s How and in which S7 stations you can use the serial communication moduls?

Entry-ID: 109477693

CPU Engineering Station Module Order number Interface Manual Bus System Specific Feature
System
S7-300/S7-400 CPU STEP 7 V5.5 ET 200SP CM PtP 6ES7137-6AA00-0BA0 RS232 und RS422/RS485 69124220 PN, DP HSP0240 necessary
ET 200MP CM PtP RS232 BA 6ES7540-1AD00-0AA0 RS232 69124220 PN, DP PN: GSD necessary
CM PtP RS232 HF 6ES7540-1AB00-0AA0 RS232 DP: GSD necessary, Parametrization via FBs
CM PtP RS422/485 BA 6ES7541-1AD00-0AB0 RS422/RS485
CM PtP RS422/485 HF 6ES7541-1AB00-0AB0 RS422/RS485
TIA-Portal ET 200SP CM PtP 6ES7137-6AA00-0BA0 RS232 und RS422/RS485 59057093 (analogous use) PN, DP Input parameter "Port" of the FBs is the input
ET 200MP CM PtP RS232 BA 6ES7540-1AD00-0AA0 RS232 address
CM PtP RS232 HF 6ES7540-1AB00-0AA0 RS232
CM PtP RS422/485 BA 6ES7541-1AD00-0AB0 RS422/RS485
CM PtP RS422/485 HF 6ES7541-1AB00-0AB0 RS422/RS485
S7-1500 CPU TIA-Portal S7-1500 CM PtP RS232 BA 6ES7540-1AD00-0AA0 RS232 59057093 zentral
CM PtP RS232 HF 6ES7540-1AB00-0AA0 RS232
CM PtP RS422/485 BA 6ES7541-1AD00-0AB0 RS422/RS485
CM PtP RS422/485 HF 6ES7541-1AB00-0AB0 RS422/RS485
ET 200MP CM PtP RS232 BA 6ES7540-1AD00-0AA0 RS232 59057093 PN, DP
CM PtP RS232 HF 6ES7540-1AB00-0AA0 RS232
CM PtP RS422/485 BA 6ES7541-1AD00-0AB0 RS422/RS485
CM PtP RS422/485 HF 6ES7541-1AB00-0AB0 RS422/RS485
ET 200SP CM PtP 6ES7137-6AA00-0BA0 RS232 und RS422/RS485 59057093 PN, DP, central For ET 200SP PC and central installation
FW V1.0.2 is necessary
S7-1200 CPU TIA-Portal ET 200MP CM PtP RS232 BA 6ES7540-1AD00-0AA0 RS232 59057093 PN, DP
CM PtP RS232 HF 6ES7540-1AB00-0AA0 RS232
CM PtP RS422/485 BA 6ES7541-1AD00-0AB0 RS422/RS485
CM PtP RS422/485 HF 6ES7541-1AB00-0AB0 RS422/RS485
ET 200SP CM PtP 6ES7137-6AA00-0BA0 RS232 und RS422/RS485 59057093 PN, DP You need S7-1200 with firmware V4.1 and the
blocks of the library for S7-1200 ≥ V4.1 to use the
ET 200SP CM PtP on S7-1200.
S7-1200 CM 1241 RS232 6ES7241-1AH32-0XB0 RS232 107623221 central If you use the CM 1241 on a S7-1200 V4.1, you
need the CM 1241 with firmware V2.1 and the
blocks of the library for S7-1200 ≥ V4.1.
CM 1241 RS422/485 6ES7241-1CH32-0XB0 RS422/RS485 107623221 central
CB 1241 RS485 6ES7241-1CH30-1XB0 RS485 107623221 central
External CPU GSDML ET 200SP CM PtP 6ES7137-6AA00-0BA0 RS232 und RS422/RS485 59062563 PN FB created by user according to manual
External CPU GSD ET 200SP CM PtP 6ES7137-6AA00-0BA0 RS232 und RS422/RS485 59062563 DP FB created by user according to manual
External CPU GSDML ET 200MP CM PtP RS232 BA 6ES7540-1AD00-0AA0 RS232 59062563 PN FB created by user according to manual
CM PtP RS232 HF 6ES7540-1AB00-0AA0 RS232
CM PtP RS422/485 BA 6ES7541-1AD00-0AB0 RS422/RS485
CM PtP RS422/485 HF 6ES7541-1AB00-0AB0 RS422/RS485
External CPU GSD ET 200MP CM PtP RS232 BA 6ES7540-1AD00-0AA0 RS232 59062563 DP FB created by user according to manual
CM PtP RS232 HF 6ES7540-1AB00-0AA0 RS232
CM PtP RS422/485 BA 6ES7541-1AD00-0AB0 RS422/RS485
CM PtP RS422/485 HF 6ES7541-1AB00-0AB0 RS422/RS485

Note
1. For S7-1200 CPU with firmware V4.1 you can use the blocks of the library for S7-1200 ≥ V4.1.
2. You should always use the newest version of the function blocks.

This entry is from the Service&Pupport portal of Siemens AG,


Changedate: 08/09/2019 Siemens Industry Online Support. Page: 1/2
The general terms of use (http://www.siemens.com/terms_of_use) apply.
s How and in which S7 stations you can use the serial communication moduls? Entry-ID: 109477693

Block Library Freeport / 3964(R) USS Modbus RTU


ASCII
75226762 yes yes yes, via FB yes
75226762 yes yes yes, via FB no
yes
no
yes
in TIA-Portal included in "Instructions" task card under: yes yes yes, via FB yes
- Communication > Communication processor > PtP Communication yes yes yes, via FB no
- Communication > Communication processor > USS Communication yes
- Communication > Communication processor > MODBUS (RTU) no
yes
in TIA-Portal included in "Instructions" task card under: yes yes yes, via FB no
- Communication > Communication processor > PtP Communication yes
- Communication > Communication processor > USS Communication no
- Communication > Communication processor > MODBUS (RTU) yes
yes yes yes, via FB no
yes
no
yes
yes yes yes, via FB yes

for S7-1200 ≥ Firmware V4.1 in TIA-Portal included in "Instructions" task yes yes yes, via FB no
card under: yes
- Communication > Communication processor > PtP Communication no
- Communication > Communication processor > USS Communication yes
- Communication > Communication processor > MODBUS (RTU)
yes yes yes, via FB yes
for S7-1200 < Firmware V4.1 in TIA-Portal included in "Instructions" task
card under:
- Communication > Communication processor > Point-to-point
- Communication > Communication processor > USS yes no yes yes
- Communication > Communication processor > MODBUS

yes no yes yes


yes no yes yes
Created by user yes yes no no
Created by user yes yes no no
Created by user yes yes no no

Created by user yes yes no no