Академический Документы
Профессиональный Документы
Культура Документы
www.sea.siemens.com/powermod
names of Siemens AG or supplier companies whose use by Answers for industry.
third parties for their own purposes could violate the rights
of the owners.
One-pole AFCI Two-pole AFCI
$PNCJOBUJPO5ZQF"'$*
N Siemens offers multiple ways to save the contractor time and money.
Siemens is proud to introduce Power Mod™ with QuickSystem™ - a new robust and feature-
rich line of modular metering designed with the contractor in mind. Power Mod features a
unique combination of labor saving features to aid the contractor while installing the product.
QuickSystem encompasses every step of installation of the product - from mounting the product
on the wall to plugging in the tenant circuit breaker - these five key features were specifically
engineered to decrease installation time. Power Mod offers a wide range of products to meet
applications for virtually every need.
From our new underground only mains for EUSERC applications to our exclusive six high 225
Amp Residential Meter Stack - Siemens can meet your multi family metering needs. Quality
and service are keystones of the Power Mod line. Siemens Power Mod has been tested to all
applicable UL and ANSI standards as well as Siemens’ own rigorous internal specifications.
Every module offers 1200 Amp thru-bussing as a standard feature. Every meter stack offers
fully rated vertical bussing. All of this delivered at a competitive time and price to other, lower
rated products.
*OUSPEVDUJPO
www.sea.siemens.com/powermod
Power Mod
QuickSystem™ Features
Contractor-focused features, robust quality, dependable service, and exclusive products define Siemens Power Mod. The new
standard in multi family metering. QuickSystem showcases the key strengths of Power Mod through five labor saving features:
Siemens
exclusive
QuickConnect™ feature
QuickTorque™
Siemens
exclusive
QuickBolt™ feature
Siemens
exclusive
QuickRoll™ feature
QuickPhase™
4JFNFOT.PEVMBS.FUFSJOHJODMVEFTBOBTTPSUNFOUPGNPEVMFUZQFTUIBUDBOCFDPOÙHVSFEUPNFFUBXJEFSBOHFPGSFTJEFOUJBMBOE
DPNNFSDJBMHSPVQNFUFSJOHBQQMJDBUJPOT
4JFNFOTNPEVMBSNFUFSJOHQSPWJEFTGPSTJOHMFQIBTF
UISFFXJSF
7"$UISFFQIBTF
GPVSXJSF:
BQQMJDBUJPOT
BOEUISFFQIBTFJOPVU
7PMUNBYEFMUBTZTUFNT5IFDSPTTCVTUIBUDPOOFDUTEFWJDFTJTBMVNJOVNBOEIBTB
"NQDPOUJOVPVTDVSSFOUSBUJOH
"UZQJDBMBQQMJDBUJPOSFRVJSFTBNBJOEFWJDFNPEVMFBOEPOFPSNPSFSFTJEFOUJBMPSDPNNFSDJBMNFUFSTUBDLT%FQFOEJOHPOUIF
BQQMJDBUJPOBEEJUJPOBMNPEVMFTTVDIBTQVMMCPY
UBQCPY
PSBTQBDFSNBZCFSFRVJSFE
2VJDL$POOFDUt
5IFUJNFTBWJOH2VJDL$POOFDUt 2$
QSPWJEFTBTJOHMFDPOOFDUJPOGPSQIBTF
OFVUSBM
BOE
HSPVOEqBMMUJHIUFOFECZBTJOHMFOVUUIBUJTFYUFSOBMMZBDDFTTJCMF#FWFMFEFEHFTPOUIF2$
BMMPXGPSFBTZQPTJUJPOJOHPGUIFKPJOU'BDUPSZJOTUBMMFE2VJDL#PMUtTQSJOHMPBEFECPMUTBSF
MPDBUFEKVTUBCPWFBOECFMPXUIF2$PQFOJOHUPDPNQSFTTUIFTVSSPVOEJOHHBTLFUTUPHFUIFS
UPGPSNBXBUFSUJHIUTFBM'PSFYUSBTUBCJMJUZBEEJUJPOBMOVUTBOECPMUTBCPWFBOECFMPX
2VJDL#PMUTBSFJODMVEFEBTBNFBOTPGQIZTJDBMMZKPJOJOHUIFNFUFSTUBDLTUPHFUIFSCPUI
BCPWFBOECFMPXUIF2$PQFOJOH
#VT$POTUSVDUJPO
6ONFUFSFECVTJTTVSSPVOEFECZBCBSSJFSBOEBMMJOBDDFTTJCMFCVTDPOOFDUJPOTBSF
XFMEFEGPSNBYJNVNTUSFOHUI"MMPUIFSDPOOFDUJPOT2VJDL$POOFDUtBOENFUFSTPDLFU
DPOOFDUJPOT
BSFCPMUFEBOEBDDFTTJCMF
/FVUSBM(SPVOE1SPWJTJPOT
Siemens 8...PEVMF/FVUSBM(SPVOE1SPWJTJPOTBSFMPDBUFEPOUIFCPUUPNFOEPGUIFNFUFS
exclusive NPEVMFT"MMHSPVOETBOEOFVUSBMTNBZCFSFMPDBUFEUPUIFUPQPGUIFFODMPTVSFJGBUPQFYJU
feature JTOFFEFE&BDINFUFSNPEVMFIBTIBMGTIFBSTUPIFMQMPDBUFBÙFMEDVULOPDLPVUJGBUPQFYJU
JTQSFGFSSFE
5FOBOU#SFBLFS1SPWJTJPOT
&BDI"NQNFUFSTPDLFUIBTBQSPWJTJPOGPSBQPMF"NBYQMVHJOUZQF24DJSDVJU
CSFBLFS5IFDPNQBDU24CSFBLFSÙUTJOUXPJODIFTBOESFEVDFTFODMPTVSFTJ[FMJNJUFEUPUBM
NPVOUJOHTQBDFSFRVJSFE4JOHMFSJHIUIBOECFOEXJSJOHTBWFTUJNFBOEXJSF*OTFSUB"
21JOUPB"NQ24TMPUXJUIPVUDPOWFSTJPOLJUTPSÙMMFSQMBUFT(FOFSPVTHVUUFSTQBDF
BMMPXTGPSXJSJOHGPSUPQ
CPUUPN
PSCBDLPGUIFNFUFSNPEVMF&BDINFUFSDPWFSJT
FNCPTTFEUPQSPWJEFBMPDBUJPOGPSUIFVOJU BQBSUNFOU
OVNCFS
8...PEVMFGBDUPSZQIBTJOHJTBTGPMMPXT
(BOH"#
#$
(BOH"#
#$
$"
(BOH"#
#$
$"
"#
(BOH"#
#$
$"
"#
#$
(BOH"#
#$
$"
"#
#$
$"
"OZQPTJUJPODBOCFBEKVTUFEUPBOZQIBTF
Siemens Power Mod offers a wide array of modules to meet the needs of almost any 240V application. Modules are grouped and
categorized by function and type to facilitate the selection and ordering process. The basic modules are:
Standard Breaker Modules (type WB)
These modules are designed for line and load side applications ranging from 200 to 2000 Amps at 240V
AC Max. For 1200 Amp and below modules compression lug landing pads can be field installed and devices
are rated for overhead and underground feed. 1600-2000 Amp models feature dedicated feed to minimize
width and come with factory installed studs to which mechanical or compression lugs can be installed.
A wide variety of lug options for AL and CU wire are available to help minimize cost and customize the
module to your specifications. All modules in this family feature the four most basic QuickSystem features:
QuickConnect, QuickBolt, QuickRoll, and QuickTorque.
&64&3$$PNQMJBOU5BQCPY1VMMCPY$PNCJOBUJPO.PEVMFT UZQF8&5
3FTJEFOUJBMTUBDLNPEVMFTBSFBWBJMBCMFJO"NQBOE"NQQFSQPTJUJPONPEVMFT5XPUISPVHITJY
QPTJUJPOEFWJDFTJOBOE"NQBSFBWBJMBCMFJOSJOH
SJOHMFTTXJUIBOEXJUIPVUIPSOCZQBTT.PEVMFT
XJUIUISFFQIBTFUISPVHICVTIBWFUIF2VJDL1IBTFGFBUVSFXIJDIFOBCMFTÙFMEQIBTJOHQFSQPTJUJPO
BMMPXJOHUIFVTFSUPDVTUPNJ[FUIFTUBDLUPUIFJSTQFDJÙDOFFET"NQNPEVMFTVTFUIFOFX24UZQF
CSFBLFSXIJDIFMJNJOBUFTNVMUJQMFCFOETJOUFOBOUTFSWJDFDPOEVDUPSTBOEBMMPXTGPS"NQDPOWFSTJPO
XJUIPVUUIFOFFEGPSDPTUMZBOEMBCPSJOUFOTJWFDPOWFSTJPOLJUT"MMNPEVMFTJOUIJTGBNJMZGFBUVSFUIF
DPNQMFUF2VJDL4ZTUFNGFBUVSFTFU2VJDL$POOFDU
2VJDL#PMU
2VJDL3PMM
2VJDL1IBTFBOE2VJDL5PSRVF
$PNNFSDJBM.FUFS4UBDLTXJUI-FWFS#ZQBTT UZQF8.-
-FWFSCZQBTTDPNNFSDJBMNFUFSTUBDLTBSFBWBJMBCMFXJUI7"$NBYTJOHMFBOEUISFFQIBTFUFOBOUNBJO
QSPWJTJPOT5IJTGBNJMZPGGFST"NQXJUIUISFFQIBTFUFOBOUNBJOTXJUIVQUPGPVSQPTJUJPOT
"NQ
XJUITJOHMFBOEUISFFQIBTFUFOBOUNBJOTXJUIVQUPGPVSQPTJUJPOT
BOE"NQXJUITJOHMFBOEUISFF
QIBTFUFOBOUNBJOTVQUPUXPQPTJUJPOT$PNNFSDJBMUZQF8.-TUBDLTVTFUIF-BOEJT(ZSUZQF)2
MFWFSCZQBTTXIJDIIBTMFEUIFJOEVTUSZGPSGPSUZZFBSTJORVBMJUZBOEQFSGPSNBODF4UBDLTXJUITJOHMF
QIBTF"NQQSPWJTJPOTDBOCFDPOWFSUFEUP"NQXJUIPVUUIFOFFEGPSDPTUMZBOEMBCPSJOUFOTJWF
DPOWFSTJPOLJUT"MMNPEVMFTJOUIJTGBNJMZGFBUVSFUIFGPVSCBTJD2VJDL4ZTUFNGFBUVSFT2VJDL$POOFDU
2VJDL#PMU
2VJDL3PMM
BOE2VJDL5PSRVF
&64&3$$PNQMJBOU$PNNFSDJBM.FUFS4UBDLTXJUI5FTU#MPDL#ZQBTT UZQF8.5
5FTUCMPDLCZQBTTDPNNFSDJBMNFUFSTUBDLTBSF&64&3$DPNQMJBOUBOEBSFBWBJMBCMFXJUITJOHMFQIBTFBOE
UISFFQIBTFPVUQVUUFOBOUNBJOQSPWJTJPOT5IJTGBNJMZPGGFST"NQUFOBOUNBJOTXJUITJOHMFBOEUISFF
PVUQVUXJUIVQUPUISFFQPTJUJPOT4UBDLTXJUITJOHMFQIBTF"NQQSPWJTJPOTDBOCFDPOWFSUFEUP
"NQXJUIPVUUIFOFFEGPSDPTUMZBOEMBCPSJOUFOTJWFDPOWFSTJPOLJUT"MMNPEVMFTJOUIJTGBNJMZGFBUVSFUIF
GPVSCBTJD2VJDL4ZTUFNGFBUVSFT2VJDL$POOFDU
2VJDL#PMU
2VJDL3PMM
BOE2VJDL5PSRVF
$PNNFSDJBM.FUFS4UBDLTXJUI,#BTF.FUFS4PDLFUT UZQF8.,
,#BTFJTBCPMUJONFUFSTPDLFUEFTJHOFEBOEQSPWJEFEFYDMVTJWFMZCZ-BOEJT(ZS6UJMJUZBDDFQUBODFWBSJFT
TPQMFBTFDIFDLGPSBQQSPWBMQSJPSUPVTJOHPOFPGUIFTFEFWJDFT,#BTFDPNNFSDJBMNFUFSTUBDLTBSF
BWBJMBCMFXJUI7"$NBYTJOHMFBOEUISFFQIBTFUFOBOUNBJOQSPWJTJPOT4JOHMFQIBTFJOBOEPVUEFWJDFT
VUJMJ[FUIF,NFUFSTPDLFU5ISFFQIBTFJOBOETJOHMFQIBTFPVUEFWJDFTVTFUIF,NFUFSTPDLFUBOEUISFF
QIBTFJOXJUIUISFFQIBTFPVUVUJMJ[FUIF,NFUFSTPDLFU"MMEFWJDFTBSFPGGFSFEJOPOFQPTJUJPOBOE
"NQDPOÙHVSBUJPOT5IF,NPEVMFTBSFPGGFSFEXJUIUXPQPTJUJPOTBU"NQTQFSQPTJUJPO"MM
