Final Revised ANNEXURE 2 : Schedule Of Rate (SOR) for ZONE-1

GSPL/PROC/2019/04/O/141 - ANNUAL RATE CONTRACT FOR MECHANICAL MAINTENANCE WORKS IN GSPL GAS GRID PIPELINE NETWORK

S P Construction
Category of Registration in GST(Tick whichever is applicable)
Un Registered
Registered (Normal)
Registered (Composition Levy)

Type of Supply Under this Contract (Tick whichever is applicable)


Normal Supply of goods and services
Mixed supply
Composite supply
Works Contract
mo

Schedule of Rates

Sr No Description Goods/Services HSN (Eight Qty Unit of Measu- Total Basic Amount Rate of GST Total tax amount Gross Amount
digit)/SAC (Six digit) Unit Rate

rement SGST/UTGST CGST IGST CESS


A B C D E G=DXF H I J K L = G x (H+I+K) or M=G+L
F
L = G x (J+K)

Surface preparation of installed(Operational) piping/spool/Fittings, Steel Structural surfaces by Britstle Blaster machine or
other proper methods(Paint\Rust remover equipment) with equipments, accessories, manpower, material etc upto required
surface finish.
The work also includes painting of piping spool including supply of paint and application of 2 coats of red-oxide primer or
1 high build chlorinated rubber/ Polyurethane / Zinc phosphate(as per site condition) of 70 micron each and 2 coats of high 1500 Sq. Mtr. 600000 9 9 108000 708000
build epoxy finished paint of golden/ cannery yellow/any applicable colour instructed by GSPL with 70 micron each of
approved quality including stenciling of line numbers, pipe tagging, flow direction arrow, other lettering as per P&ID/
instruction of GSPL EIC. This includes covering of nut-bolts using masking tape during surface preparation and painting
works.
400

Surface preparation of new piping/spool/Fittings, Steel Structural surfaces Britstle Blaster machine or blasting methods.
Finish of surface quality SA 2 ½ and roughness 60 microns minimum by providing shot/sand of approved quality, shot/sand
blasting equipments & its accessories, manpower, material etc.
The job also includes painting of piping spool including supply of paint and application of 2 coats of red-oxide primer or
2 high build chlorinated rubber/ Polyurethane / Zinc phosphate of 70 micron each and two coats of high build epoxy finished 200 Sq. Mtr. 38000 9 9 6840 44840
paint of golden/ cannery yellow/ any applicable colour instructed by GSPL with 70 micron each of approved quality
including stenciling of line numbers, pipe tagging, flow direction arrow, other lettering as found condition of pipeline as per
instruction of GSPL EIC. This includes covering of nut-bolts using masking tape, during surface preparation & painting
works.

190

Surface preparation of installed DG Canopy/ Panels with Britstle Blaster machine(Paint\Rust remover equipment)
equipments & its accessories, manpower, material etc upto required surface finish.
3 The job also includes spray painting of DG Canopy/ Panels including supply of paint and application of 1 coats of Epoxy 150 Sq. Mtr. 86250 9 9 15525 101775
paint(as per site condition) of 70 micron and two coats of Auto Paint(ASPA)/ PU Paint of 80 micron each of approved
quality including lettering as per instruction of GSPL EIC.
575
Supply and application of Stanvac make Chemcoint RL 500 (Anti Corrosive Coating cum primer) Stanvac make 727
Stangard HP-PLPU (Golden Yellow Top Coat over Chemcoint RL 500 for long lasting corrosion protection) paint in A/G
4 100 Sq. Mtr. 45000 9 9 8100 53100
station piping / valves / fittings / etc. This includes surface preparation, tools, tackels, consumables, transportation,
equipment, manpower, etc. required for execution of job. 450

Painting of Above Ground Civil Supports/Foundations/Earth Pits etc. (Existing/Newly Constructed) including Paint (Terra
5 2500 Sq. Mtr. 250000 9 9 45000 295000
cotta), equipments for application & its accessories, manpower, material etc upto required surface finish.
100

Complete job of repairing the leakage of existing buried pipeline by using leak repair clamps & other accessories related to
clamp. Clamp will be issued by GSPL at designated store. The activity shall include all necessary arrangements, excavation
Location
& backfilling work, material transportation and other works required for leak arrest and restoration of site. Land and corp
compansation will be in GSPL's scope.

