Gas Turbine Generator Package

CENTAUR 40
Turbine type: CENTAUR 40 (T 4701)
Main data (ISO, no losses)

Electrical power: MW 3.51


Heat rate: kJ/kWE-hr 12’900
Fuel input: MJ/s 12.7
Efficiency: % 27.8
Exhaust gas flow: kg/s 19.0
Exhaust gas temp. °C 443
Fuel: NG/LF/LPG/LBTU
Start system: AC
Gen. Voltage: kV 6.3 or 11
Comb. Syst. Avail.: * S/WI/DLE

*S = standard combustion system; WI = water injection; DLE = SoLoNOx

correction curves
4.450 13.600 21,00 455
4.300 13.500 20,50 <--- EGF EGT ---> 450
4.150 <--- kWe HR ---> 13.400
20,00 445
4.000 13.300

Exh. Gas Temperature (°C)


Gen. Output Power (kWe)

19,50 440
Heat Rate (kJ/kWh)

3.850 13.200
Exh. Gas Flow (kg/s)

3.700 13.100 19,00 435

3.550 13.000 18,50 430


3.400 12.900
18,00 425
3.250 12.800
17,50 420
3.100 12.700
2.950 12.600 17,00 415

2.800 12.500 16,50 410


-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40
Engine Inlet Temperature (°C) Engine Inlet Temperature (°C)

typical layout

www.turbomach.com