Вы находитесь на странице: 1из 4

c) (i) Executed in last seven financial years between 2012-13 and 2018-19, the

minimum quantities of the following items of work as indicated in below

Intake Structure (25%) -Not Applicable-


WTP (25%) -Not Applicable-
SR (50%) 148 Lakh Litres

Pipeline (25%) The bidder should have executed laying and jointing
98 KM (25% of total length) of diameter 100mm to
1450 mm or above DI, CI, MS, HDPE.

Pump ( At least 50% of discharge 90 m3/hr and 15 m


and 50% of Head)

Transformers (25%) -Not Applicable-


House Service Connection (50%) Bidder should have experience in providing house
connections in similar size municipality/corporation
area in india for minimum number of 19072 Nos
HSC

SCADA Instrumentation Control and Automation for


SCADA
O&M The contractor/firm should have executed O&M of
Municipal water supply scheme for a period not less
than 3 years in last 10 years for being eligible.

O&M The contractor/firm must have satisfactorily


completed as a prime contractor at least one similar
O&M work of value not less than 35% of O&M
contract value (excluding power costs) in any one
year
Remarks

70 Lakh Litr in DVC (certificate available)


+ 70 Lakh Ltr in Madhyamgram (new
certificate required) + DJB Dwarka (new
certificate required)

71.5 KM DI Pipe in Dambulla


48.36 KM MS Pipeline (above 100) in
Kakatiya. Thus Wabag Qualifies

Wabag Qualifies

Do not Qualify

Wabag Qualifies

Dhanbad

O&M Estimate is 7.88 Crs for 5 years. 35%


of it is 2.76 Crs. Dhanbad one year value is
3.5 Crs Hence we qualify
Executed in any one year in last five years (on prorata basis) the minimum quantities
of the following items of work as indicated in Appendix.

R.C.C. Intake Well/Pump House Tender Capacity :43.5 MLD, 25% of 43.5 MLD is
(25%) 11 MLD
WTP (25%) 10.875 MLD
E.S.R (50 %) 3.5 Lakh Liters

Sump/GSR (50%) 31.50 Lakh Liters

Supplying & laying of The bidder should have laying and jointing
CI/DI/MS/PVC/AC 96793 mts length of different dia. pipe line
Water Supply Pipeline (25 % 0f (100 mm and above)
Avg.
Diameter)

Pump –Motor (50 %) Discharge 9,375 lpm (of higher capacity pump
Required head 50m or installed capacity of 240 HP
pumps.)
Transformers (50%) 1000 KVA
House Service Connection (25%) 13762 nos
Remarks

We donot Have Intake Well

We qualify
Shollinganallur WSS- 35 Lakh Liters

70 Lakh Litr in DVC (certificate available)

71.5 KM DI Pipe in Dambulla


48.36 KM MS Pipeline (above 100) in
Kakatiya. Thus Wabag Qualifies

Wabag Qualifies

Wabag Qualifies
Do not Qualify

Вам также может понравиться