SoLoNOx, InSight Platform and Turbotronic are trademarks of Solar Turbines Incorporated. Email: powergen@solarturbines.com
Specifications subject to change without notice. Internet: www.solarturbines.com
© 2018 Solar Turbines Incorporated. All rights reserved.
DS40PG/1118/EO