Академический Документы
Профессиональный Документы
Культура Документы
(39.95m HEIGHT) (G+12) FOR M/s. ASSET HOMES PVT LTD AT DESIYA
KAVALA,KAKKANAD
No: CGL/RT/175/17
1. INTRODUCTION
There is a proposal to construct a apartment (39.95m Height) (G+12) at Desiya
Kavala,Kakkanad for M/s. Asset homes Pvt Ltd . It is decided to carry out a detailed
sub soil investigation to find out Safe bearing capacity and selection of appropriate
foundation for the building.
The work was awarded to M/s CGL Geoinformatics, 51/937 B, Paradise Road, Vytilla
P.O, Ernakulam 682019. A detailed field investigation were carried out from
15/02/2018 to 23/03/2018. This report summarizes the subsoil investigations and furnishes the
recommendation
on the type of the foundation to be provided.
2. SCOPE OF WORK
The scope of work at this site, entrusted with us comprised of
2.1 Mobilization of boring rigs with all necessary equipments and skilled/unskilled
personals for the field work.
2.2 Boring three bore holes of diameter 150 mm, with drilling equipments in sand,
silt, clay and gravel to a maximum depth of 19.35 m or till the spoon rebound
whichever is earlier at the selected location fixed by the client.
2.3 Conduction of Standard Penetration tests in bore holes at every 1.0 m upto 6m
depth and at every 1.5m after that depth or change of strata and prepare bore
log showing details.
2.4 Collection of disturbed samples in air tight polythene bags with proper labelling
and transportation to laboratory.
2.5 Conducting the laboratory tests on the disturbed samples as per Indian
Standards and furnishing the results.
2.6 Preparation and submission of the detailed report with field and laboratory
results.
3. PROGRAMME OF INVESTIGATION
3.1 FIELD INVESTIGATION
3.1.1 One boring unit with all necessary equipment along with a team of technical
3.1.3 Representative samples were collected at every 1.0m / 1.5 m depth interval
3.1.4 The samples collected were carefully sealed and transported to laboratory
for tests.
3.1.5 Standard Penetration Tests were conducted at every 1.0 m depth till 6m and
at every 1.5m intervals after that, as per IS: 2131-1981. Before testing
borehole was cleaned properly and Split Spoon Sampler is placed centrally
in bore holes. A standard hammer of 63.5 kg is dropped from a height of 75
cm and number of blows for penetration of sampler for 0-15 cm, 15-30 cm
and 30-45 cm were noted. Number of blows required for 15-45 cm
penetration is reported as N value.
3.1.6 Bore holes were terminated after the investigation. 3.2 LABORATORY INVESTIGATION
3.2.1 The following laboratory tests were conducted on the selected samples as
relevant IS codes.
a) Particle size Analysis (IS .2720-Part 4-1985)
b) Water content (IS .2720-Part 2-1973)
c) Bulk density (IS .2720-Part 9-1992)
d) Specific Gravity (IS .2720-Part 3-1980)
e) Direct Shear Test (IS .2720-Part 13-1986)
f) Triaxial Test (IS.2720(Part-11)-1971)
g) Liquid Limit & Plastic Limit (.2720-Part 5-1985)
h) Unconfined Compression Test (IS .2720-Part 10-1975)
Best regards,
4.00 1 1 2 3
6.00
5.00 1 0 2 2
5.00
Clayey Sand(Brown) 3.50
9.00
3.00
CLIENT M/s.ASSET HOMES PVT LTD
Description of soil
Remarks
Date of completion:16/02/2018
Ground water table:2.66m below the GL
6.00
5.00 1 0 2 2
6.00 4 6 12 18
7.50 4 9 9 18
9.00 Recovery=100%R
QD=45%
10.00 Recovery=100%R
QD=93%
Lateritic Sand
Basil E J, B.Tech
(Engineer In Charge)
depth
(m) 15 cm 30 cm 45 cm
N Value
10 20 30 40 50 >50
Sand(Brown) 2.00
2.00
1.00 1 2 2 4
2.00 1 0 1 1
4.00 2 4 4 8
5.00 5 2 4 6
Description of soil
Graph of ‘N’
value
Remarks
Date of completion:15/02/2018
Ground water table:2.66m below the GL below GL Depth in m Bore log Thickness of layer m
