Вы находитесь на странице: 1из 7

E-02

S-01

S-02
A B C E-02
D E F
250
30,500

2,800 8,550 7,400 8,550 2,800


400 2,000 1,600 6,750 1,600 5,800 1,600 6,750 1,600 2,000 400

250
1 pv pv pv pv pv
1

250
250
400
1,600

1,600
800
400

400

800
RETAIL SPACE

75
75
High level steel casement

800
200 200 75 250
windows with grille to 850 764 1,800
Granite tiles floor f.

75
4,724
shedule

800
-1,700

75
ffl to match existing

800
fulbora sewer line level +500

RETAIL SPACE outlet


7,580

7,580
pv pv

200

200
7,055
7,055

7,055
5,375

5,376
fall

1,100
steps up

Granite tiles floor f. pv

1,800
tread=300
riser=150

200
pv

200
-1,700
RETAIL SPACE

75
fall
pv
200
2,500
250 61
4,200
100 200
850
200
830
75
830
75
830
250

pv
1,600

1,600
2 2

650
1

9
200
650

650
18 x 167 = 3,000
250 200 250
Cable 4,361 1,539 2,150
termination
19,142

room
10 pv

ACESS

9,926
FROM
GROUND RETAIL SPACE
FLOOR

18

17

16

15

14

13

12

11
51 No. COLD WATER
5,872

5,871
7,470

7,470
STORAGE TANK lobby

7,000

6,820
7,000
pv

SERVICE
200 200 200
2,200 2,200
Granite tiles floor f. -2,700 -2,700
750 900 1,700 900 750

200

E-03
27,500
E-03

400 400

1,950
896 2,400 7,127 2,400 4,031
LIFT PIT
2,423 pv 7,127 2,400 896
LIFT PIT

250
1,600

1,600
3 pv
3

200

650
fall to sump

650
650

250 250 250


PUMP ROOM 10,750 8,250
3,113
4,730

4,730
3,900
powerfloated RC ff.
3,900

pv

5,650
2,400 4,054 2,400 7,127 2,400 896

6,800
4 4
25

650
1,
60

650

RETAIL SPACE

11,900
0
2,520

2,520
-1,700
High level steel casement
1,

Granite tiles floor f. NOTES REVISION DATE DESCRIPTION SIGN


76

windows with grille to


7

shedule 1. All dimensions to be checked on site.

1,600
5 5 Written dimensions to be followed in
1,
60

250 250 250 preference to scaled dimensions.Any


8,358

650
10,750 8,250
pv discrepancies to be confirmed with
2,700

2,700
6,800
6,800

the lead consultant.


250 250 2. Depth of foundation to be determined
11

2,603
19,250
on site.But to be not less than
,8
20

6 6
1200mm deep.
3. D.P.C to be 3 ply bituminus felt. ARCHITECT :
6,

4. Concrete driveways to be finished


82
2,150

2,150
with cabro work.Tiles sloping towards
8

1,600
main road.
5. All walls less than 200 thick to be

7 7

250
400

reinforced with hoop iron at every


alternate course.
400

2,392 1,600 5,800 1,600 2,360 1,600 6,390 400


6. Pv denotes permanent vent. CLIENT: KALYAN RAVJI HIRANI
7. All reinforced concrete works to AND
2,800 5,358 3,192 7,400 8,550 2,800 be in accordance with structural
RAVJI SHANTABEN KALYAN
engineer,s specifications.
8,340 22,142 8. All sanitary,s work to be in
accordance with M.O.H.rules and CLIENT'S SIGNATURE:

A B C D E F regulations.
S-02

9. Where drainage pipes pass under JOB : PROPOSED FLATS AND OFFICES
building ON LR 209/66/19
E-04 driveways and carparks,pipes to be MUTHITHI ROAD, WESTLANDS
encased in 150 conc. surround or
to be of cast iron.
S-01

DRAWING TITLE :
10. N.C.C water meters to be positioned lower ground floor, groundfloor
at least 300mm above ground level.
11. All dimensions to be in MM Scale : as shown DATE : 1/14/2019

LOWER GROUND FLOOR to


WM denotes water meter for NCC and

be above 300mm above ground


Drawn :C.M.O. Checked :

Job NO. 01/2016


E-02

±0.000 30,500

S-01
450x300m wide drain with

S-02
GENERATOR ROOM
MS grating cover

5,000

5,000
A B
350mm high masonry planter box C D E F

50 200
7 6 5 4 3 2 1
1 1
sentry box
Granite tiles floor f.
EXIT
+300

RAMP TO UPPER PARKING LEVEL


aluminium Louver window 20.00 % 20.00 %
to schedule Ribbed concrete floor f.

