In LVDT the primary and secondary windings are coupled –

A Inductively B Capacitively
C Resistively D Galvanically

What type of error is shown in the figure above –


A. Zero error B. Span Error C. Linearity Error D. Hysteresis Error

36. In a closed loop control employing PID controller, which of the following control
action eliminates offset -
A. Proportional (P) B. Integral (I)
C. Derivative (D) D. None of the above

30. In manometers, which is not a method to improve sensitivity and resolution for
measurement of low pressures -
A. Using manometer fluid with higher density
B. Using well type manometer with other limb as thin tube
C. Using inclined tube manometer
D. None of the above.

44. Match each of the 6 feature given under column A to the most appropriate of the 3
temperature measuring device under column B and write your answer clearly (e.g. if A.1
matches with B.2, write A.1 B.2) (3 marks)
A B
1. Most sensitive 3 1. Thermocouple
2. Does not suffer from self heating 1 2. RTD
3. Most linear 2 3. Thermistor
4. Requires cold junction compensation 1
5. Narrowest range of measurement 3
6. Self powered 1

29. Match each of the symbol representation of instrument given under


column A to their most appropriate description given under column B and
write your answer clearly (e.g. if A.1 matches with B.2, write A.1 B.2)
(2 marks)
A B
1. 1. Field mounted discrete instrument

2. 2. Discrete instrument mounted in auxiliary location

3. 3. Discrete instrument mounted in main location (CR)

4. 4. Shared display of instrument

Answer the following questions by marking True or False (half mark each) -

45. A lesser value of drift error makes repeatability error less.


46. All transducers are sensors, but all sensors are not transducers.
47. A load cell can have piezoresistive transducer but not piezoelectric transducer.
48. A transmitter always has a transducer.
49. ‘Air to open’ type valve actuators and valve body are direct acting. F
50. In a PID control, reducing derivative time would decrease derivative action
component of control.
51. Noble metal thermocouples have lower sensitivity but wider temperature
measurement range than base metal thermocouples.
52. It is easier to correct random errors of measurement, than systematic errors.
53. Resolution of an instrument is expected to be greater than dead band.
54. A valve with quick opening inherent characteristic can be expected to have linear
installed characteristics. (f)