Home > Guest Post > UPS-SL650 repaired

UPS-SL650 repaired
By Jestine Yong on December 3, 2015

SHARE TWEET SHARE SHARE 14 COMMENTS

This UPS (Uninterruptible Power Supply) was


brought to me with the purpose to replace the
seal lead acid battery rated as 12v/7Ah.

ELECTRONICS REPAIR CATEGORIES

Electronics Repair Categories


Select Category

REPAIR TIPS POPULAR COMMENTS

Iphone 6 With Error 53


Repaired
...
When the device was disarmed look what I saw:
July 29, 2017 10

Servicing IMPEX Induction


Cooker Model IX-R20
This...
July 29, 2017 8

Completed Another
Higher Advanced
Electronics Repair Course
...
July 29, 2017 3

7N65C Power FET Shorted


In Singer Hi-Fi DVD
...
July 28, 2017 8

A Water Flow Device


Repair. Model: Matic
This...
July 28, 2017 6

Completed Another
Advanced Electronics
Repair Course
...
July 26, 2017 20

As you can see there were three bulged e-caps and a lot of dry solder joints and the PCB was
black in some places indicates heating problem in the components.

The three e-caps (2 x 1000µF/35v and 1 x 220 µ F/35v) were replaced.

LIKE US ON FACEBOOK
The dry solder joints were reestablish with fresh tin and the new battery was replaced.

When the device was connected into the AC-mains and switched on, it was switching continuously
from Normal operation to Back Up operation (inverted mode) once and again.

At this time the job continued, my first doubt were the relays, therefore they were extracted from
the circuit.

They were checked with a DC Power Supply and a Digital Multimeter, and all of them were ok. The
components situated around the five relays were checked one by one with the DMM, and know
what? A crystal diode was de-soldered from the circuit, I realized from this situation by chance
because I was touching some components with the tips of the DMM

The relays were re-connected again. This time the UPS was tested with the connection of the AC-
mains and look at the result .
This article was prepared for you by Humberto Rodriguez, one of our ‘Master Authors’ from Cuba.

Please give a support by clicking on the social buttons below. Your feedback on the post is
welcome. Please leave it in the comments.

P.S- If you enjoyed reading this, click here to subscribe to my blog (free subscription). That way,
you’ll never miss a post. You can also forward this website link to your friends and colleagues-
thanks!

Note: You may check his previous repair article in the below link:

http://www.jestineyong.com/beware-when-it-comes-to-solder-e-caps-in-pcbs/

Likes 159))
( 159 Dislikes ( 0)

UPS Repair

RELATED POSTS
Riello, Dialog Plus 70, UPS, NRG GUARD 2000A UPS,
No Output Repair NOT STARTING REPAIR UPS-SL650 Repaired UPS Repaired

14 COMMENTS

Parasuraman S

December 3, 2015 at 10:49 am

Good Job! Looks like it was brought to you after tampering!

Likes (0) Dislikes (0)

Reply

Humberto

December 4, 2015 at 11:39 pm

Yes Parasuraman, another tech reviwed it before me.

Likes (0) Dislikes (0)

Reply

Yogesh Panchal

December 3, 2015 at 2:20 pm

Good job Humberto and thanks for sharing.

Likes (1) Dislikes (0)

Reply

Humberto

December 4, 2015 at 11:31 pm

Thanks Yogesh

Likes (0) Dislikes (0)

Reply

Robert Calk

December 4, 2015 at 6:23 am

Good job getting it fixed, Humberto. The new e-caps look like cheap ones and may not last very long.

Likes (3) Dislikes (1)

Reply

Humberto

December 4, 2015 at 11:41 pm

Yes Robert the new ones are not high quality; remember the restrcitions of my country.

Likes (1) Dislikes (0)

Reply

Robert Calk

December 9, 2015 at 2:10 am

Yeah, I forgot about that. My apologies, Humberto.

Likes (0) Dislikes (1)

Reply

Chris

December 4, 2015 at 8:45 pm

Hi!
Nice job done, congratulation!
I have questions about you repair result:
1. Is the man AC voltage in your country 110v/60Hz?
2. I hope the UPS did not work on an output voltage of 98V or under?

I had some trouble with testing relay's before, some time they worked when I tested them but actually they was
bad. So I decide to make a small tester for relay's with a micro controller and a PC software.
I connect the relay to the uC and let them toggling on some frequency's
and I count how many times was the relay powered on and how many times where the working contact shorted
and that is sent to my PC.
I test relays for 2-5 min's.
The result should be like this: one power on should indicate one closing contact ( or releasing ). If there is some
difference between the power the coil of the relay and the closing of the working contact then the relay failed.
There is simpler ways too to achieve this result but this was for me an easy task and I love to work with uC...

However, god job done.


My best regards.

Likes (3) Dislikes (0)

Reply

Humberto

December 4, 2015 at 11:47 pm

Hi Chris 110v/60Hz in my country, the 98v is due to a new Baterry, remember it had to be charged first, that's
why the 98V. When it was just repaired I performed that measuring with my DMM.
Thanks anyway.

Likes (0) Dislikes (0)

Reply

Ulises Aguilar Pazzani

December 5, 2015 at 1:07 am

nice job Sir

Likes (0) Dislikes (0)

Reply

Albert van Bemmelen

December 5, 2015 at 5:23 pm

Hi Humberto. nice repair. Thanks! I also liked the post Chris wrote about testing relays. It could be a very handy
tool as DIY relay tester project! Indeed Relay contacts tend to get bad after many high current switching
moments. The only way to normally be able to see this, is to open them. With the solution of Chris you don´t
have to.

Likes (0) Dislikes (0)

Reply

Owais Akhter

May 14, 2017 at 4:07 am

Hi All,
Galco Repairs,Global Electronics Service and many well known repair companies experts directly
changed Relay, Opto-Isolator even they found good after load test. The reason for that is these
components work very frequently and in high speed switching in UPS or other Types of Inverters.That is
why their repairing is not just repair but refurbished equipment.

Likes (0) Dislikes (0)

Reply

Albert Hoekman, Holland

December 8, 2015 at 8:23 pm

Good Job Humberto. Thanks for sharing this nice article.

Likes (0) Dislikes (0)

Reply

ron

December 12, 2015 at 8:39 am

Thanks for your info.

Ur pretty smart guy!!

Thanks again.
Ron

Likes (0) Dislikes (0)

Reply