2" 1 Location 3500 3500 9 9 630 4130


4" 1 Location 3500 3500 9 9 630 4130
6 6’’ 1 Location 3500 3500 9 9 630 4130
8’’ 1 Location 3500 3500 9 9 630 4130
10" 1 Location 3500 3500 9 9 630 4130
6

12’’ 1 Location 5000 5000 9 9 900 5900


16” 1 Location 5000 5000 9 9 900 5900
18’’ 1 Location 5000 5000 9 9 900 5900
24’’ 1 Location 5000 5000 9 9 900 5900
30” 1 Location 7000 7000 9 9 1260 8260
36’’ 1 Location 7000 7000 9 9 1260 8260
Complete job of repairing the leakage of existing above ground pipeline by using leak repair clamps. Manpower,
equipments and material shifting to site shall be in scope of contractor. Clamps will be provided by GSPL. Restoration of Location
above ground piping as per original conditions.
2" 1 Location 500 500 9 9 90 590
3" 1 Location 500 500 9 9 90 590
4" 1 Location 500 500 9 9 90 590
6’’ 1 Location 1000 1000 9 9 180 1180
7 8’’ 1 Location 1000 1000 9 9 180 1180
10" 1 Location 1500 1500 9 9 270 1770
12’’ 1 Location 1500 1500 9 9 270 1770
16” 1 Location 2000 2000 9 9 360 2360
18’’ 1 Location 2000 2000 9 9 360 2360
24’’ 1 Location 2000 2000 9 9 360 2360
30” 1 Location 2500 2500 9 9 450 2950
36’’ 1 Location 2500 2500 9 9 450 2950
42" 1 Location 2500 2500 9 9 450 2950

Emergency repair of leaking underground pipe by replacement by Pipe spool, or fully encircled sleeve welded on pipe: This
work shall include transportation of Pipes and associated materials from store locations (within Gujarat), loading /
unloading of the line pipes to the site, hydrotest of pipes, excavating the trench for finding out the leakage in the existing
line burst portion of point(This excavation also includes the excavation for replacement of Pipe upto max. 12 meter),
dewatering and cleaning of pit or trench, and to make it free from fire/ accident etc., cutting the line from both ends (upto
Location
one pipe length item, approx 12 Mtr. or part thereof shall be treated as one job ) surface and bevel preparation DP checking
& welding the pipe of the required length on the line, NDT(Radiography,UT,DP) coat and wrap, Holiday testing and back-
filling the same etc. complete the work as directed by E.I.C. Contractor to arrange all necessary equipment, consumables,
manpower etc to complete the job.(Pipes shall be supplied free of cost by GSPL at designated Store)(Nitrogen purging for
the section if required to be claimed seaprately as per SOR.)

8
2" 1 Location 14000 14000 9 9 2520 16520
4" 1 Location 16000 16000 9 9 2880 18880
6’’ 1 Location 18000 18000 9 9 3240 21240
8’’ 1 Location 23000 23000 9 9 4140 27140
10" 1 Location 25000 25000 9 9 4500 29500
12’’ 1 Location 27000 27000 9 9 4860 31860
16” 1 Location 32000 32000 9 9 5760 37760
18’’ 1 Location 35000 35000 9 9 6300 41300
24’’ 1 Location 45000 45000 9 9 8100 53100
30” 1 Location 55000 55000 9 9 9900 64900
36’’ 1 Location 65000 65000 9 9 11700 76700

Repair of metal loss on pipeline at third party damage locations / corrosion / less thickness locations by composite sleeve
(Clock Spring). The job includes excavation & restoration , clearing of pit, dewatering, removal of coating, preparation the
pipe surface to put sleeve. The job also includes the supply of coating materials & repair of damaged coating, Holiday
Testing and, back filling with soft soil and final cleanup to restore the field to its original conditions. PAUT/UT for anomaly
assessment at damaged location before application of composite wrap shall be in the scope of contractor. Land and corp
compansation will be in GSPL's scope. It is considered that sleeve width will be 300 mm std.