NPEVMFTJOUIJTGBNJMZGFBUVSFUIFGPVSCBTJD2VJDL4ZTUFNGFBUVSFT2VJDL$POOFDU
2VJDL#PMU
2VJDL3PMM
BOE2VJDL5PSRVF
"DDFTTPSJFT
5IF1PXFS.PEGBNJMZPGGFSTBXJEFWBSJFUZPGBDDFTTPSJFTUPDVTUPNJ[FUIFQSPEVDUTUPZPVSQBSUJDVMBS
BQQMJDBUJPO5IJTGBNJMZJODMVEFT
4QBDFSTVTFEUPQVUEJTUBODFCFUXFFOBNBJOBOETUBDLXIFSFSFRVJSFEPSKVTUUPFYUFOEUIFMFOHUI
PGUIFMJOFVQ
&MCPXT/&."SBUFEEFWJDFTEFTJHOFEUPUVSOBMJOFVQBSPVOEBOJOTJEFDPSOFS
1VMMCPYFT&64&3$DPNQMJBOUVOEFSHSPVOEQVMMTFDUJPOGPSVTFXJUITUBOEBSECSFBLFSBOETXJUDIVOJUT
-VHTUIFXJEFTUBSSBZPGMVHPQUJPOTJOUIFJOEVTUSZGPDVTJOHPOPGGFSJOHUIFNPTUFDPOPNJDBMTPMVUJPO
GPSZPVSBQQMJDBUJPO
.JTDÙFMEJOTUBMMBCMFUIKBXLJUT
IVCT
SFQMBDFNFOUQBSUT
The service feed for a Modular Metering configuration can be on the end of the configuration or in the middle.
J Configurations are limited by the continuous current J All meter stack horizontal bussing must match the
ratings for the main device and the cross bus. All cross output (three phase or single phase) of the main
buses are aluminum with 1200 Amp continuous current disconnect module.
rating. For center fed applications, the total current in the
main device may exceed 1200 Amps if the main device is J Each meter stack comes with a QuickConnectTM and a
rated accordingly, but the cross bus current on either side mounting rail. A QuickConnect is needed for each cross
of the main device cannot exceed 1200 Amps. bus connection.
J Pullboxes have provisions for field installed lugs for J Utilities have varying requirements for equipment height,
incoming and outgoing conductors. These modules cover types, and bypass types. Therefore, utility acceptance
should be used for underground service feeds when should be obtained prior to installation of any modules.
inspecting authorities require the service to be split.
Pullboxes do not have horizontal cross bus. If a J Order a circuit breaker tenant main for each meter position.
connection to cross bus is needed a tap box (type WTB,
WET) should be used. J Circuit breakers must be single phase or three phase
to match the output of the meter stack. Refer to the
J 200 to1200 Amp standard breaker modules accept Siemens Speedfax catalog for circuit breaker series
combination feed allowing service conductors to enter rating information.
the top or bottom of the enclosure. 1600 to 2000 Amp
standard breaker modules have dedicated top or bottom J Standard tapboxes and circuit breakers (type WTB, WB)
feed. 400 to 800 Amp switch modules are invertible for may be used as a service entrance module or a load side
top or bottom feed. 1200 Amp switches are bottom feed feed for remote equipment. An additional QuickConnect
only. All standard tapboxes are invertible for top or must be ordered when using these devices on the load
bottom feed. Invertible units come with two sets of two side to feed remote equipment.
QuickBoltsTM on both sides of the unit. The QuickBolts on
the left side must be removed by taking off two mounting J Tapboxes provide a direct connection to the cross bus
screws on each QuickBolt assembly. and do not provide any overcurrent protection. Tapboxes
should neverbe used to feed other main devices (WS, WB,
J A spacer is commonly required between a meter stack and WES, WEB) as this would bypass the overcurrent protection.
the main disconnect module (or tapbox) for a EUSERC
installation. A spacer can also be used to extend the length
of the lineup when needed.
Configuration Examples: The following illustration shows a few configuration examples. Other configurations are also possible.
For simplicity, only one or two meters stacks are shown for each configuration, but additional meter stacks can be added as long as
the cross bus and main device specifications are not exceeded.
Incoming Incoming
Service Service Incoming
Service
Busway Spacer
Tap (when needed)
Stack
Incoming Incoming
Service Service
Tapbox
Main Breaker
This configuration has no main disconnect 1600/2000
and can only be used when there are Modular metering example with service entrance
six or fewer disconnects in the center
(Center-fed configurations are used when the required
Modular metering example with service current exceeds 1200 Amps.)
entrance on the end.
Accessories 12-1
Power Mod™
J 2-6 gang
J 125/225 Amp per position
J 1200 Amp thru-bus rating
J UL standard 67
J UL file no. E27100
J AIC rating (65k & 100k)
J Voltage:
- Single phase 120/240V AC max.
- Three phase in single phase out
120/208V AC max.
240/120V AC max.
J All swing latches and rivets are stainless steel.
J NEMA 3R rated
J G90 galvanized steel
J ANSI 61 paint
1
Power Mod Residential Meter Stacks
QuickSystem Features
QuickRoll™
A Siemens exclusive feature, QuickRoll eliminates the typical metal brackets for
mounting modules to the wall. Instead of metal scraping metal, QuickRoll allows the
module to glide down the mounting rail via a durable nylon wheel inside a mounting
bracket.
QuickConnect™
QuickTorque™
Eliminates the need for time consuming torque readings, this breakaway nut provides
the correct indication of torque of the QuickConnect. When tightened, the outer
head twists off at the proper torque for connection, leaving a single nut for future
maintenance.
QuickBolt™
QuickPhase™
Each individual meter position can be phased independently according to the users
needs. QuickPhase allows the user the ultimate flexibility to adjust to each individual
application.
Siemens
exclusive
feature
QuickRoll™
Siemens
exclusive
feature
QuickConnect™
QuickTorque™
Siemens
exclusive
feature
QuickBolt™
QuickPhase™
Moveable neutral
Allows for top or bottom configuration
helping save length needed for wire.
Rain channel
Moveable to simplify wiring.
Moveable ground
Allows for top or bottom
configuration helping save
on wire costs.
Residential 4-jaw ring type meter stacks: 1-phase, 3-wire SN, incoming and outgoing1
Max. Field
Dimensions (inches) /
Meter tenant installed KO
Catalog positions breaker Breaker Maximum 5th jaw drawing Schematic
number per stack (Amps) provision AIC3 Height Width Depth assembly2 no. no.
Residential 4-jaw ringless type meter stacks: 1-phase, 3-wire SN, incoming and outgoing1
WMM21125R WMM21125RB 2 Position 65,000 34.31 13.09 8.09 ECMF5 KA-12 SA-12
WMM31125R WMM31125RB 3 Position QP, QPH, 65,000 43.31 13.09 8.09 ECMF5 KA-13 SA-13
HQP, MP-T,
WMM41125R WMM41125RB 4 Position 125 65,000 52.31 13.09 8.09 ECMF5 KA-14 SA-14
MP-HT,
WMM51125R WMM51125RB 5 Position MP-MT 65,000 61.31 13.09 8.09 ECMF5 KA-15 SA-15
WMM61125R WMM61125RB 6 Position 65,000 70.31 13.09 8.09 ECMF5 KA-16 SA-16
WMM21225R WMM21225RB 2 Position QS, QSH, 100,000 34.31 16.22 8.09 ECMF5 KA-22 SA-12
WMM31225R WMM31225RB 3 Position QSHH, HQS, 100,000 43.31 16.22 8.09 ECMF5 KA-23 SA-13
HQSH, QP,
WMM41225R WMM41225RB 4 Position 225 0
QPH, HQP, 100,000 52.31 16.22 8.09 ECMF5 KA-24 SA-14
MP-T,
WMM51225R WMM51225RB 5 Position MP-HT, 100,000 61.31 16.22 8.09 ECMF5 KA-25 SA-15
WMM61225R WMM61225RB 6 Position MP-MT 100,000 70.31 16.22 8.09 ECMF5 KA-26 SA-16
/ Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions.
0 225A available in lower three positions only.
1 NOT for use on 3-phase, 4-wire delta systems.
2 5th jaw can be isolated if needed.
3 Max AIC determined by maximum AIC of tenant breakers. Higher ratings may be achieved through approved series rating combinations.
Residential 5-jaw ring type meter stacks: 3-phase, 4-wire SN, incoming and 1-phase, 3 wire SN outgoing1
Max.
