Вы находитесь на странице: 1из 7

kbe

AIR MOVEMENT PRODUCTS


TEL: 961-1-898268, FAX: 961-1-887113, Email: kbe@kbelebanon.com

Linear Bar Diffusers


Model LBD - Series 1500 &1600

Application :Kbe extruded aluminum linear bar


diffusers meet architectural demands for a
versatile supply and return air duct that blends
with an accents linear design concepts.

Material : Kbe Linear Bar diffusers are made of 1/ 8" Bars, 1/ 8" Bars,
high grade aluminum extrusions for maximum 1 / 4 " Spacing 1/ 2" Spacing
strength and corrosion resistance.

Construction : Bars are of natural anodized DIMEN SION S


extruded aluminum are interlocked into heavy
gauge cross bars to produce straight rigid core Size W idth Length (cm)
sections.
Available in two angles of deflection 0° and 15° 3" 360
placed on 1/4" and 1/2" centers. 4" 340
Linear bar diffuser frames are made of extruded
anodized aluminum border of 13/8" width. 5" 340
Ideal for sidewall, sill or ceiling installation. 6" 320
Maximum lenght of a one piece unit is 10 ft., if
continuous lenght is desired sections are butted 7" 300
together by use of alignment bars or pins a 8" 300
continuous diffuser of desired length.
Available opposed blade damper, O.B.D. may be 9" 270
operated with screwdriver through the grille face. 10" 270
Continuous straight line styling features a trim
attractive design that provides exacting 12" 270
performance.
Diffusers can be used on the supply or return Spacing Bars Deflection
positions of heating, cooling or ventilating system.
1/ 4" 1/ 8" 0°
Accessories and options: Available opposed 1/ 4" 1/ 8" 15°
blade dampers including metered corners.
1/ 2" 1/ 8" 0°
Available widths: 1/ 2" 1/ 8" 15°
11/2", 2", 21/2", 3", 31/2", 4", 5", 6", 7" and 8".
kbe
AIR MOVEMENT PRODUCTS
TEL: 961-1-898268, FAX: 961-1-887113, Email: kbe@kbelebanon.com

OPPOSED DAMPER CORE W ITH BORDER

DIMEN SION AL TABLES

0° 1 / 8 " Bars, 1 / 4 " Spacing 15° 1 / 8 " Bars, 1 / 4 " Spacing

D + 115/16" D + 115/16"

D - 3/4" 13/8" D - 3/4" 13/8"


3
/4" 3
/4 "

7
/8 " 7
/8"

Duct Size D Duct Size D

0° 1 / 8 " Bars, 1 / 2 " Spacing 15° 1 / 8 " Bars, 1 / 2 " Spacing

D + 115/16" D + 115/16"

D - 3/4" 13/8" D - 3/4" 13/8"


3
/4" 3
/4 "

7
/8 " 7
/8"

Duct Size D Duct Size D

DIFFUSER BAR SPACIN G AN D DEFLECTION S

1/4" 1/8" 1/4" 1/8" 1/2" 1/8" 1/2" 1/8"

5/8" 5/8" 5/8" 5/8"


3/32" 3/32" 3/32" 3/32"

1/ 8"Bar, Spaced on 1 / 4 " 1/ 8" Bar, Spaced on 1 / 4 " 1/ 8"Bar, Spaced on 1 / 2 " 1/ 8"Bar, Spaced on 1 / 2 "
C enters. 0 ° Deflection C enters. 1 5 ° Deflection C enters. 0 ° Deflection C enters. 1 5 ° Deflection
kbe
AIR MOVEMENT PRODUCTS
TEL: 961-1-898268, FAX: 961-1-887113, Email: kbe@kbelebanon.com