2" 2 Location 38000 76000 9 9 13680 89680


9 4" 2 Location 78000 156000 9 9 28080 184080
6’’ 4 Location 88000 352000 9 9 63360 415360
8’’ 2 Location 108000 216000 9 9 38880 254880
10" 1 Location 118000 118000 9 9 21240 139240
12’’ 6 Location 138000 828000 9 9 149040 977040
16” 1 Location 148000 148000 9 9 26640 174640
18’’ 8 Location 168000 1344000 9 9 241920 1585920
24’’ 12 Location 198000 2376000 9 9 427680 2803680
30” 4 Location 208000 832000 9 9 149760 981760
36’’ 1 Location 218000 218000 9 9 39240 257240
Repair of Pipeline / Flange / RTD Thermowell/IJ/Valves Body at leakage portion or less thickness locations by supply and
application of Nicco - Fermanite clamp or any other leak clamp which can be installed on line and injecting sealing
material. The job includes cleaning of pipeline / flange / RTD Thermowell/IJ/Valves, installation of Nicco - Fermanite
clamp or any other leak clamp which can be installed on line and injecting sealing material on pipes of dia 2" / 4" / 6”/ 8” / Location
10"/ 12”. The job includes the painting of pipeline / flange / RTD Thermowell/IJ/Valves and restore the field to its original
conditions. The job includes man-power, transportation and other resources. This job shall be carried out by certified OEM /
vendor only.
10

upto 2’’ 8 Location 14000 112000 9 9 20160 132160


2" to 4’’ 2 Location 14000 28000 9 9 5040 33040
6’’ 8 Location 14000 112000 9 9 20160 132160
8’’ 6 Location 19000 114000 9 9 20520 134520
10’’ 4 Location 25000 100000 9 9 18000 118000
12’’ 4 Location 27000 108000 9 9 19440 127440
Peel-off test on existing buried pipeline to check the health of pipeline and corrosion on pipe surface. Job includes
excavation & backfilling of required size. After inspection, cleaning, coating repair, holiday check, back filling and final
cleanup. etc, as per drawing and direction of E.I.C. Survey is to be carried out on pipelines of dia. 6”, 8’’, 10", 12’’, 16", Location
11 18’’, 24’’, 30”,36" including man power, transporation, machinery, peel-off test equipment, temperature gun, etc.

Soft soil 8 Per Pit 8000 64000 9 9 11520 75520


Rocky area 4 Per Pit 10000 40000 9 9 7200 47200

Dismantling & removing the existing installed equipment such as DG Set, Metering skid, Filter, Filteration skid, PRS skid,
Pig Barrel, Pig Trolly, Jib Crane, Piping,electrical/ instrumentation panel, valves, structural steel etc. carefully including
handling, loosing the nuts, bolt cutting etc(if required) and stacking the equipments/ material within a radius of 250 Mts.
and as directed by EIC.
Manpower, Machinery required, transportation is in contractor's scope.

12 Item weight upto 50 kg 100 Lumsum 1500 150000 9 9 27000 177000


Item weight upto 51-150 kg 70 Lumsum 4000 280000 9 9 50400 330400
Item weight upto 151-250 kg 40 Lumsum 6500 260000 9 9 46800 306800
Item weight upto 251-500 kg 20 Lumsum 12000 240000 9 9 43200 283200
Item weight upto 501-1000 kg 10 Lumsum 14000 140000 9 9 25200 165200
Item weight upto 1 Ton - 2 Tonnes 10 Lumsum 15000 150000 9 9 27000 177000
Item weight upto 2-Tonnes- 3 Tonnes 5 Lumsum 15500 77500 9 9 13950 91450
Installation of equipment such as DG Set, Metering skid, Filter, Filteration skid, PRS skid, Pig Barrel, Pig Trolly, Jib Crane,
Piping,electrical/ instrumentation panel, valves, structural steel etc. carefully including handling, erection and proper
installtion of the equipments/ material within a radius of 250 Mts. and as directed by EIC.
Manpower, Machinery required, transportation is in contractor's scope.
Item weight upto 50 kg 100 Lumsum 1500 150000 9 9 27000 177000
13 Item weight upto 51-150 kg 70 Lumsum 4000 280000 9 9 50400 330400
Item weight upto 151-250 kg 40 Lumsum 6500 260000 9 9 46800 306800
Item weight upto 251-500 kg 20 Lumsum 12000 240000 9 9 43200 283200
Item weight upto 501-1000 kg 10 Lumsum 14000 140000 9 9 25200 165200
Item weight upto 1 Ton - 2 Tonnes 10 Lumsum 15000 150000 9 9 27000 177000
Item weight upto 2-Tonnes- 3 Tonnes 5 Lumsum 15500 77500 9 9 13950 91450
Installation of above ground valves(Ball/Glove/ Check) of various sizes in piping system including handling, blind removal
providing temporary supports if necessary, Studs bolt loosening / tightening, gasket insertion and torque setting with all
tools/tackles/manpower etc. of valves sizes, Hydra and other lifting equipment inclusive of scaffolding arrangement at site if
required including valve operation. Gasket shall be provided by GSPL.
Up to & including 1” NB 40 Nos. 475 19000 9 9 3420 22420
1 ½” to 2’’ NB 50 Nos. 475 23750 9 9 4275 28025
3”NB 6 Nos. 750 4500 9 9 810 5310
4’’NB 6 Nos. 1250 7500 9 9 1350 8850
14 6’’NB 4 Nos. 5000 20000 9 9 3600 23600
8’’NB 5 Nos. 5500 27500 9 9 4950 32450
10"NB 1 Nos. 5800 5800 9 9 1044 6844
12’’NB 3 Nos. 6300 18900 9 9 3402 22302
16”NB 1 Nos. 6400 6400 9 9 1152 7552
18’’NB 1 Nos. 6800 6800 9 9 1224 8024
24’’NB 1 Nos. 8800 8800 9 9 1584 10384
30’’NB 1 Nos. 8800 8800 9 9 1584 10384
36’’NB 1 Nos. 8800 8800 9 9 1584 10384
Dismantling of valves(Ball/Globe/Check) from the line and putting blinds / spool pieces etc., for various pipe sizes etc.
including Stud bolt loosening, gasket changing, handling with all tools / tackles / manpower etc. of valves sizes. Gasket
shall be provided by GSPL.
Up to & including 1” NB 10 Nos. 475 4750 9 9 855 5605
1 ½” to 2’’ NB 30 Nos. 475 14250 9 9 2565 16815
3’’ NB 4 Nos. 1200 4800 9 9 864 5664
4’’ NB 4 Nos. 3000 12000 9 9 2160 14160
6’’ NB 10 Nos. 4000 40000 9 9 7200 47200
15
8’’ NB 6 Nos. 4800 28800 9 9 5184 33984
10" NB 1 Nos. 5200 5200 9 9 936 6136
15