Dimensions (inches)/
Meter tenant Factory KO
Catalog positions breaker Breaker Maximum stack phasing drawing Schematic
number per stack (Amps) provision AIC3 Height Width Depth phases/sockets4 no. no.
Residential 5-jaw ringless type meter stacks: 3-phase, 4-wire SN, incoming and 1-phase, 3 wire SN outgoing1
Max.
Catalog Catalog Meter tenant Dimensions (inches)/ Factory KO
number number positions breaker Breaker Maximum stack phasing dwg. Schematic
(no bypass) (Horn Bypass) per stack (Amps) provision AIC 3 Height Width Depth phases/socket4 no. no.
WMM22125RJ WMM22125RJB 2 Position 65,000 34.31 13.09 8.09 AB, BC KA-12 SA-32
WMM32125RJ WMM32125RJB 3 Position QP, QPH, 65,000 43.31 13.09 8.09 AB, BC, CA KA-13 SA-33
HQP, MP-T,
WMM42125RJ WMM42125RJB 4 Position 125 65,000 52.31 13.09 8.09 AB, BC, CA, AB KA-14 SA-34
MP-HT,
WMM52125RJ WMM52125RJB 5 Position MP-MT 65,000 61.31 13.09 8.09 AB, BC, CA, AB, BC KA-15 SA-35
WMM62125RJ WMM62125RJB 6 Position 65,000 70.31 13.09 8.09 2-AB, 2-BC, 2-CA KA-16 SA-36
WMM22225RJ WMM22225RJB 2 Position QS, QSH, 100,000 34.31 16.22 8.09 AB, BC KA-22 SA-32
WMM32225RJ WMM32225RJB 3 Position QSHH, HQS, 100,000 43.31 16.22 8.09 AB, BC, CA KA-23 SA-33
HQSH,
WMM42225RJ WMM42225RJB 4 Position 2250 QP, QPH, 100,000 52.31 16.22 8.09 AB, BC, CA, AB KA-24 SA-34
HQP, MP-T,
WMM52225RJ WMM52225RJB 5 Position MP-HT, 100,000 61.31 16.22 8.09 AB, BC, CA, AB, BC KA-25 SA-35
WMM62225RJ WMM62225RJB 6 Position MP-MT 100,000 70.31 16.22 8.09 2-AB, 2-BC, 2-CA KA-26 SA-36
/ Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions.
0 225A available in lower three positions only.
1 Approved for use on 3-phase, 4-wire delta systems.
2 5th jaw can be isolated if needed.
3 Max AIC determined by maximum AIC of tenant breakers. Higher ratings may be achieved through approved series rating combinations.
4 Residential Stacks are field phaseable
2-9/32
13-3/32
13-3/32 8-3/32
8-3/32
61-5/16
36" TO
70-5/16
BOTTOM OF
QUICK ROLL
BRACKET
36" TO
BOTTOM OF
9"
QUICK ROLL
TYP.
BRACKET
3-1/4 24-3/8 TO
CROSS BUS
CENTER
2-9/32
9"
12-5/32 TYP.
(6) KOs 1, 1-1/4, 1-1/2, 2" 2-13/16
24-3/8 TO
2-13/32 CROSS BUS
125 Amp Typical Bottom View CENTER
KA-15 2-7/16
(6) KOs 1, 1-1/4, 1-1/2, 2"
REMOVABLE PLATE
WMM52125XXX 12-31/32
KA-16
WMM61125XX
WMM62125XXX
36" TO 36" TO
BOTTOM OF BOTTOM OF 34-5/16
QUICK ROLL 43-5/16 QUICK ROLL 52-5/16
27" TO 36" TO 36" TO 36" TO 36" TO
BRACKET BRACKET
BOTTOM OF BOTTOM OF BOTTOM OF BOTTOM OF BOTTOM OF
QUICK ROLL QUICK ROLL QUICK ROLL 43-5/16 43-5/16
QUICK ROLL 52-5/16 QUICK ROLL
BRACKET BRACKET 9" BRACKET BRACKET BRACKET
34-5/16
TYP.
27" TO
TTOM OF 9" 9"
36" TO
CK ROLL TYP. TYP.
15-3/8 TO BOTTOM OF
RACKET QUICK ROLL 52-5/16
CROSS BUS 9" 9" 9" 9"
24-3/8 TO CENTER TYP. 24-3/8 TO TYP. TYP. BRACKET TYP.
CROSS BUS CROSS BUS
CENTER 12-5/32CENTER
24-3/8 TO 24-3/8 TO 24-3/8 TO 24-3/8 TO
15-3/8 TO 2-13/16 CROSS BUS CROSS BUS CROSS BUS CROSS BUS
CROSS BUS 12-5/32 CENTER CENTER 12-5/32 CENTER CENTER
CENTER 2-13/32
2-13/16 2-13/16 9"
12-5/32 12-5/32 12-5/32 12-5/32 TYP.
2-13/32 2-13/32
2-13/16 2-13/16
(6) KOs 1, 1-1/4, 1-1/2, 2" 2-13/16 2-13/16 2-13/16
2-7/16 24-3/8 TO
REMOVABLE PLATE
2-13/32 2-13/32 2-13/32 CROSS BUS
2-13/32 2-13/32
1-5/8(6)
TYP.
KOs 1, 1-1/4, 1-1/2, 2" (6) KOs 1, 1-1/4, 1-1/2, 2" CENTER
2-7/16 REMOVABLE PLATE 2-7/16 REMOVABLE PLATE
16-3/32
12-5/32
1-5/8 TYP. (6) KOs 1, 1-1/4, 1-1/2, 2" 1-5/8 TYP. (6) KOs 1, 1-1/4, 1-1/2, 2" (6) KOs 1, 1-1/4, 1-1/2, 2" (6) KOs 1, 1-1/4, 1-1/2, 2"
2-7/16 2-7/16 2-7/16 REMOVABLE PLATE REMOVABLE PLATE 2-7/16 2-7/16
16-7/32
REMOVABLE PLATE 2-13/16 REMOVABLE PLATE
1-5/8 TYP.
16-3/32 KA-22 1-5/8 TYP.
16-3/32
1-5/8 TYP. 1-5/8 TYP. 1-5/8 TYP.
2-13/32
16-3/32 16-3/32 16-3/32 16-3/32
WMM21225XX
WMM22225XXX 2-7/16
(6) KOs 1, 1-1/4, 1-1/2, 2"
8-3/32 KA-23 REMOVABLE PLATE
1-5/8 TYP.
WMM31225XX 16-3/32
WMM32225XXX
KA-24
WMM41225XX
WMM42225XXX
16-7/32
8-3/32
61-5/16
70-5/16
36" TO
BOTTOM OF
4" TYP. QUICK ROLL
BRACKET
2" TYP.
36" TO
2-3/16 BOTTOM OF
QUICK ROLL
9" BRACKET
TYP.
3-1/4 24-3/8 TO
CROSS BUS
CENTER 9"
2-9/32 TYP.
12-5/32
2-13/16 24-3/8 TO
(6) KOs 1-1/2, 2, 2-1/2" CROSS BUS
2-13/32 CENTER
225 Amp Typical Bottom View 12-5/32
(6) KOs 1, 1-1/4, 1-1/2, 2"
2-7/16 2-13/16
REMOVABLE PLATE
16-3/32
(6) KOs 1, 1-1/4, 1-1/2, 2"
2-7/16
KA-25 REMOVABLE PLATE
1-5/8 TYP.
WMM51225XX 16-3/32
WMM52225XXX
KA-26
WMM61225XX
WMM62225XXX
Equip.
Grd. Equip.
Grd.
Equip.
Grd.
SA-12
WMM21125XX
WMM21225XX Equip.
Grd.
SA-13
WMM31125XX Equip.
WMM31225XX Grd.
Equip.
Grd.
Equip.
Grd.
Equip.
Equip. Equip. Grd.
Grd. Grd.
Equip.
Grd. Equip.
Grd.
A B C
A B C
A A A A
N N N N
B B
B B
C C
C C
Equip.
Grd.
SA-32 Equip.
Grd.
WMM22125XXX
WMM22225XXX
SA-33
WMM32125XXX Equip.
WMM32225XXX Grd.
A B C
Equip.
Grd.
A B C
Equip.
Grd.
A B C
A A
A A A A N N
N N N N B B
B B B B C C
C C C C
W M M 2 1 125 R J B
Horn Bypass
Amperage
Enclosure B = Horn Bypass
Position 125 Installed
WMM = Residential
Meter Stack 2 = 2 Position 225 Blank = No Horn Bypass
Installed
3 = 3 Position
4 = 4 Position Jaws
Phase R = Ringless
Features include:
J QuickSystem™ features
J Compression lug landing pads (field install up to
1200 Amps, standard feature up to 2000 Amps)
J Combination overhead and underground feed up to
1200 Amps, dedicated overhead or underground feed
up to 2000 Amps
J 750kcmil AL wire options
J 65K AIC standard, 100K AIC available for all models
J Removable blank bottom endwall
J Externally accessible breaker handle with padlock
capability
J Broad ampacity ratings up to 2000 Amps with
non-standard amperages available (such as 700,
900, etc.)
J Field installable shunt trips
J 200-2000A
J 1200A thru-bus rating
J UL Standard # UL67
J UL file # E27100
J AIC rating (65k & 100k)
J Voltage:
- Single phase 120/240V AC max
- Three phase 240V AC max
J All swing latches and rivets are stainless steel.
J NEMA 3R rated
J G90 galvanized steel
J ANSI 61 paint
4” hub opening
Siemens/Landis & Gyr HD type hubs
External main
service disconnect
Provides safety with quick
convenient access to disconnect
made externally. Eliminates taking
time to remove cover to disconnect.
Siemens
exclusive
feature
QuickConnect™
QuickConnect reduces bussing
connections from many to
one - ensuring a single reliable
connection instead of multiple
connections.
QuickTorque™
Eliminates the need for time
consuming torque readings, this
breakaway nut provides the correct
indication of torque of the Quick-
Connect. When tightened, the
outer head twists off at the proper
torque for connection, leaving a
single nut for future maintenance.
Back View:
Mounting ears
Pullbox opening
Pivot factory installed mounting
6” knockout for aligning a separate ears to minimum or maximum
pullbox if required. position to provide additional
stability when mounting
Siemens
exclusive
feature
QuickRoll™
QuickRoll eliminates the typical metal
brackets for mounting modules to the
wall. Instead of metal scraping metal
QuickRoll allows the module to glide
down the mounting rail via a durable
nylon wheel inside mounting bracket.
Siemens
exclusive
feature
QuickBolt™
QuickBolt eliminates the requirement
to line up mechanical connections -
instead bolts remain retracted until the
openings lineup - allowing the bolts to
protrude through automatically.
