Академический Документы
Профессиональный Документы
Культура Документы
Protected Equipment
Equipment ID # Type Serial # MAWP Protected Status
Compound Streams
There are no Compound Streams.
Contingency Scenarios
Area Controlling Scenario: Inlet Controlling Scenario: Outlet Controlling Scenario: Worksheet Version:
Exchanger Tube Rupture - E-501A [Unknown] [Unknown] 1.1.6.51 [ Current ]
Contingency Type Req'd ASME Area Inlet Drop Back Press. AIV Status Apply Status
Revision History
Rev. Stage: As At: Signoff By: Prepared By: Approved By: Accepted By:
New 2019-07-19 Ursu, Anamaria
Rev. Status Rev. # Rev. Stage Rev. Date Prepared By Approved By Accepted By
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//system/005570932/... 7/19/2019
Protected System Summary - "E-501A/B Shell/E-502 Tube" - iPRSM / AECOM Page 2 of 2
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//system/005570932/... 7/19/2019
System Pressure Relief Valve Data Sheets - E-501A/B Shell/E-502 Tube - iPRSM / A... Page 1 of 3
Model Selection
Manufacturer: Farris Set Pressure: 50 psig Inlet Outlet
Model Number: 26LB10L BP Superimposed Constant: 0 psig Size: 3 in 4 in
Valve Type: Balanced Bellows BP Superimposed Variable: 0 psig Rating: 150 # 150 #
Cap Construction: - BP Built-Up: 10 psig Facing: - Raised Face
ASME Orifice Area: 3.17 in² Cold Diff. Test Pressure: 50 psig
API Designation: L - 2.853" Maximum % OVP: 10 % Test Media: -
Max. Rel. Cap: 10008 lbm/hr Operating Temperature: 290 °F NPC (Air): 3475 SCFM
Noise Level (Atm): 107.66 dBA NACE: No NPC (Steam): 9763 lbm/hr
Reactive Force: 259.67 lbf Rupture Disk Coefficient: 1 NPC (Water): 526 US gal/min
Model Materials
Body: Carbon Steel (SA-216 Gr. WCB) Disk: 316 SS Bellows: Inconel Composite Option 1:
Bonnet: Carbon Steel (SA-216 Gr. WCB) Guide: 316 SS O-Ring: None Option 2:
Nozzle: 316 SS Spring: Chrome Alloy Spring #: Option 3:
Spring Range: - Other/SP:
Protected Equipment
Equipment Number Description P & ID Number MAWP Operating P Design T
E-501A Shell Side Heat Exch. S/S 50 psig 2.5 psig 650 °F
E-501B Shell Side Heat Exch. S/S 50 psig 2.3 psig 650 °F
E-502 Tube Side Heat Exch. T/S 50 psig 1.3 psig 650 °F
Contingency Scenarios
# Name Cause of OVP Equation Type Relief Load Set P Relief T Req'd Area
1 E-501A Exchanger Tube Rupture Vapor 9665.9 lbm/hr 50 psig 350 °F 3.0617 in²
2 E-501B Exchanger Tube Rupture Liquid 286.75 US gal/min 50 psig 80 °F 1.7264 in²
Orifice area:
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//system/005570932/... 7/19/2019
System Pressure Relief Valve Data Sheets - E-501A/B Shell/E-502 Tube - iPRSM / A... Page 2 of 3
Acalc 3.0617 in² Calculated ASME orifice area before crit 9665.9 lbm/hr Required vapor capacity
Wvapor
consistency checks
calc 9665.9 lbm/hr Required relief rate including capacity Orfcount 2 Number of orifices - must be in
Wvapor interval (0, 2]
credit
Trelief 350 °F Vapor relieving temperature at valve d 0.584 in Tube ID
inlet [ Basis = 809.67 °R ]
Corf 0.6 Orifice coefficient
Z 0.9753 Compressibility factor
ρvap 1.123 lbm/ft³ Vapor density at the inlet of the
Prelief 69.4 psia Relieving pressure tube rupture
C 351.1 Gas-Vapor flow constant ktr 1.342 Gas-Vapor ratio of specific heats
at the inlet of the tube rupture
gas 0.8577 Calculated ASME certified gas
K High pressure side operating
coefficient of discharge P1 609.4 psia
pressure - absolute
KCCF 1 Aggregate rupture disk coefficient
Wvapor
tube 9665.9 lbm/hr Tube rupture flow rate before
gas 1 Backpressure vapor-gas correction capacity credit
Kbp
factor net 1091.5 ft³/min Volumetric flow rate minus
Mvapor 18.02 Mol Wt Avg mol weight of vapor Vgas
capacity credit
CapCredit vap 0 ft³/min Vapor capacity credit to be
subtracted from tube rupture flow
Scenario Notes 2019-07-19 01:57:55 - Anamaria Ursu There are no heat exchangers in the protected system.
