EVER Water Heaters - Technical Data:

TANK HEATING RATED RATED C. B. NUMBER NO. OF HEATING TIME INLET and DIMENSIONS WEIGHT
MODEL CAPACITY ELEMENT VOLTAGE PHASE CURRENT PROTECTION OF FLANGES/ COLD TO HOT OUTLET PIPE (mm) EMPTY/FULL
(Liters/Gallons) (kW) (V/Hz) (A) (AT) THERMOSTAT ELEMENTS 80°C (minutes) (inch) A B (kG)
WH 20 20 / 5 1 x 1.5 220 / 60 1 6.8 15 1 1/1 50 1/2 330 380 17 / 37
WH 30 30 / 7.5 1 x 1.5 220 / 60 1 6.8 15 1 1/1 70 1/2 330 500 21 / 51
WH 30S 30 / 7.5 1 x 2.0 220 / 60 1 9.1 15 1 1/2 60 1/2 330 500 21 / 51
WH 80 80 / 20 1 x 3.0 220 / 60 1 13.6 20 1 1/3 140 1/2 450 800 23 / 103
WH 80S 80 / 20 2 x 3.0 220 / 60 1 / 3 27.2 / 15.7 40 / 30 2 2/6 70 1/2 450 800 23 / 103
WH 200 200 / 50 1 x 6.0 220 / 60 1 / 3 27.2 / 15.7 40 / 30 1 1/3 140 1 660 1000 87 / 287
WH 200S 200 / 50 2 x 6.0 220 / 60 1 / 3 54.5 / 31.5 90 / 50 2 2/6 70 1 660 1000 87 / 287
WH 450 450 / 120 2 x 6.0 220 / 60 1 / 3 54.5 / 31.5 90 / 50 2 2/6 140 1 660 1900 164 / 614
WH 450-S1 450 / 120 3 x 6.0 220 / 60 3 47.2 70 3 3/9 90 1 660 1900 164 / 614
WH 450-S2 450 / 120 4 x 6.0 220 / 60 3 63.0 100 4 4 / 12 70 1 660 1900 164 / 614

Installation and Operating Instruction:

THANK YOU!!! for choosing EVER Water Heater for your hot water needs.But before using, it is important
to consider the following operating instructions for safety and to obtain maximum performance:
1. Install the water heater indoor or in a covered area not directly exposed to sunlight and in accessible location
considering convenient in piping installations, electrical connections & maintenance purposes.
2. Connect the incoming water mains (cold) to the pipe marked blue. Do not install check valve, the water heater
is equipped with built-in anti-siphon system.
3. Connect the outgoing heater tap line (hot) to the pipe marked red.
4. Connect the water heater to the power lines. Use included power cord or the correct size of wire and the
recommended protective device. For safety it is advisable to use individual protection for every water heater
Provide appropriate grounding system for this equipment/appliance.
5. Fill the water heater with water until water comes out from the outgoing water tapline. Make sure the drain
plug is close before filling. Do not use the water heater for Artesian(hard water), brackish and salty water.
6. Set the thermostat to off position by turning the knob counter clockwise until a "clicking"sound is heard.
7. Switch on or energized the water heater.
8. Slowly turn the thermostat knob clockwise to the desired temperature. The water heater operates automatically
maintaining the pre-set temperature.

SIDE CUT VIEW FRONT CUT VIEW INSTRUCTION

WARNING !!!
NEVER ENERGIZE THE
WATER HEATER WHEN
EMPTY
Not
Note: Install an appropriate PRV /
pressure regulating valve when the
systems working pressure exceeds the
standard inlet working pressure.

WARRANTY STATEMENT

All EVER branded products are guaranteed for one year from the date of purchase against faulty materials and bad
workmanship. Keep receipt or invoice for reckoning of date of purchase.
In case of warranty claim, notify the company or appointed dealer immediately and wait for further instructions. Do not allow
any unauthorized person to dismantle or try to repair this may render your claim void. All service/repair will be carried out in
the shortest possible time to the satisfaction of our customer.