Summary
Finding
• Total in Northern West are 52 NodeBs with active attempt of DC-HSDPA (290 cells)
• Of 52 NodeBs DC-HSDPA applied, no issues related to configuration (same group, TCELL, Multigroup, adjacent frequency, etc)
• There are 57 cells with improper DC-HSDPA implementation (No attempt DC-HSDPA but parameter DC-HSDPA active)
Highlight (need to be trial)
• Based on Huawei Documentation, there are two types of DC-HSDPA RRU configuration
- Shared 1 RRU
- Dual RRU
From static test result (speed test) in macrocell 3G_E721G_3G_GRAHA_XL_MEDAN (Dual RRU) with direct connection
to MSTP (means no issue at BW transmission), throughput DC-HSDPA is still low
• Proposed to configured with shared one RRU for 1 sector

HUAWEI TECHNOLOGIES CO., LTD. Page 2


Overviews Analysis Summary

DC HSDPA PREREQUISITES (RF Planning)

In order to deploy DC HSDPA feature optimally, below are the required information (mandatory)
• Downlink 64QAM & Downlink L2_Enhancend feature must be active (RNC & NodeB License)
• DC-HSDPA Function per cell must be active
• The two DC-HSDPA cells must belong to the same sector
• The two DC-HSDPA cells must belong to the same baseband board
• The two DC-HSDPA cells of a DC-HSDPA group are in the same downlink resource group of a NodeB
• The two DC-HSDPA of the same sector share one transmit channel, that is, share one RRU.When using dual RRU, the cascading
mode should be used between two’s RRU
• One local cell can belong to only one DC-HSDPA group
• The two DC-HSDPA cells of the same sector must have the same TCELL
• When the two DC-HSDPA cells of a DC-HSDPA group operate on adjacent frequencies, the difference between the values of the
UARFCNDownlink parameters for the two cells must be greater than 19 and meanwhile less than or equal to 25. When the two DC-
HSDPA cells of a DC-HSDPA group operate on non-adjacent frequencies, the difference between the values of the UARFCNDownlink
parameters for the two cells must be an integer multiple of 25
• The RNC software version is RAN12.0 or later
• The NodeB software version is RAN12.0 or later
• UEs must belong to HS-DSCH category 21 or higher
• For other parameters, please see Huawei Docs/HeDex

HUAWEI TECHNOLOGIES CO., LTD. Page 3


Overviews Analysis Summary

Downlink 64QAM,DL_L2_Enhancend & DC-HSDPA Feature


RNC License

NODEB License

• RNC : DL2Enhanced & 42 Mbps (64QAM)


License active
• NodeB : DL64QAM & DC-HSDPA License active

HUAWEI TECHNOLOGIES CO., LTD. Page 4


Overviews Analysis Summary

Same Sector & Same Multigroup Carrier

• Same sector is configured in the same multigroup


• Same sector : Loccell 1-4, Loccell 2-5, Locell 3-6

HUAWEI TECHNOLOGIES CO., LTD. Page 5


Overviews Analysis Summary

Same Baseband Group

• If only two carriers applied in the nodeB, all carriers are set to the same BasebandGroup ID (e.g BBGroup Id 0)
• If three carriers applied in the nodeB, DC-HSDPA carriers must be set in the same Baseband Group ID

HUAWEI TECHNOLOGIES CO., LTD. Page 6


Overviews Analysis Summary

Shared One RRU or Dual RRU Cascade

• Shared One RRU • Dual RRU (Cascade Mode)


- Sector 1 of F1 & F2 are configured in RRU slot 1 - Sector 1 of F1 is configured in RRU slot 0, F2 slot 1
- Sector 2 of F1 & F2 are configured in RRU slot 3 - Sector 2 of F1 is configured in RRU slot 2, F2 slot 3
- Sector 3 of F1 & F2 are configured in RRU slot 5 - Sector 3 of F1 is configured in RRU slot 4, F2 slot 5

