Вы находитесь на странице: 1из 9

Technical Document TD-ATV Settings

Issued by department: Date: Author: Approved by: Revision: Page:

R&D Department 20.11.2008 I.Lygren TOB 08 1 (9)


We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly
forbidden. ©AKVAgroup ASA.

AkvaMarina CCS Feed System

Settings for the ATV Frequency drives

TD-ATV Settings-07
Technical Document TD-ATV Settings
Issued by department: Date: Author: Approved by: Revision: Page:

R&D Department 20.11.2008 I.Lygren TOB 08 2 (9)


We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly
forbidden. ©AKVAgroup ASA.

Doser 1000:

Motor(0.37Kw), ATV31(0.75Kw):

SEt menu: drC menu: FUn menu: SUP menu:


ACC-0.1 nCr-1.8 Adc-nO LCr, Hold “ENT”
dEC-0.1 nSP-1370 for 2 Sec.
HSP-60 COS-0.78
ItH-1.8

VariDoser 1500:

Upper Motor(0.066Kw), ATV31(0.18Kw):

SEt menu: drC menu: FUn menu: SUP menu:


ACC-0.5 nCr-0.5 Adc-nO LCr, Hold “ENT”
dEC-0.5 nSP-1320 for 2 Sec.
HSP-100 COS-0.69
ItH-0.5 tFr-100

Lower Motor(0.37Kw), ATV31(0.75Kw):

SEt menu: drC menu: FUn menu: I/O menu:


ACC-1 nCr-1.8 Adc-nO r2-rUn
dEC-30 nSP-1370
LSP-40 COS-0.78 SUP menu:
HSP-40 LCr, Hold “ENT”
ItH-1.8 for 2 Sec.

Doser 4000:

Motor(0.75Kw), ATV31(0.75Kw):

SEt menu: drC menu: FUn menu: SUP menu:


ACC-0.1 nCr-3.2 Adc-nO LCr, Hold “ENT”
dEC-0.1 nSP-1395 for 2 Sec.
HSP-60 COS-0.81
ItH-3.2

VariSelector:

Motor(0.18Kw), ATV31(0.37Kw):

SEt menu: drC menu: FUn menu:


ACC-1 nCr-1.91 rPt-S
dEC-0.1 nSP-1350 BrA-nO
HSP-100 COS-0.77
ItH-1.0 tFr-100
FLG-85

1 nCr must be set to minimum 1.9 otherwise no OPF fault detection!

TD-ATV Settings-07
Technical Document TD-ATV Settings
Issued by department: Date: Author: Approved by: Revision: Page:

R&D Department 20.11.2008 I.Lygren TOB 08 3 (9)


We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly
forbidden. ©AKVAgroup ASA.

VariBlower Robuschi ATV38/58:

Motor(x.xxKw), ATV38/58(x.xxKw):

Set menu: drC menu: SUP menu:


ACC-10 nCr(7.5Kw)-15 rFr, Hold “ENT”
dEC-10 nCr(9Kw)-18 for 2 Sec.
HSP-60 nCr(11Kw)-21
ItH(7.5Kw)-15 nCr(15Kw)-28
ItH(9Kw)-18 nCr(18.5Kw)-34
ItH(11Kw)-21 nCr(22Kw)-40
ItH(15Kw)-28 nCr(30Kw)-53
ItH(18.5Kw)-34 nSP-2900
ItH(22Kw)-40 COS-0.9
ItH(30Kw)-53 Stt-Stn [On Ramp]
rPt-LIN
AdC-nO
brA-nO

VariBlower Kaeser ATV38/58:

Motor(x.xxKw), ATV38/58(x.xxKw):

Set menu (ATV38/58): drC menu (ATV38/58): SUP menu:


ACC-10 nCr(7.5Kw)-15 rFr, Hold “ENT”
dEC-10 nCr(9Kw)-18 for 2 Sec.
HSP-50 nCr(11Kw)-21
ItH(7.5Kw)-15 nCr(15Kw)-28
ItH(9Kw)-18 nCr(18.5Kw)-34
ItH(11Kw)-21 nCr(22Kw)-40
ItH(15Kw)-28 nCr(30Kw)-53
ItH(18.5Kw)-34 nSP-2945
ItH(22Kw)-40 COS-0.9
ItH(30Kw)-53 Stt-Stn [On Ramp]
rPt-LIN
AdC-nO
brA-nO

Note: ItH and nCr may vary from motor to motor, check motor rating plate.
After installation, Auto Tuning must be performed on all motors.
rPt, brA and Stt are set to default values but because of different setting
in the past they need to be checked/adjusted.

TD-ATV Settings-07
Technical Document TD-ATV Settings
Issued by department: Date: Author: Approved by: Revision: Page:

R&D Department 20.11.2008 I.Lygren TOB 08 4 (9)


We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly
forbidden. ©AKVAgroup ASA.

VariBlower Robuschi ATV61:


Motor(x.xxKw), ATV61(x.xxKw):
2.Access Level(LAC-)
LAC-EPr [Expert]
1.3 Settings menu(SEt-)(ATV61): 1.4 Motor Control menu(drC-)(ATV61):
ACC-10 nCr(7.5Kw)-15
dEC-10 nCr(9Kw)-18
HSP-60 nCr(11Kw)-21
ItH(7.5Kw)-15 nCr(15Kw)-28
ItH(9Kw)-18 nCr(18.5Kw)-34
ItH(11Kw)-21 nCr(22Kw)-40
ItH(15Kw)-28 nCr(30Kw)-53
ItH(18.5Kw)-34 nCr(37Kw)-64
ItH(22Kw)-40 nCr(45Kw)-77
ItH(30Kw)-53 nSP-2900
ItH(37Kw)-64 nPr-9,11,15,18.5,22,30,37 or 45Kw
ItH(45Kw)-77 Ctt-UUC [SVC V]
SPG-25%
SLP-0%
1.5 Inputs/Outputs CFG(I-O-)(ATV61): 1.7 Application Funct.(Fun-)(ATV61):
AIIF-3S rPt-Lin [Linear]
brA-yES
Stt-rnP[Ramp stop]
AdC-nO
1.8 Fault Management(FLt-)(ATV61): Monitoring menu(ATV61):
FLr-yES [Catch on the fly] Output Freq.
Motor Current

VariBlower Kaeser ATV61:


Motor(x.xxKw), ATV61(x.xxKw):
2.Access Level(LAC-)
LAC-EPr [Expert]
1.3 Settings menu(SEt-)(ATV61): 1.4 Motor Control menu(drC-)(ATV61):
ACC-10 nCr(7.5Kw)-15
dEC-10 nCr(9Kw)-18
HSP-50 nCr(11Kw)-21
ItH(7.5Kw)-15 nCr(15Kw)-28
ItH(9Kw)-18 nCr(18.5Kw)-34
ItH(11Kw)-21 nCr(22Kw)-40
ItH(15Kw)-28 nCr(30Kw)-53
ItH(18.5Kw)-34 nCr(37Kw)-64
ItH(22Kw)-40 nCr(45Kw)-77
ItH(30Kw)-53 nSP-2945
ItH(37Kw)-64 nPr-9,11,15,18.5,22,30,37 or 45Kw
ItH(45Kw)-77 Ctt-UUC [SVC V]
SPG-25%
SLP-0%
1.5 Inputs/Outputs CFG(I-O-)(ATV61): 1.7 Application Funct.(Fun-)(ATV61):
AIIF-3S rPt-Lin [Linear]
brA-yES
Stt-rnP[Ramp stop]
AdC-nO
1.8 Fault Management(FLt-)(ATV61): Monitoring menu(ATV61):
FLr-yES [Catch on the fly] Output Freq.
Motor Current

Note: ItH and nCr may vary from motor to motor, check motor rating plate.
After installation, Auto Tuning must be performed on all motors.

