700PTP-1 Pneumatic Features: • (2) 1/8 in NPT male quick


Test Pump • Pump can be easily cleaned connects
Description: The Fluke- without disassembly. • 1/8 NPT female to 1/4 in BSP
700PTP-1 pneumatic test pump • The vernier can be used as female
is capable of supplying pres- a stand-alone low pressure • Seal Kit
Use Fluke sures up to 600 psi, 40 bar. calibration source • Instruction sheet
Application: For use with 700 • The Fluke 700PTP-1 has Size: L x W x D:
accessories series pressure modules or two pressure ports allowing 220 x 122 x 89 mm
test gauges. Can directly con- simultaneous connection: Weight: 467 g
to enhance nect modules or test gauges to
the reference port consolidat-
• ¼ -NPT female fitting for the Warranty: One year
the power ing two separate pieces when
reference gauge or pressure Material: Wetted materials:
module aluminum, silicon, neoprene,
of your Fluke performing pressure calibration
and testing. Can also be used • ¼” NPT female fitting for the stainless steel, Buna-N
Process with 717 pressure calibrators. unit under test
Calibrators Ideal for calibrating pressure • Adjustable stroke length can Fluke 700HTP-1
transmitters, pressure switches be set to limit the pressure Hydraulic Test Pump
and pressure gauges up to 600 per stroke
PSI/40 bar. Included: Description: The Fluke
700HTP-1 is a hand operated
• 1/4 in NPT male to 1/4 in BSP hydraulic pressure pump
female designed to generate calibration
• 1 meter of hose pressures up to 10,000 psi/690
bar. Designed for use with
Fluke-700 series high pressure
modules such as the Fluke-
700P09, 700P29, 700P30 and
700P31.
Application: Ideal for calibra-
tion when connected to a Fluke
high pressure module via the
reference port. The 700HTP-1
uses distilled water or mineral-
based hydraulic oil as a source
for calibration of high pressure
input devices such as pressure
transmitters or pressure gauges.
Can also be used with Fluke 717
pressure calibrators.
Features:
• Variable size stroke adjust-
ment, allows the user to vary
the volume and pressure per
stroke
• Integral pressure adjustment
vernier knob for fine pressure
adjustment.
Fluke 700PTP-1 Fluke 700HTP-1
Pressure Pumps (continued)