12’’ NB 4 Nos. 5600 22400 9 9 4032 26432


16” NB 1 Nos. 5800 5800 9 9 1044 6844
18’’ NB 2 Nos. 6330 12660 9 9 2278.8 14938.8
24’’ NB 2 Nos. 8800 17600 9 9 3168 20768
30’’ NB 1 Nos. 9000 9000 9 9 1620 10620
36’’ NB 1 Nos. 9000 9000 9 9 1620 10620
Dismantling or Instllation of Blind Flanges from A/G piping for various pipe sizes including nut bolt removing & handling
with all tools / tackles / manpower/machinery & consumables etc. and stacking all within radius of 250 Mts as per GSPL
EIC instructions.
upto 2’’ 20 Nos. 300 6000 9 9 1080 7080
16
From 3" to 6" 6 Nos. 500 3000 9 9 540 3540
From 8" to 12" 5 Nos. 2000 10000 9 9 1800 11800
From 16" to 24" 1 Nos. 5000 5000 9 9 900 5900
From 30" to 36" 1 Nos. 6000 6000 9 9 1080 7080
Reversal of Spectacle Blind on installed A/G Piping for various sizes etc. including nut bolt loosening, gasket changing with
all tools / tackles / manpower etc. of valves sizes:-
Up to & including 1” NB 2 Nos. 200 400 9 9 72 472
1 ½” to 2’’ NB 6 Nos. 200 1200 9 9 216 1416
3’’ NB 4 Nos. 300 1200 9 9 216 1416
4’’ NB 6 Nos. 300 1800 9 9 324 2124
6’’ NB 10 Nos. 500 5000 9 9 900 5900
17 8’’ NB 10 Nos. 500 5000 9 9 900 5900
10" NB 2 Nos. 1000 2000 9 9 360 2360
12’’ NB 8 Nos. 1200 9600 9 9 1728 11328
16” NB 1 Nos. 5000 5000 9 9 900 5900
18’’ NB 12 Nos. 5000 60000 9 9 10800 70800
24’’ NB 20 Nos. 5500 110000 9 9 19800 129800
30’’ NB 12 Nos. 7500 90000 9 9 16200 106200
36’’ NB 1 Nos. 7500 7500 9 9 1350 8850
Gas cutting, grinding and bevelling of various diameter station pipes of Sch-80 (Sch-160 upto 2" pipe). The job inclusive of
all manpower, transportation, consumables, equipments, tools etc.
upto 3’’ 30 Inch. Dia. 400 12000 9 9 2160 14160
From 4" to 6" 10 Inch. Dia. 400 4000 9 9 720 4720
18
From 8" to 10" 4 Inch. Dia. 400 1600 9 9 288 1888
From 12" to 16" 40 Inch. Dia. 400 16000 9 9 2880 18880
From 18" to 24" 1 Inch. Dia. 500 500 9 9 90 590
From 30" to 36" 1 Inch. Dia. 500 500 9 9 90 590