FASTEN IN GS WIDTHS DIMENSIONS


Model 1600 & 1602 Model 1601 & 1603 Model 1500 & 1502 Model 1501 & 1503
Width 1/2" Spacing - 3cm Frame 1/2" Spacing - 2cm Frame 1/4" Spacing - 3cm Frame 1/4" Spacing - 2cm Frame
W ood Frame Face Size Neck Size Face Size Neck Size Face Size Neck Size Face Size Neck Size
Border 1 1/ 2" 8 . 5 cm 3 . 2 cm 6 . 1 cm 3 . 2 cm 8 . 5 cm 3 . 2 cm 6 . 1 cm 3 . 2 cm
2" 9 . 8 cm 4 . 6 cm 7 . 3 cm 4 . 6 cm 9 . 8 cm 4 . 6 cm 7 . 3 cm 4 . 6 cm
2 1/ 2" 1 1 . 2 cm 6 cm 8 . 8 cm 6 cm 1 1 . 2 cm 6 cm 8 . 8 cm 6 cm
3" 1 2 . 5 cm 7 . 3 cm 1 0 cm 7 . 3 cm 1 2 . 5 cm 7 . 3 cm 1 0 cm 7 . 3 cm
3 1/ 2" 1 3 . 5 cm 8 . 3 cm 1 1 . 1 cm 8 . 3 cm 1 3 . 5 cm 8 . 3 cm 1 1 . 1 cm 8 . 3 cm
4" 1 4 . 9 cm 9 . 8 cm 1 2 . 6 cm 9 . 8 cm 1 4 . 9 cm 9 . 8 cm 1 2 . 6 cm 9 . 8 cm
5" 1 7 . 4 cm 1 2 . 3 cm 1 5 cm 1 2 . 3 cm 1 7 . 4 cm 1 2 . 3 cm 1 5 cm 1 2 . 3 cm
Aluminum Border 6" 1 9 . 9 cm 1 4 . 8 cm 1 7 . 6 cm 1 4 . 8 cm 1 9 . 9 cm 1 4 . 8 cm 1 7 . 6 cm 1 4 . 8 cm
7" 2 2 . 5 cm 1 7 . 3 cm 2 0 . 2 cm 1 7 . 3 cm 2 2 . 5 cm 1 7 . 3 cm 2 0 . 2 cm 1 7 . 3 cm
8" 2 5 cm 1 9 . 8 cm 2 2 . 7 cm 1 9 . 8 cm 2 5 cm 1 9 . 8 cm 2 2 . 7 cm 1 9 . 8 cm

Corner Dimensions for Ceiling Mounting 90° Mitered Corner section Special mitered corner.Available
available for ceiling, floor, sill or for ceiling, floor, sill or sidewall
Width OUTER Width OUTER sidewall installations. Horizontal installations.
(Y) LENGH (X) (Y) LENGH (X)
flat metered corner includes an Horizontal flat mitered corner
11/2" 33.81 cm 6" 45.24 cm angle of 90° ,available in 0° and includes an angle greater than 90°
2" 35.08 cm 61/2" 46.51 cm 15° deflection. Corner section and less than 180° and available in
21/2" 36.35 cm 7" 47.78 cm contains two feet of straight grille 0° and 15° deflections. Horizontal
3" 37.62 cm 71/2" 49.05 cm one foot on each side. The corner corner sections are not available
31/2" 38.89 cm 8" 50.32 cm section is normally inactive for angles of less than 90°. The
4" 40.16 cm 9" 52.86 cm sections of one piece and are not corner section contains two feet of
41/2" 41.43 cm 10" 55.4 cm supplied with dampers. straight grille one foot on each
5" 42.7 cm 12" 60.48 cm side. The corner section
51/2" 43.97 cm is not supplied with dampers.
*Duct Width Equals Listed Width

ALIGN MEN T STRIPS 90° MITERED CORN ER SPECIAL MITERED CORN ER

Variable
90°

" X"
Overall
lenght " Y"

90° Mitered Corner " X" 135° Shown


Overall Lenght

CORNERS DIMENSIONS FOR WALL


VERTICAL MILTERD CORN ERS MOUNTING FOR ALL SIZES 30 CM

Vertical outside and inside wall mitered corner section


is designed for sidewall installation at junction of two
side of walls. The mitered corner section include an
angle of 90° and available in 0° and 15° deflection.
The mitered corner section are not available for an
angle other than 90°. Corner section contains two feet
of straight grille one foot on each side. The corner
30
cm 30
cm section is normally inactive sections of one piece and
are not supplied with dampers.
Inside W all Outside W all
kbe
AIR MOVEMENT PRODUCTS
TEL: 961-1-898268, FAX: 961-1-887113, Email: kbe@kbelebanon.com

Linear Bar Diffusers Side Wall Mount


Model: LBD 1500 & Model: LBD 1501
1/4 " Bar Spacing - 0° Deflection

PERFORMANCE DATA

N om . A rea P ER FO R M A N CE DA TA
W id th Fa cto r CFM / FT 25 38 50 63 76 89 101 114 127 152 176 203