Cascade Mode :

HUAWEI TECHNOLOGIES CO., LTD. Page 7


Overviews Analysis Summary

Same sectors Same TCELL

• TCell of DC carrier group cells or MC carrier group cells must be the same
• If Tcell of same sector are not the same, DC is not active/no attempt of DC HSDPA

• After set Tcell properly


of sector-1 & 3
GrahaXLMedan,
Attempt DC-HSDPA of
each cells exist

HUAWEI TECHNOLOGIES CO., LTD. Page 8


Overviews Analysis Summary

Adjacent Frequency of DC HSDPA Cells


• If two DC-HSDPA cells of a DC-HSDPA group operate on adjacent frequencies, the difference between the values of the
UARFCNDownlink parameters for the two cells must be greater than 19 and meanwhile less than or equal to 25

• If the two DC-HSDPA cells of a DC-HSDPA group operate on non-adjacent frequencies, the difference between the values of the
UARFCNDownlink parameters for the two cells must be an integer multiple of 25

XL DC-Carrier Implementation
Carrier UARFCNUPLINK UARFCNDOWNLINK BandWidth Configuration of DC-HSDPA Carrier Spacing Carrier Status
F3 9788 10738 5 Mhz F1-F2 25 Adjacent Frequency
F1 9813 10763 5 Mhz F1-F3 25 Non-Adjacent Frequency
F2 9838 10788 5 Mhz F2-F3 50 Adjacent Frequency

• F2-F3 (non adjacent frequency DC-HSDPA cells) are not recommended to be applied
• Based on active attempt DC-HSDPA, no issue with F2-F3 implementation as DC-HSDPA cells

