==================Command==========================================

rxtcp:moty=rxotg,cell=MS4099E;
rlcfp:cell=MS4099E;
rldep:cell=MS4099E;
rlnrp:cell=MS4099E,cellr=all,nodata;
rxasp:mo=RXOTG-321;
rlstp:cell=MS4099E;
rxcdp:mo=rxotg-321;
rlcpp:cell=MS4099E;
RXAPP:MO=RXOCF-321;
rxmfp:mo=RXOCF-321;
rxmfp:mo=RXORX-321-0,faulty,subord;
rxmfp:mo=RXORX-321-1,faulty,subord;
rxmfp:mo=RXORX-321-4,faulty,subord;

====================Result======================================================
==
tulusan@ran1uas01:~$ eaw BPLK5
<rxtcp:moty=rxotg,cell=MS4099E;
RADIO X-CEIVER ADMINISTRATION
TG TO CHANNEL GROUP CONNECTION DATA

MO CELL CHGR
RXOTG-321 MS4099E 0
MS4099E 1

END

<rlcfp:cell=MS4099E;
CELL CONFIGURATION FREQUENCY DATA

CELL
MS4099E

CHGR SCTYPE SDCCH SDCCHAC TN CBCH HSN HOP DCHNO


0 2 0 1 YES 37 OFF 803
2
1 0 0 1 NO 37 ON 776
850
852
END

<rldep:cell=MS4099E;
CELL DESCRIPTION DATA

CELL CGI BSIC BCCHNO AGBLK MFRMS IRC


MS4099E 510-10-11537-40995 61 803 1 6 ON

TYPE BCCHTYPE FNOFFSET XRANGE CSYSTYPE


INT NCOMB 0 NO GSM1800

CELLIND RAC RIMNACC GAN DFI


H'176
END
<rlnrp:cell=MS4099E,cellr=all,nodata;
NEIGHBOUR RELATION DATA

CELL
MS4099E

CELLR DIR CAND CS


MS4120B MUTUAL BOTH NO

CELLR DIR CAND CS


MS4120A MUTUAL BOTH NO

CELLR DIR CAND CS


MS4120C MUTUAL BOTH NO

CELLR DIR CAND CS


MS4099B MUTUAL BOTH NO

CELLR DIR CAND CS


MS4099F MUTUAL BOTH YES

CELLR DIR CAND CS


MS4099G MUTUAL BOTH YES
END

<rxasp:mo=RXOTG-321;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT ALARM SITUATIONS

MO SCGR SC RSITE ALARM SITUATION


RXOTG-321 N_MSJ099DSILAGO
RXOCF-321 N_MSJ099DSILAGO BTS INT UNAFFECTED
RXOMCTR-321-0 N_MSJ099DSILAGO BTS INT UNAFFECTED
RXOMCTR-321-1 N_MSJ099DSILAGO BTS INT UNAFFECTED
RXOMCTR-321-2 N_MSJ099DSILAGO BTS INT UNAFFECTED
RXORX-321-0 N_MSJ099DSILAGO BTS INT UNAFFECTED
RXORX-321-1 N_MSJ099DSILAGO BTS INT UNAFFECTED
RXORX-321-4 N_MSJ099DSILAGO BTS INT UNAFFECTED
RXORX-321-5 N_MSJ099DSILAGO BTS INT UNAFFECTED
RXORX-321-8 N_MSJ099DSILAGO BTS INT UNAFFECTED
RXORX-321-9 N_MSJ099DSILAGO BTS INT UNAFFECTED

END
<rlstp:cell=MS4099E;
CELL STATUS

CELL STATE CHGR STATE


MS4099E ACTIVE 0 ACTIVE
1 ACTIVE
END
<rxcdp:mo=rxotg-321;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT CONFIGURATION DATA

MO RESULT ARFCN MISMATCH


RXORX-321-0 CONFIG HOP NONE
RXORX-321-1 CONFIG HOP NONE
RXORX-321-4 CONFIG HOP NONE
RXORX-321-5 CONFIG HOP NONE
RXORX-321-8 CONFIG HOP NONE
RXORX-321-9 CONFIG HOP NONE