TD-ATV Settings-07
Technical Document TD-ATV Settings
Issued by department: Date: Author: Approved by: Revision: Page:

R&D Department 20.11.2008 I.Lygren TOB 08 5 (9)


We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly
forbidden. ©AKVAgroup ASA.

rPt, brA and Stt are set to default values but because of different setting
in the past they need to be checked/adjusted.

Auto tuning the ATV61, Motor Control menu(drC-):

TD-ATV Settings-07
Technical Document TD-ATV Settings
Issued by department: Date: Author: Approved by: Revision: Page:

R&D Department 20.11.2008 I.Lygren TOB 08 6 (9)


We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly
forbidden. ©AKVAgroup ASA.

Auto tuning the ATV31, drC menu:

TD-ATV Settings-07
Technical Document TD-ATV Settings
Issued by department: Date: Author: Approved by: Revision: Page:

R&D Department 20.11.2008 I.Lygren TOB 08 7 (9)


We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly
forbidden. ©AKVAgroup ASA.

Auto tuning the ATV38/58, drC menu:

TD-ATV Settings-07
Technical Document TD-ATV Settings
Issued by department: Date: Author: Approved by: Revision: Page:

R&D Department 20.11.2008 I.Lygren TOB 08 8 (9)


We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly
forbidden. ©AKVAgroup ASA.

Auger and Sluice section

Doser 4000 (60009) used as a sluice valve:

Motor(0.75Kw), ATV31(0.75Kw):

SEt menu: drC menu: FUn menu: SUP menu:


ACC-1 nCr-3.2 Adc-nO LCr, Hold “ENT”
dEC-60 nSP-1395 for 2 Sec.
LSP-50 COS-0.81
HSP-50
ItH-3.2

Sluice 4000 (0101090) used as a sluice valve:

Motor(0.75Kw), ATV31(0.75Kw):

SEt menu: drC menu: FUn menu: SUP menu:


ACC-1 nCr-3.2 Adc-nO LCr, Hold “ENT”
dEC-60 nSP-1380 for 2 Sec.
LSP-50 COS-0.75
HSP-50
ItH-3.3

Sluice CCS90 (0102634) BL 200/1 Westinghouse used as a sluice valve:

Motor(0.75Kw), ATV31(0.75Kw):

SEt menu: drC menu: FUn menu: SUP menu:


ACC-1 nCr-3.2 Adc-nO LCr, Hold “ENT”
dEC-60 nSP-1395 for 2 Sec.
LSP-50 COS-0.81
HSP-50
ItH-3.2

Option, manuel RPM control for all sluice valves:


Change this parameter:
LSP-30

Auger CCS (X)m (0102633, 0102735) with 0.75Kw Motor:


Motor(0.75Kw), ATV31(0.75Kw):

SEt menu: drC menu: FUn menu: SUP menu:


ACC-0.1 nCr-3.2 Adc-nO LCr, Hold “ENT”
dEC-0.1 nSP-1395 for 2 Sec.
HSP-60 COS-0.81 I/O menu:
ItH-3.2 r2-rUn

Auger (Old SS type) with 1.5Kw Motor:


Motor(1.5Kw), ATV31(1.5Kw):

SEt menu: drC menu: FUn menu: SUP menu:


ACC-0.1 nCr-5.9 Adc-nO LCr, Hold “ENT”
dEC-0.1 nSP-1320 for 2 Sec.
HSP-60 COS-0.81 I/O menu:
ItH-5.9 r2-rUn

TD-ATV Settings-07
Technical Document TD-ATV Settings
Issued by department: Date: Author: Approved by: Revision: Page:

R&D Department 20.11.2008 I.Lygren TOB 08 9 (9)


We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly
forbidden. ©AKVAgroup ASA.

Revision information:

04/08-2008: Rev06 to Rev07, Varidoser 1500, Lower Motor, I/O menu, changed from
SrA to rUn.

07/09-2008: Rev07 to Rev08, VariSelector, added in Set menu, FLG-85

20/11-2008: Rev08 to Rev09, Added motor 37Kw and 45Kw

TD-ATV Settings-07