• Direct connection to pres-


sure modules consolidates
two separate pieces into one
when performing pressure
calibration and testing
• Two ¼ inch NPT pressure
ports, one for reference
(pressure module or gauge),
one for UUT
• Compatible with optional
Fluke-700PRV pressure re-
lief valve designed to protect
pressure modules from over-
pressure damage Fluke 700HTH-1 Fluke 700LTP-1
Note: The user must provide a hose with
appropriate end fittings to apply pressure from Fluke 700PRV-1 Fluke 700HTH-1
the UUT port to the calibration unit under test
such as the Fluke-700HTH-1 hose kit.
Pressure Relief Valve Kit Hydraulic Test Hose
Description: The Fluke Description: The Fluke
Included: 700PRV-1 consists of a relief 700HTH-1 hydraulic test hose is
• ¼ inch NPT to ¼ inch NPT valve settable from 725 to 5800 a 10,000 psi, 690 bar working
adapter to connect the refer- PSI (50 to 200 bar) to be used pressure test hose that features
ence gauge port on the pump with the 700HTP-1 Hydraulic stainless steel and nylon con-
body to the 1/4 NPT female Test Pump. The 1/8” NPT male struction for use in connecting
fitting on Fluke 700P29, P30, thread to fits directly into the a Fluke-700HTP-1 or other hy-
and P31 pressure modules. Fluke 700HTP-1 pressure pump. draulic test pump to a unit under
• (2) ¼ inch NPT male to ¼ Application: To be used with test.
inch BSP Female adapters the 700HTP-1 Hydraulic Test Application: The Fluke
• ¼ inch NPT Tee (installed) Pump. The 700PRV uses a 700HTH-1 enables connection
multi-turn adjustment screw to both a Fluke pressure module
• Instruction sheet to set preload on internal disc and a calibration unit under test
Mechanical & General from a Fluke 700HTP-1 hydrau-
Specifications springs. This relief valve will
protect the most commonly lic test pump simultaneously.
Size: L x W x D: used Fluke pressure modules 700HTH-1 is compatible with
241 x 155 x 66 mm and pressure instruments from water and non-corrosive oil.
Weight: 580 g damage due to accidental over- Features:
Warranty: One year pressurization. • Hose and fittings to connect
Material: Wetted materials: 303 Features: directly to the Fluke 700HTP-1
stainless steel, aluminum, • Adjustable from 725 to 5800 test pressure port
polyurethane, PTFE, nitrile, PSI (50 to 200 bar) • Includes plugs and caps to
and nylon
• Preset at 2,900 psi/200 bar) eliminate fluid loss in hose,
• Repeatability to 10% of eliminates the need to
nominal setting. re-prime the hose.
• Installs directly into the • Self-sealing fittings with easy
700HTP-1 pump finger tight connections.
29 Pressure Modules Included: • Low volumetric expansion and
• One adjustable relief valve a negligible pressure drop at
Fluke offers a family of 29 • Instruction sheet rated pressures
Pressure Modules to address gage, Mechanical & General Included:
differential, absolute, vacuum, Specifications • Hose with (2) 1/4" NPT female
and dual (compound) applications Size: 38 mm by 16 mm diameter output connections
to 10,000 psi/700 bar. Weight: 46 g • (2) adapters that to convert ¼:
For detailed specifications Warranty: One year NPT female to 1/4" NPT male
and applications, ask for Material: Type 303 stainless (include sealing caps)
Application Note Pressure steel • 1/4 in NPT female to 1/4 in
Calibration Pub_ID: 10188. BSP male adapter
• Instruction sheet

 Fluke Corporation Process Tools Accessories


Pressure and Calibration Accessories

Mechanical & General


Specifications Ordering information
Minimum bend radius: Model Item Description
60 mm Fluke-700PTP-1 2811774 Pneumatic test pump, -12 to 600 PSI
Working temperature:
- 40 ºC to + 120 ºC Fluke-700HTP-1 2811788 Hydraulic test pump, 0-10,000 PSI
Material: Nylon, stainless steel, Fluke-700PRV-1 2811808 Pressure relief valve for 700HTP
zinc, plated steel, and nitrile
Dimensions: 0.84 m long with- Fluke-700HTH-1 2811795 Hydraulic test hose, 10,000 PSI
out adapter fittings
Fluke-700LTP-1 2811763 Low pressure test pump, -12 to 100 PSI
Weight: 412 g
Warranty: One year
Features: Included:
Fluke 700LTP-1 • Pump can be easily cleaned • (2) adapters to convert the
Low-pressure Test Pump without disassembly. reference and UUT port hose
Description: The Fluke 700LTP- • Adjustable pressure release fitting to 1/4" BSP female
1 is a hand operated pressure valve with slow-bleed • Adapter to convert the refer-
pump designed to generate capability ence port hose fitting to 1/4"
either vacuum to -13 psi/ -.90 • Allows the slow release NPT female for connection to
bar or pressures to 100 psi/ 6.9 pressure at a controlled rate 700 series pressure modules
bar. The Fluke 700LTP-1 has • One seal kit
two pressure ports with quick • Slim design, easy to carry
fit connectors. Test hoses are and use • Instruction sheet in English
terminated with 1/4-NPT female • Quick fit connectors, one for Mechanical & General
fittings that can be adapted the reference port for connec- Specifications
using the BSP/ISO adapters. tion to a Fluke 700 series pres- Size: L x W x D:
Application: For use with 700 sure module and one to con- 150 x 100 x 32 mm
series pressure modules and nect to a unit under test Weight: 226 g (pump only)
717 pressure calibrators. Ideal Warranty: One year
for low pressure applications Material: Aluminum, silicon,
requiring accurate low pressure neoprene, stainless steel, Buna-N
testing.
Fluke 700ILF In-line Filter
For use with: Fluke 717 and
718 Pressure Calibrators
Description: Use to isolate cali-
brator from contact with liquids.
Input is 1/8” NPT female. Output
is 1/8” NPT Male.
Application: The Fluke 700ILF
can be used to isolate the cali-
brator from incidental contact
with fluids present in the gas
medium being measured.
Particularly useful with the 718
calibrator to help keep moisture
or oils from contaminating the
on-board pump. The 1/8” NPT
male threaded output threads
directly into the 717 and 718
calibrators. Maximum pressure is
100 psi. Burst pressure is
375 psi. Maximum flow is 10
SCFM and filtration to 1 micron.
Included: One disposable filter
Dimensions: 54 mm x 48 mm
Weight: 115 g