Fabrication and installation of Underground Casing Pipes IS-3589:2001 Fe-410/or IS2062 equivalent grade of different
thickness or schedule. Job Includes transportation of free issue casing Pipe from GSPL designated store to site, handling,
Horizontal Cutting at both sides of Casing Pipes as well as Circumferencial Cutting of Casing Pipes, beveling /edge
preparation of Longitudnal direction & Circumferencial Direction, aligning, installation of Casing Insulators, Sand Filling,
Mud Application, fit-up, tie-in, welding at both sides of pipes in longitudnal direction as well as Circumferencial Joints, DP,
temporary supporting etc. Bentonite Filling, Dewatering, installation of end seals & Painting of Casing Pipe. Excavation
upto required depth & Back-filling of the same after successful completion is also included in the scope. All the tool &
tackels, equipments, hydra, mud pump and supply & installation of required size casing insulator, vent & drain pipes of
suitable size shall be included in this SOR. (Supply of Casing Pipes are in scope of GSPL & will be issued at designated
GSPL stores). Pemission for excavation and Land / Corp compansation shall be in scope of GSPL.

Casing Size 12" Dia. (Normal Soil) 1 R. Mtr. 8000 8000 9 9 1440 9440
19 Casing Size 12" Dia. (Rocky Soil) 1 R. Mtr. 8400 8400 9 9 1512 9912
Casing Size 16" Dia.(Normal Soil) 1 R. Mtr. 9000 9000 9 9 1620 10620
Casing Size 16" Dia. (Rocky Soil) 1 R. Mtr. 9400 9400 9 9 1692 11092
Casing Size 18" Dia. (Normal Soil) 1 R. Mtr. 10000 10000 9 9 1800 11800
Casing Size 18" Dia. (Rocky Soil) 1 R. Mtr. 10400 10400 9 9 1872 12272
Casing Size 20" Dia. (Normal Soil) 1 R. Mtr. 11000 11000 9 9 1980 12980
Casing Size 20" Dia. (Rocky Soil) 1 R. Mtr. 11500 11500 9 9 2070 13570
Casing Size 24" Dia. (Normal Soil) 1 R. Mtr. 13000 13000 9 9 2340 15340
Casing Size 24" Dia. (Rocky Soil) 1 R. Mtr. 13500 13500 9 9 2430 15930
Casing Size 30" Dia. (Normal Soil) 1 R. Mtr. 14000 14000 9 9 2520 16520
Casing Size 30" Dia. (Rocky Soil) 1 R. Mtr. 14500 14500 9 9 2610 17110
Casing Size 36" Dia. (Normal Soil) 1 R. Mtr. 15000 15000 9 9 2700 17700
Casing Size 36" Dia. (Rocky Soil) 1 R. Mtr. 15500 15500 9 9 2790 18290
Casing Size 42" Dia. (Normal Soil) 1 R. Mtr. 16000 16000 9 9 2880 18880
Casing Size 42" Dia. (Rocky Soil) 1 R. Mtr. 16500 16500 9 9 2970 19470
Dismantling / Revomal of existing Underground Casing Pipes installed on Existing Operational Pipelines.
Job Includes excavation of the earth work upto existing pipeline/casing pipe, removal of End seals, Horizontal Cutting at
both sides of Casing Pipes as well as Circumferencial Cutting of Casing Pipes, removal of Casing Insulators, removal of
Mud,removal of bentonite/mud and disposal of the same at suitable place as per GPCB/CPCB norms, use of water jet for
cleaning the carier pipe, cutting of drain & vent pipes, transportation of removed Casing Pipes to GSPL store/designated
location, Dewatering if required, holiday testing, repair of damaged coating, holiday testing after repair, Back-filling &
restoration of the same after successful completion of job.