Springs push the bolts through and
provide positive pressure to keep bolts
in place while wingnuts are attached
and tightened.
WB1800C WB1800CU 800 OH/UG MXD6 61.19 24.19 11.03 (3) 1/0-500 kcmil KB-2
WB1900Cb WB1900CU 900 OH/UG NXD6 61.19 24.19 11.03 (4) 1/0-500 kcmil KB-3
WB11000C WB11000CU 1000 OH/UG NXD6 61.19 24.19 11.03 (4) 1/0-500 kcmil KB-3
WB11200C WB11200CU 1200 OH/UG NXD6 61.19 24.19 11.03 (4) 1/0-500 kcmil KB-3
a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions.
b 100K and non-standard amperage devices require additional lead time. Please contact sales office for details on lead time.
c 1200 amp maximum feed per side - must be used as a center fed main.
d Lugs not included. Refer to page 3-6 for lug size options. Lug kits available for 750 conductor size.
e All breakers have a non-interchangeable trip unit.
Circuit breaker service entrance modules: 3-phase, 4-wire SN, 240V AC max
WB3800C WB3800CU 800 OH/UG MXD6 61.19 24.19 11.03 (3) 1/0-500 kcmil KB-2
WB3900C 0 WB3900CU 900 OH/UG NXD6 61.19 24.19 11.03 (4) 1/0-500 kcmil KB-3
WB31000C WB31000CU 1000 OH/UG NXD6 61.19 24.19 11.03 (4) 1/0-500 kcmil KB-3
WB31200C WB31200CU 1200 OH/UG NXD6 61.19 24.19 11.03 (4) 1/0-500 kcmil KB-3
/ Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions.
0 100K and non-standard amperage devices require additional lead time. Please contact sales office for details on lead time.
1 1200 amp maximum feed per side - must be used as a center fed main.
2 Lugs not included. Refer to page 3-6 for lug size options. Lug kits available for 750 conductor size.
3 All breakers have a non-interchangeable trip unit.
Wire size 500 kcmil 600 kcmil 750 kcmil 350 kcmil 500 kcmil 600 kcmil 750 kcmil
Amperage # Conductors
15-7/32 15-7/32
7" 4-3/32 7" 4-3/32
3-3/4 3-3/4
11-1/32 11-1/32
2 TYPE "HD" HUB 2 TYPE "HD" HUB
OPENINGS - 4" MAX OPENINGS - 4" MAX
FACTORY INSTALLED FACTORY INSTALLED
COVER PLATES COVER PLATES
8-15/16 8-15/16
39-3/16 39-3/16
27-15/32 TO
BOTTOM OF 27-15/32 TO
QUICK ROLL 19-1/4 BOTTOM OF
BRACKET QUICK ROLL
BRACKET 19-1/4
15-25/32 TO 17-1/4 15-25/32 TO
CROSS BUS CROSS BUS
CENTER CENTER
12-19/32 12-19/32
31-11/32
31-11/32 14-21/32
6
3
18-5/32
27-3/8 TO 29-3/8 TO
PHASE NEUTRAL
STUDS STUDS
72-1/16
72-1/16
1-3/4 NEMA
} STUD SPACING
1-3/4 NEMA
STUD SPACING }
48-21/32 TO 37-1/32 TO
46-21/32 TO BOTTOM OF CROSS BUS
BOTTOM OF QUICK ROLL CENTER
QUICK ROLL BRACKET
BRACKET 29-3/8 TO 27-3/8 TO
NEUTRAL PHASE
35-1/32 TO STUDS STUDS
CROSS BUS
CENTER
28-5/8
WB31400T
WB31400TU
WB31600T
WB31600TU
WB32000T
WB32000TU WB31400B REMOVABLE
WB31400BU
WB31600B BOTTOM 11-29/32
WB31600BU ENDWALL
WB32000B
WB32000BU OPENING
KB-4 KB-5
WB31400TX WB11400TX WB31400BX WB11400BX
WB31600TX WB11600TX WB31600BX WB11600BX
WB32000TX WB12000TX WB32000BX WB12000BX
W B 3 4 0 0 C B D
Amperage
Enclosure Incoming Feed
250
W = Outdoor U = 100K AIC rated unit
300
Blank = 65k AIC rated unit
Device 350
BD = Bus Duct
B = Breaker Phase 400
1000
1200
1400
1600
1800
2000
Power Mod™
Features include:
J QuickSystem™ features
J Factory installed NEMA II studs
J 750 kcmil AL wire options
J 65K AIC standard, 100K AIC available for all models
J Removable blank bottom endwall
J Externally accessible breaker handle with padlock
capability
J Field installable shunt trips
J Large removable ground wire trough with generous
space for grounding conductors
J 400-1200A
J 1200A thru-bus
J UL standard # UL67
J UL file # E27100
J AIC rating (65k & 100k)
J Voltage
- Single phase 120/240V AC Max
- Three phase 240V AC Max
J All swing latches and rivets are stainless steel
J NEMA 3R rated
J G90 galvanized steel
J ANSI 61 paint
J EUSERC drawing numbers 315, 343, and 347
Ground lugs
3 ground lugs included for
bonding additional systems.
Siemens
exclusive
feature
QuickConnect™
QuickConnect reduces bussing
connections from many to
one - ensuring a single reliable
connection instead of multiple
connections.
QuickTorque™
Eliminates the need for time
consuming torque readings, this
breakaway nut provides the correct
indication of torque of the Quick-
Connect. When tightened, the
outer head twists off at the proper
torque for connection, leaving a
single nut for future maintenance.
Back View:
Mounting ears
External main service disconnect
Pivot factory installed mounting
Provides safety with quick convenient ears to minimum or maximum
access to disconnect made externally. position to provide additional
Eliminates taking time to remove cover stability when mounting.
to disconnect.
Siemens
exclusive
feature
QuickRoll™
QuickRoll eliminates the typical metal
brackets for mounting modules to the
wall. Instead of metal scraping metal
QuickRoll allows the module to glide
down the mounting rail via a durable
nylon wheel inside mounting bracket.
Siemens
exclusive
feature
QuickBolt™
QuickBolt eliminates the requirement
to line up mechanical connections -
instead bolts remain retracted until the
openings lineup - allowing the bolts to
protrude through automatically.
Springs push the bolts through and
provide positive pressure to keep bolts
in place while wingnuts are attached
and tightened.
Combination circuit breaker and pullbox modules: 1-phase, 3-wire SN, 120/240V AC max
Meets EUSERC requirements
Dimensions (inches)/ Line side1
Catalog Catalog connections KO
number number Ampere Service Breaker (lugs not drawing
(65k AIC) (100k AIC)0 rating feed type2 Height Width Depth included) no.
1 set of
WEB1400B WEB1400BU 400 UG JXD6 54.88 28.28 13.06 2 studs EB-1
/ Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions.
0 Non standard module. Has longer ordering lead times, contact sales office for additional ordering information.
1 Lugs not included. Refer to page 4-6 for lug size options. Lug kits available for 750 conductor size
2 All breakers have a non-interchangeable trip unit.
Combination circuit breaker and pullbox modules: 3-phase, 4-wire SN, 240V AC max
Meets EUSERC requirements
Dimensions (inches)/ Line side1
Catalog Catalog connections KO
number number Ampere Service Breaker (lugs not drawing
(65k AIC) (100k AIC)0 rating feed type2 Height Width Depth included) no.
1 set of
WEB3400B WEB3400BU 400 UG JXD6 54.88 28.28 13.06 2 studs EB-1
/ Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions.
0 Non standard module. Has longer ordering lead times, contact sales office for additional ordering information.
1 Lugs not included. Refer to page 4-6 for lug size options. Lug kits available for 750 conductor size
2 All breakers have a non-interchangeable trip unit.
Amperage # Conductors
400 1 n/a n/a LK11750N2
2 LK12500N2 n/a n/a
600 2 LK12500N2E n/a LK12750N2
1 Phase
800 2 n/a LK12600N2 LK12750N2
3 LK13500N2 n/a n/a
1200 3 n/a n/a LK13750N2E
4 LK14500N2E n/a n/a
EB-1 EB-2
WEB1400B WEB1400BU WEB1600B WEB1600BU
WEB3400B WEB3400BU WEB3600B WEB3600BU
34-7/32 34-7/32
12-15/32 12-15/32
32 32
} } 59-11/32
59-11/32
44-7/8 TO 44-7/8 TO
BOTTOM OF BOTTOM OF
QUICK ROLL QUICK ROLL
BRACKET BRACKET
33-1/4 TO 33-1/4 TO
CROSS BUS CROSS BUS
CENTER 26-25/32 TO CENTER 26-25/32 TO
PHASE AND PHASE AND
NEUTRAL NEUTRAL
STUDS STUDS
29-1/8
29-1/8
REMOVABLE REMOVABLE
BOTTOM BOTTOM
ENDWALL ENDWALL
OPENING OPENING
3/4 KO 3/4 KO
8-5/8 8-5/8
EB-3 EB-4
WEB1800B WEB1800BU WEB11000B WEB11000BU
WEB3800B WEB3800BU WEB11200B WEB11200BU
WEB31000B WEB31000BU
WEB31200B WEB31200BU
W EB 3 4 0 0 B U
Amperage
Enclosure Incoming Feed
W = Outdoor 400
U = 100K AIC rated unit
Device 600
Blank = 65k AIC rated unit
EB = EUSERC Breaker Phase
800
1 = Single phase Incoming Feed
1200
Power Mod™
Features include:
J QuickSystem™ features
J Standard compression lug capability
J Invertibility: 400-800 Amp devices can be rotated to
accommodate the desired incoming feed direction
J 750 kcmil AL wire options for most models
J 100K AIC standard for all models
J Class T fuse provisions
J Front mounted handle - removes the need for spacers
on the side
J Broad ampacity ratings up to 1200 Amps
J 400-1200A
J 1200A thru-bus
J UL Standard # UL98
J UL file #E25506
J AIC rating (100k AIC)
J Voltage:
- Single phase 120/240V AC max
- Three phase 240V AC max
J All swing latches and rivets are stainless steel
J NEMA 3R rated
J G90 galvanized steel
J ANSI 61 paint
Pullbox Opening
6” knockout for aligning a separate
pullbox if required.
4” hub openings
Siemens/Landis & Gyr HD type hubs
Siemens
exclusive
feature
QuickTorque™
Eliminates the need for time
consuming torque readings, this
breakaway nut provides the correct in-
dication of torque of the QuickConnect.
When tightened, the outer head twists
off at the proper torque for connection,
leaving a single nut for future
maintenance.