Fluke 700PCK
Process Tools Accessories Fluke Corporation 
Calibration and Process Calibrator Accessories

Fluke 700PCK Application: The calibration Application: Use the Fluke 700-
Pressure Calibration Kit module provides a 9 volt dc IV Current Shunt to calibrate
For use with: Fluke 700 Series supply to the 787. At the same and troubleshoot mA/mA
Pressure Modules. time, it facilitates RS232 com- devices. On a 741 or 743
Description: The Fluke 700PCK munication from the PC running Documenting Process Calibrator,
makes it possible to calibrate MET/CAL to the 787 over the Source mA and Measure V dc.
your pressure modules at your battery leads of the 787. The custom units function of
facility using your own preci- Included: A calibration manual, the calibrator automatically
sion pressure standards. MET/CAL procedures, and an provides the correct conversion,
Application: When installed interface module that permits and directly displays/captures
on your PC, the Windows ®- serial communication between the current in mA.
based software easily steps you a 787 and a PC. Included: Shunt, instruction
through an as-found verifica- Note: An installation of MET/CAL Calibration sheet.
tion, a calibration adjustment, Software plus appropriate calibration equip- Warranty: One year
ment must be provided by the user.
and an as-left verification.
Calibration data is captured for Required Calibration Equipment for use with
the Fluke 787CAL Calibration Accessory:
Fluke 700BCW
import to your database. A 386 Fluke Model 5500 or 5520 Calibrator Bar Code Wand
or better PC running Windows HP3458 DMM or **HP34401 DMM,
For use with: Fluke 743
3.1 or better is required, along Fluke 5440A-7002 Test Lead set
Documenting Process Calibrator.
with a precision pressure stan- Fluke RS43 Null Modem Cable
Personal Computer, 486 or better, Description: This Hewlett
dard with an uncertainty of less IBM compatible Packard HBSW-8200 Bar Code
than 1/4 that of the pressure Fluke MET/CAL Calibration Software,
Wand reads eight common bar
module being verified. Version 6.0 or later
code symbologies. Code 39,
**HP34401 for use only with 5520A only
Included: The kit consists of 5500A requires HP3458 DMM Interleave 2 or 5, UPC A and E,
a power supply, an interface EAN 8 and 13, Codabar, Code
adapter, appropriate cables, and Fluke 700-IV 128, Code 11, Code 93, and MSI
Fluke 700PC Pressure Module Code. Programmable via bar
Calibration Software. Current Shunt
code labels or escape sequen-
Warranty: One year For use with: Fluke 701, 702, ces. LED indicates when a
and 740 Series Documenting bar code has been correctly
Fluke 787CAL Process Calibrators. decoded. Resolution, 0.0075”
Calibration Module Description: (.19 mm). Usable from -20 to
Conversion factor: 65°C, in ambient light to 100,00
For use with: Fluke 787 Pro- 10 mV = 1 mA
cessMeter™ and MET/CAL Soft- Accuracy (% of input, 1 year): lux. EMI compliance per FCC
ware, version 6.0. part 15 Class B. ESD immunity,
0.025% 25 kV.
Description: The Fluke 787CAL Input current: 0 to 55 mA
module permits users and ser- Application: Supports the
Input resistance: 250Ω, nominal scanned entry of procedure
vice facilities to perform auto- Output resistance: 10Ω, nominal
mated MET/CAL verifications identification, tag ID, serial
Accuracy specification applies number, and operator ID to a
and calibrations of the Fluke from +18°C and 28-50°C
787 ProcessMeter.™ Fluke 743 Documenting Process
Maximum input voltage: 30V dc Calibrator.