14,902
2 2
fall
18,646

Ribbed concrete floor f.

FROM LOWER
PARKING FLOOR
Tread=300
Riser=150
PARKING

1
Ribbed concrete floor f.
6m wide driveway

lift lobby
2 Granite tiles floor f.
void to retail below

27,500
E-01

E-03
3

200
3 3

+300
pv

NOTES REVISION DATE DESCRIPTION SIGN

4 4 1. All dimensions to be checked on site.


Written dimensions to be followed in

12,148
preference to scaled dimensions.Any
High level glass discrepancies to be confirmed with
block windows to the lead consultant.
schedule 2. Depth of foundation to be determined
5 5
8,654

450x300m wide drain with pv on site.But to be not less than


MS grating cover 1200mm deep.
l
fal
3. D.P.C to be 3 ply bituminus felt. ARCHITECT :
4. Concrete driveways to be finished
ENT void to retail below with cabro work.Tiles sloping towards
RY main road.
5. All walls less than 200 thick to be
6 6 reinforced with hoop iron at every
alternate course.
EXI
T sentry box 6. Pv denotes permanent vent. CLIENT: KALYAN RAVJI HIRANI
Granite tiles floor f.
7. All reinforced concrete works to
be in accordance with structural

7 7
200

engineer,s specifications.
8. All sanitary,s work to be in
accordance with M.O.H.rules and CLIENT'S SIGNATURE:
200 200 regulations.
8,300 21,800 9. Where drainage pipes pass under
building
200 driveways and carparks,pipes to be
8,300 22,000 encased in 150 conc. surround or

A B C D E F to be of cast iron.
10. N.C.C water meters to be positioned
DRAWING TITLE :
S-01

S-02

at least 300mm above ground level.


E-04 11. All dimensions to be in MM Scale : as shown DATE : 1/14/2019

GROUND FLOOR to
WM denotes water meter for NCC and

be above 300mm above ground


Drawn :C.M.O. Checked :

Job NO. 01/2016


E-02

S-01

S-02
A B C D E F
30,500

50 200
1 1

RAMP TO UPPER PARKING LEVEL


20.00 % 20.00 %
Ribbed concrete floor f.
2

14,902
2 2
18,646

Ribbed concrete floor f.

FROM LOWER
PARKING FLOOR
Tread=300
Riser=150
PARKING

4 Ribbed concrete floor f.


6m wide driveway

lift lobby
5 Granite tiles floor f.
void to retail below

27,500
E-01

E-03
6

200
3 9
3

7
8

NOTES REVISION DATE DESCRIPTION SIGN

4 4 1. All dimensions to be checked on site.


Written dimensions to be followed in

12,148
preference to scaled dimensions.Any
discrepancies to be confirmed with
the lead consultant.
2. Depth of foundation to be determined
5 5
8,654

pv
RAMP FROM LOWER on site.But to be not less than
1200mm deep.
PARKING LEVEL 3. D.P.C to be 3 ply bituminus felt. ARCHITECT :
20.00 % 4. Concrete driveways to be finished
with cabro work.Tiles sloping towards
main road.
5. All walls less than 200 thick to be
6 6 reinforced with hoop iron at every
alternate course.
6. Pv denotes permanent vent. CLIENT: KALYAN RAVJI HIRANI
7. All reinforced concrete works to
be in accordance with structural

7 7
200

engineer,s specifications.
8. All sanitary,s work to be in
accordance with M.O.H.rules and CLIENT'S SIGNATURE:
200 200 regulations.
8,300 21,800 9. Where drainage pipes pass under
building
200 driveways and carparks,pipes to be
8,300 22,000 encased in 150 conc. surround or

A B C D E F to be of cast iron.
10. N.C.C water meters to be positioned
DRAWING TITLE :
S-01

S-02

at least 300mm above ground level.


