Вы находитесь на странице: 1из 5

INSPECTION SHEET 1

A. General Information

Reference Drawings of the Structure

 Tower Name or Identification No:

 Location: ; Year built:

 Its Primary function:

 General Dimensions:

Plan area (m x m); height (m)

 Type of foundation:

Pinned Fixed
Height of concrete foundation above GL (m)

 Materials:

Type of steel:
Type of bolts/rivets:

 Environmental Conditions:

Annual temperature: max min

Corrosivity: mild severe very severe

 Past Painting/Repair
If done, when last painted (date)
Type of repair (if any)

 Past Inspection report


Available YesDated
No

/conversion/tmp/scratch/433769429.doc Page 1 of 5
MEMBERS INSPECTION SHEET 2

MEMBER NO.

 From Joint No. To Length


(mm)

Bottom Joint Elevation (m)

Section Type Angle I beam


Size Size

 Corrosion of Metal

Surface rust Yes No


Loss of thickness Yes No

If yes Extent of Damage (m2)


Approx. area
Reduce thickness (mm)

loss of material Yes No

If yes remaining section (net) size


(Provide sketch of net section shape)

 Fracture & Damage

Not visible Visible Location


Severity (1-5)
 Deformation & Distortion

No Yes
If yes Specify Type Buckled (Bent-out) Twisted (warped)

Magnitude Obvious
Strong
Severe
 Other observations, if any

Specify:

/conversion/tmp/scratch/433769429.doc Page 2 of 5
JOINTS INSPECTION SHEET 3

JOINT NO. Elevation (m)

No. of plates connected to it

(Fill the information on inspection sheet # 4 for each plate)

 Bolts (for connections without plates) Diameter (mm)

Missing bolts, damaged, or loose No Yes


If yes, No. of Bolts

Corrosion of bolts No Yes


If yes, Specify Type Surface rust
Loss of material

/conversion/tmp/scratch/433769429.doc Page 3 of 5
PLATE INSPECTION SHEET 4

PLATE NO. Thickness (mm)

Total No. of bolts connected to it


Total No. of welds connected to it

 Paint

Defected or damaged Yes No


If yes
Defect Type
Extent of damage / defect (m2)
Approx. area
Severity of damage / defect (1-5)

 Corrosion of Metal

Surface rust Yes No


Loss of thickness Yes No
If yes extent of damage (m2)
Reduced thickness (mm)

Loss of material Yes No


If yes remaining section (net) size
(Provide Sketch of net section shape)

 Fracture & Damage

Not visible Visible Location


Severity (1-5)
 Deformation & Distortion

No Yes
If yes, Specify Type Buckled (Bent-out)
Twisted (Warped)
Magnitude Obvious
Strong
Serve

 Bolts Diameter (mm)

Missing bolts or damaged or loose No Yes


If yes No. of Bolts

Corrosion of bolts No Yes


If yes Surface rust
Loss of material Reduced diameter (m)

/conversion/tmp/scratch/433769429.doc Page 4 of 5
APPENDIX “B”

/conversion/tmp/scratch/433769429.doc Page 5 of 5