S ta tic 0.062 0.140 0.250 0.388 0.555

11/ 2 .043 Th r ow 16-11-8 18-13-9 21-15-11 24-17-13 26-19-14

NC 15 20 25 33 42

S ta tic 0.038 0.067 0.105 0.150 0.208 0.267 0.338 0.420

2 .060 Th r ow 16-11-6 20-13-9 22-15-11 24-18-13 27-20-16 29-22-18 31-24-20 33-26-21

NC < 15 17 20 25 32 35 38 42

S ta tic 0.029 0.045 0.064 0.088 0.114 0.144 0.180 0.257

21/ 2 .088 Th r ow 19-11-7 21-15-10 23-18-12 25-20-14 27-22-17 30-24-19 32-25-21 34-27-23

NC < 15 18 22 25 29 33 37 42

S ta tic 0.027 0.040 0.055 0.071 0.089 0.110 0.158 0.215

3 .115 Th r ow 20-14-9 21-17-12 23-19-14 25-20-16 28-23-18 31-25-20 34-27-22 37-29-24

NC < 15 16 21 25 28 32 38 42

S ta tic 0.025 0.034 0.044 0.055 0.068 0.099 0.135

31/ 2 .140 Th r ow 20-15-10 22-17-13 24-19-15 27-22-17 30-24-19 33-26-21 36-28-23

NC 15 19 23 26 28 35 40

S ta tic 0.019 0.026 0.033 0.042 0.052 0.075 0.102 0.134

4 .168 Th r ow 19-14-9 21-16-12 23-17-14 26-20-16 29-22-18 32-25-20 35-28-22 38-30-24

NC < 15 17 21 23 26 32 37 41

S ta tic 0.020 0.027 0.034 0.042 0.060 0.082 0.106

5 .223 Th r ow 20-15-10 22-17-13 25-19-16 28-21-18 31-24-20 34-26-21 37-28-22

NC < 15 18 20 23 29 35 40

S ta tic 0.024 0.031 0.038 0.055 0.075 0.098

6 .240 Th r ow 20-15-11 23-18-13 26-20-15 29-23-17 32-25-18 35-27-20

NC < 15 17 21 27 33 39

Notes: Static Pressure is in "H2O, Air volume is in CFM


NC values were determined by subtracting 10 dB from the sound power level for room absorption.
Throw data is presented for terminal velocities of 50-100-150 ft./min.
Laboratory tests were performed on the 1/2"Bar Spacing 0 Deflection Diffusers unit in accordance
with ASHRAE 70-1991 "Method of Testing for Rating the Performance of Air "Outlets and Inlets".

Equipment Ratings C ertified by ¨


ETL Testing Laboratories, Inc. N . Y. - Intertek Testing Services
AIR MOVEMENT PRODUCTS
TEL: 961-1-898268, FAX: 961-1-887113, Email: kbe@kbelebanon.com

Linear Bar Diffusers Side Wall Mount


Model: LBD 1502 & Model: LBD 1503
1/4 " Bar Spacing - 15° Deflection

PERFORMANCE DATA
Nom. Area
Width Factor CFM/FT 25 38 50 63 76 89 101 114 127 152 176 203

Static 0.075 0.170 0.300 0.470 0.680


11/2 .025 Throw 15-10-8 17-13-10 20-15-12 22-17-13 24-18-14
NC 16 22 29 36 45

Static 0.019 0.043 0.075 0.118 0.170 0.230 0.300 0.381


2 .053 Throw 13-7-5 15-10-7 18-11-8 20-13-10 21-15-12 23-16-13 25-18-14 26-19-15
NC < 15 < 15 17 23 31 35 39 42

Static 0.019 0.034 0.053 0.075 0.103 0.135 0.170 0.210 0.305
21/2 .079 Throw 14-8-5 16-9-6 18-11-8 19-13-10 21-14-11 23-16-11 24-17-11 26-18-12 30-20-14
NC < 15 15 19 25 29 33 36 40 44

Static 0.019 0.030 0.043 0.058 0.076 0.095 0.120 0.170 0.230
3 .104 Throw 15-7-4 16-9-6 17-11-7 19-12-8 21-13-9 23-15-10 25-16-12 29-19-14 33-24-17
NC < 15 15 20 24 27 30 34 39 43