HUAWEI TECHNOLOGIES CO., LTD. Page 9


Overviews Analysis Summary

Adjacent Frequency of DC HSDPA Cells


XL DC-Carrier Implementation
NE Name NODEBNAME F1 F2 NE Name NODEBNAME F1 F2
RNBKT01 3251350G_3G_PROF_HAMKA_BUKITTINGGI 3 3 RNMDN06 322PC115G_3G_MEDAN_PLAZA 2 2 • Based on active
RNBKT01 325PX156G_3G_PLAZA_BUKITINGGI 3 3 RNMDN06 322PX096G_3G_RSU_PERMATA_BUNDA 1 1 attempt DC-
RNBKT01 325PX157G_3G_PASAR_BANTO 3 3 RNMDN06 E702G_3G_SEI_PUTIH_TIMUR 3 3 HSDPA, no issue
RNBKT01 E985G_3G_BUKIT_TINGGI 3 3 RNMDN06 E706G_3G_KAMPUNG_DARAT_RELOC 3 3
RNBKT01 X325AC18G_3G_SELARAS_AIR 2 2 RNMDN06 E720G_3G_KESAWAN 3 3
with F2-F3
RNBTM02 3241123G_3G_BUKIT_SENTOSA 3 3 RNMDN06 E721G_3G_GRAHA_XL_MEDAN 3 3 implementation
RNBTM02 3241124G_3G_PERUM_PURI_AGUNG 3 3 RNMDN06 MC3223285G_3G_MC_SEI_PUTIH_TENGAH 3 3 as DC-HSDPA
RNBTM02 3242126G_3G_MUKAKUNING_INDUSTRI 3 3 RNMDN06 MC3223768G_3G_MERANTI_MEDAN 3 3
RNBTM02 3242127G_BIDA_AYU_BATAM_G3 3 3 RNMDN06 MC3223777G_3G_MC_PJ_NEHRU_MEDAN 3 3
cells
RNBTM02 324D083G_3G_DORMITORY_DUA 3 3 RNMDN06 MC322C288G_3G_LEE_GARDEN_HOTEL 3 3
RNBTM02 324PX196G_3G_PANBILL 3 3 RNMDN06 MC322C297G_3G_MC_ASIA_MEGAMAS 3 3 • Total in
RNBTM02 E903G_3G_MUKA_KUNING 3 3 RNMDN06 PC114G_3G_SUN_PLAZA 3 3
RNBTM02 E910G_3G_DORMITORI_MUKA_KUNING 3 3 Northern West
RNMDN06 PC254G_3G_MEDAN_FAIR_PLAZA 3 3
RNBTM02 E914G_3G_PANBIL 3 3 RNMDN06 X322PC075G_3G_MEDAN_CENTER_POIN 3 3 are 52 NodeBs
RNBTM02 E926G_3G_GARDEN_AYU 3 3 RNMDN07 3223254G_3G_PADANGBULAN_RUKO 3 3 with active
RNBTM02 X324D042G_3G_RANAI_NATUNA 3 3 RNMDN07 3223603G_3G_BABURA_SUNGGAL 3 3
RNMDN02 322C189G_3G_PERUM_CEMARA_ASRI 3 3 attempt of DC-
RNMDN07 322B554G_3G_KOMPLEK_CITRA_WISATA 3 3
RNMDN02 322C295G_3G_CEMARA_ASRI_TIMUR 3 3 RNMDN07 322C218G_3G_MEDAN_JOHOR_TIMUR 3 3 HSDPA (290
RNMDN03 322PC073G_3G_BANDARA_INTERNATIONAL_KUALANAMU 2 2 cells)
RNMDN07 322C296G_3G_TAMAN_SETIABUDI_UTARA 3 3
RNMDN03 322PC100G_3G_BANDARA_KUALANAMU2 3 3
RNMDN07 E733G_3G_TANJUNG_REJO 1 1
RNMDN03 X322AF63G_3G_PANGKALAN_SUSU_LANGKAT 3 3
RNMDN07 E734G_3G_MEDAN_JOHOR 3 3
RNMDN06 3222576G_3G_AHMAD_YANI_MEDAN 3 3
RNMDN07 E879G_3G_TAMAN_SETIABUDI 3 3
RNMDN06 3223259G_3G_SUKADAMAI_PALADIUM 3 3
RNMDN07 MC3223122G_3G_MC_AYAHANDA_MEDAN 3 3
RNMDN06 3223693G_3G_SIMPANG_ZAINUL_ARIFIN 3 3
RNMDN07 MC3223853G_3G_MC_CYCAS_RAYA_SETIABUDI 3 3
RNMDN06 322C187G_3G_RADEN_SALEH 3 3
RNPDP01 3251307G_3G_HOTEL_PANGERAN 3 3
RNMDN06 322MC5515G_3G_PERUM_MEGAMAS 1 1
RNPDP01 325MC5401G_3G_SIMPANG_KINOL 1 1

HUAWEI TECHNOLOGIES CO., LTD. Page 10


Overviews Analysis Summary

Current Issue of DC-HSDPA Implementation


• 57 cells experience improper DC-HSDPA implementation
• Need to confirm whether these cells are DC-HSDPA activated as planned by RND

Carrier Carrier Carrier


Issue Grand Total Status
F1 F2 F3
Board Faulty 1 1 2 Halted/not active
DC-HSDPA requires 2 carriers cells
Licence Active 9 - 1 RRU (DC F1-F3, but F1 not active) 36 36
activated, not one only
DC-HSDPA requires 2 carriers cells
Licence Active 9 - 1 RRU (DC F2-F3, but F2 not active) 3 3
activated, not one only
Licence Active 9 - 1 RRU (DC F2-F3, but F2 not active,UL DC-HSDPA requires 2 carriers cells
3 3
BBGroup different) activated, not one only
DC-HSDPA requires 2 carriers cells
Licence Active 9 - 2 RRU (DC F1-F3 one RRU, but F1 not active) 9 9
activated, not one only
Wrong TCELL 2 2 4 Wrong Tcell (time offset)
Grand Total 3 3 51 57