E-04 11. All dimensions to be in MM Scale : as shown DATE : 1/14/2019
WM denotes water meter for NCC and
to Drawn :C.M.O. Checked :

PARKING FLOOR lower be above 300mm above ground


Job NO. 01/2016
E-02

S-01

S-02
A B C 30,500 D E F

1 1

7,625
RAMP FROM LOWER PARKING LEVEL 20.00 %
Ribbed concrete floor f.
2

3
2 2

9
electrical/telecom. duct

Ribbed concrete floor f.


18 x 167 = 3,000
18,646

FROM LOWER
PARKING FLOOR
Tread=300 10
Riser=150

PARKING
18

17

16

15

14

13

12

11

7,250
fall
LIFT LOBBY
5
+1,800

27,500
E-01

E-03
Ribbed concrete floor f.

Ribbed concrete floor f.


fire hose reel

3 6
3

6M WIDE DRIVEWAY
PARKING
300X900mm
Reinforced

4,925
concrete upstand 13
7
beam plastered
and painted

14 NOTES REVISION DATE DESCRIPTION SIGN

4 8
4 1. All dimensions to be checked on site.
Written dimensions to be followed in

2,525
preference to scaled dimensions.Any
discrepancies to be confirmed with

Ribbed concrete floor f.


the lead consultant.
2. Depth of foundation to be determined
5 5
9
on site.But to be not less than

PARKING
RAMP TO UPPER PARKING LEVEL 1200mm deep.
Ribbed concrete floor f. 3. D.P.C to be 3 ply bituminus felt.

2,725
ARCHITECT :
20.00 % 20.00 % 4. Concrete driveways to be finished
with cabro work.Tiles sloping towards
10 main road.
5. All walls less than 200 thick to be
11

6 6 reinforced with hoop iron at every


,7

alternate course.

2,150
38

6. Pv denotes permanent vent. CLIENT: KALYAN RAVJI HIRANI


7. All reinforced concrete works to
11 be in accordance with structural

7 7

150
engineer,s specifications.
8. All sanitary,s work to be in
accordance with M.O.H.rules and CLIENT'S SIGNATURE:
regulations.
9. Where drainage pipes pass under
building
driveways and carparks,pipes to be
encased in 150 conc. surround or

A B C D
22,000 E F to be of cast iron. DRAWING TITLE :
S-01

S-02

10. N.C.C water meters to be positioned


at least 300mm above ground level.
E-04 11. All dimensions to be in MM Scale : as shown DATE : 1/14/2019
WM denotes water meter for NCC and
to Drawn :C.M.O. Checked :

PARKING FLOOR upper be above 300mm above ground


Job NO. 01/2016
E-02

S-01

S-02
A B C200 S-57

400 200
D E F
3,300 2,900
2,800 8,580 7,570 8,950
pv pv

200
pv pv

400
S-59
200

200

200

1,200
1,200

pv
yard yard

2,550

3,700
3,500
LOUNGE LOUNGE

4,250
MASTER MASTER
BEDROOM ceramic tiles ceramic tiles BEDROOM

pv

4,315

150
ceramic tiles ceramic tiles

5,500
600
850 150 2,600 600

8,129
pv

200

200
pv
200 4,800 150 600 150

150
KITCHEN KITCHEN
150 600 150

1,800
ceramic tiles ceramic tiles

6,675
6,672
2,251
2,600 600
wc/sh 2,250

1,185

1,100

3,550
ceramic tiles 750
wc/sh

150

150

150

3,750
150

wc/sh

1,100

1,100

1,100
1,575

FOYER
ceramic tiles
wc/sh

71 129
600
150

150
200

2 2
pv

200
electrical/telecom. duct
136.7 m2 136.7 m2

3,625
2,950

S-58

3,475

3,475
BEDROOM BEDROOM
2,100

2,100
2,725
ceramic tiles
DINING DINING
ceramic tiles ceramic tiles
200 3,600 600 150

