Вы находитесь на странице: 1из 3

PRODUCT APPLICATION NOTE

Gas Pressure Control - Clocking

Introduction
Low pressure networks are one of the key contributors to gas emissions, which have both financial and
environmental impacts.
Pressure control is used by gas utilities to reduce excessive pressure and leakage in the network. Leakage is
proportional to the pressure of gas and can be reduced by applying advanced pressure management at the
pressure regulators.
Established pressure profiling technology is capable of varying the outlet pressure of the governor to suit
network demand; pressures can be raised at periods of high demand and decreased at periods of low demand.

Technolog Limited, +44(0)1629 823611 Copyright Technolog 2017


All rights reserved. Specifications subject to change without prior notice.
Ravenstor Road, technolog@technolog.com
1000AN9002 issue A. DMR n/a
Wirksworth, www.technolog.com
DE4 4FY, United Kingdom
PRODUCT APPLICATION NOTE

Gas Pressure Control - Clocking

Technology
A single dual diaphragm control pilot is used in the auxiliary rail to adjust downstream pressure of the regulator
according to user programmable times of the day.
The image below shows an example of a clocked profile. Simple step changes to the outlet pressure of the
regulator station provide both a day and a night setting.

Technolog Limited, +44(0)1629 823611 Copyright Technolog 2017


All rights reserved. Specifications subject to change without prior notice.
Ravenstor Road, technolog@technolog.com
1000AN9002 issue A. DMR n/a
Wirksworth, www.technolog.com
DE4 4FY, United Kingdom
PRODUCT APPLICATION NOTE

Gas Pressure Control - Clocking

Product Technical Matrix

Newlog 4 Newlog 4DR


Cello GS3 VAM
Profiler, Autogas Mk2
Service Water, Gas Gas Water, Gas Gas
Mode of Communication Local / 2G / 3G Local / GSM / PSTN Local / 2G No

User Accessible SIM Yes N/A Yes N/A

User Replaceable Battery Yes Yes Yes Yes

Available Channels 8 8 3 N/A

Optional Pressure Inputs 3 3 1 N/A

Supported Pressure Recording Strategies I/A/S I/ S I/A/S N/A

Optional Temperature (PT-100) Inputs 1 0 0 N/A

Available Digital Inputs 5 8 2 N/A

Available Analogue Inputs 5 0 0 N/A

Internal / External Supply Internal Internal Internal Internal


Powering of Third Party Sensors No No No No
WITS Compliance No No No No
Intrinsically Safe Yes Yes Yes Yes
Protection Class IP 67 IP 54 IP 68 IP 66

Ultrasonic Probe,
Level Monitoring Capability Level transmiter, No Float Switch No
Float Switch,

Key : Pressure Recording Strategy ( I - Instantaneous / A - Average / S - Statistical / T - Transient )

Technolog Limited, +44(0)1629 823611 Copyright Technolog 2017


All rights reserved. Specifications subject to change without prior notice.
Ravenstor Road, technolog@technolog.com
1000AN9002 issue A. DMR n/a
Wirksworth, www.technolog.com
DE4 4FY, United Kingdom

Вам также может понравиться