Вы находитесь на странице: 1из 7

Information for Your Safety

The equipment has reliable functional performance as its design, but you should
avoid man-made damages to it.
Please read this Manual carefully and keep it for later
reference.

DH2010A Don’t expose this equipment to rain or moisture.


Don’t put anything on the cable and prevent it form knotting up or unceasing.
Keep it out of reach.

E1/10Base-T Electrical connection and other equipment connectors should be


securely jointed, and please check them often.
Please keep the equipment clean and wipe it with a soft cotton cloth

Conversion if necessary.
Under following conditions, please cut off the power immediately and
contact with us.

Equipment 1. The equipment is wet;


2. The equipment is broken or the enclosure is cracked;
3. The equipment works abnormally or the properties change
completely;
4. The Equipment emits smoke or some unusual smell and noise.
Please don’t mend the equipment by yourself except there are
obvious instructions.

User's
manual
Cautions
Any part of this manual can’t be copied or transmitted as any form Catalogue
on network without written form permission of our company. The brand
ownerships that are mentioned in the manual are belonged to every I. Introduction to the System ...................................................... 1
brand owner. The company has the right of changing products II.Main Feature ........................................................................ 1
performance and this manual at any time without informing clients. III.Technical Parameter............................................................ 2
We don’t take any responsibility for invalidation of products or 3.1. 2048Kbit/s interface electricity feature........................ 2
damages caused by any form modification of products or this manual. 3.2. 10Base-T Interface................................................... 2
3.3. Power Supply Condition.......................................... 3
Our company supplies one-year free repair service and takes 3.4.Working Environment................................................ 3
responsible for maintenance a lifetime long for legal users. 3.5.Size ............................................................................ 3
During the warranty period, we take responsibility for changing the IV. Appearance............................................................................ 3
products that can’t be used because of quality problem, and the company V. On-0ff Switch Setup............................................................... 5
has the ownership of the reclaimed products. 5.1. Foundational On-off Switch Setup .............................. 5
VI.Interface Definition ............................................................ 6
6.1.75ΩE1 interface definition ........................................ 6
6.2.120ΩE1 interface definition ...................................... 6
6.3.Ether interface Definition .......................................... 7
VII.Plan Constructor................................................................ 8
VIII.Accessories ...................................................................... 8
IX. Warranty instruction ............................................................. 9
DH2010A E1/10Base-T Conversion Equipment DH2010A E1/10Base-T Conversion Equipment

z Having perfect functions of warning and conditional indication;


I. Introduction to the System z Suiting different power resource environment -48VDC/220VAC;

DH2010A E1/10Base-T Conversion Equipment is a high-tech and


III.Technical Parameter
qualified product that was invented by our company. It’s a kind of
conversion equipment that exchanges E1 interface into Ethernet
interface. The Ethernet interfaces can connect with computer network 3.1. 2048Kbit/s interface electricity
card or switching exchange, line concentrator and other equipments.
Ether interfaces as 10/100M adaptation mode, make good use of network feature
resources, optimizing network transmission, cutting down the user’s
cost. It’s ideal equipment for cheap bridging link condition and z Nominal speed velocity: 2048Kbit/s±50ppm;

it could be used as a local area network (LAN) stretcher. z Code pattern of Interface : HDB3
z Interface impedance: both 75Ω(unbalance) and 120Ω(balance);

This equipment supplies integrated facilities. Each machine z Digital interface electricity feature: matching ITU—TG.703

frame has 15 slot position, which all can be used for plug-in z Jitter transmission feature: matching ITU—TG.823

equipment card, including different cards, such as DH2000K(E1/V.35)、 z Input jitter capacity: matching ITU—TG.823

DH2010K(E1/10Base-T)and cards that can be plugged in optical transmitter z Output jitter: matching ITU—TG.823

and receiver, for example DH30K、DH30VK、DH30EK. All these equipment can z 2048Kbit/s digital interface physical electric feature matching

plug different cards synchronously. ITU-TG.703


z Type of interface: BNC——75Ω,RJ-45——120Ω;
II.Main Feature
z Using massive integrated chipset, and the circuit is simple,
3.2. 10Base-T Interface
stable and reliable;
z Nominal speed velocity: 10/100Mbit/s
z Supplying an E1 interface, resistance is 75Ω/120Ωas tunable type
z Regulation rules of interface: matching IEEE-802.3u standard
z E1 interface with BNC connector as 75Ω, and RJ-45 connector as
z Type of interface: RJ-45;
120Ω, controlling by switch;
z Line transmission protocol: HDLC;
z Supplying one Ethernet interface, port model is 10/100M adaptation;
z The max speed of filtration and transmission is 15,000 frames
z Ether port can connect with computer network card or Ethernet switchboard
per second
and other equipment;
z Reinforced TINYGRAM packing model
z Supplying two types clocks to choose: main clock and secondary clock;

