Вы находитесь на странице: 1из 2

rƒsco so2000dt

2-in-1 Handler with two Temperature Chambers

Comparison SO2000 / SO2000DT

3
Key Advantages
Reduced costs • Reduced floor space
Reduced QIP (quality improvement program)
Reduced WIP (work in progress)
Reduced cycle time

Producti vi ty & Flexibility K e y Fe at u re s


n Conversion kits for all SO and QFN devices n 2 temperatures in 1 Handler
down to 1.4 mm, including QFN thin (ambient and hot/cold)
n Large variety of contactors: Kelvin, RF, Pogo, n Temperature range -60°C up to +175°C
ECT, Johnstech, Yamaichi, C-Type n Controlled ambient temperature
n Multiple input and output modules: n Device ID tracking
Tube, bowl (SOT and QFN), metal magazine,
bulk, tape and reel n Extended quality features
n Smallest device size
n 2 tracks, quad contact site (2+2)
n Standard belly bar and RPTB plungers
n Index time down to 450 ms
n Throughput up to 16,000 UPH
n Small footprint
rƒsco SO2000dt
2-in-1 Handler with two Temperature Chambers

Specifications
Throughput n The SO2000DT Dual Temperature Handler provides
Up to 16,000 ICs/hour two temperature chambers in one system, one for
Index Time ambient and one for cold, hot and extended hot
Down to 0.45 s
temperature —devices can be handled separately in
Conversion Kits
two different temperature modes.
For all SO and QFN devices down to 1.4 mm,
including QFN thin n The SO2000DT has two Dual Plungers — one at
Thermal ambient test site (contact site and * ) and at
Ambient/hot/tri-temp -60°C to +175°C
temperature test site (contact site and * ) for
2 temperature chambers for ambient and hot/cold
different contactors, including “Real Plunge-to-Board”
Contactors
Kelvin, RF, Pogo, ECT, Johnstech, Yamaichi, C-Type
(depends on contactor/device type combination).
Input / Output Modules n The Temperature range can be selected equivalent
Tube, bowl (SOT and QFN), metal magazine, bulk, to the existing SO2000 Handler (-60°C to +160°C,
tape and reel
optional +175°C).
Inspection
Rasco Vision System: Mark/3D-lead/intape n All other modules, contactors and input and output
MEMS configurations are equivalent to the SO2000 standard
Applications for magnetic, optical, pressure and
system.
acoustic sensors

Process Flow
n Standard SO2000 loaders carry devices to the handler.
Singulated device drops from loader to upper precontact
site.
n The devices are tested at ambient temperature and as-
sign a unit identification number that is transferred to the
tester via the GPIB interface. The device drops into upper
CS (ambient area) and is plunged for ambient test.
n The devices that have passed the ambient test site are
released into the temperature chamber and soaked until
they have reached the desired set point. The device then
drops into the soak track.
SO2000DT schematic process flow
n After the specified soak time has elapsed, devices are
tested at the temperature test site. The handler sends the
device’s unit ID value to the tester via the GPIB interface.
The device then drops into lower Pre-CS (buffer with dou-
ble drop detection). Device is plunged for temperature test.
n The devices are sorted to the prime bin, off bin or reject
bin according to the tester results.

Device Tracking
n Device IDs will be generated at both upper contact sites
(odd IDs for leftside, even IDs for rightside).
n While device is dropping, device ID and bin are both
shifted together to the next handling section.
Throughput example for SOT23W device; soak time 60 s

* See cover SO2000 / SO2000DT comparison graphic for contact site location.

12367 Crosthwaite Circle, Poway, CA 92064-6817


Tel. 858.848.8000 Email: info@cohu.com

For global sales locations and support, please visit


Specifications subject to change without notice.
For detailed performance specifications, please contact Cohu.
www.cohu.com
8336834 Rev B 0416

Вам также может понравиться