AP54.10-P-5451B High-voltage battery - Check capacity 19.3.

14

MODEL 242.890

Check
1 Connect diagnostic system
AD00.00-P-2000-04A
2.1 Check energy content using diagnostic system Sale & Care vehicles
The test is called up as follows in the
diagnostic system:
Quick test view Select BMS control unit
Select "Actual values" tab Select "Energy
content" actual value group
If the "Maximum energy content" actual value
is in the specified value range:

Disconnect diagnostic system.


If the actual value is not in the specified value
range:

Select "Tests" tab and run "Determination of


high-voltage battery energy content" test.
2.2 Check energy content using diagnostic system Except Sale & Care vehicles
The test is called up as follows in the
diagnostic system:
Quick test view Select BMS control unit
Select "Actual values" tab Select "Energy
content" actual value group
If the "Maximum energy content" actual value
is in the specified value range:

Disconnect diagnostic system.


If the actual value is not in the specified value
range:

Run "Determination of high-voltage battery


energy content" test subject to separate repair
order.