200
200

975

975
200

200

200

200

200
7,471

1,200

7,400
200 9,147 200 1,500 200 1,200 3,000 1,200 200

2,430
200 1,800 200
LIFT LOBBY
S-60

200
3,000

3,000
4,325

4,325

4,325
LOUNGE DINING LOUNGE
27,855

27,505
ceramic tiles ceramic tiles

200

2,927
DINING
LIFT 1 LIFT 2

2,150
1,200 1,301

1,200 1,302
fire hose reel

3 3
150
E-01

E-03
150

150
150
1,656

1,500
STORE STORE
200 2,201 200 4,700 150 1,200 150 3,350 200 2,800 200 2,800 200 3,350 150 1,200 150 4,700 200 2,199 200
2,806

F
BEDROOM BEDROOM
200

3,100
KITCHEN KITCHEN
F
4,730

4,730
4,404
2,455
2,000

2,000

wc/sh
600

wc/sh

3,073
FOYER

150
150 200

pv
1,350

pv
yard yard
850

850

4 4
pv
3,350

150
150

200

2,000
1,998
2,520

2,520
wc/sh pv wc/sh
2,800

150 900 600 150 4,700 200

10,653
BEDROOM
150

150
5 150 630 970 150 2,950
MASTER
200 5 NOTES REVISION DATE DESCRIPTION SIGN

pv 1. All dimensions to be checked on site.


BEDROO
1,485
6,800

200 3,050 150 900 600 150


Written dimensions to be followed in
2,700

2,700
pv M
MASTER preference to scaled dimensions.Any

0
discrepancies to be confirmed with

40
BEDROOM

1,
5,150

5,150
the lead consultant.

6 6 2. Depth of foundation to be determined


1,765

on site.But to be not less than

0
10
150 4,700 200

2,
1200mm deep.
2,150

2,150
3. D.P.C to be 3 ply bituminus felt. ARCHITECT :
849

4. Concrete driveways to be finished

9
pv

13
1,
with cabro work.Tiles sloping towards

7 7
200

451

main road.

0
20
200

250

5. All walls less than 200 thick to be

1,
reinforced with hoop iron at every

3
22
alternate course.
3,813 1,487 1,765 849 16,103 849 805 1,485 1,245 900 1,199 6. Pv denotes permanent vent. CLIENT: KALYAN RAVJI HIRANI
7. All reinforced concrete works to AND
2,800 8,580 7,570 8,950 2,275
be in accordance with structural
30,500 RAVJI SHANTABEN KALYAN
engineer,s specifications.

A B C S-61
D E F 8. All sanitary,s work to be in
accordance with M.O.H.rules and
regulations.
CLIENT'S SIGNATURE:

9. Where drainage pipes pass under JOB : PROPOSED FLATS AND OFFICES
building ON LR 209/66/19
driveways and carparks,pipes to be MUTHITHI ROAD, WESTLANDS
encased in 150 conc. surround or
to be of cast iron. DRAWING TITLE :
10. N.C.C water meters to be positioned
at least 300mm above ground level.
RESIDENTIAL FLOOR PLAN: LEVEL 7 TO 12 615.5M2 11. All dimensions to be in MM
WM denotes water meter for NCC and
Scale : as shown DATE : 1/14/2019

Scale: 1:100
to Drawn :C.M.O. Checked :
be above 300mm above ground
Job NO. 01/2016
A B C D E F
30,500

2,800 8,550 7,400 8,550 2,800


400 2,000 1,600 6,750 1,600 5,800 1,600 6,750 1,600 2,000 400

1 C4 C3 C3 C4 1
1,600

1,600
400

400

400
C4
C4
7,580

7,580
7,055

7,055

7,055
5,375

5,376
400 896 2,400 7,127 2,400 4,031 2,423 7,127 2,400 896 400

C2A C1A C1A C2A


1,600

1,600
2 2

650

650

650
C4
C4
19,142

5,872

5,871
7,470

7,470
6,820
7,000

7,000
200 2,200 200 2,200 200

750 900 1,700 900 750

27,500
1,950 200
400 896 2,400 7,127 2,400 4,031 2,423 7,127 2,400 896 400

C2A C2A
1,600

1,600
3 200
3

650
C4 C1A C1A
650

650
C4
3,113
4,730

4,730
3,900

3,900
2,400 4,054 2,400 7,127 2,400 896

5,650
6,800
NOTES REVISION DATE DESCRIPTION SIGN

4 4
25

1. All dimensions to be checked on site.


C4 Written dimensions to be followed in
1,

C1A C1A preference to scaled dimensions.Any


60

650

650
discrepancies to be confirmed with
0
2,520

2,520
the lead consultant.
2. Depth of foundation to be determined
1,
76

on site.But to be not less than


7

1200mm deep.

