Valve Valve Valve Valve Valve Valve Valve Pressure Item Valve Tag Break to Open Running Fully Open Break to Close Running End to Close MAST Pmin Actuator Actuator Actuator Actuator Actuator Actuator Actuator Displacement Actuator Model Break to Open Running Fully Open Break to Close Running End to Close MAX Open/close time / Real Real Real Real Real Real Fail Pressure Valve/Size/Class Safety factor Safety Factor Safety Factor Safety Factor Safety Factor Safety Factor Safety Factor Position Pmax 1 XV-2001 165.0 156.0 187.0 203.0 156.0 152.0 300.0 0.4 3.6 CP/S-045-200A/EL 549.8 253.3 327.9 498.4 229.8 297.7 549.8 2"#150 2.0 / 2.0 / 1.25 3.33 1.62 1.75 2.45 1.47 1.96 CLOSE 0.4 2 XV-2101/2201/2301 2,060.0 1,716.0 2,059.0 2,231.0 1,716.0 1,895.0 3400.0 0.4 47.15 GP-085S-485A/C6D 5,789.6 2,847.4 3,846.7 4,995.5 2,421.9 3,215.1 5789.6 8"#150 8.0 / 8.0 / 1.25 2.81 1.66 1.87 2.24 1.41 1.70 CLOSE 0.4
If Actuator MAX cell is coloured orange (or dark coloured) it means the actuator max torque/thrust exceeds 90% the Valve MAST. Please check data in this table carefully 1/1