Casing Size 12" Dia. (Normal Soil) 1 R. Mtr. 6000 6000 9 9 1080 7080
Casing Size 12" Dia. (Rocky Soil) 1 R. Mtr. 6200 6200 9 9 1116 7316
Casing Size 16" Dia.(Normal Soil) 1 R. Mtr. 6500 6500 9 9 1170 7670
20
Casing Size 16" Dia. (Rocky Soil) 1 R. Mtr. 6700 6700 9 9 1206 7906
Casing Size 18" Dia. (Normal Soil) 1 R. Mtr. 7000 7000 9 9 1260 8260
Casing Size 18" Dia. (Rocky Soil) 1 R. Mtr. 7200 7200 9 9 1296 8496
Casing Size 20" Dia. (Normal Soil) 1 R. Mtr. 7300 7300 9 9 1314 8614
Casing Size 20" Dia. (Rocky Soil) 1 R. Mtr. 7500 7500 9 9 1350 8850
Casing Size 24" Dia. (Normal Soil) 1 R. Mtr. 7500 7500 9 9 1350 8850
Casing Size 24" Dia. (Rocky Soil) 1 R. Mtr. 7700 7700 9 9 1386 9086
Casing Size 30" Dia. (Normal Soil) 1 R. Mtr. 7800 7800 9 9 1404 9204
Casing Size 30" Dia. (Rocky Soil) 1 R. Mtr. 8000 8000 9 9 1440 9440
Casing Size 36" Dia. (Normal Soil) 1 R. Mtr. 8000 8000 9 9 1440 9440
Casing Size 36" Dia. (Rocky Soil) 1 R. Mtr. 8200 8200 9 9 1476 9676
Casing Size 42" Dia. (Normal Soil) 1 R. Mtr. 8500 8500 9 9 1530 10030
Casing Size 42" Dia. (Rocky Soil) 1 R. Mtr. 8800 8800 9 9 1584 10384
Removal of gear box from Valve((Ball/Globe/Check), dismantling of Gear box, replacement of required packing, proper
cleaning, greasing of the same with Multipurpose grease & re-installation of gear box for various Valve sizes including
supply of multipurpose grease, handling, packing materials, nut bolt loosening, gasket changing with all tools / tackles /
manpower etc. of different valves sizes .
4’’ NB 20 Nos. 1000 20000 9 9 3600 23600
21
6’’ NB 10 Nos. 1200 12000 9 9 2160 14160
8’’ NB 10 Nos. 1300 13000 9 9 2340 15340
10" NB 2 Nos. 1600 3200 9 9 576 3776
12’’ NB 2 Nos. 1800 3600 9 9 648 4248
16” NB 1 Nos. 2000 2000 9 9 360 2360

Online servicing of gear box by cleaning of the housing, filiing with MP Grease. Sevicing of the Stem & Spindle of the
Globe Valve by cleaning with emery Paper & application of multi purpose Graese.