Siemens
exclusive
Siemens
feature
exclusive
QuickBolt™ feature
QuickBolt eliminates the requirement
to line up mechanical connections - QuickRoll™
instead bolts remain retracted until the QuickRoll eliminates the typical metal
openings lineup - allowing the bolts to brackets for mounting modules to the
protrude through automatically. wall. Instead of metal scraping metal
Springs push the bolts through and QuickRoll allows the module to glide
provide positive pressure to keep bolts down the mounting rail via a durable
in place while wingnuts are attached nylon wheel inside mounting bracket.
and tightened.
Fusible switch service entrance modules: 1-phase, 3-wire SN, 120/240V AC, 100k AICd
Dimensions (inches)a
Line KO
Catalog Rating Service Fuse side drawing
number amps feed typed Height Width Depth connections no.
2 sets of 2 studs
WS1800CUe 800 OH/UGb T 50.13 15.19 16.31
(lugs not included)
S-2
WS11200BUcf 1200 UG T 50.06 20.22 16.06 (4) 250- 500 kcmil S-3
Fusible switch service entrance modules: 3-phase, 4-wire WN, 240V AC Max., 100k AICd
Dimensions (inches)a
Line KO
Catalog Rating Service Fuse side drawing
number amps feed typed Height Width Depth connections no.
2 sets of 2 studs
WS3800CUe 800 OH/UGb T 50.13 15.19 16.31 S-2
(lugs not included)
a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusion.
b Module is invertible - rotate device to point hub openings to appropriate feed direction.
c 500 kcmil max wire range size.
d Fuses not included.
e Lugs not included. NEMA II stud pattern lugs must be installed by user or utility. Refer to page 5-5 for lug size options.
f Device uses a molded case switch (looks like a breaker). Class T fuses must be installed in conjunction with the molded case switch for proper operation.
Fusible switch
lug kits
Amperage # Conductors
400 1 n/a LK11600N2 LK11750N2
2 LK12500N2 n/a n/a
600 2 LK12500N2 n/a n/a
1 Phase
800 2 n/a LK12600N2 LK12750N2
3 LK13500N2 n/a n/a
1200 3 n/a n/a n/a
4 LK14500*^ n/a n/a
S-1
WS1400CU WS3400CU
WS1600CU WS3600CU
S-2
WS1800CU WS3800CU
16-1/16
18-5/16
50-1/16
35-1/8 TO
BOTTOM OF
23-1/2 TO QUICK ROLL
CROSS BUS BRACKET
CENTER 16-15/16
TO PHASE
15-3/4 TO LUGS
NEUTRAL 15-7/32 TO
LUGS GROUND
LUG
17-23/32 REMOVABLE
BOTTOM ENDWALL
12-23/32
S-3
WS11200BU WS31200BU
W S 3 4 0 0 C B D
Enclosure
Incoming feed
W = Outdoor
Amperage
U = 100K AIC rated unit
Device 400
Incoming feed
Features include:
J QuickSystem™ features
J Factory installed NEMA II studs
J Broad ampacity ratings up to 1200 Amps
J 750kcmil AL wire options
J 100K AIC standard for all models
J Removable blank bottom endwall
J Front mounted handle - removes the need for spacers
on the side
J Class T fuse provisions
J Large removable ground wire trough with generous
space for grounding conductors
J Extra ground lugs in each device
J 400-1200A
J 1200A thru-bus
J UL standard # UL98
J UL file # E25506
J AIC Rating (100k AIC)
J Voltage:
- Single phase 120/240V AC max
- Three phase 240V AC max
J All swing latches and rivets are stainless steel.
J NEMA 3R rated
J G90 galvanized steel
J ANSI 61 paint
J EUSERC drawing numbers 315, 343, and 347
Switch-Pullbox Combinations
www.sea.siemens.com/powermod
Power Mod Switch-Pullbox Combinations
Features
Ground lugs
3 ground lugs included for bonding
additional systems. Mounting ear
Pivot factory installed mounting ears
to minimum or maximum position
Siemens to provide additional stability when
exclusive mounting equipment onto wall.
feature
QuickConnect™
QuickConnect reduces bussing
connections from many to
one ensuring a single reliable
connection instead of multiple
connections.
QuickTorque™
Eliminates the need for time
consuming torque readings, this
breakaway nut provides the correct
indication of torque of the
QuickConnect. When tightened, the
outer head twists off at the proper Siemens
torque for connection, leaving a single exclusive
nut for future maintenance. feature
QuickRoll™
Siemens QuickRoll eliminates the typical metal
exclusive brackets for mounting modules to the
feature wall. Instead of metal scraping metal
QuickBolt™ QuickRoll allows the module to glide
QuickBolt eliminates the requirement down the mounting rail via a durable
to line up mechanical connections- nylon wheel inside mounting bracket.
instead bolts remain retracted until the
openings lineup - allowing the bolts to
protrude through automatically.
Springs push the bolts through and
provide positive pressure to keep bolts
in place while wingnuts are attached
and tightened.
Combination fusible switch and pullbox modules: 1-phase, 3-wire SN, 120/240V AC
Meets EUSERC requirements, 100k AIC b
Dimensions (inches) a Line sidec
connections KO
Catalog Rating Service Fuse (lugs not drawing
number Amps feed type c Height Width Depth included) no.
1 set of
WES1400BU 400 UG T 54.06 29.19 15.94 2 studs ES-1
3 sets of
WES11200BUd 1200 UG T 68.97 34.25 13.47 2 studs ES-3
Combination fusible switch and pullbox modules: 3-phase, 4-wire SN, 240V AC max.
Meets EUSERC requirements, 100k AIC b
Dimensions (inches) a Line sidec
connections KO
Catalog Rating Service Fuse (lugs not drawing
number Amps feed type Height Width Depth included) no.
1 set of
WES3400BU 400 UG T 54.06 29.19 15.94 2 studs ES-1
3 sets of
WES31200BUd 1200 UG T 68.97 34.25 13.47 2 studs ES-3
a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or
hardware protrusions
b Fuses not included
c Lugs not included. NEMA II Stud Pattern lugs must be installed by user or utility. Refer to page 6-5 for Lug size options.
d Device uses a molded case switch (looks like a breaker). Class T fuses must be installed in conjunction with the molded case switch
for proper operation.
ES-1 ES-2
WES1400BU WES3400BU WES1600BU WES3600BU
WES1800BU WES3800BU
13-15/32
26-9/16
44-7/8 TO
BOTTOM OF
} QUICK ROLL
BRACKET
33-1/4 TO
CROSS BUS
26-13/16 TO CENTER
PHASE AND
NEUTRAL STUDS
29-1/8 3-7/8
8-5/8
REMOVABLE BOTTOM
1-1/8 ENDWALL OPENING
ES-3
WES11200BU WES31200BU
W ES 3 4 0 0 B U
Amperage
Device
400
ES = EUSERC Switch Phase
600 Incoming feed
1 = Single Phase
800 B = Bottom feed construction
3 = Three Phase
1200
Power Mod™
Features include:
J QuickSystem™ features
J Standard compression lug capability
J Invertibility: devices can be rotated to accommodate the
desired incoming feed direction
J 750 kcmil AL wire options for most models
J 100K AIC standard for all models
J Broad ampacity ratings from 400 to 1600 Amps
J Line and load capability- service entrance and sub feed
rated
J 400-1600A
J 1200A thru-bus rating
J UL Standard # UL67
J UL file # E27100
J AIC rating (100K AIC)
J Voltage
- Single phase 120/240V AC max
- Three phase 240V AC max
J All swing latches and rivets are stainless steel.
J NEMA 3R rated
J G90 galvanized steel
J ANSI 61 paint
Standard Tapboxes
www.sea.siemens.com/powermod
Power Mod Standard Tapboxes
Features
4” hub openings
Siemens/Landis & Gyr HD type hubs
Invertibility
Devices can be rotated to accommodate
the desired incoming feed direction
Siemens
exclusive
feature
QuickTorque™
Eliminates the need for time
consuming torque readings, this
breakaway nut provides the correct
indication of torque of the
QuickConnect. When tightened, the
outer head twists off at the proper
torque for connection, leaving a single
nut for future maintenance.
Siemens
exclusive Siemens
feature exclusive
QuickBolt™ feature
QuickBolt eliminates the requirement
to line up mechanical connections- QuickRoll™
instead bolts remain retracted until the QuickRoll eliminates the typical metal
openings lineup - allowing the bolts to brackets for mounting modules to the
protrude through automatically. wall. Instead of metal scraping metal
Springs push the bolts through and QuickRoll allows the module to glide
provide positive pressure to keep bolts down the mounting rail via a durable
in place while wingnuts are attached nylon wheel inside mounting bracket.
and tightened.
Tap box modules: 1-phase, 3-wire WN, 120/240V AC, 100k AICc
Dimensions (inches)a
Line side
Catalog Ampere Service connectionse
number rating feedb Height Width Depth (lugs not included) KO drawing no.
Tap box modules: 3-phase, 4-wire SN, 240V AC Max., 100k AICc
Dimensions (inches)a
Line side
Catalog Ampere Service connectionse
number rating feedb Height Width Depth (lugs not included) KO drawing no.
a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions.
b Module is invertible- rotate device to point hub openings to appropriate feed direction.
c QuickConnect not included. If used for load side application an additional coupler must be ordered.
d 1200 Amp maximum feed per side- must be used as a center fed main.
e Lugs not included. Refer to page 7-5 for lug size options.
Amperage # Conductors
400 1 n/a LK11600N2 n/a
2 LK12500N2 n/a n/a
800 2 n/a LK12600N2 LK12750N2
1 Phase
3 LK13500N2 n/a n/a
1200 3 n/a n/a LK13750N2
4 LK14500N2 n/a n/a
1600 5 n/a LK15600N2 LK15750N2
T-1 T-2
WTB1400CU WTB1800CU
WTB3400CU WTB3800CU
T-3 T-4
WTB11200CU WTB11600CU
WTB31200CU WTB31600CU
W TB 3 4 0 0 C U
Device 400
Features include:
J QuickSystem™ features
J Standard compression lug capability
J 750 kcmil AL wire options for most models
J 100K AIC standard for all models
J Broad ampacity ratings from 400 to 1200 Amps
J Removable bottom endwall
J 400-1200A
J 1200 Amp thru-bus rating
J UL Standard #’s UL67
J UL file # E27100
J AIC Rating (100k)
J Voltage
- Single phase 120/240V AC max
- Three phase 240V AC max
J All swing latches and rivets are stainless steel.
J NEMA 3R rated
J G90 galvanized steel
J ANSI 61paint
Ground lugs
3 ground lugs for bonding
additional systems.
Siemens
exclusive
feature
Mounting ear
QuickConnect™ Pivot factory installed mounting ears
QuickConnect reduces bussing to minimum or maximum position
connections from many to to provide additional stability when
one- ensuring a single reliable mounting equipment onto wall.
connection instead of multiple
connections.