Fluke 700-IV Fluke 700BCW

 Fluke Corporation Process Tools Accessories


Included: Bar code wand with Fluke 700TC1 Fluke 700TC2
integrated decoding circuity, Thermocouple Mini-Plug Thermocouple Mini-Plug
holder, and users manual; Kit (11 types) Kit Type J, K, T, E, R/S
a Fluke 700BCA Bar Code
Adapter, and instruction sheet For use with: Fluke 700 or For use with: Fluke 700 or 740
in English, French, German, Ital- 740 Series Documenting Process Series Documenting Process
ian, and Spanish. Calibrators, Fluke 714 Thermo- Calibrators, Fluke 714 Thermo-
Material: Polycarbonate wand, couple Thermometer. couple Thermometer.
sapphire tip. Description: A kit of 10 mini- Description: A kit of seven
Dimensions: 160 mm x 23 mm plug connectors supporting mini-plug connectors supporting
(diameter). Coiled cable extends each of the thermocouple types six of the most popular thermo-
to approximately 2.5 m. supported by the Fluke 700 or couple types.
Weight: 160 g 740 Series Documenting Process Application: Terminate user-
Warranty: One year Calibrators. supplied thermocouple wire to
Application: Terminate user- permit connection to process
Fluke 700BCA supplied thermocouple wire to calibrator.
Bar Code Adapter permit connection to a process Included mini plugs
calibrator. Type J (black), two
For use with: Fluke 743 Docu- Included mini plugs Type K (yellow), two
menting Process Calibrator. Type J (black), one Type T (blue), one
Description: Shielded four Type K (yellow), one Type E (purple), one
conductor cable terminated with Type T (blue), one Type R/S (green), one
a 9-socket D-subminiature Type E (purple), one Material: Thermoplastic plug
connector and a 9-pin D-sub- Type R/S (green), one bodies; contacts of appropriate
miniature connector. Type B or Cu (white), one thermocouple metallurgy.
Application: Provides intercon- Type L (J-DIN) (blue), one Warranty: One year
nection and pin translation Type U (T-DIN) (brown), one
between a Fluke 743 Docu- Type C (red), one
menting Process Calibrator and Type N (orange), one
a Hewlett Packard HBSW-8200 Material: Thermoplastic plug
Bar Code Wand. bodies; contacts of appropriate
Included: Interface cable, thermocouple metallurgy.
(calibrator to bar code wand), Warranty: One year
and instruction sheet inEnglish,
French, German, Italian, and
Spanish.
Material: Black PVC cable and Fluke BP7217
housings, tin plated shells, gold
plated copper contacts.
Dimensions: Overall length
approximately 15 cm
Warranty: One year

Fluke BP7235

Fluke 700TC1 Fluke 700TC2

Process Tools Accessories Fluke Corporation 


Process Calibrator Accessories (continued)

