Вы находитесь на странице: 1из 1

FLOWDYNE ENTERPRISES ,MUMBAI

QUALITY ASSURANCE PLAN

Ref : QAP-FD-CMP- Pump Model : Client :


Rel. Dt : Pump Qty. : P.O. No :
Rev. No : Item No :
Sr. COMPONENT / ASSY Characterstics Type of Check Category Quantum Acceptance Format of Inspection Authority
No. Checked of Check Norm Record 1 2 3 4
I RAW MATERIAL CONTROL
A I Casing Chem. & Phy. Properties Chem. Analysis & Phy. Test Major 1 / Heat As Per P.O. Foundry Cert. P R R -
ii Impeller --- " --- --- " --- " " --- " --- F'dry. / Lab. Cert. P R R -
iii Shaft --- " --- --- " --- " " --- " --- Lab Certificate P R R -
iv Adaptor Chemical Properties Chemical Analysis " " --- " --- --- " --- P R R -
v Stator Liner --- " --- --- " --- " " --- " --- Manuf. / Lab Cert. P R R -
vi Rotor Liner --- " --- --- " --- " " --- " --- --- " --- P P R -

II IN PROCESS CONTROL
A I Rotor Liner Surface Defects Dye Penetrant Test " 100% Should be free from Lab Report P R R -
welding defects
ii Stator Liner --- " --- --- " --- " 100% --- " --- --- " --- P R R -
B I Casing Surface Defects Dye Penetrant Test " 100% There shall be no FD'S Report - P R -
significant indications
ii Impeller --- " --- --- " --- " 100% --- " --- --- " --- - P R -
iii Rotor Assembly Welding Defects --- " --- " 100% --- " --- --- " --- - P R -
C I Stator Assembly Electrical Parameters Winding Resistance " 100% As per std. Procedure FD'S Report - P R -
( IS 325 )
Insulation Test " 100% --- " --- --- " --- - P R -
High Voltage Test " 100% --- " --- --- " --- - P R -
Load Test " 100% --- " --- --- " --- - P R -
D I Rotor Assembly Residual Unbalance Dynamic Balancing " 100% ISO 1940-1986 G 6.3 --- " --- - P R/W -

III PERFORMANCE TEST


I Overall Dimensions Dimensions Dimensional " 100% Apprd. Drgs. / Data Sheet FD'S Report - P R/W -
ii Performance Test H,Q,n Power Performance " 100% As per : API 610 / IS : 5120 --- " --- - P R/W -
iii Strip Down Test Abnormal Wear Visual Test " 1 / Type --- " --- --- " --- P R/W
iv Hydrostatic Test Integrity Test Hydrostatic Test " 100% --- " --- --- " --- - P R/W -
Legend : 1 - Subcontractor, 2 - Flowdyne, 3 - Inspection Agency / Clinet P - Perform, R - Review, W - Witness

For FLOWDYNE ENTERPRISES

Singh Anilkumar