QuickTorque™
Eliminates the need for time
consuming torque readings, this
breakaway nut provides the correct
indication of torque of the
QuickConnect. When tightened, the
outer head twists off at the proper
torque for connection, leaving a single
nut for future maintenance.
Siemens
exclusive
Siemens
feature
exclusive
QuickBolt™ feature
QuickBolt eliminates the requirement
to line up mechanical connections- QuickRoll™
instead bolts remain retracted until the QuickRoll eliminates the typical metal
openings lineup - allowing the bolts to brackets for mounting modules to the
protrude through automatically. wall. Instead of metal scraping metal
Springs push the bolts through and QuickRoll allows the module to glide
provide positive pressure to keep bolts down the mounting rail via a durable
in place while wingnuts are attached nylon wheel inside mounting bracket.
and tightened.
s
8-3
Power Mod Tapbox - Pullbox Combinations
Catalog numbers
EUSERC tap box modules: 1-phase, 3-wire SN, incoming, 120/240V ACb
Meets EUSERC requirements, 100k AIC
Dimensions (inches)a Line side
Catalog Ampere Service connectionsc
numberb rating feed Height Width Depth (lugs not included) KO drawing no.
EUSERC tap box modules: 3-phase, 4-wire SN, incoming, 240V AC max.b
Meets EUSERC requirements, 100k AIC
Dimensions (inches)a Line side
Catalog Ampere Service connectionsc
numberb rating feed Height Width Depth (lugs not included) KO drawing no.
a Dimensions shown are representative of outside obx dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions.
b QuickConnect not included. Service entrance rated only.
c Lugs not included. Refer to page 8-5 for lug size options.
Amperage # Conductors
400 1 n/a n/a LK11750N2
2 LK12500N2 n/a n/a
600 2 LK12500N2E n/a LK12750N2
1 Phase
800 2 n/a LK12600N2 LK12750N2
3 LK13500N2 n/a n/a
1200 3 n/a n/a LK13750N2E
4 LK14500N2E n/a n/a
s
8-5
Power Mod Tapbox - Pullbox Combinations
Knockout diagrams
ET-1 ET-2
WET1400BU WET1800BU
WET3400BU WET3800BU
ET-3
WET11200BU
WET31200BU
s
8-7
Catalog Number Logic Example
W ET 3 4 0 0 B U
Enclosure
Incoming Feed
W = Outdoor
U = 100K AIC rated unit
Device Amperage
Features include:
QuickSystem™ features
High-quality, time-proven Landis & Gyr HQ sockets
A line of 3-phase 100 Amp meter stacks to minimize
tenant main cost
Removable back knockout plate to facilitate wiring
225 Amp capability in single and three phase designs
Up to 4 positions with 225 Amp tenant mains, up to
2 positions with 400 Amp tenant mains
Ease of wiring – tenant mains require only a
single bend
-FWFS#ZQBTT.FUFS4UBDLT
www.sea.siemens.com/powermod
1PXFS.PE-FWFS#ZQBTT
Features
High quality
Landis & Gyr HQ lever
bypass block
Siemens
exclusive
feature
QuickConnect™
QuickConnect reduces bussing
connections from many to
one- ensuring a single reliable
connection instead of multiple
connections.
Mounting ear
Pivot factory installed mounting ears
QuickTorque™ to minimum or maximum position
Eliminates the need for time to provide additional stability when
consuming torque readings, this mounting equipment onto wall.
breakaway nut provides the correct
indication of torque of the
QuickConnect. When tightened, the
outer head twists off at the proper
torque for connection, leaving a single
nut for future maintenance.
Siemens
exclusive
feature
QuickBolt™
QuickBolt eliminates the requirement
to line up mechanical connections-
instead bolts remain retracted until the
openings lineup - allowing the bolts to
protrude through automatically.
Springs push the bolts through and
provide positive pressure to keep bolts Siemens
in place while wingnuts are attached exclusive
and tightened. feature
QuickRoll™
Tin plated copper bus straps QuickRoll eliminates the typical metal
brackets for mounting modules to the
wall. Instead of metal scraping metal
QuickRoll allows the module to glide
down the mounting rail via a durable
nylon wheel inside mounting bracket.
Max. Stack
Meter tenant Dimensions (inches)a phasing KO
Catalog positions breaker Breaker Maximum phases/ dwg. Schematic
number per stack (Amps) Provisions AICc Height Width Depth socketse no. no.
1-phase, 3-wire SN, incoming and outgoing, ringless type lever bypass, 5-jaw socketsb
WML11225RJ 1 QS, QSH, 100,000 27.75 19.50 9.00 – L-1 S-1
QSHH, HQS,
WML21225RJ 2 HQSH, QP, 100,000 40.75 19.50 9.00 – L-2 S-1
225
WML31225RJ 3 QPH, HQP, 100,000 49.75 19.50 9.00 – L-3 S-1
MP-T, MP-HT,
WML41225RJ 4 MP-MT 100,000 62.75 19.50 9.00 – L-4 S-1
WML11400RJ d
1 JXD62B400 25,000 44.00 16.31 9.69 – L-5 S-2
400
WML21400RJd 2 Factory inst 25,000 70.38 23.00 9.69 – L-6 S-3
3-phase, 4-wire SN, incoming and 1-phase, 3-wire SN outgoing, ringless type lever bypass, 5-jaw socketsb
WML12225RJ 1 100,000 27.75 19.50 9.00 1-AB L-1 S-4
WML22BC225RJ 2 QS, QSH, 100,000 40.75 19.50 9.00 1-AC, 1-AB L-2 S-6
QSHH, HQS,
WML22CA225RJ 2 100,000 40.75 19.50 9.00 1-AB, 1-BC L-2 S-7
HQSH, QP,
225 1-AB, 1-BC,
WML32225RJ 3 QPH, HQP, 100,000 49.75 19.50 9.00 L-3 S-8
MP-T, MP-HT, 1-CA
MP-MT 2-AB-, 1-BC,
WML42AB225RJ 4 100,000 62.75 19.50 9.00 L-4 S-9
1-CA
1-AB, 2-BC,
WML42BC225RJ 4 100,000 62.75 19.50 9.00 L-4 S-10
1-CA
1-AB, 1-BC,
WML42CA225RJ 4 100,000 62.75 19.50 9.00 L-4 S-11
2-CA
WML12400RJ d
1 JXD62B400 25,000 44.00 16.31 9.69 1-AB L-5 S-12
400
WML22400RJd 2 Factory Inst 25,000 70.38 23.00 9.69 1-AB, 1-BC L-6 S-13
a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions.
b Not for use on 3-phase, 4-wire delta systems
c Max AIC determined by maximum AIC of tenant breakers when used in conjunction with a meter socket. Higher overall ratings may be achieved
through approved series rating combinations.
d Alternate amperage breakers are available. Please see table on right for suffix that needs to be added. Additional lead time may apply. Contact sales
office for details.
e Commerical Stacks are not field phaseable at this time. 1 Meter Position Breaker 2 Meter Positions Breaker
Per Stack Amperage Per Stack Amperage
Add
T1 200A T5 200A/200A
Suffix
T2 250A T6 200A/250A
T3 300A T7 200/300A
T4 350A T8 200/350A
Alternate amperage breakers Add T9 200/400A
Suffix T10 250A/300A
T11 250A/350A
T12 250A/400A
T13 300A/300A
T14 300A/350A
T15 300A/400A
T16 350A/350A
T17 350A/400A
Max.
Meter tenant Dimensions (inches)a KO
Catalog positions breaker Breaker Maximum dwg. Schematic
number per stack (Amps)c provisions AICc Height Width Depth no. no.
3-phase, 4-wire SN, incoming and outgoing, ringless type lever bypass, 7-jaw socketse
WML13100RJb 1 65,000 27.75 23.50 9.00 L-7 S-14
QP, MP-T,
WML23100RJ b
2 QPH, MP-HT, 65,000 40.75 23.50 9.00 L-8 S-14
100
WML33100RJ b
3 HQP, MP-MT 65,000 49.75 23.50 9.00 L-9 S-14
a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions.
b 3-pole breakers only
c Max AIC determined by maximum AIC of tenant breakers when used in conjunction with a meter socket. Higher overall ratings may be achieved
through approved series rating combinations.
d Alternate amperage breakers are available. Please see below table for suffix that needs to be added. Additional lead time may apply. Contact sales
office for details.
e Rated for use with 240/120V Delta systems
L-1 L-2
WML11225RJ WML12225RJ WML21225RJ WML22BC225RJ
WML22AB225RJ WML22CA225RJ
L-3
WML31225RJ WML32225RJ
L-5
WML11400RJ WML13400RJ
WML12400RJ
L-4
WML41225RJ WML42BC225RJ
WML42AB225RJ WML42CA225RJ
L-6
WML21400RJ WML23400RJ
WML22400RJ
L-7 L-8
WML13100RJ WML23100RJ
L-9 L-10
WML33100RJ WML43100RJ
L-11 L-12
WML13225RJ WML23225RJ
L-14
L-13
WML43225RJ
WML33225RJ
EQUIPMENT GROUND
A B
NEUTRAL
(POTENTIAL JAW)
NEUTRAL
B A (POTENTIAL JAW) NEUTRAL
(POTENTIAL JAW)
A A
N N
B B
NEUTRAL
LUGS
A A
N N
Equip. B B
Grd.
B A
A B A B
S-2
WML11400RJ
WML11400RJ
B A
S-3
A A
N N WML21400RJ
B B WML21400RJ
B A
Equip. B C C A
Grd.
A A A A
N N N N
B B B B
S-1 C C C C
WML41225RJ
WMLX1225RJ
NEUTRAL NEUTRAL
(POTENTIAL JAW) (POTENTIAL JAW)
C A B A
Equip. Equip.
Grd. Grd.
S-5 S-6
NEUTRAL
(POTENTIAL JAW)
WML22AB225RJ
WML22AB225RJ WML22BC225RJ
WML22BC225RJ
B A
A A
N N
B B
C C
Equip.
Grd.
B A
S-4
WML12225RJ
WML12225RJ
C A
C A
B A
B A
B A
A A
A A N N
A A N N
N N B B
B B C C
B B C C
C C
NEUTRAL NEUTRAL
NEUTRAL (POTENTIAL JAW)
(POTENTIAL JAW)
(POTENTIAL JAW) B C
B C
B C
NEUTRAL
(POTENTIAL JAW)
A A
N N
B C C A
B B
C C
Equip.
Grd.
C A C A A B
S-12
WML12400RJ
WML12400RJ
B A B A
A A A A
N N N N
B B B B
C C C C
NEUTRAL
NEUTRAL NEUTRAL (POTENTIAL JAW)
(POTENTIAL JAW) (POTENTIAL JAW)
B C B C
Equip. Equip.