BP7217 BP7235 BE9005 240


Ni-Cd Battery Pack NiMH Battery Pack Battery Eliminator
For use with: Fluke 700 or For use with: Fluke 700 or For use with: Fluke 700 or
740 Series Documenting 740 Series Documenting Process 740 Series Documenting
Process Calibrators. Calibrators, requires BC7217 Process Calibrators.
Description: 7.2V 1700 charger Description: 7.5V dc battery
mA-hour rechargeable Ni-Cd Description: 7.2 V 3500 mA- eliminator for operation of
battery pack. hour rechargeable NiMH battery calibrator from 230 volt ac line.
Application: Provides typical pack. BABT approved.
8-hour battery life when used Application: Provides typical Application: BS-1363 input
in 700 or 740 Calibrators. 16 hour battery life when used plug, used primarily in UK,
Included: One battery pack. in 700 or 740 calibrators. China, and Hong Kong; 230V ac
Material: Six 1.2V dc Ni-Cd Included: One battery pack 50 Hz lines.
cells in custom-molded ABS/PC- Material: Six 1.2 V dc NiMH Dimensions:
blend case. cells in custom-molded ABS/PC- 96 mm x 63 mm x 58 mm;
Dimensions: blend case 1.8 m cord
150 mm x 56 mm x 22 mm Dimensions: Weight: 500 g
Weight: 310 g 150 mm x 56 mm x 22 mm Warranty: One year
Warranty: One year Weight: 310 g
Warranty: One year BC7217
BE9005 120 Battery Charger
Battery Eliminator BE9005 220
For use with: BP7217 NiCd and
For use with: Fluke 700 or Battery Eliminator BP7235 NiMH Battery Packs.
740 Series Documenting For use with: Fluke 700 or Description: Battery charger
Process Calibrators. 740 Series Documenting UL, CSA, MITI, DEMKO, FINKO,
Description: 7.5V dc battery Process Calibrators. SEMKO recognized.
eliminator for operation of Description: 7.5V dc battery CE compliant. EMI per FCC
calibrator from 120 volt ac line. eliminator for operation of part 15 Class B.
UL/CSA recognized. calibrator from 230 volt ac line; Application: Replaces BC7210
Application: For use in North VDE and/or TÜV approved. Battery Charger. Select 120 volt
America; 120V ac 60 Hz lines. Application: CEE-7 input version for use in North America.
Dimensions: connector, used primarily in Select INTL version for use
96 mm x 63 mm x 56 mm; continental Europe; 230V ac outside of North America. Line
1.8 m cord 50 Hz lines. voltage 100 to 250V ac, fre-
Weight: 500 g Dimensions: quency 50 to 60 Hz. IEC 320
Warranty: One year 96 mm x 63 mm x 48 mm; inlet, lne cord will be provided
1.8 m cord based on country of destination.
Weight: 500 g
Warranty: One year

Fluke BE9005 120 Fluke BE9005 220 Fluke BE9005 240

 Fluke Corporation Process Tools Accessories


Included: Battery charger base, C781 Soft Carrying Case C789 Soft Carrying Case
power supply. For use with: Fluke 701, 702,
Dimensions: For use with: Fluke 700 or
740 Series Documenting Process and 740 Series Documenting
Power supply: Process Calibrators. Also fits
100 mm x 66 mm x 41 mm; Calibrators. Also fits DSP-100
CableMeter ® or DSP-200 Cable- DSP-100 CableMeter ® or
1.8 m cord DSP-200 CableAnalyzer™ and
Charger base: Analyzer™ and Fluke 860 Series
Graphical Multimeters. Fluke 860 Series Graphical Mul-
116 mm x 104 mm x 58 mm timeters.
Weight: 780 g Description: Rugged, close-
fitting fabric carrying case for Description: Rugged, three-
Warranty: One year compartment fabric carrying
documenting process calibrator.
case for documenting process
C700 Hard Carrying Case A separate, detachable pouch
holds test leads and accessories. calibrator and accessories. Cen-
(700 Series) Application: Designed to be ter zippered compartment holds
worn on a belt. Remove the the calibrator, while zippered
For use with: Fluke 700 or side compartments are suitable
740 Series Documenting calibrator from the C781 for use.
Material: Black woven nylon, for leads, pressure modules, or
Process Calibrators. spare batteries. A flat pocket on
Description: Hard carrying case black vinyl, with yellow Fluke the back surface is ideal for a
with custom-cut foam liner. logo panel.
Dimensions: manual or notebook.
Application: Cutouts to hold Application: Front access flat
one documenting process Primary compartment:
26 cm x 14 cm x 5 cm. allows the calibrator to be used
calibrator, one Fluke Pressure while in the C789 Case.
Module, one BC7210 Battery Detachable accessory pouch:
19 cm x 14 cm x 3 cm Designed to be carried over
Charger, one spare BP7217 one shoulder.
Battery Pack, and test leads. Weight: 230 g
Included: Case, detachable
Material: Exterior: Blow-molded Warranty: One year handle, and detachable
charcoal gray polyethylene with shoulder strap.
textured surface. Interior: Black, Material: Black woven nylon,
die-cut polyurethane foam. black vinyl, with yellow Fluke
Handle: Molded polyethylene. logo panels.
Latches: Zinc-plated steel. Dimensions:
Dimensions: 30 cm x 25 cm x 8 cm
47 cm x 40 cm x 14 cm Weight: 700 g
Weight: 900 g Warranty: One year
Warranty: One year