Standard Penetration Test
6.00
Lateritic Sand 2.00
9.00
3.00 Lateritic Clay with
Pebbles
5.00 5 2 4 6
6.00 1 2 2 4
7.50 5 4 5 9
9.00 6 10 11 21
10.50 9 10 13 23
11.10 Recovery=49%
RQD=49%
Basil E J, B.Tech
(Engineer In Charge)
9.00
3.00 Lateritic Clay with
Pebbles
depth
(m) 15 cm 30 cm 45 cm
N Value
10 20 30 40 50 >50
1.00 3 3 3 6 No sample
2.00 2 2 1 3
3.00 1 2 4 6 No sample
4.00
Gravel 4.00
12.00
6.00 Lateritic Clay with
Sand
CLIENT M/s.ASSET HOMES PVT LTD
Description of soil
Graph of ‘N’
value
Remarks
Date of completion:13/02/2018
Ground water table:2.53m below the GL
6.00 2 4 7 11
7.50 3 3 4 7
9.00 3 6 7 13
10.50 7 6 8 14
12.00 3 5 9 14
13.50 12 9 10 19
17.45 Recovery=100%
RQD=Nil
17.75 Recovery=56%
RQD=22%
Basil E J, B.Tech
(Engineer In Charge)
15.00
Lateritic Clay 3.00
TEST RESULTS
CLIENT: M/s. Asset Homes Pvt.Ltd(C/o CGL Geoinformatics, Kochi-19)Report. No. CGL/C/637/17
SITE: Desiya Kavala,Kakkanad Bore hole No. Depth m
Shear - 0.06 12
I 9.0- 10.0
I 10.0- 11.0
Shear - 0.07 28
II 7.5 Gravelly Sandy Clay(SC- GC) 35.00 1.766 45.5 26.4 39 20 16 1 24 ds Direct
(All the tests are done on remoulded sample collected from SPT spoon)
Shear - 0.10 32
II 11.1- 13.0
Shear - 0.00 32
III 6.0 Sandy Clay(CH-SP) 28.44 1.762 51.1 25.5 51 19 28 2 0 ds Triaxial 2.64 0.19 14
III 9.0 Sandy Clay(CI-SP) 36.40 1.733 48.5 31.1 55 10 30 5 0 ds Triaxial - 0.18 20
III 12.0 Clay(CH) 51.09 1.681 105.1 54.8 97 3 0 0 0 ds Triaxial 2.65 0.28 7
III 15.0 Clayey Sand(SC) 32.49 1.888 53.1 32.0 44 25 29 1 1 ds Direct
Shear - 0.12 33
(All the tests are done on remoulded sample collected from SPT spoon)
Vyttila Linish Varghese, B.Tech
28/02/2018 Senior Engineer
RECOMMENDATIONS
INTRODUCTION
M/s CGL Geoinformatics, 51/937 B, Paradise Road, Vyttila PO, Kochi 682019 had
conducted site investigation for the proposed apartment building (G+12) of M/s Asset
Homes Private Limited at Desiya Kavala, Kakkanad. Three boreholes were taken up to
a maximum depth of 19.35 m using rotary drilling. Standard Penetration Tests were
conducted at regular vertical intervals and the samples taken during the investigation
were tested in the laboratory.
RECOMMENDATIONS
Tip
resistance
kN
Side
friction
kN
Safe axial
load
kN
Uplift
load
kN
Lateral
load
kN
1 600 1160 110 1270 120 50
2 700 1580 130 1710 140 70
3 800 2070 150 2220 170 90
4 900 2610 170 2780 210 115
5 1000 3220 210 3430 260 140
6 1100 3900 230 4130 300 175
In BH-3 location
Sl no
Pile
Diameter
mm
Tip
resistance
kN
Side
friction
kN
Safe axial
load
kN
Uplift
load
kN
Lateral
load
kN
1 600 1190 210 1400 230 50
2 700 1610 250 1890 280 70
3 800 2110 290 2400 350 90
4 900 2670 320 2990 410 115
5 1000 3300 360 3660 470 140
6 1100 3990 390 4380 550 175
iii) For arriving the frictional force, the top 2.0 m of soil is discarded. Factor of
safety of 2.5 for side friction and 2.5 for end bearing are taken for the
design. A factor of safety of three was taken for arriving lateral load. Piles
are considered as long piles and pile heads are considered as fixed heads.
iv) The sub structure has to be constructed as per latest IS code and it should
be certified by a qualified engineer.
v) The load carrying capacity of pile should be ensured by conducting initial
pile load test as per IS.2911 (Part IV) or by conducting High strain rate
dynamic pile load test. Routine pile load test should also be conducted as
per I.S specification.
vi) Quality of piling like concreting, diameter of pile, depth of pile, etc should
be ensured by Sonic pile integrity test.
vii) These recommendations are based on three borehole data obtained. If
there is any variation in the soil profile is observed during the boring
operation, it should be referred to a Geotechnical Engineer.