Grd. Grd. A A
N N
B B
C C
S-10 S-11
WML42BC225RJ
WML42BC225RJ WML42CA225RJ
WML42CA225RJ
Equip.
Grd.
S-15
WML13400RJ
WML13400RJ
HIGH LEG FOR 3Ø,
4 WIRE DELTA SYSTEM
(ALL BRANCH POSITIONS)
EQUIPMENT GROUND A
B
C NEUTRAL
(POTENTIAL JAW)
C B
NEUTRAL
(POTENTIAL JAW) A
B
C HIGH LEG FOR 3Ø, EQUIPMENT GROUND
4 WIRE DELTA SYSTEM
(ALL BRANCH POSITIONS)
NEUTRAL
LUGS NEUTRAL
(POTENTIAL JAW)
A B C
A A
N N HIGH LEG FOR 3Ø,
B B 4 WIRE DELTA SYSTEM
C C
A
B
C
A C
A A
N N
B B
C C
NEUTRAL
LUGS
A A
N N
B B
S-13 C C
WML22400RJ A
WML22400RJ B A B C
C
HIGH LEG FOR 3Ø,
4 WIRE DELTA SYSTEM
Equip.
Grd.
S-14 S-16
WML43100RJ WML23400RJ
WMLX3100RJ WMLX3225RJ WML23400RJ
W M L 1 3 100 R J
Phase
1 = Single phase
3 = 3 phase
Features include:
QuickSystem™ features
Exclusive Landis & Gyr K4, K5, & K7 meter sockets
1 position K4, K5, K7 modules with 400 & 600 Amp
tenant mains
2 position K7 module with 400 Amp tenant main
Space saving design
,#BTF.FUFS4UBDLT
www.sea.siemens.com/powermod
1PXFS.PE,#BTF
Features
High quality
Landis & Gyr bolt
on meter base
External main
service disconnect
Provides safety with quick
convenient access to disconnect
made externally. Eliminates taking
time to remove cover to disconnect
Siemens
exclusive
feature
QuickConnect™
QuickConnect reduces bussing
connections from many to
one- ensuring a single reliable
connection instead of multiple
connections.
Mounting ear
Pivot factory installed mounting ears
to minimum or maximum position
QuickTorque™
to provide additional stability when
Eliminates the need for time
mounting equipment onto wall.
consuming torque readings,
this breakaway nut provides the
correct indication of torque of the
QuickConnect. When tightened, the
outer head twists off at the proper
torque for connection, leaving a
single nut for future maintenance.
Siemens
exclusive
feature
QuickBolt™
QuickBolt eliminates the requirement
to line up mechanical connections-
instead bolts remain retracted until the
openings lineup - allowing the bolts to
protrude through automatically.
Springs push the bolts through and
provide positive pressure to keep bolts Siemens
in place while wingnuts are attached exclusive
and tightened. feature
QuickRoll™
QuickRoll eliminates the typical metal
brackets for mounting modules to the
wall. Instead of metal scraping metal
QuickRoll allows the module to glide
down the mounting rail via a durable
nylon wheel inside mounting bracket.
JXD62B400
WMK12400RJd 1 400
Factory Inst.
54.00 19.25 10.00 AB KB-2 S-2
KB-2
WMK12400RJ WMK13600RJ
WMK13400RJ
KB-1
WMK11400R
WMK11600R Schematics NEUTRAL
(POTENTIAL JAW)
A A
N N
B B
C C
A A
Equip.
N N Grd.
B B
A B
S-2
Equip.
Grd. WMK12400RJ
WMK12400RJ
A B
S-1
WMK11400R WMK11600R
WMK11400R HIGH LEG FOR 3Ø,
4 WIRE DELTA SYSTEM
EQUIPMENT GROUND
WMK11600R
(ALL BRANCH POSITIONS)
NEUTRAL
(POTENTIAL JAW)
A B C
NEUTRAL
(POTENTIAL JAW)
NEUTRAL
LUGS
A A A A
N N N N
B B
B B C C
C C
A B C
W M K 1 1 400 R J
Positions
Phase
Cover
1 = Single phase
R = Ringless
2 = 3-phase in/single out
BLANK = Ring Type
3 = 3-phase
1PXFS.PEt
Features include:
QuickSystem™ features
High-quality, time-proven Siemens SMM switchboard
meter socket
Removable back knockout plate to facilitate wiring
225 Amp capability in single and three phase designs
Up to 3 positions with 225 Amp tenant mains
Wiring flexibility - tenant mains require only a single
bend
Three phase input, single phase output modules
In line wiring: side knockouts allow wiring for adjacent
units to pass through
5FTU#MPDL#ZQBTT.FUFS4UBDLT
www.sea.siemens.com/powermod
1PXFS.PE5FTU#MPDL#ZQBTT
Features
Siemens
exclusive
feature
QuickConnect™
QuickConnect reduces bussing
connections from many to
one- ensuring a single reliable
connection instead of multiple
connections.
Mounting ear
Pivot factory installed mounting ears
to minimum or maximum position
QuickTorque™ to provide additional stability when
Eliminates the need for time mounting equipment onto wall.
consuming torque readings, this
breakaway nut provides the correct
indication of torque of the Quick-
Connect. When tightened, the outer
head twists off at the proper torque
for connection, leaving a single nut
for future maintenance.
Siemens
exclusive
feature
QuickBolt™
QuickBolt eliminates the requirement
to line up mechanical connections-
instead bolts remain retracted until the
openings lineup - allowing the bolts to
protrude through automatically.
Springs push the bolts through and
provide positive pressure to keep bolts Siemens
in place while wingnuts are attached exclusive
and tightened. feature
QuickRoll™
QuickRoll eliminates the typical metal
brackets for mounting modules to the
wall. Instead of metal scraping metal
QuickRoll allows the module to glide
down the mounting rail via a durable
nylon wheel inside mounting bracket.
1-phase, 3-wire SN, incoming and outgoing, test block bpass, 4-jaw socketsb
WMT11225 1 225 QS, QSH, QSHH, 40.50 21.50 9.00 — TB-1 S-1
HQS, HQSH, QP,
WMT21225 2 225 46.00 21.50 9.00 — TB-2 S-2
QPH, HQP, MP-T,
WMT31225 3 225 MP-HT, MP-MT 65.50 21.50 9.00 — TB-3 S-3
3-phase, 4-wire SN, incoming and 1-phase, 3-wire SN outgoing, test block bypass, 5-jaw socketsb e
WMT12225J 1 225 40.50 21.50 9.00 AB TB-1 S-4
WMT22AB225J 2 225 QS, QSH, QSHH, 46.00 21.50 9.00 1-BC, 1-CA TB-2 S-5
HQS, HQSH, QP,
WMT22BC225J 2 225 46.00 21.50 9.00 1-AB, 1-CA TB-2 S-6
QPH, HQP, MP-T,
WMT22CA225J 2 225 MP-HT, MP-MT 46.00 21.50 9.00 1-AB, 1-BC TB-2 S-7
1-AB, 1-BC,
WMT32225J 3 225 65.50 21.50 9.00 TB-3 S-8
1-CA
3-phase, 4-wire SN, incoming and outgoing, test block bypass, 7-jaw socketsd
WMT13225J 1 225 40.50 25.50 9.00 — TB-4 S-9
QJ2, QJH2,
WMT23225J 2 225 QJ2H, HQJ2H, 46.00 25.50 9.00 — TB-5 S-10
MQ, MQH, MQL
WMT33225J 3 225 65.50 25.50 9.00 — TB-6 S-11
a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions.
b Not for use on 3-phase,4-wire delta systems.
c Max AIC determined by maximum AIC of tenant breakers when used in conjunction with a meter socket.
d Rated for use with 240/120V Delta systems.
e Commercial Stacks are not field phaseable.
TB-1 TB-2
WMT12225J WMT22AB225J WMT22CA225J
WMT22BC225J
TB-3 TB-4
WMT31225J WMT32225J WMT13225J
TB-5 TB-6
WMT23225J WMT33225J
Schematics
L L L L
I O I O
N A N A
E D E D
B A
L L L L L L L L
I O I O I O I O
N A N A N A N A
E D E D E D E D
B A B A
A A A A A A
N N N N N N
B B B B B B
B A B A B A
Equip.
B C C A
Grd.
L L L L
I O I O
N A N A
E D E D A A A A
N N N N
B B B B
C C C C
B A
S-4 Equip.
Grd.
Equip.
Grd.
WMT12225J L
I
L
O
L
I
L
O
L
I
L
O
L
I
L
O
WMT12225J N
E
A
D
N
E
A
D
N
E
A
D
N
E
A
D
C A B A
S-5 S-6
WMT22AB225J WMT22BC225J
WMT22AB225J WMT22BC225J
NEUTRAL
(POTENTIAL JAW) NEUTRAL (POTENTIAL JAW)
L L L L A A
I O I O N N
N A N A
E D E D B B
C C
B A
L L L L
I O I O
N A N A A
E D E D
B
C
Equip.
Grd.
L L L L
C A
I O I O
N
E
A
D
N
E
A
D S-9
WMT13225J
WMT13225J
B C
L L L L
S-7 I
N
O
A
I
N
O
A
WMT22CA225J E D E D
WMT22CA225J
B A
Equip. A
Grd. B
L L L L C
I O I O
N A N A
E D E D
B C
NEUTRAL (POTENTIAL JAW)
WMT32225J
I O I O I O I O I O I O
N A N A N A N A N A N A
E D E D E D E D E D E D
WMT32225J
A A
B B
C C
A A A A
N N N N
B B B B
C C C C
Equip. Equip. L L L L L L
L L L L L L
Grd. I O I O I O Grd. I O I O I O
N A N A N A N A N A N A
E D E D E D E D E D E D
A A
B B
C C
S-10 S-11
WMT23225J WMT33225J
WMT23225J WMT33225J
W M T 1 2 225 J
Positions
Amperage
WMT 1 5th jaw
225
WMT = N3R Test Block Bypass Stack 2a
J = 5th jaw installed (7 jaws for 3-phase in/out)
3
Phase
1 = Single phase
3 = 3-phase
For lugs:
UL486A/B
750 kcmil maximum wire size (may vary by catalog
number)
Tin plated aluminum extrusions
For QS Breaker:
UL489
100-225 Amps
300 kcmil maximum wire size
"DDFTTPSJFT
www.sea.siemens.com/powermod
Power Mod lug kits
Lug selector catalog numbers
Lug kits are available to meet the growing demand for multiple
wiring configurations using aluminum and copper conductors in
today’s market. PowerModTM offers a variety of lug configurations
for every breaker, switch, and tap box module. Standard circuit
breaker mains (type WB) include lugs for 1200 Amp and below
models. All other modules come with factory studs and require
lugs to be field installed. The chart below will help you in
identifying the proper lug kit based on your conductor size.