1 2
DH2010A E1/10Base-T Conversion Equipment DH2010A E1/10Base-T Conversion Equipment

z The 10,000MAC
Meaning of DH 2010A E1/10Base-T indicator light (1)
Name Color Meaning of indicator Normal
3.3. Power Supply Condition light condition
POWER Green Equipment power source Bright
Voltage: AC220V AC 180V~240V; working indicator light
DC-48V DC -36V~-72V; LOS Red E1 signal losing warning Go out
Power Consumption: ≤5W indicator light
ACT Green Ethernet interface data Flicker
3.4.Working Environment indicator light
WANRX Green Wide Area Network (WAN) Flicker
z Working Temperature 0℃ ~ 50℃; data indicator light
z Storage Temperature: -40℃ ~ +70℃; WANTX Green WAN data indicator light Flicker
z Relative Humidity: 5% ~ 95% without cold agglutinin LINK Green Ethernet interface Bright
z Atmospheric Pressure: 86 ~ 106Kpa; connection indicator light
100M Green 100M Ethernet connection Bright or go
3.5.Size indicator light out

z 483mm×145mm×45mm The backboard of DH2010A


1,5=IN
IV. Appearance LAN RX 2,6=OUT
TX

The front board of DH2010A: 1234


POWER Functional Switch 75Ω 120Ω 75Ω

DH2010A E1/10Base-T The backboard of DH2010A E1/10Base-T Conversion Equipment

100M LINK WANTX WANRX ACT LOS POWER

The front board of DH2010A E1/10Base-T


Conversion Equipment

3 4
DH2010A E1/10Base-T Conversion Equipment DH2010A E1/10Base-T Conversion Equipment

V. On-0ff Switch Setup VI.Interface Definition

5.1. Foundational On-off Switch Setup 6.1.75ΩE1 interface definition


OFF
Marked with IN means receiving
ON 12 3 4
signal;
Switch Setup
Switch setup IN OUT Marked with OUT means sending
Switch ON OFF Instruction signal;
1 Main clock Secondary Clock setup
clock 6.2.120ΩE1 interface definition
1 2 3 4 5
2 Normal Loop-back Bust back
setup
3 3-ON 4-OFF 75Ω Resistance
3-OFF 4-ON 120Ω setup

P.S.: Pin number Functional definition Sense


1、 The equipment must be used as pair, you can setup the equipment as 1 RX+(Receive data +) Input
one main clock and one secondary clock when you use it. 2 TX+(Send data +) Output
2、 For example, you can set up the main clock as 1-ON 2-ON, and the 3 GND(ground)
secondary clock as 1-OFF 2-ON 4 NC(air)
3、 The resistance should be set according to users’ demands, 5 RX-(Receive data -) Input
when it’s 75Ω, setting as 3-ON 4-OFF; when it’s 120Ω, 6 TX-(Send data -) Output
setting as 3-OFF 4-ON. 7 GND(ground)
4、 When the equipment is configured as 75Ω, E1 data interface 8 NC(air)
should be BNC connector output; P.S.: 75Ω interfaces and 120Ω interfaces can’t be used
When the equipment is configured as 120Ω, E1 data interface simultaneously, they should be controlled by on-off switch.
should be RJ-45 connector output;

5 6
DH2010A E1/10Base-T Conversion Equipment DH2010A E1/10Base-T Conversion Equipment

VII.Plan Constructor

6.3.Ether interface Definition E1 传输环境:E1 Transmission Environment


中心局域网:Central LAN

1 2 3 4 5 6 7 8

DH2010A 机框

Ethernet interface definition


Pin number Function definition Sense
1 RX+(Receive data +) Input
2 RX-(Receive data -) Input
3 TX+(Send data +) Output DH2010A DH2010A DH2010A

4;5;7;8 NC(air)
6 TX-(Send data -) Output

When the equipment directly connects with computer network card,


please use-interlacing way of connecting line; VIII.Accessories
One power cable
When the equipment connects with line concentrator or Ethernet Two BNC spindle heads
INTerPreter, please direct way of connecting line. One RJ-45 connector
An Instruction Manual

7 8
DH2010A E1/10Base-T Conversion Equipment

IX. Warranty instruction


We supply one-year free repair service for consumers.

Instructions for free repair service:

1. Within one year of warranty period, we take free of charge repair


for damage under normal condition.
2. No free repair for damage caused by unauthorized repair.
3. Equipments that are out of warranty are not converted by the
free of charge repair and should be paid by the customer.