GENERAL NOTES : LEGEND

MOUNTING
1. Any Switch box shown on the edge of the wall shall be
SYMBOL DESCRIPTION HEIGHT
200mm away from the edge unless other wise specified.
1
FROM FFL
2 2
W W The two way switch shown beside the door shall be
2.
STBR I.D.U. A / C 200mm away from the opened shutter of the door. CEILING FAN -----

All sockets in kitchen and toilets has to be provided

1245
3.
EL +600 mm EXHAUST FAN WITH SOCKET AT 7'-8"HT
only after tile marking. Sockets has to be provided to EF
KITCHEN 2
FD match inline with either to the top corner or bottom RECESSED TYPE CEILING -----

TV(A)
TV
2
EC
1730 corner of the tile. (NOT in between tile joint). LIGHT FITTING
Connected in ONLINE UPS Circuit
4. Power point circuit wiring & light circuit wiring should
NOT be drawn in same conduit i.e Wiring for both shall FTL PATTI FITTING AT 7'-8"HT

1570
( WALL MOUNTED TYPE )
be drawn directly from the DB through Individual
2 wiring & conduit system,similarly two different phase FTL PATTI FITTING
( WALL MOUNTED TYPE ) AT 7'-8"HT
wires should Not be drawn in a same conduit.
D
BED ROOM 1 Connected in ONLINE UPS Circuit
2100
3 KW 3 W1 5. Also in a single circuit of same Phase where Two or WALL LIGHT FITTING AT 7'-8"HT
DINING 2 More SB's are Interlinked, The circuit wiring from WALL LIGHT FITTING
AT 7'-8"HT
1st SB to Subsequent SB's can be drawn through Connected in ONLINE UPS Circuit
2 2 same Light Point Conduiting. Otherwise from DB BULK HEAD FITTING AT 7'-8"HT
3 to First Switch Board for Lighting Circuit main
ONE WAY SWITCH AT 4'-0" HT
seperate wiring & conduiting to be laid.
V V ONE WAY SWITCH
POWDER AT 4'-0" HT
EL ±00 mm 6. For last Light points/Fan points/6A Socket outlets Connected in ONLINE UPS Circuit
4

ROOM TOILET
UP wherever maximum 4 nos wires are involved in such
cases 20mmØ conduit shall be used otherwise all other
TWO WAY SWITCH
Connected in ONLINE UPS Circuit
AT 4'-0" HT
places wherever morethan 4 nos wires are involved 6A SOCKET & SWITCH
2 IN SWITCH BOARD ( DEP )
AT 4'-0" HT
2 25mmØ conduit shall be used in the light points /
UP Fan points / 6A Sockets outlets wiring system. ELECTRIC BELL AT 4'-0" HT
EL +750 mm
7. For Individual Light Circuit Wiring & Power Circuit TELEPHONE OUTLET WITH
wiring 20mmØ conduit shall be used as indicated in 6A ( INDEP ) SWITCH WITH
TP(A)
COURTYARD
5

the DB SLD. 6A SOCKET OUTLET. ( INCLU


EL +300 mm

-DING WITH TP OUTLET, CON AT 2'-0" HT


8. Ckt-L1 - LPDB means individual / seperate conduit -DUIT, SWITCH, SOCKET &
with wiring between LPDB to that particular Lighting WIRING TO BE CONSIDERED )
DN DN EL +600 mm DN Circuit points to be laid as indicate in the DB SLD. TP(A) - ACTIVE POINT
25A 3PIN SOCKET FOR IN
2 9. Ckt-P1 - LPDB means individual / seperate conduit (A) -DOOR HIGH WALL SPLIT A/C
with wiring between LPDB to that particular Power ( INCLUDING WITH CONDUIT
6 SOCKET & WIRING ) i.e. IN AT 8'-0"HT
Circuit points to be laid as indicate in the DB SLD. AC-I
SERVICE LINE WITH BOTTOM OF A/C
ENTRY EL UP 10. wherever necessary junction boxes to be provided 25A DOUBLE POLE SWITCH
4 +750mm (A) WITH INDICATOR AND 25A,
for main Power / TV / TP / Data conduits. which
EL +600mm 3 PIN SOCKET FOR STABILIZER
are to be laid from Floor shaft to inside the ( INCLUDING CONDUIT WITH
AC-S AT 2'-0" HT
Apartment DB/TV & TP Junction Boxes. SWITCH, SOCKET & WIRING )
TOILET 11. For Telephone point Wiring, i.e,. 20mm dia conduit
(A) - ACTIVE POINT
SINGLE PHASE STABILIZER
STBR AT 2'-0" HT
7

V shall be used right from Apartment JB to TP Socket FOR A/C


outlets. The For Telephone point Wiring i.e,. 20mm
2 2 dia conduit shall be used right from Apartment JB F.C.U. A / C AC INDOOR UNIT AT 2'-0" HT
LIVING ROOM to TP Socket outlets. The same arrangement is to be
PUJA ROOM EL+750 mm followed to Data point wiring. (looping of One TP D DATA POINT AT 2'-0" HT
W 2 PT to other subseqent TP PT not permitted ) SWITCHING PANEL
MD 4 AT 7'-8"HT
2100
TV

W1 TV AND TELEPHONE
TV(A)

12. For Television point Wiring, i.e,. 20mm dia conduit JUNCTION BOX AT 8'-0" HT
D
8
shall be used right from Apartment JB to TV Socket
4 BED ROOM 2 UPS DB AT 5'-6" HT
2 Outlets. ( looping of One TV PT to other subseqent
UP
1785

LIGHTING & POWER


2 TV PT not permitted ) AT 5'-6" HT
UP 2 EL ±00 mm
DISTRIBUTION BOARD (LPDB)
13. All the switch box should be mounted in Flush with PSB 6A/16A COMBINED SOCKET. AT 4'-0" HT
EL +300 mm
final finished plastering /punning level.
)A(VT

1730 14. Junction boxes with in Apartment wherever BELL-PUSH


TV

AT 8'-0" HT
necessary to be mounted in invisible location.
8
FD 1 x 28W FTL PATTI FITTING -----
UP
1245

EL +600 mm 15. No Junction Box Above DB not Required


EL +/- 0.0 mm SUSPENDED DOWN LIGHT -----
16. Output The stabilizer switched Socket
Outlet & Stabilizer Should be TWO WAY
STBR I.D.U. A / C Conduit
mounted as Shown with proper UPS WAY
25A
W STBR spacing as shown Including
100 300 100
Output Conduit to indoor AC Unit. TELEPHONE

UP A/C
8

EL +/- 0.0 mm TV TV

PROJECT : RELEASED FOR:


This drawing is the property of PADGRO CONSULANTS PRIVATE LID REV DATE REVISION DES NAME SIGN DATE
and must not be passed on to any person or body not authorised RESIDENCE FOR Mr.RAGHU & FAMILY PRELIMINARY TENDER INFORMATION APPROVAL CONSTRUCTION
by us to recieve it nor be copied or otherwise made use of either in full 18.06.2015 TOILETS DESIGN BSM 28.05.2015
or in part by such person or body without our prior permission in writing