MO RESULT ARFCN TXAD TN BPC CHCOMB OFFS XRA ICM


RXOTS-321-0-0 CONFIG 803 0 0 81 BCCH 0 NO ON
RXOTS-321-0-1 CONFIG 803 0 1 65 CBCH8 0 NO ON
RXOTS-321-0-2 CONFIG 803 0 2 60 SDCCH8 0 NO ON
RXOTS-321-0-3 CONFIG 803 0 3 16028 TCH 0 NO ON
RXOTS-321-0-4 CONFIG 803 0 4 16021 TCH 0 NO ON
RXOTS-321-0-5 CONFIG 803 0 5 16011 TCH 0 NO ON
RXOTS-321-0-6 CONFIG 803 0 6 16004 TCH 0 NO ON
RXOTS-321-0-7 CONFIG 803 0 7 16003 TCH 0 NO ON
RXOTS-321-1-0 CONFIG HOP 3 0 56 TCH 0 NO ON
RXOTS-321-1-1 CONFIG HOP 3 2 54 TCH 0 NO ON
RXOTS-321-1-2 CONFIG HOP 3 3 52 TCH 0 NO ON
RXOTS-321-1-3 CONFIG HOP 3 4 49 TCH 0 NO ON
RXOTS-321-1-4 CONFIG HOP 3 5 47 TCH 0 NO ON
RXOTS-321-1-5 CONFIG HOP 3 6 45 TCH 0 NO ON
RXOTS-321-1-6 CONFIG HOP 3 7 43 TCH 0 NO ON
RXOTS-321-1-7 CONFIG HOP 3 1 5120 TCH 0 NO ON
RXOTS-321-4-0 CONFIG 785 1 0 80 BCCH 0 NO ON
RXOTS-321-4-1 CONFIG 785 1 1 62 CBCH8 0 NO ON
RXOTS-321-4-2 CONFIG 785 1 2 58 SDCCH8 0 NO ON
RXOTS-321-4-3 CONFIG 785 1 3 16002 TCH 0 NO ON
RXOTS-321-4-4 CONFIG 785 1 4 16001 TCH 0 NO ON
RXOTS-321-4-5 CONFIG 785 1 5 16000 TCH 0 NO ON
RXOTS-321-4-6 CONFIG 785 1 6 15997 TCH 0 NO ON
RXOTS-321-4-7 CONFIG 785 1 7 15994 TCH 0 NO ON
RXOTS-321-5-0 CONFIG HOP 4 0 41 TCH 0 NO ON
RXOTS-321-5-1 CONFIG HOP 4 2 39 TCH 0 NO ON
RXOTS-321-5-2 CONFIG HOP 4 3 35 TCH 0 NO ON
RXOTS-321-5-3 CONFIG HOP 4 4 33 TCH 0 NO ON
RXOTS-321-5-4 CONFIG HOP 4 5 30 TCH 0 NO ON
RXOTS-321-5-5 CONFIG HOP 4 6 28 TCH 0 NO ON
RXOTS-321-5-6 CONFIG HOP 4 7 25 TCH 0 NO ON
RXOTS-321-5-7 CONFIG HOP 4 1 10055 TCH 0 NO ON
RXOTS-321-8-0 CONFIG 791 2 0 79 BCCH 0 NO ON
RXOTS-321-8-1 CONFIG 791 2 1 61 CBCH8 0 NO ON
RXOTS-321-8-2 CONFIG 791 2 2 57 SDCCH8 0 NO ON
RXOTS-321-8-3 CONFIG 791 2 3 15989 TCH 0 NO ON
RXOTS-321-8-4 CONFIG 791 2 4 15988 TCH 0 NO ON
RXOTS-321-8-5 CONFIG 791 2 5 15985 TCH 0 NO ON
RXOTS-321-8-6 CONFIG 791 2 6 15983 TCH 0 NO ON
RXOTS-321-8-7 CONFIG 791 2 7 15979 TCH 0 NO ON
RXOTS-321-9-0 CONFIG HOP 5 0 21 TCH 0 NO ON
RXOTS-321-9-1 CONFIG HOP 5 2 13 TCH 0 NO ON
RXOTS-321-9-2 CONFIG HOP 5 3 16344 TCH 0 NO ON
RXOTS-321-9-3 CONFIG HOP 5 4 16305 TCH 0 NO ON
RXOTS-321-9-4 CONFIG HOP 5 5 16268 TCH 0 NO ON
RXOTS-321-9-5 CONFIG HOP 5 6 16227 TCH 0 NO ON
RXOTS-321-9-6 CONFIG HOP 5 7 16187 TCH 0 NO ON
RXOTS-321-9-7 CONFIG HOP 5 1 16036 TCH 0 NO ON

MO RESULT ARFCN TXAD BSPWR C0F MISMATCH


RXOTX-321-0 CONFIG 803 0 42 YES NONE
RXOTX-321-1 CONFIG HOP 3 42 NO NONE
RXOTX-321-4 CONFIG 785 1 42 YES NONE
RXOTX-321-5 CONFIG HOP 4 42 NO NONE
RXOTX-321-8 CONFIG 791 2 42 YES NONE
RXOTX-321-9 CONFIG HOP 5 42 NO NONE