Static 0.019 0.027 0.037 0.048 0.061 0.075 0.110 0.150 0.194
31/2 .132 Throw 16-9-5 17-11-7 18-12-8 20-13-9 22-15-10 24-17-11 27-20-13 31-24-17 34-28-18
NC < 15 18 21 25 28 32 37 41 45

Static 0.022 0.030 0.038 0.049 0.060 0.086 0.119 0.155


4 .162 Throw 17-11-7 18-11-7 20-12-8 21-14-9 22-16-11 25-20-13 30-24-16 34-27-18
NC < 15 19 23 27 31 36 39 43

Static 0.024 0.031 0.039 0.049 0.070 0.095 0.123


5 .219 Throw 18-11-6 19-11-7 20-14-9 21-16-11 23-19-13 29-23-16 33-27-18
NC 15 20 24 29 34 40 43

Static 0.025 0.032 0.040 0.057 0.078 0.102


6 .275 Throw 19-10-6 20-13-9 21-16-10 22-18-12 28-22-15 33-26-17
NC 16 21 25 32 37 42

Notes: Static Pressure is in "H2O, Air volume is in CFM


NC values were determined by subtracting 10 dB from the sound power level for room absorption.
Throw data is presented for terminal velocities of 50-100-150 ft./min.
Laboratory tests were performed on the 1/2"Bar Spacing 0 Deflection Diffusers unit in accordance
with ASHRAE 70-1991 "Method of Testing for Rating the Performance of Air "Outlets and Inlets".

Equipment Ratings Certified by ¨


ETL Testing Laboratories, Inc. N.Y. - Intertek Testing Services
kbe
AIR MOVEMENT PRODUCTS
TEL: 961-1-898268, FAX: 961-1-887113, Email: kbe@kbelebanon.com

Linear Bar Diffusers Side Wall Mount


Model: LBD 1600 & Model: LBD 1601
1/2 " Bar Spacing - 0° Deflection

PERFORMANCE DATA
N om . A rea P ER FO R M A N CE DA TA
W id th Fa cto r CFM / FT 25 38 50 63 76 89 101 114 127 152 176 203

S ta tic 0.051 0.114 0.202 0.316 0.460

11/ 2 .048 Th r ow 17-10-7 19-12-8 22-14-10 24-17-12 26-19-14

NC 16 21 26 31 38

S ta tic 0.036 0.064 0.100 0.147 0.200 0.256 0.323 0.400

2 .075 Th r ow 16-9-5 20-13-8 22-15-10 24-17-12 25-19-14 27-21-16 28-23-18 30-24-19

NC < 15 < 15 20 25 30 33 36 40

S ta tic 0.031 0.048 0.070 0.095 0.124 0.157 0.196 0.280

21/ 2 .103 Th r ow 19-12-8 20-14-9 21-16-11 23-17-13 24-19-14 26-20-16 28-22-17 31-24-19

NC < 15 17 20 24 28 31 35 40

S ta tic 0.027 0.039 0.053 0.070 0.087 0.109 0.156 0.210 0.285

3 .130 Th r ow 18-14-9 19-15-11 20-15-12 22-16-13 24-18-14 26-20-16 29-22-17 32-25-18 34-27-20

NC < 15 16 20 23 26 29 35 39 43

S ta tic 0.026 0.035 0.047 0.059 0.073 0.104 0.142 0.185

31/ 2 .155 Th r ow 19-14-9 21-15-10 22-15-11 24-17-12 26-19-14 28-21-16 30-24-18 33-27-19

NC 15 17 20 23 27 33 37 41

S ta tic 0.018 0.025 0.032 0.041 0.050 0.072 0.100 0.130

4 .183 Th r ow 19-13-7 20-14-9 22-15-10 23-16-12 25-18-14 27-21-16 29-23-17 32-26-18

