Número de medio -RENR3823-15 Fecha de publicación -01/02/2013 Fecha de actualización -25/02/2013

i02065106

Governor Actuator - Calibrate


SMCS - 1716-524

S/N - AKH1-UP

S/N - ALF1-UP

S/N - ALX1-UP

S/N - AMC1-UP

S/N - ANB1-UP

S/N - APA1-UP

S/N - AXK1-UP

S/N - BBL1-UP

S/N - BCN1-UP

S/N - BDE1-UP

S/N - BEA1-UP

S/N - BER1-UP

S/N - BFE1-UP

S/N - BFK1-UP

S/N - BGR1-UP

S/N - BKJ1-UP

S/N - BKM1-UP

S/N - BLP1-UP

S/N - CLM1-UP

S/N - CLZ1-UP
S/N - DAA1-UP

S/N - DBG1-UP

S/N - EGL1-UP

S/N - EMR1-UP

S/N - FED1-UP

S/N - GLA1-UP

S/N - HEK1-UP

S/N - JTG1-UP

S/N - MAB1-UP

S/N - MAC1-UP

S/N - MAR1-UP

S/N - PAB1-UP

S/N - PAC1-UP

Note: The 325C, M325C MH, and 330C series does not have a governor actuator.

This function can memorize the rotation angle of the governor actuator and the no-load engine speed. This information is
saved into the controller after the accelerator cable of the governor actuator has been replaced, installed and/or adjusted.
The controller will use the information that was saved in order to determine the target position for the actuation of the
governor actuator.

Note: Ensure that the calibration procedure for the governor actuator is performed when the governor actuator, the
accelerator cable or the controller has been replaced or installed. The temperature of the hydraulic oil should be 50 °C
(122 °F) prior to the calibration.

Illustration 1 g00777652

The above illustration is an example of the display for the 312C. All of the other displays are identical with the sales model on the fourth
line.
1. Enter the service mode.

Illustration 2 g00825978

2. Highlight the second line of the display and use the direction for direction to scroll through the display. Scroll
through the display until the display shows "CALIBRATION".

Illustration 3 g00790593

3. Highlight the third line by using the keys for direction. The name of the device will be shown on the third line.
Scroll downward until "STANDBY" is highlighted. Press the "OK" key in order to start the calibration procedure.
"GOVERNOR-EXE" is displayed on the third line when the governor actuator is calibrated. Press the "OK" key
after confirming the display of "GOVERNOR-EXE".
Illustration 4 g00790592

4. The above illustration shows a display that is temporarily shown when the governor actuator is moved to the initial
position. Press the "OK" key again when the display shows "SP". The calibration procedure has started.

Illustration 5 g00790597

5. The numerical number that is being displayed in the fourth line will change during the calibration. This number is
related to the process of the calibration. See the following table 1.

Table 1
Content For The Process
Display Process
STANDBY Prior to calibration
1 Transfer of the initial position of the governor actuator
SP The initial transfer of the information about the position has been completed.
3 High idle search
4 Positioning of the high idle
5 Data collection of the intermediate points (9-2) down
6 Low idle search
7 Data acquisition of intermediate points (2-9) up
8 Confirmation of the high idle
9 Confirmation of the setting for the speed dial (down)
10 Confirmation of the setting for the speed dial (up)
11 End processing

Illustration 6 g00790598

6. The above illustration is shown after the governor actuator has completed the calibration.

Warnings
If the fourth line of the display shows any of the following warnings a failure is present. See the following table 2 for a
detailed description of the warning displays.

Table 2
Warning Codes
Display Warning Corrective Action
Wire nut is installed too loose
Wire Pitch X (X is
by X pitch. X can be a positive Tighten the accelerator cable by the displayed pitch. Perform
a number from 0
or negative number. Turn the calibration again.
to 9)
clockwise.
Wire nut is installed too tight
Wire Pitch X (X is
by X pitch. X can be a positive Loosen the accelerator cable by the displayed pitch. Perform
number from -9 to
or negative number. Turn the calibration again.
0)
clockwise.
WARNING 01 Insufficient high idle High idle is less than the specified value due to malfunction of
the engine, incorrect installation of the governor cable, poor
fuel, etc. After the engine has been inspected for a malfunction,
reinstall the cable and perform the calibration again.
Incorrect installation of cable
WARNING 02 Reinstall the cable and perform the calibration again.

Low idle is more than the value specified due to a malfunction


in the engine, an incorrectly installed governor cable, etc. After
WARNING 03 Excessive low idle
the engine has been inspected, reinstall the cable and perform
the calibration again.
Ensure that the cable is adjusted correctly. Reinstall the cable
WARNING 04 Excessive hysteresis
and perform the calibration again.
High idle is unstable due to a malfunction in the engine, an
incorrect installation of the governor cable, etc. After the
WARNING 05 Unstable high idle
engine has been inspected, reinstall the cable and perform the
calibration again.
The speed for the dial setting is unstable due to a malfunction
in the engine, an incorrectly installed cable, etc. After the
WARNING 06 Unstable dial speed
engine has been inspected, reinstall the cable and perform the
calibration again.

Errors
If the fourth line of the display shows any of the following errors a failure is present. See the following table for a
detailed description of the error displays.

Table 3
Error Codes For The Governor Actuator
Error
Description Of The Error Corrective Action
Code
ERROR Improper calibration of another device Stop the calibration of the other device. Perform one
01 calibration at a time.
ERROR Improper calibration of another Stop the calibration of the other device. Perform one
02 module calibration at a time.
ERROR Perform the troubleshooting procedure that will confirm the
Failure of the interlock signal
03 signal that communicates with the monitor.
ERROR
Abnormal speed sensor Troubleshoot the confirmation of the speed sensor.
11
ERROR Perform the calibration again. Try to prevent the engine from
Engine stop
12 stopping.
ERROR Reset all operational levers to the neutral position. Perform the
Load available
13 calibration again.
You need to allow the complete cooldown. Clear the
ERROR Overheating of the coolant or the
overheating condition. Perform the calibration procedure again.
14 hydraulic oil during the calibration

ERROR Pressure decrease in the engine oil Clear the abnormal occurrence and perform the calibration
15 Check for clogged air cleaner again.
ERROR
Excessive governor movement time Troubleshoot the confirmation of the governor actuator.
16
Perform the following procedure when the data for the calibration of the governor actuator is cleared.

Illustration 7 g00790593

1. Highlight the third line by using the arrow keys.

Illustration 8 g00790641

2. Press the "menu" key. The area that is highlighted will scroll to the right.
Illustration 9 g00790642

3. Change the display of the third line in order to show "CLEAR" by using the arrow keys. See the above illustration.

Illustration 10 g00790651

4. Highlight the fourth line by using the directional keys. Press the "OK" key when the fourth line is highlighted.
Illustration 11 g00790652

5. Press the "OK" key when the display shows "CLEAR?".

Illustration 12 g00790653

6. The data for the calibration has been cleared when the fourth line of the display shows "CLEARED".