MO RESULT TFMODE SYNCSRC FSOFFSET TFCOMP MISMATCH


RXOTF-321 CONFIG SA DEFAULT OFF NONE

MO RESULT BANDWIDTH MCTRPWR MISMATCH


RXOMCTR-321-0 CONFIG 154 45 NONE
RXOMCTR-321-1 CONFIG 164 45 NONE
RXOMCTR-321-2 CONFIG 88 45 NONE

INSUFFICIENT TX EQUIPMENT

END

<rlcpp:cell=MS4099E;
CELL CONFIGURATION POWER DATA

CELL TYPE BSPWRB BSPWRT MSTXPWR SCTYPE


MS4099E INT 42 42 30
END
<RXAPP:MO=RXOTG-321;
NOT ACCEPTED
FAULT CODE 109
COMMAND NOT VALID FOR CURRENT TG TRANSMISSION MODE
(0)MO=RXOTG-321

<RXAPP:MO=RXOCF-321;
NOT ACCEPTED
FAULT CODE 4
WRONG MO CLASS
(0)MO=RXOCF-321

<rxmfp:mo=RXOCF-321;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT FAULT INFORMATION

MO BTSSWVER
RXOCF-321 ERA-G07-R26-V01

RU RUREVISION RUSERIALNO
0 KDU 137 569/1 R2B X174401306

RUPOSITION RULOGICALID
C:0 R:- SH:-- SL:--- DX DUG 20 01 0

RU RUREVISION RUSERIALNO
1

RUPOSITION RULOGICALID
C:0 R:- SH:-- SL:--- CABI 0

RU RUREVISION RUSERIALNO
2 KRC 118 65/1 R2A CC47206965

RUPOSITION RULOGICALID
C:0 R:- SH:-- SL:--- MCTR RUS 01 B3 0

RU RUREVISION RUSERIALNO
3 KRC 118 65/1 R2A CC47082868

RUPOSITION RULOGICALID
C:0 R:- SH:-- SL:--- MCTR RUS 01 B3 1

RU RUREVISION RUSERIALNO
4 KRC 118 65/1 R2A CB4K676721

RUPOSITION RULOGICALID
C:0 R:- SH:-- SL:--- MCTR RUS 01 B3 2

STATE BLSTATE INTERCNT CONCNT CONERRCNT LASTFLT LFREASON


OPER 00019

FAULT CODES CLASS 2A


33 57 58

REPLACEMENT UNITS
40 61 63

END
<rxmfp:mo=RXORX-321-0,faulty,subord;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT FAULT INFORMATION

MO BTSSWVER
RXORX-321-0 ERA-G07-R26-V01

RU RUREVISION RUSERIALNO
0

RUPOSITION RULOGICALID

STATE BLSTATE INTERCNT CONCNT CONERRCNT LASTFLT LFREASON


OPER 00000

FAULT CODES CLASS 2A


6

END

<rxmfp:mo=RXORX-321-1,faulty,subord;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT FAULT INFORMATION

MO BTSSWVER
RXORX-321-1 ERA-G07-R26-V01

RU RUREVISION RUSERIALNO
0

RUPOSITION RULOGICALID

STATE BLSTATE INTERCNT CONCNT CONERRCNT LASTFLT LFREASON


OPER 00000

FAULT CODES CLASS 2A


6

END
<rxmfp:mo=RXORX-321-4,faulty,subord;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT FAULT INFORMATION

MO BTSSWVER
RXORX-321-4 ERA-G07-R26-V01

RU RUREVISION RUSERIALNO
0

RUPOSITION RULOGICALID

STATE BLSTATE INTERCNT CONCNT CONERRCNT LASTFLT LFREASON


OPER 00000

FAULT CODES CLASS 2A


2 6

END
RXORX-321-0 ERA-G07-R26-V01

RU RUREVISION RUSERIALNO
0

RUPOSITION RULOGICALID

STATE BLSTATE INTERCNT CONCNT CONERRCNT LASTFLT LFREASON


OPER 00000

FAULT CODES CLASS 2A


6

END

<rxmfp:mo=RXORX-321-1,faulty,subord;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT FAULT INFORMATION

MO BTSSWVER
RXORX-321-1 ERA-G07-R26-V01

RU RUREVISION RUSERIALNO
0

RUPOSITION RULOGICALID

STATE BLSTATE INTERCNT CONCNT CONERRCNT LASTFLT LFREASON


OPER 00000

FAULT CODES CLASS 2A


6

END
<rxmfp:mo=RXORX-321-4,faulty,subord;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT FAULT INFORMATION

MO BTSSWVER
RXORX-321-4 ERA-G07-R26-V01

RU RUREVISION RUSERIALNO
0

RUPOSITION RULOGICALID

STATE BLSTATE INTERCNT CONCNT CONERRCNT LASTFLT LFREASON


OPER 00000

FAULT CODES CLASS 2A


2 6

END