NC < 15 15 18 21 25 31 35 39

S ta tic 0.015 0.020 0.025 0.031 0.045 0.062 0.081

5 .238 Th r ow 19-13-8 21-14-9 22-15-11 24-17-13 26-20-15 29-22-16 32-25-17

NC < 15 16 19 22 27 33 38

S ta tic 0.014 0.017 0.021 0.031 0.042 0.055

6 .293 Th r ow 20-13-8 22-14-10 23-16-12 25-19-14 28-22-15 31-25-16

NC < 15 15 18 24 30 36

Static 0.011 0.015 0.022 0.029


8 .403 Throw 20-13-9 23-17-12 26-21-14 30-24-13
NC <15 17 23 26

Notes: Static Pressure is in "H2O, Air volume is in CFM


NC values were determined by subtracting 10 dB from the sound power level for room absorption.
Throw data is presented for terminal velocities of 50-100-150 ft./min.
Laboratory tests were performed on the 1/2"Bar Spacing 0 Deflection Diffusers unit in accordance
with ASHRAE 70-1991 "Method of Testing for Rating the Performance of Air "Outlets and Inlets".

Equipment Ratings C ertified by ¨


ETL Testing Laboratories, Inc. N . Y. - Intertek Testing Services
kbe
AIR MOVEMENT PRODUCTS
TEL: 961-1-898268, FAX: 961-1-887113, Email: kbe@kbelebanon.com

Linear Bar Diffusers Side Wall Mount


Model: LBD 1602 & Model: LBD 1603
1/2 " Bar Spacing - 15° Deflection

PERFORMANCE DATA
Nom. Area PERFORMANCE DATA
Width Factor CFM/FT 25 38 50 63 76 89 101 114 127 152 176 203 240

Static 0.050 0.112 0.198 0.310 0.450 0.610

11/2 .040 Throw 17-10-7 19-12-8 21-14-10 23-16-12 25-19-14 28-22-17

NC < 15 16 21 27 33 41

Static 0.044 0.064 0.098 0.140 0.192 0.313 0.394 0.486

2 .068 Throw 16-10-7 19-13-9 21-15-11 23-17-13 25-19-15 27-21-16 29-23-18 31-24-20

NC < 15 < 15 21 27 32 35 38 42

Static 0.031 0.048 0.070 0.095 0.124 0.157 0.194 0.279

21/2 .095 Throw 16-10-7 18-12-8 20-13-10 22-16-12 24-18-13 26-20-15 29-22-17 31-24-20

NC < 15 18 22 27 29 33 37 42

Static 0.028 0.041 0.056 0.073 0.091 0.115 0.164 0.222

3 .123 Throw 16-9-6 18-10-7 20-13-9 22-15-10 24-17-12 27-20-15 29-22-17 31-24-20

NC < 15 17 22 24 28 32 38 42

Static 0.019 0.027 0.037 0.048 0.061 0.075 0.108 0.148 0.192

31/2 .150 Throw 16-9-7 18-11-8 20-14-10 22-15-11 24-17-12 26-19-15 29-21-17 32-24-20 35-27-21

NC < 15 16 20 21 26 30 36 40 44

Static 0.018 0.026 0.032 0.044 0.052 0.078 0.106 0.138

4 .175 Throw 18-13-9 20-15-10 21-16-11 23-17-13 26-19-15 29-21-17 32-24-19 35-28-21

NC 15 19 22 25 29 35 39 42

Static 0.016 0.021 0.026 0.032 0.046 0.063 0.082

5 .230 Throw 19-14-10 20-15-10 22-16-12 25-18-14 28-20-16 31-23-18 34-27-20

NC 18 21 24 28 34 38 41

Static 0.014 0.018 0.023 0.032 0.044 0.058 0.081


6 .288 Throw 19-15-10 21-16-11 23-17-13 27-19-14 30-23-17 34-27-20 37-30-22

NC 19 22 27 33 36 40 43

Static 0.01 0.013 0.019 0.025 0.033 0.047

8 .401 Throw 19-15-9 21-15-11 25-17-12 27-20-14 30-23-17 34-27-20

NC 15 18 22 26 31 35

Notes: Static Pressure is in "H2O, Air volume is in CFM


NC values were determined by subtracting 10 dB from the sound power level for room absorption.
Throw data is presented for terminal velocities of 50-100-150 ft./min.
Laboratory tests were performed on the 1/2"Bar Spacing 0 Deflection Diffusers unit in accordance
with ASHRAE 70-1991 "Method of Testing for Rating the Performance of Air "Outlets and Inlets".

Equipment Ratings Certified by ¨


ETL Testing Laboratories, Inc. N.Y. - Intertek Testing Services

Вам также может понравиться