4’’ NB 1 Nos. 1000 1000 9 9 180 1180


22 6’’ NB 1 Nos. 1200 1200 9 9 216 1416
8’’ NB 1 Nos. 1300 1300 9 9 234 1534
10" NB 1 Nos. 1600 1600 9 9 288 1888
12’’ NB 1 Nos. 1800 1800 9 9 324 2124
16” NB 1 Nos. 2000 2000 9 9 360 2360
Dismantling of piping spool along with flanges from line for various pipe sizes and putting blind including nut bolt
removing & handling with all tools / tackles / manpower/machinery etc and stacking all within radius of 250Mts as per
GSPL EIC instructions.(No separate charges shall be paid extra for manpower & equipments used)
Up to 2’’ NB 50 R. Mtr. 480 24000 9 9 4320 28320
3’’ NB 6 R. Mtr. 580 3480 9 9 626.4 4106.4
4’’ NB 20 R. Mtr. 780 15600 9 9 2808 18408
6’’ NB 20 R. Mtr. 900 18000 9 9 3240 21240
23
8’’ NB 15 R. Mtr. 1100 16500 9 9 2970 19470
10" NB 30 R. Mtr. 1300 39000 9 9 7020 46020
12’’ NB 25 R. Mtr. 1400 35000 9 9 6300 41300
18’’ NB 1 R. Mtr. 2200 2200 9 9 396 2596
24’’ NB 1 R. Mtr. 2200 2200 9 9 396 2596
30" NB 1 R. Mtr. 2500 2500 9 9 450 2950
36’’NB 1 R. Mtr. 2500 2500 9 9 450 2950
Installation of piping spool along with flanges for various pipe sizes including blind removal, nut bolt removing & handling
with all tools / tackles / manpower/ machinery etc as per GSPL EIC instructions.(No separate charges shall be paid extra for
manpower & equipments used)
up to 2’’ NB 80 R. Mtr. 480 38400 9 9 6912 45312
3’’ NB 10 R. Mtr. 580 5800 9 9 1044 6844
4’’ NB 10 R. Mtr. 780 7800 9 9 1404 9204
6’’ NB 40 R. Mtr. 780 31200 9 9 5616 36816
24
8’’ NB 15 R. Mtr. 950 14250 9 9 2565 16815
10" NB 6 R. Mtr. 1180 7080 9 9 1274.4 8354.4
12’’ NB 20 R. Mtr. 1280 25600 9 9 4608 30208
18’’ NB 1 R. Mtr. 2200 2200 9 9 396 2596
24’’ NB 1 R. Mtr. 2200 2200 9 9 396 2596
30" NB 1 R. Mtr. 2500 2500 9 9 450 2950
36’’NB 1 R. Mtr. 2500 2500 9 9 450 2950
Gas cutting, grinding and welding of edges of chequered plate installed in cable trenches, valve pit etc. including handling.
25 20 R. Mtr. 6000 9 9 1080 7080
The job inclusive of all consumables, equipments, tools, labour etc. 300
Supply and Installation of chequered plate of required size for trenches, platforms etc including application of red oxide
primer and two coats of finish paint of approved quality.(No separate charges shall be paid for gas cutting, grinding &
welding of edges of chequered palte & transportation of the same) The job inclusive of all consumables, equipments, tools,
26 labour etc.
4 mm thick 10 Sq. Mtr. 4000 40000 9 9 7200 47200
6 mm thick 4 Sq. Mtr. 6000 24000 9 9 4320 28320
8 mm thick 4 Sq. Mtr. 7000 28000 9 9 5040 33040
Providing and fixing pre coated galvanized G.I. Sheet of approved colour on roofing and sides of Metering system or DG
Sets as per manufacturer’s instructions including providing sealant in the overlapping portion of sheets complete and
27 including all accessories.
0.6 mm thick trapezoidal profile 80 Sq. Mtr. 680 54400 9 9 9792 64192
0.6 mm thick corrugated profile 150 Sq. Mtr. 680 102000 9 9 18360 120360
Providing & fixing hand railing with Class-B pipes on equipments like filter, PRS, operating platforms, buildings etc. The
28 job includes surface cleaning, supply and application of two coats of red oxide primer and two coats of finish paint of 100 Mtr. 63500 9 9 11430 74930
approved quality. The job is to be executed as per the direction of the E.I.C. 635
Replacement by removing old gaskets including tightening and loosing of Flanges with all tools / tackles / manpower/
machinery etc as per GSPL EIC instructions.
Gasket shall be provided by GSPL at designated store.
up to 2’’ NB 80 Nos. 300 24000 9 9 4320 28320
3’’ NB 10 Nos. 300 3000 9 9 540 3540
4’’ NB 4 Nos. 300 1200 9 9 216 1416
6’’ NB 5 Nos. 500 2500 9 9 450 2950
29 8’’ NB 2 Nos. 500 1000 9 9 180 1180
10" NB 2 Nos. 550 1100 9 9 198 1298
12’’ NB 10 Nos. 650 6500 9 9 1170 7670
16’’ NB 2 Nos. 1000 2000 9 9 360 2360
18’’ NB 1 Nos. 1100 1100 9 9 198 1298
24’’ NB 4 Nos. 1200 4800 9 9 864 5664
30" NB 1 Nos. 1200 1200 9 9 216 1416
36’’NB 1 Nos. 1200 1200 9 9 216 1416
Maintenance of Filter: Valve Operations, Opening of filters, cleaning of filter elements/re-placement of the filter elements
and box-up. The job is including valve operation for filter isolation & Venting, nitrogen purging and the air-blowing of filter
element with compressed air, drying them in open yard for 3 hours, reinstall them if required change with new elements as
per instruction of GSPL EIC. Activity Inclusive of the Nitrogen purging with max. 7 M3 by using certified N2 Pressure
Regulator from Cylinder. The job inclusive of all consumables, equipments, tools, Manpower, transportation of filter
elements from designated store.
Size upto 8" QOEC Type 50 Nos. 5000 250000 9 9 45000 295000
Size upto 8" Flanged Door Type 10 Nos. 5500 55000 9 9 9900 64900
Size from 10" to 12" QOEC Type 50 Nos. 5500 275000 9 9 49500 324500
Size from 10" to 12" Flanged Door Type 10 Nos. 6000 60000 9 9 10800 70800
30
Size from 14" to 18" QOEC Type 10 Nos. 8000 80000 9 9 14400 94400
Size from 14" to 18" Flanged Door Type 2 Nos. 8500 17000 9 9 3060 20060
24" QOEC Type 10 Nos. 10000 100000 9 9 18000 118000
24" Flanged Door Type 2 Nos. 10000 20000 9 9 3600 23600
28" QOEC Type 2 Nos. 10000 20000 9 9 3600 23600
28" Flanged Door Type 1 Nos. 10000 10000 9 9 1800 11800
Size 28" to 50" QOEC Type 5 Nos. 11000 55000 9 9 9900 64900
Size 28" to50" Flanged Door Type 2 Nos. 11000 22000 9 9 3960 25960
Size 52" to 70" QOEC Type 2 Nos. 12000 24000 9 9 4320 28320
Size 52" to 70" Flanged Door Type 1 Nos. 12000 12000 9 9 2160 14160
Maintenance of Pig launcher/ receiver: Opening, cleaning and box-up of pig launcher / receiver of below sizes, including
cleaning & replacement of "O" ring if required. Job includes supply & purging of N2.The job is including valve operation
for Isolation & venting.
31
Size upto 18" 16 Nos. 9000 144000 9 9 25920 169920
Size from 20" to 36" 12 Nos. 10000 120000 9 9 21600 141600
Size from 40" & above 1 Nos. 15000 15000 9 9 2700 17700
Welding and laying of under ground pipeline up to 150 meters (with cover of 1.5 meters) with all manpower, machinary,
consumables, NDT, Coating, Restoration, Hydro Testing, Swabbing, Drying, N2 purging, Commissioning and related
documentation and As-Built drawings
2”NB 1 R. Mtr. 3500 3500 9 9 630 4130
4”NB 1 R. Mtr. 4500 4500 9 9 810 5310
6” NB 1 R. Mtr. 5000 5000 9 9 900 5900
32 8” NB 1 R. Mtr. 5500 5500 9 9 990 6490
12” NB 1 R. Mtr. 6000 6000 9 9 1080 7080
16” NB 1 R. Mtr. 7000 7000 9 9 1260 8260
18” NB 1 R. Mtr. 8000 8000 9 9 1440 9440
24” NB 1 R. Mtr. 10000 10000 9 9 1800 11800
30” NB 1 R. Mtr. 12000 12000 9 9 2160 14160
36” NB 1 R. Mtr. 14000 14000 9 9 2520 16520
Fabrication and installation of Above ground piping of grade ASTM A333 Gr.6 / API 5L/X65 & equivalent grade of
different schedule including, handling, aligning, cutting, beveling /edge preparation, installation of associated fittings /
flanges, fit-up, tie-in, welding, Radiography ,UT, DP, transportation of fabricated spool to location, temporary supporting,
erection of different size of fabricated aboveground piping at all elevations including handling, temporary supporting etc.
The job includes carrying out hydrostatic testing as per GSPL approved procedure of completed Piping loop / Piping system
as approved by Owner / Owner’s Representative to the specified pressures, providing all testing equipments / instruments /
accessories, blind etc. including Pressure recorder, Temperature probe, Temperature recorder. Dewatering, surface
preparation & painting of Spool after successful completion of hydro testing is also including in scope. (Pipe/ pipefittings
shall be issued by GSPL at designated store.)

