Problem: Convert Alpha RT-B (HSU) to RT-A (HBS) cause the unit to stop functioning
Phenomenon:
When login to RADWIN 2000 Alpha (by default function as RT-B (HSU)) and “Change ODU Mode”
to RT-A (HBS), the unit is reset and the management to the unit is lost (WEB and RADWIN
manager). The unit response only to ping for about 30-40 seconds and reset again.
Affected units:
RADWIN 2000 Alpha units that shipped from 15/7/2018 – 31/10/2018
Resolution:
I. Unit that already changed mode to RT-A (HBS)
RADWIN developed a tool that enables to recover the unit. Recover the unit is done in 2
steps:
1) Running a tool that stops the unit from reset every few seconds and recovers the
communication with the unit via WEB interface
2) Upgrades the unit via the WEB interface recovers the communication with the unit via
RADWIN manager
2. Please use the FTP link below to download the 4.9.50 Software Upgrade file (SWU). The
file is compressed (ZIP) and need to be extracted 4.9.50_SWUL
3. Please connect your PC to the Alpha unit and ping the unit continuously ("ping IP
Address -t")
5. As soon as the unit stop the reply to ping, enter the following command:
"fixAlphCPE5.exe IP Address"
6. The tool continuously keeps trying to access and recover the unit.
Note that the tool might fail on the first and second attempts however it keeps trying to
access the unit as soon as the ping reply is back again.
Leave the tool running (even if the ping reply is lost) until it will display the following
confirmation request: “Update cached key?” (see below screen shot).
Once this request appears, type "y" and press Enter.
7. The tool will complete the process and will display “worked OK!” indication for a
successful recovery process (see below screen shot).
9. After verify that the ping is stable, access the unit via the WEB Management and go to
"Tools" > "Unit" > "Software Upgrade", press the "Upload" button to select the
"SWUL_5k.swul" file you downloaded and extracted
10. Run the upgrade process according to the WEB management instructions.
11. After the upgrade is completed, open RADWIN manager and verify that the unit is
accessible. At this point you can set the unit to RT-A (HBS) if needed.
Download the 4.9.50 SWU file and save it in a directory on your PC/Server.
2. In the software upgrade window of the RADWIN manager click the "Upgrade
package", browse the directory where the 4.9.50 SWU file is located and select it.
Sincerely
Yaron Greenberg
Director Global Support