CPU Engineering Station Module Order number Interface Manual Bus System Specific Feature
System
S7-300/S7-400 CPU STEP 7 V5.5 ET 200SP CM PtP 6ES7137-6AA00-0BA0 RS232 und RS422/RS485 69124220 PN, DP HSP0240 necessary
ET 200MP CM PtP RS232 BA 6ES7540-1AD00-0AA0 RS232 69124220 PN, DP PN: GSD necessary
CM PtP RS232 HF 6ES7540-1AB00-0AA0 RS232 DP: GSD necessary, Parametrization via FBs
CM PtP RS422/485 BA 6ES7541-1AD00-0AB0 RS422/RS485
CM PtP RS422/485 HF 6ES7541-1AB00-0AB0 RS422/RS485
TIA-Portal ET 200SP CM PtP 6ES7137-6AA00-0BA0 RS232 und RS422/RS485 59057093 (analogous use) PN, DP Input parameter "Port" of the FBs is the input
ET 200MP CM PtP RS232 BA 6ES7540-1AD00-0AA0 RS232 address
CM PtP RS232 HF 6ES7540-1AB00-0AA0 RS232
CM PtP RS422/485 BA 6ES7541-1AD00-0AB0 RS422/RS485
CM PtP RS422/485 HF 6ES7541-1AB00-0AB0 RS422/RS485
S7-1500 CPU TIA-Portal S7-1500 CM PtP RS232 BA 6ES7540-1AD00-0AA0 RS232 59057093 zentral
CM PtP RS232 HF 6ES7540-1AB00-0AA0 RS232
CM PtP RS422/485 BA 6ES7541-1AD00-0AB0 RS422/RS485
CM PtP RS422/485 HF 6ES7541-1AB00-0AB0 RS422/RS485
ET 200MP CM PtP RS232 BA 6ES7540-1AD00-0AA0 RS232 59057093 PN, DP
CM PtP RS232 HF 6ES7540-1AB00-0AA0 RS232
CM PtP RS422/485 BA 6ES7541-1AD00-0AB0 RS422/RS485
CM PtP RS422/485 HF 6ES7541-1AB00-0AB0 RS422/RS485
ET 200SP CM PtP 6ES7137-6AA00-0BA0 RS232 und RS422/RS485 59057093 PN, DP, central For ET 200SP PC and central installation
FW V1.0.2 is necessary
S7-1200 CPU TIA-Portal ET 200MP CM PtP RS232 BA 6ES7540-1AD00-0AA0 RS232 59057093 PN, DP
CM PtP RS232 HF 6ES7540-1AB00-0AA0 RS232
CM PtP RS422/485 BA 6ES7541-1AD00-0AB0 RS422/RS485
CM PtP RS422/485 HF 6ES7541-1AB00-0AB0 RS422/RS485
ET 200SP CM PtP 6ES7137-6AA00-0BA0 RS232 und RS422/RS485 59057093 PN, DP You need S7-1200 with firmware V4.1 and the
blocks of the library for S7-1200 ≥ V4.1 to use the
ET 200SP CM PtP on S7-1200.
S7-1200 CM 1241 RS232 6ES7241-1AH32-0XB0 RS232 107623221 central If you use the CM 1241 on a S7-1200 V4.1, you
need the CM 1241 with firmware V2.1 and the
blocks of the library for S7-1200 ≥ V4.1.
CM 1241 RS422/485 6ES7241-1CH32-0XB0 RS422/RS485 107623221 central
CB 1241 RS485 6ES7241-1CH30-1XB0 RS485 107623221 central
External CPU GSDML ET 200SP CM PtP 6ES7137-6AA00-0BA0 RS232 und RS422/RS485 59062563 PN FB created by user according to manual
External CPU GSD ET 200SP CM PtP 6ES7137-6AA00-0BA0 RS232 und RS422/RS485 59062563 DP FB created by user according to manual
External CPU GSDML ET 200MP CM PtP RS232 BA 6ES7540-1AD00-0AA0 RS232 59062563 PN FB created by user according to manual
CM PtP RS232 HF 6ES7540-1AB00-0AA0 RS232
CM PtP RS422/485 BA 6ES7541-1AD00-0AB0 RS422/RS485
CM PtP RS422/485 HF 6ES7541-1AB00-0AB0 RS422/RS485
External CPU GSD ET 200MP CM PtP RS232 BA 6ES7540-1AD00-0AA0 RS232 59062563 DP FB created by user according to manual
CM PtP RS232 HF 6ES7540-1AB00-0AA0 RS232
CM PtP RS422/485 BA 6ES7541-1AD00-0AB0 RS422/RS485
CM PtP RS422/485 HF 6ES7541-1AB00-0AB0 RS422/RS485
Note
1. For S7-1200 CPU with firmware V4.1 you can use the blocks of the library for S7-1200 ≥ V4.1.
2. You should always use the newest version of the function blocks.
for S7-1200 ≥ Firmware V4.1 in TIA-Portal included in "Instructions" task yes yes yes, via FB no
card under: yes
- Communication > Communication processor > PtP Communication no
- Communication > Communication processor > USS Communication yes
- Communication > Communication processor > MODBUS (RTU)
yes yes yes, via FB yes
for S7-1200 < Firmware V4.1 in TIA-Portal included in "Instructions" task
card under:
- Communication > Communication processor > Point-to-point
- Communication > Communication processor > USS yes no yes yes
- Communication > Communication processor > MODBUS