Академический Документы
Профессиональный Документы
Культура Документы
on
Thermal Energy Management
o Introduction
o Tested Samples
o Conclusions
Introduction
1.4
1.2 Uptake
Stability Time/1000 [min]
Uptake [kg/kgads]
0.8
0.6
0.4
0.2
0
Prediction of kinetics and Adsorption isotherms
A m P
xeq = xmax exp − A = − RT ln
E
Ps
Kinetics Prediction of different Samples
Adsorption Isotherms
1.4
Maxsorb Eurocarb ATO
Eurocarb HDLC Chemviron SRD 12005
1.2
1
Uptake [kg/kg]
0.8
0.6
0.4
0.2
Isotherm of carbon samples at 25 °C
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
P/ps [-]
CFD Model of Plate Heat Exchanger
Governing Equations
(
∂ ερ g + ρ b x )
+ ∇ • ρ gug = 0 ( ) Mass Balance
∂t
∂T ∂x
(ρC )eff
∂t
( )
+ ρ g C pg u g ⋅ ∇T = ∇ ⋅ λeff ∇T + ρb ∆H
∂t Energy Balance
K
ug = − ∇P
µg Momentum Balance (Darcy module)
Physical properties
o d 2pε 3 Permeability
K=
2
150( 1 − ε )
Effective density
o ρ b = ( 1 − ε )ρ s
2λs + λ g − 2ε (λs − λg )
o λeff = λs Effective Thermal conductivity
2λs + λ g + ε (λs − λ g )
1000 1
0.8
0.6
Desorption
2 0.4
3
100 0.2
0.1
Pressure [mbar]
Preheating 0.01
10 Precooling
1 4
Adsorption
1
0.1
35[°C] Maxsorb
0.01
-15 0 15 30 45 60 75 90
Bed Temperature [°° C]
Adsorbent Temperature and Uptake Distribution
0.045
0.04
Uptake [kg/kgads]
0.035
0.03
0.025
0.02
0.015
0 5 10 15 20
Distance from adsorbent Upper Surface [mm]
Maxsorb adsorbent Temperature and uptake in adsorbent layer after 160 sec
Uptake of initially dry bed with packing thickness
Temperature distribution of initially dry bed at various packing thickness
Comparing different samples in real chiller operation (initial uptake wmin>0.0)
Conclusions