1,600
5 5
C2A
C4 3. D.P.C to be 3 ply bituminus felt. ARCHITECT :
1,

4. Concrete driveways to be finished


60
8,358

with cabro work.Tiles sloping towards


0

650
C4 main road.
2,700

2,700
6,800

6,800

5. All walls less than 200 thick to be


reinforced with hoop iron at every
11

2,603
alternate course.
,8

6. Pv denotes permanent vent. CLIENT: KALYAN RAVJI HIRANI


20

6 6 7. All reinforced concrete works to


be in accordance with structural
AND

RAVJI SHANTABEN KALYAN


6,

engineer,s specifications.
82
2,150

2,150
8. All sanitary,s work to be in
8

CLIENT'S SIGNATURE:

1,600
accordance with M.O.H.rules and
regulations.
C3 C3 C4
7 7
9. Where drainage pipes pass under JOB : PROPOSED FLATS AND OFFICES
C4 building ON LR 209/66/19
400

400

driveways and carparks,pipes to be MUTHITHI ROAD, WESTLANDS


encased in 150 conc. surround or
2,392 1,600 5,800 1,600 2,360 1,600 6,390 400 to be of cast iron. DRAWING TITLE :
10. N.C.C water meters to be positioned columns setting out
2,800 5,358 3,192 7,400 8,550 2,800
at least 300mm above ground level.
11. All dimensions to be in MM Scale : as shown DATE : 1/14/2019
8,340 22,142 WM denotes water meter for NCC and
to Drawn :C.M.O. Checked :

A B C D E F be above 300mm above ground


Job NO. 01/2016
+65.100 +65.100
19 Story 19 Story

+62.000 +62.000
18 Story 18 Story

+58.500 +58.500
17 roof terrace 17 roof terrace

+55.000 +55.000
16 office 12 16 office 12

+51.500 +51.500
15 office 11 15 office 11

+48.000 +48.000
14 office 10 14 office 10

+44.500 +44.500
13 office 9 13 office 9

+41.000 +41.000
12 office 8 12 office 8

+37.500 +37.500
11 office 7 11 office 7

+34.000 +34.000
10 office 6 10 office 6
NOTES
1. All dimensions to be checked on site.
Written dimensions to be followed in
preference to scaled dimensions.Any
+30.500 +30.500 discrepancies to be confirmed with
9 office 5 9 office 5 the lead consultant.
2. Depth of foundation to be determined
on site.But to be not less than
1200mm deep.
3. D.P.C to be 3 ply bituminus felt.
+27.000 +27.000 4. Concrete driveways to be finished
8 office 4 8 office 4 with cabro work.Tiles sloping towards
main road.
5. All walls less than 200 thick to be
reinforced with hoop iron at every
alternate course.
6. Pv denotes permanent vent.
+23.500 +23.500 7. All reinforced concrete works to
7 office 3 7 office 3 be in accordance with structural
engineer,s specifications.
8. All sanitary,s work to be in
accordance with M.O.H.rules and
regulations.
+20.000 +20.000 9. Where drainage pipes pass under
6 office 2 6 office 2 building
driveways and carparks,pipes to be
encased in 150 conc. surround or
to be of cast iron.
10. N.C.C water meters to be positioned
at least 300mm above ground level.
+16.500 +16.500
5 office 1 5 office 1 11. All dimensions to be in MM
WM denotes water meter for NCC and
to
be above 300mm above ground

REVISION DATE DESCRIPTION SIGN


+12.000 +12.000
4 parking 4 4 parking 4

F E D C B A
+9.000 +9.000
3 parking 3 3 parking 3

ARCHITECT :

+6.000 +6.000
2 parking 2 2 parking 2

CLIENT: KALYAN RAVJI HIRANI


+3.000 +3.000
1 parking 1 1 parking 1

CLIENT'S SIGNATURE:
±0.000 ±0.000
0 ground 0 ground

DRAWING TITLE :

ELEVATION E-01 Scale : 1:100 DATE : 1/14/2019

Drawn : Checked :
Scale: 1:100
Job NO. 01

Вам также может понравиться