Revision History
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//system/005570932/... 7/19/2019
System Pressure Relief Valve Data Sheets - E-501A/B Shell/E-502 Tube - iPRSM / A... Page 3 of 3
Rev. Stage: As At: Signoff By: Prepared By: Approved By: Accepted By:
New 2019-07-19 Ursu, Anamaria
Rev. Status Rev. # Rev. Stage Rev. Date Prepared By Approved By Accepted By
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//system/005570932/... 7/19/2019
Protected System Contingency Analysis - "E-501A/B Shell/E-502 Tube" - iPRSM / A... Page 1 of 2
Contingencies
Required ASME Inlet Back AIV
# Contingency Type Apply Status
Area or Flow Drop Pressure Status
1 Blocked Outlet No
2019-07-19 01:57:55 - Anamaria Ursu
None of the incoming streams have sufficient pressure to cause relief.
2 Abnormal Heat Input No
2019-07-19 01:57:55 - Anamaria Ursu
The protected system is not susceptible to abnormal heat or vapor input.
3 Exchanger Tube Rupture - E-501A | Tube Rupture - Vapor 3.0617 in² N/A N/A N/A Yes Checked
2019-07-19 01:57:55 - Anamaria Ursu
There are no heat exchangers in the protected system.
4 Exchanger Tube Rupture - E-501B | Tube Rupture - Liquid 1.7264 in² N/A N/A Yes Checked
5 Automatic Control Failure No
2019-07-19 01:57:55 - Anamaria Ursu
There are no control valves in the protected system.
6 Reflux Failure No
2019-07-19 01:57:55 - Anamaria Ursu
There is no reflux in the protected system.
7 Fire No
2019-07-19 01:57:56 - Anamaria Ursu
The protected system contains no equipment that requires fire case relief protection.
8 Cooling Failure No
2019-07-19 01:57:56 - Anamaria Ursu
There is no coolant that will affect the protected system.
9 Power Failure No
2019-07-19 01:57:56 - Anamaria Ursu
Power failure will not cause relief.
10 Instrument Air Failure No
2019-07-19 01:57:56 - Anamaria Ursu
There is no instrument air used in or that will affect the protected system.
11 Inadvertent Valve Opening No
2019-07-19 01:57:56 - Anamaria Ursu
The opening of any individual valve, which is normally closed, will not cause relief.
12 Mech. Equip. Failure No
2019-07-19 01:57:56 - Anamaria Ursu
Failure of mechanical equipment will not cause relief.
13 Series Fractionation No
2019-07-19 01:57:56 - Anamaria Ursu
The protected system does not involve series fractionation.
14 Thermal No
2019-07-19 01:57:56 - Anamaria Ursu
The system is not liquid filled; therefore, overpressure by liquid thermal expansion is not possible.
15 Loss of Quench No
2019-07-19 01:57:56 - Anamaria Ursu
There is no quench or cold feed in the protected system.
16 Chemical Reaction No
2019-07-19 01:57:56 - Anamaria Ursu
The possibility of a chemical reaction occurring in the protected system is so unlikely that it is not considered for this study.
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//system/005570932/... 7/19/2019
Protected System Contingency Analysis - "E-501A/B Shell/E-502 Tube" - iPRSM / A... Page 2 of 2
17 Steam Out No
2019-07-19 01:57:56 - Anamaria Ursu
Steam out of this system is highly unlikely.
18 Other No
2019-07-19 01:57:56 - Anamaria Ursu
No other relief contingencies have been identified for this system.
