Вы находитесь на странице: 1из 15

WITTUR-GROUP

DRIVE RANGE
&
CAR DOOR LOCK

ECO-MIDI-SUPRA

F. Leutner / 04.06.2005 Page 1 © 2003 WITTUR - Update 05/03 - All rights reserved - Legal Notice
WITTUR-GROUP

OVERVIEW

PIUMA AUGUSTA HYDRA PEGASUS

ECO MIDI SUPRA

PIUMA-ECO AUGUSTA-ECO HYDRA-ECO PEGASUS-MIDI

HYDRA-MIDI PEGASUS-SUPRA

HYDRA-SUPRA

F. Leutner / 04.06.2005 Page 2 © 2003 WITTUR - Update 05/03 - All rights reserved - Legal Notice
WITTUR-GROUP

ECO - Augusta

F. Leutner / 04.06.2005 Page 3 © 2003 WITTUR - Update 05/03 - All rights reserved - Legal Notice
WITTUR-GROUP

ECO - Hydra

F. Leutner / 04.06.2005 Page 4 © 2003 WITTUR - Update 05/03 - All rights reserved - Legal Notice
WITTUR-GROUP

TECHNICAL DATA

ECO MIDI SUPRA


 motor type DC DC AC
(brushless)

 control PWM PWM V3F


 max. power 150W 550W 900W
 door opening time 2,1 s 1,3 s 1,0 s
(type 02/C, PL=800, std. panels)

 working temperature 0...+50°C -20...+50°C


power supply 127/230V - 50/60Hz

F. Leutner / 04.06.2005 Page 5 © 2003 WITTUR - Update 05/03 - All rights reserved - Legal Notice
WITTUR-GROUP

PERFORMANCE

1,0

SUPRA
0,8
speed [m/s]

0,6
MIDI

0,4 ECO

0,2
0
250 500 750

Belt force [N]

F. Leutner / 04.06.2005 Page 6 © 2003 WITTUR - Update 05/03 - All rights reserved - Legal Notice
WITTUR-GROUP

FEATURES

 operator tested and pre-adjusted in factory


 self learning, no adjustments at site necessary - „PLUG&PLAY“
 easy speed selection with DIP switches (4 profiles)
 optional settings for special purposes (modernization)
 easy adjustable electronically controlled close force
 continuos mass detection - different panel weights in one
elevator
 battery drive as standard
 service tool (WPT) for service and fine tuning
 open force limitation
 light screen (LSE) connection

F. Leutner / 04.06.2005 Page 7 © 2003 WITTUR - Update 05/03 - All rights reserved - Legal Notice
WITTUR-GROUP

SUPPLY

 line voltage: 127/230V - 50/60Hz

 emergency battery supply: 24V


X5
+
24V DC Emergency Bat tery Supply
+ - + -
12 V 12V

F. Leutner / 04.06.2005 Page 8 © 2003 WITTUR - Update 05/03 - All rights reserved - Legal Notice
WITTUR-GROUP

INPUTS / OUTPUTS
 INPUTS

 OUTPUTS

F. Leutner / 04.06.2005 Page 9 © 2003 WITTUR - Update 05/03 - All rights reserved - Legal Notice
WITTUR-GROUP

LSE SUPPLY
 24VDC (150mA) supply for receiver and transmitter
 output signal is handled by electronic (reopen selectable)
 free terminal for synchronisation wire

F. Leutner / 04.06.2005 Page 10 © 2003 WITTUR - Update 05/03 - All rights reserved - Legal Notice
WITTUR-GROUP

ADJUSTMENT POSSIBILITIES
 Close force with potentiometer
 DIP switch:
S1... Test button operation
S2... Automatic reopen
S3... Swing door mode
S4... Reduced motor torque
S5/S6... Speed setting
S7... Open force limitation
S8... Automatic end keeping

F. Leutner / 04.06.2005 Page 11 © 2003 WITTUR - Update 05/03 - All rights reserved - Legal Notice
WITTUR-GROUP

WPT - WITTUR PROGRAMMING TOOL


 Fine tuning
- open/close/nudging/cam speed
- brake parameter
- acceleration
- re-open time
- position output
Diagnostics
- error list
- belt position
Statistic
- door cycles (counter)
- operating time
- distance of rollers
- energy consumption

F. Leutner / 04.06.2005 Page 12 © 2003 WITTUR - Update 05/03 - All rights reserved - Legal Notice
WITTUR-GROUP

NEW CAM
 Optimised for ECO/MIDI/SUPRA
 Harmonised design for Augusta/Hydra/Pegasus
 Improved execution for MIDI/SUPRA
 Different offsets for Hydra

F. Leutner / 04.06.2005 Page 13 © 2003 WITTUR - Update 05/03 - All rights reserved - Legal Notice
WITTUR-GROUP

Car door lock function

car is moving car stops in door zone car stops outside door zone
vanes are not pressed rollers are detected and vanes are not pressed
vanes are pressed
car door is locked car door is locked
car door is unlocked
F. Leutner / 04.06.2005 Page 14 © 2003 WITTUR - Update 05/03 - All rights reserved - Legal Notice
WITTUR-GROUP

Car door lock features

 Completely integrated in cam


 EN81 conform - TÜV approved
 No sill extensions or shaft vanes necessary
 No minimising of running clearances
 Afterwards assembling possible
 emergency opening device optional

F. Leutner / 04.06.2005 Page 15 © 2003 WITTUR - Update 05/03 - All rights reserved - Legal Notice