Академический Документы
Профессиональный Документы
Культура Документы
PROJECT : IR
JOB NO. : Universal Studio
LOCATION : FC-07
PREPARED BY : KS
A. INPUT DATA
fcu = 55 N/mm2
fy = 460 N/mm2
fyv = 460 N/mm2
Thickness of Slab, h = 600 mm
Concrete Cover, c = 50 mm
Slab Reinft. Provided, Ast = T 16 - 200 c/c (TT) and T 0- 250 c/c (T)
= 1005 mm2 + 0 mm2
= 1005 mm2
Asb = T 16 - 200 c/c (BB) and T 0- 250 c/c (B)
= 1005 mm2 + 0 mm2
= 1005 mm2
v= Vult/(Uc*d)
= 1.097 N/mm2 less than vmax, O.K.
where
vmax = 0.8*fcu^0.5 or 5 N/mm2 whichever smaller
= 5 N/mm2
av = 1.5d = 801 mm
Perimeter, Up = 12*d+2*(Cx+Cy)
= 9608 mm
v/vc = 0.89
SAsv*sina >= No Shear Links required.
A. INPUT DATA
fcu = 55 N/mm2
fy = 460 N/mm2
fyv = 460 N/mm2
Thickness of Slab, h = 2500 mm
Concrete Cover, c = 50 mm
Slab Reinft. Provided, Ast = T 32 - 250 c/c (TT) and T 0- 250 c/c (T)
= 3217 mm2 + 0 mm2
= 3217 mm2
Asb = T 40 - 125 c/c (BB) and T 0- 250 c/c (B)
= ### mm2 + 0 mm2
= ### mm2
v= Vult/(Uc*d)
= 2.42 N/mm2 less than vmax, O.K.
where
vmax = 0.8*fcu^0.5 or 5 N/mm2 whichever smaller
= 5 N/mm2
av = 1.5d = 3615 mm
Perimeter, Up = 12*d+2*(Cx+Cy)
= ### mm
v/vc = 0.64
SAsv*sinS >= No Shear Links required.
A. INPUT DATA
fcu = 55 N/mm2
fy = 460 N/mm2
fyv = 460 N/mm2
Thickness of Slab, h = 1200 mm
Concrete Cover, c = 50 mm
Slab Reinft. Provided, Ast = T 25 - 250 c/c (TT) and T 32 - 250 c/c (T)
= 1963 mm2 + 3217 mm2
= 5180 mm2
Asb = T 20 - 250 c/c (BB) and T 40 - 250 c/c (B)
= 1257 mm2 + 5027 mm2
= 6283 mm2
v= Vult/(Uc*d)
= 3.07 N/mm2 less than vmax, O.K.
where
vmax = 0.8*fcu^0.5 or 5 N/mm2 whichever smaller
= 5 N/mm2
av = 1.5d = 1695 mm
Perimeter, Up = 12*d+2*(Cx+Cy)
= ### mm
v/vc = 0.99
SAsv*sinS >= No Shear Links required.
A. INPUT DATA
fcu = 55 N/mm2
fy = 460 N/mm2
fyv = 460 N/mm2
Thickness of Slab, h = 1200 mm
Concrete Cover, c = 50 mm
Slab Reinft. Provided, Ast = T 25 - 250 c/c (TT) and T 0- 250 c/c (T)
= 1963 mm2 + 0 mm2
= 1963 mm2
Asb = T 20 - 250 c/c (BB) and T 40 - 250 c/c (B)
= 1257 mm2 + 5027 mm2
= 6283 mm2
v= Vult/(Uc*d)
= 1.798 N/mm2 less than vmax, O.K.
where
vmax = 0.8*fcu^0.5 or 5 N/mm2 whichever smaller
= 5 N/mm2
av = 1.5d = 1695 mm
Perimeter, Up = 12*d+2*(Cx+Cy)
= ### mm
v/vc = 0.58
SAsv*sinS >= No Shear Links required.
A. INPUT DATA
fcu = 35 N/mm2
fy = 460 N/mm2
fyv = 460 N/mm2
Thickness of Slab, h = 200 mm
Concrete Cover, c = 30 mm
Slab Reinft. Provided, Ast = T 10 - 200 c/c (TT) and T 10 - 400 c/c (T)
= 393 mm2 + 196 mm2
= 589 mm2
Asb = T 10 - 200 c/c (BB) and T 0- 100 c/c (B)
= 393 mm2 + 0 mm2
= 393 mm2
v= Vult/(Uc*d)
= 0.302 N/mm2 less than vmax, O.K.
where
vmax = 0.8*fcu^0.5 or 5 N/mm2 whichever smaller
= 4.733 N/mm2
av = 1.5d = 240 mm
Perimeter, Up = 12*d+2*(Cx+Cy)
= 4220 mm
v/vc = 0.31
SAsv*sinS >= No Shear Links required.
A. INPUT DATA
fcu = 30 N/mm2
fy = 460 N/mm2
fyv = 460 N/mm2
Thickness of Slab, h = 200 mm
Concrete Cover, c = 25 mm
Slab Reinft. Provided, Ast = T 10 - 200 c/c (TT) and T 0 - 400 c/c (T)
= 393 mm2 + 0 mm2
= 393 mm2
Asb = T 10 - 200 c/c (BB) and T 0 - 100 c/c (B)
= 393 mm2 + 0 mm2
= 393 mm2
v = Vult/(Uc*d)
= 0.083 N/mm2 less than vmax, O.K.
where
vmax = 0.8*fcu^0.5 or 5 N/mm2 whichever smaller
= 4.382 N/mm2
av = 1.5d = 247.5 mm
Perimeter, Up = 12*d+2*(Cx+Cy)
= 2780 mm
v/vc = 0.05
SAsv*sinS >= No Shear Links required.