Revision History
Rev. Stage: As At: Signoff By: Prepared By: Approved By: Accepted By:
New 2019-07-19 Ursu, Anamaria
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//system/005570932/... 7/19/2019
Protected System Piping Losses - "E-501A/B Shell/E-502 Tube" - iPRSM / AECOM Page 1 of 1
Connected Equipment
Protected Equipment: OVP Sources: Ancillary Equipment:
E-501A Shell Side
E-501B Shell Side
E-502 Tube Side
Revision History
Rev. Stage: As At: Signoff By: Prepared By: Approved By: Accepted By:
New 2019-07-19 Ursu, Anamaria
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//system/005570932/... 7/19/2019
Piping Loss Details - "E-501A/B Shell/E-502 Tube" - iPRSM / AECOM Page 1 of 1
Revision History
Rev. Stage: As At: Signoff By: Prepared By: Approved By: Accepted By:
New 2019-07-19 Ursu, Anamaria
Rev. Status Rev. # Rev. Stage Rev. Date Prepared By Approved By Accepted By
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//system/005570932/... 7/19/2019
Equipment Data Sheet - ID # SV-530 - iPRSM / AECOM Page 1 of 2
Protected Systems
System Name Rev. Status Rev. # Rev. Stage Rev. Date Prepared By Approved By Accepted By
Parameters
General
Mfgr. Farris Equipment manufacturer
Series Farris 2600 D-U Series for selecting device dependent curves
Orifice Area
API Orf. L - 2.853" API orifice designation
Valve Configuration
dnom_in 3 in Nominal inlet size
Dual outlet
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//equip/005570944/d... 7/19/2019
Equipment Data Sheet - ID # SV-530 - iPRSM / AECOM Page 2 of 2
Dual Outlet No
Process Conditions
Pset 50 psig Set pressure
maxallow% 3% Max allowable inlet pressure drop as % of PSet
Pdrop-in
maxmech
Pback 100 psig Mechanical backpressure limit from manufacturer (for flanges, bellows, etc.)
Options
Cap Undefined Cap construction
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//equip/005570944/d... 7/19/2019
ISA Data Sheet - PRV - ID # SV-530 - iPRSM / AECOM Page 1 of 1
General
Tag #: SV-530 Protected Equipment: NACE Compliant: No
E-501A Shell Side, E-501B Shell Side, E-502 Tube Side
P & ID #: Valve Type: Balanced Bellows
Service: Trim: Vapor/Liquid
Line No.:
Valve Data
ASME
Manufacturer: Model Number: API Designation:
Serial Number: Orifice Area:
Farris 26LB10L L - 2.853"
3.17 in²
Valve Configuration
Inlet Outlet Body: Carbon Steel (SA-216 Gr. WCB) O-Ring: None Opt 1:
Size: 3 in 4 in Bonnet: Carbon Steel (SA-216 Gr. WCB) Spring: Chrome Alloy Opt 2:
Rating: 150 # 150 # Nozzle: 316 SS Bellows: Inconel Composite Opt 3:
Facing: - Raised Face Disk: 316 SS Cap: -
Sizing Basis
Code: ASME Sec. 8 Controlling Contingency: Exchanger Tube Rupture - E-501A -- Tube Rupture - Vapor
Revision History
Status: As At: Last DB Δ By: Last Signoff By:
Checked 2019-07-19 Ursu, Anamaria Ursu, Anamaria
Rev. Status Rev. # Rev. Stage Rev. Date Prepared By Approved By Accepted By
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//equip/005570944/d... 7/19/2019
Equipment Data Sheet - ID # E-501A Shell Side - iPRSM / AECOM Page 1 of 2
Protected Systems
System Name Rev. Status Rev. # Rev. Stage Rev. Date Prepared By Approved By Accepted By
Parameters
General
Mfgr. Equipment manufacturer
Design Criteria
Horizontal Orientation
D 3 ft Diameter
Hgrade 12 ft Height above grade (from lowest point of the shell side)
Hl Unknown ft Normal liquid level (from bottom for horizontal; bottom flange or tangent if vertical)
high Unknown ft High (alarm) liquid level (from bottom for horizontal; bottom flange or tangent if vertical)
Hl
Hl
select Normal Liquid Level Liquid level for use in wetted surface area (fire exposure - liquid vaporization)
Awet
piping Unknown ft² Wetted area of piping
No Select to override plant setting for increase of wetted area for piping (fire exposure - liquid vaporization)
% incr
Awet 0% Percentage increase of wetted area for piping (fire exposure - liquid vaporization)
No Select to override plant setting for increase of exposed area for piping (fire exposure - gas expansion)
% incr 0% Percentage increase of exposed area for piping (fire exposure - gas expansion)
Aexp
HE 172.33 ft² Exposed area of heat exchanger
Aexposed
piping
Aexposed 0 ft² Exposed area of piping
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//equip/005570938/d... 7/19/2019
Equipment Data Sheet - ID # E-501A Shell Side - iPRSM / AECOM Page 2 of 2
Process Parameters
Code ASME Sec. 8 Engineering code stamp
shell
PMAWP 50 psig Shell side MAWP
Environment Factor
Fenv Calc No Insulation Environmental factor calculation method
Notes
2019-07-19 01:45:31 - Anamaria Ursu
Cloned from equipment "[Plant] Denver Test > [Unit] Ursu Anamaria > [Equip't] E-502 Tube Side".