BC7217 Fluke C789, C700, C781

Process Tools Accessories Fluke Corporation 


General-Purpose Accessories

743B/ 741B 725/ 712 714 715 717 787 87V 51/52 705/ 123
744 726 707
Fluke 700Pxx Pressure Modules 1 • • • •
BP7217 NiCd Battery Pack • •
BP7235 NiMH Battery Pack • •
BE9005 Battery Eliminator • •
BC7217 Battery Charger • •
Fluke 700BCW Bar Code Wand •
Fluke 700BCA Bar Code Adapter •
Fluke 700TCI and TC2 Thermocouple Plug Kits • • • •
80CJ-M and 80CK-M Mini-Connectors • • • • •
80PK Thermocouple Probes (all) • • • • •
Fluke 700-IV Current Shunt • • • • • •
Fluke 700PMP Pressure Pump • • • •
Fluke 700PTP-1 Pneumatic Test Pump • • • •
Fluke 700HTP-1 Hydraulic Test Pump • • • •
Fluke 700LTP-1 Low Pressure Test Pump • • • •
Fluke 787CAL Calibration Kit •
80T-IR Infrared Probe • • • • • • •
80PK-IR Infrared Probe • • • • •
80TK Thermocouple Module • • • • • • • •
80T-150U Universal Temperature Probe • • • • • • • •
TL220/222/224/226/228 Lead Sets • • • • • • • • •
TL70A and Y8140A Lead Sets • • • • • • • •
AC220 and AC280 Clips • • • • • • • • •
TP220 Industrial Test Probes • • • • 2 • • 3 •
3 •
80i-400 AC Current Clamp • • 2 • 3 •3
i410 AC/DC Current Clamp • • • • • • •
i1010 AC/DC Current Clamp • • • • • • • •
C10 Holster and C12A Case •
C25/C28/C90/C100/C800 Cases • • • • • •
C781 Soft Carrying Case • •
C789 Soft Carrying Case • • •
C700 Hard Carrying Case • •
C120 and C125 Case •
80K-6 and 80K-40 High Voltage Probes • • • • •
PV350 Pressure Vacuum Module • • • • • • •
Fiber Optic Meter (FOM) • • • • • • •
1
Ask for Application Note Pub_ID: 10188
2
DC current only
3
20A ac minimum

Fluke. Keeping your world


up and running.®

Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD, Eindhoven, The Netherlands
For more information call:
U.S.A. (800) 443-5853 or Fax (425) 446-5116
Europe: +31 (0)40 2 675 200 or Fax +31 (0)40 2 675 222
Canada (800)-36-FLUKE or Fax (905) 890-6866
Other countries +1 (425) 446-5500 or Fax (425) 446-5116
Internet: http://www.fluke.eu