1 SCHEDULE OF REINFORCEMENT

BAR
MARK
DESCRIPTION BAR SHAPE NOTES
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN METERS
1 Y12 AT 150 UNLESS OTHERWISE MENTIONED. ONLY WRITTEN DIMENSIONS TO
BE FOLLOWED.
1a Y10 AT 150 2. GRADE OF CONCRETE SHALL BE AS FOLLOWS:
PRECAST GIRDER : M50
2 Y12 AT 150 CAST-IN-SITU DECK SLAB & DIAPHRAGMS : M45.

VARIES 3. ALL REINFORCEMENT BARS SHALL BE H.Y.S.D BARS (GRADE


3 Y12 AT 150 DESIGNATION Fe 500) CONFORMING TO IS:1786. WITH LATEST
AMENDMENT.
4. CLEAR COVER TO OUTERMOST STEEL SHALL BE AS FOLLOWS:
4 Y16 AT 150
GIRDER & DIAPHRAGMS : 35mm
DECK SLAB : 25mm
4a Y12 AT 150 5. JACK LOCATION SHOULD BE PERMANENTLY MARKED / ETCHED ON
VARIES
PIERCAP / END DIAPHRAGM.

4b Y10 AT 150 6. REFER SEPARATE DRAWING FOR MISCELLANEOUS DETAILS.


7. DURING LIFTING OPERATION ALL FOUR JACKS UNDER THE END
DIAPHRAGM INLINE WITH BEARING SHALL BE OPERATED
5 Y10 AT 150
SIMULTANEOUSLY USING SINGLE OPEARATING CONSOLE.
GROUPING THE PUMP AND CONTROL SYSTEMS SO AS TO ENSURE
6 Y10 AT 150
REACTION ON ALL JACKS ARE EQUAL AT ALL TIME.

6a Y10 AT 150 VARIES 8. MINIMUM LAP LENGTH SHALL BE AS PER CLAUSE 15.9.6.6 OF IRS :
CONCRETE BRIDGE CODE THE DEVELOPMENT LENGTH SHALL NOT

6b Y10 AT 150 BE LESS THAN 41 TIMES THE DIA OF BAR.

REFERENCE DWG
7 Y12 AT 150
1. 303-W1/RB/0101 & - GENERAL NOTES (SH1 & SH2)
303-W1/RB/0102
7a 2 - Y12
2. 303-W1/RB/0104 & - MISCELLANEOUS DETAILS FOR PSC SUPER
303-W1/RB/0105 STRUCTURES (SH1 & SH2)
8 2-Y12
3. 303-W1/RB/0632 - NUM. DETAILS OF SUPER STRUCTURE
4. 303-W1/RB/0634 - REINFORCEMENT DETAILS OF DECK SLAB
8a 2-Y12
5. 303-W1/RB/0635 - REINFORCEMENT DETAILS OF CROSS GIRDER
6. 303-W1/RB/0636 - ANCHORAGE DETAILS OF GIRDER
9 Y12 AT 150
1 7. 303-W1/RB/0637 - SUPER STRUCTURE FOR SPAN 15.50m - CABLE
PROFILE DETAILS
10 2-Y12
ABBREVIATIONS
11 2-Y12
EJ - EXPANSION JOINT
TYP - TYPICAL
11a 2-Y12 CL - CENTER LINE
THK - THICKNESS
11b 2-Y12
LEGEND
11c 2-Y12
TOP REINFORCEMENT

12 2-Y12 BOTTOM REINFORCEMENT

13 2-Y12

13a 2-Y12

13b 2-Y12

14 6-Y16

15 2-Y16

1 16 2-Y16

- BAR MARK 14 , 15 , 16 TO BE EXTENDED Ld


DISTANCE AS SHOWN FROM THE INSIDE FACE OF
BEARINGS. THESE BARS CAN BE LOCALLY BENT
TO AVOID INTERFERENCE DURING PRESTRESSING.

DESIGN DOC. REFER : DOC/CTP-303/DGN/BR/0207

THIS DRAWING IS ONLY APPLICABLE FOR


FOLLOWING BRIDGES.
TYPE OF BRIDGE
SL.NO
BRIDGE NO.

1 UB MAJ MTC - 19

2 UB MAJ MTC - 27

3 UB MAJ MTC - 55

4 UB MAJ MTC - 90

SCALE DESIGN CONSULTANT CONTRACTOR PMC JV OF SYSTRA OWNER PROJECT JOB NO: O18087 STATUS:
DEDICATED FREIGHT TITLE W
MVA CONSULTING
L&T Infra Engineering CORRIDOR DRG. NO. 303-W1/RB/0633/1 DRG. SIZE. A1
LARSEN & TOUBRO LIMITED (INDIA) PVT. LTD. DEDICATED FREIGHT CORRIDOR-EASTERN SUPER STRUCTURE FOR SPAN 15.50m -
AND SYSTRA S.A., CORPORATION OF
AS SHOWN CORRIDOR KHURJA TO PILKHANI DATE : 090719 DRAWN RDL
1 090719 ISSUED AS GOOD FOR CONSTRUCTION AS PER PMC LETTER NO. 2294 GFC RDL SPM SSM FRANCE INDIA LTD. REINFORCEMENT DETAILS OF GIRDER
APPROVED
0 020519 ISSUED AS GOOD FOR CONSTRUCTION AS PER PMC LETTER NO. 1607 GFC SLT Sd\- SPM Sd\- SSM Sd\-
CONTRACT PACKAGE - 303 DESIGN CHECKED APPROVED
APPROVED NAME SIGN APPROVED NAME SIGN APPROVED NAME SIGN
SPM Sd\- KGN Sd\- SSM Sd\-