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//equip/005570938/d... 7/19/2019
Equipment Data Sheet - ID # E-501B Shell Side - iPRSM / AECOM Page 1 of 2
Protected Systems
System Name Rev. Status Rev. # Rev. Stage Rev. Date Prepared By Approved By Accepted By
Parameters
General
Mfgr. Equipment manufacturer
Design Criteria
Horizontal Orientation
D 3 ft Diameter
Hgrade 9 ft Height above grade (from lowest point of the shell side)
Hl Unknown ft Normal liquid level (from bottom for horizontal; bottom flange or tangent if vertical)
high Unknown ft High (alarm) liquid level (from bottom for horizontal; bottom flange or tangent if vertical)
Hl
Hl
select Normal Liquid Level Liquid level for use in wetted surface area (fire exposure - liquid vaporization)
Awet
piping Unknown ft² Wetted area of piping
No Select to override plant setting for increase of wetted area for piping (fire exposure - liquid vaporization)
% incr
Awet 0% Percentage increase of wetted area for piping (fire exposure - liquid vaporization)
No Select to override plant setting for increase of exposed area for piping (fire exposure - gas expansion)
% incr 0% Percentage increase of exposed area for piping (fire exposure - gas expansion)
Aexp
HE 172.33 ft² Exposed area of heat exchanger
Aexposed
piping
Aexposed 0 ft² Exposed area of piping
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//equip/005570941/d... 7/19/2019
Equipment Data Sheet - ID # E-501B Shell Side - iPRSM / AECOM Page 2 of 2
Process Parameters
Code ASME Sec. 8 Engineering code stamp
shell
PMAWP 50 psig Shell side MAWP
Environment Factor
Fenv Calc No Insulation Environmental factor calculation method
Notes
2019-07-19 01:49:05 - Anamaria Ursu
Cloned from equipment "[Plant] Denver Test > [Unit] Ursu Anamaria > [Equip't] E-501A Shell Side".
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//equip/005570941/d... 7/19/2019
Equipment Data Sheet - ID # E-502 Tube Side - iPRSM / AECOM Page 1 of 2
Protected Systems
System Name Rev. Status Rev. # Rev. Stage Rev. Date Prepared By Approved By Accepted By
Parameters
General
Mfgr. Equipment manufacturer
Design Criteria
Horizontal Orientation
Hgrade 6 ft Height above grade (from lowest point of the tube side)
outside 0.75 in Outside tube diameter
Dtube
Dchannel 6 ft Diameter of channel section (for varying diameters use the average)
Yes Select to override plant setting for increase of wetted area for piping (fire exposure - liquid
vaporization)
% incr 10 % Percentage increase of wetted area for piping override (fire exposure - liquid vaporization)
Agiven
wet
% incr 10 % Percentage increase of wetted area for piping (fire exposure - liquid vaporization)
Awet
piping 12.252 ft² Wetted area of piping
Awet
No
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//equip/005570935/d... 7/19/2019
Equipment Data Sheet - ID # E-502 Tube Side - iPRSM / AECOM Page 2 of 2
Select to override plant setting for increase of exposed area for piping (fire exposure - gas
expansion)
Aexp
% incr 0% Percentage increase of exposed area for piping (fire exposure - gas expansion)
Process Parameters
Code ASME Sec. 8 Engineering code stamp
tube
PMAWP 50 psig Tube side MAWP
Environment Factor
Fenv Calc No Insulation Environmental factor calculation method
https://i05.iprsm.com/iprsm/aecom.x/$Download/repo/file/serve.p//equip/005570935/d... 7/19/2019