For example, if you have (1) 1200 single phase tapbox, and are
running (3) 750 kcmil wires per phase, you would order (1)
LK13750N2
Amperage # Conductors
400 1 n/a LK11600N2 n/a n/a n/a LK11750*
2 LK12500N2 n/a n/a LK12500*^ n/a n/a
600 2 n/a n/a n/a LK12500*^ n/a n/a
800 2 n/a LK12600N2 LK12750N2 n/a n/a n/a
1 Phase
3 LK13500N2 n/a n/a LK13500*^ n/a LK13750*
1200 3 n/a n/a LK13750N2 n/a n/a LK13750*
4 LK14500N2 n/a n/a LK14500*^ n/a n/a
1600 5 n/a LK15600N2 LK15750N2 n/a LK15600N2 LK15750N2
2000 6 n/a n/a n/a n/a n/a LK16750N2
350 500 600 750 500 600 750 500 600 750
n/a n/a LK11600N2 n/a n/a LK11600N2 LK11750N2 n/a n/a LK11750N2
LK12350N2 n/a n/a n/a LK12500N2 n/a n/a LK12500N2 n/a n/a
LK12350N2 n/a n/a n/a LK12500N2 n/a n/a LK12500N2E n/a LK12750N2
n/a n/a LK12600N2 LK12750N2 n/a LK12600N2 LK12750N2 n/a LK12600N2 LK12750N2
n/a LK13500N2 n/a n/a LK13500N2 n/a n/a LK13500N2 n/a n/a
n/a n/a n/a LK13750N2 n/a n/a n/a n/a n/a LK13750N2E
n/a LK14500N2 n/a n/a LK14500*^ n/a n/a LK14500N2E n/a n/a
n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a
n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a
n/a n/a LK31600N2 n/a n/a LK31600N2 LK31750N2 n/a n/a LK31750N2
LK32350N2 n/a n/a n/a LK32500N2 n/a n/a LK32500N2 n/a n/a
LK32350N2 n/a n/a n/a LK32500N2 n/a n/a LK32500N2E n/a LK32750N2
n/a n/a LK32600N2 LK32750N2 n/a LK32600N2 LK32750N2 n/a LK32600N2 LK32750N2
n/a LK33500N2 n/a n/a LK33500N2 n/a n/a LK33500N2 n/a n/a
n/a n/a n/a LK33750N2 n/a n/a n/a n/a n/a LK33750N2E
n/a LK34500N2 n/a n/a LK34500*^ n/a n/a LK34500N2E n/a n/a
n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a
n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a
12-3
Accessories and replacement parts
Catalog numbers
LLP600 Lug Landing Pad for 400-600 Amp standard Breaker modules (new only)
LLP1200 Lug Landing Pad for 800-1200 Amp standard breaker modules (new only)
Dimensions (inches) a
Catalog number Description
Height Length Width
a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions.
ECMFH Horn bypass kit for new Residential Meter Stacks (1 position)
ECMFBM1 Breaker mounting replacement for 125 Amp Power Mod Residential Meter Stacks
ECMFBM2 Breaker Mounting replacement for 225 Amp Power Mod Residential Meter Stacks
ECMFMC Meter cover replacement for ring type Power Mod Residential Meter stacks
ECMFMCR Meter cover replacement for Power Mod Ringless Residential Meter stacks
ECMFPK Loose parts replacement kit (parts shipped loose include labels and hardware, QuickConnect™ not included)
ECMFCS Cover screw replacement (quantity 10) for Power Mod Meter Stacks
ECMFC Bottom pull cover replacement for Power Mod Residential Meter Stacks
12-5
Accessories and replacement parts
Catalog numbers
Ground/neutral Bar kit for 125 Amp Residential Stacks, ground only for 225 Amp
ECMFGN125
Residential Stacks
ECMMBCM Power Mod plastic breaker cover for main breaker units
WMEP b
End closure plate
EC56854 c
2" HD type hub
12-7
Accessories
Catalog numbers
EUSERC compliant pullbox modules: 1-phase, 3-wire SN, incoming , 120/240V AC max.
Dimensions (inches)a KO
Catalog Ampere Withstand Service Line terminal lugs no. drawing
number rating ratingb feed and size per line and netural Height Width Depth no.
EUSERC compliant pullbox modules: 3-phase, 4-wire SN, incoming, 240V AC max.
Dimensions (inches)a KO
Catalog Ampere Withstand Service Line terminal lugs no. drawing
number rating ratingb feed and size per line and netural Height Width Depth no.
a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions.
b Devices rated for 22,000. 65,000 rating requires cables to be tied together. Please see instructions with pullbox for details.
W W
QuickConnect (QC)
Tap Stacksa
Tap stacks save space by connecting Siemens Sentron Busway
directly to specially designed Siemens circuit breaker, switch or
tapbox modules. Common modules are listed above. Tap stacks
require end-user to purchase additional QuickConnect coupler and
are for indoor use on end-feed applications only.
a Tap stacks are produced with the busway. Contact sales office for more
information.
Common Bus Duct Units: 3-phase, 4-wire SN, incoming, 240V AC max.be
Dimensions (Inches)a
Ampere Mechanism
Catalog number ratingd Height Width Depth type AIC ratingc KO Diagram
a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions.
b All devices are build to order. Tap stack and QuickConnect sold separately.
c 100K AIC breaker units available - contact sales office for more information.
d Alternate amperages for breaker modules available. Contact sales office for more information.
e Single phase bus duct devices are available. Contact sales office for more information.
12-9
Bus Duct
Knockout diagrams
BD-1 BD-2
MC44BD MC64BD
BD-3 BD-4
MC84BD MC104BD
BD-6
MS44UBD
BD-5 BD-7
MC124BD MS64UBD
BD-8
MS84UBD
12-11
$JSDVJU#SFBLFST
Catalog numbers
10K AIC 22K AIC 42K AIC 65K AIC 100K AIC
Amperage Siemens Murray Siemens Murray Siemens Murray Siemens Murray Siemens Murray
Type QP Type MP-T Type QPH Type MP-HT - - Type HQP Type MP-MT - -
For use in 125 Amp and 225 Amp single phase output WMM, WML, WMT meter stacks
60 Q260 MP260 Q260H MP260KH use HQP use MP-MT Q260HH MP260KM use HQSH/ use HQSH/
70 Q270 MP270 Q270H MP270KH use HQP use MP-MT Q270HH MP270KM use HQSH/ use HQSH/
80 Q280 MP280 Q280H MP280KH use HQP use MP-MT Q280HH MP280KM use HQSH/ use HQSH/
90 Q290 MP290 Q290H MP290KH use HQP use MP-MT Q290HH MP290KM use HQSH/ use HQSH/
100 Q2100 MP2100 Q2100H MP2100KH use HQP use MP-MT Q2100HH MP2100KM use HQSH /
use HQSH/
110 Q2110 MP2110 Q2110H MP2110KH use HQP use MP-MT Q2110HH MP2110KM use HQSH /
use HQSH/
125 Q2125 MP2125 Q2125H MP2125KH use HQP use MP-MT Q2125HH MP2125KM use HQSH /
use HQSH/
For use in 100 Amp, 3- phase output WML meter stacks only
60 Q360 MP360 Q360H MP360KH use HQP use MP-MT Q360HH MP360KM use HQJ2H0 use HQJ2H0
70 Q370 MP370 Q370H MP370KH use HQP use MP-MT Q370HH MP370KM use HQJ2H0 use HQJ2H0
80 Q380 MP380 Q380H MP380KH use HQP use MP-MT Q380HH MP380KM use HQJ2H0 use HQJ2H0
90 Q390 MP390 Q390H MP390KH use HQP use MP-MT Q390HH MP390KM use HQJ2H0 use HQJ2H0
100 Q3100 MP3100 Q3100H MP3100KH use HQP use MP-MT Q3100HH MP3100KM use HQJ2H 0
use HQJ2H0
For use in 225 Amp single phase output WMM, WML, WMT meter stacks
Type QS1 - Type QSH1 - Type QHS1 - Type HQS1 - Type HQSH1 -
100 QS2100 use QS QS2100H use QSH QSH2100 use QHS QS2100HH use HQS HQS2100H use HQSH
125 QS2125 use QS QS2125H use QSH QSH2125 use QHS QS2125HH use HQS HQS2125H use HQSH
150 QS2150 use QS QS2150H use QSH QSH2150 use QHS QS2150HH use HQS HQS2150H use HQSH
200 QS2200 use QS QS2200H use QSH QSH2200 use QHS QS2200HH use HQS HQS2200H use HQSH
225 QS2225 use QS QS2225H use QSH QSH2225 use QHS QS2225HH use HQS HQS2225H use HQSH
For use in 225 Amp 3-phase output WML & WMT meter stacks only
Type QJ2 Type MQ Type QJH2 Type MQH Type QJ2H Type MQL - - Type HQJ2H -
100 QJ23B100 MQJ3100 QJH23B100 MQJ3100KH QJ23B100H MQJ3100KL use HQJ2H use HQJ2H HQJ23B100H use HQJ2H
110 QJ23B110 MQJ3110 QJH23B110 MQJ3110KH QJ23B110H MQJ3110KL use HQJ2H use HQJ2H HQJ23B110H use HQJ2H
125 QJ23B125 MQJ3125 QJH23B125 MQJ3125KH QJ23B125H MQJ3125KL use HQJ2H use HQJ2H HQJ23B125H use HQJ2H
150 QJ23B150 MQJ3150 QJH23B150 MQJ3150KH QJ23B150H MQJ3150KL use HQJ2H use HQJ2H HQJ23B150H use HQJ2H
175 QJ23B175 MQJ3175 QJH23B175 MQJ3175KH QJ23B175H MQJ3175KL use HQJ2H use HQJ2H HQJ23B175H use HQJ2H
200 QJ23B200 MQJ3200 QJH23B200 MQJ3200KH QJ23B200H MQJ3200KL use HQJ2H use HQJ2H HQJ23B200H use HQJ2H
225 QJ23B225 MQJ3225 QJH23B225 MQJ3225KH QJ23B225H MQJ3225KL use HQJ2H use HQJ2H HQJ23B225H use HQJ2H
/ HQSH breakers require the use of 225 Amp WMM meter stacks.
0 HQJ2H breakers require the use of 225 Amp 3-phase WML meter stacks.
1 QS series rates with Murray circuit breakers.
(FUUIFIJHIFTUTUBOEBSE
Siemens is proud to offer one of the highest quality and broadest and most flexible load
center lines in the industry. From single family to multi-family applications, Siemens can
offer a high quality, labor saving load center for your application.
www.sea.siemens.com/powermod
names of Siemens AG or supplier companies whose use by Answers for industry.
third parties for their own purposes could violate the rights
of the owners.