II IN PROCESS CONTROL
A I Rotor Liner Surface Defects Dye Penetrant Test " 100% Should be free from Lab Report P R R -
welding defects
ii Stator Liner --- " --- --- " --- " 100% --- " --- --- " --- P R R -
B I Casing Surface Defects Dye Penetrant Test " 100% There shall be no FD'S Report - P R -
significant indications
ii Impeller --- " --- --- " --- " 100% --- " --- --- " --- - P R -
iii Rotor Assembly Welding Defects --- " --- " 100% --- " --- --- " --- - P R -
C I Stator Assembly Electrical Parameters Winding Resistance " 100% As per std. Procedure FD'S Report - P R -
( IS 325 )
Insulation Test " 100% --- " --- --- " --- - P R -
High Voltage Test " 100% --- " --- --- " --- - P R -
Load Test " 100% --- " --- --- " --- - P R -
D I Rotor Assembly Residual Unbalance Dynamic Balancing " 100% ISO 1940-1986 G 6.3 --- " --- - P R/W -