Pipe Wall thickness ranging upto 6.4 mm 200 Inch. Dia. 1300 260000 9 9 46800 306800
Pipe Wall thickness ranging from 6.4 mm– 8.56 mm 250 Inch. Dia. 1600 400000 9 9 72000 472000
Pipe Wall thickness ranging from 8.57 mm– 17.4 mm 500 Inch. Dia. 2100 1050000 9 9 189000 1239000
Pipe Wall thickness ranging from 17.5 mm– 32 mm 150 Inch. Dia. 2300 345000 9 9 62100 407100
PQR laboratory charges for 2” WPS 1 Nos. 2540 2540 9 9 457.2 2997.2
33 PQR laboratory charges for 4” WPS 1 Nos. 3810 3810 9 9 685.8 4495.8
PQR laboratory charges for 8” WPS 1 Nos. 6350 6350 9 9 1143 7493
PQR laboratory charges for 12” WPS 1 Nos. 9500 9500 9 9 1710 11210
PQR laboratory charges for 18” WPS 1 Nos. 10500 10500 9 9 1890 12390
EQT for 24 MM MS plate (SMAW) 1 Nos. 6350 6350 9 9 1143 7493
EQT for 24 MM MS plate (GTAW) 1 Nos. 7000 7000 9 9 1260 8260
EQT for 16 MM MS plate (SMAW) 1 Nos. 6500 6500 9 9 1170 7670
EQT for 16 MM MS plate (GTAW) 1 Nos. 6500 6500 9 9 1170 7670
NDT charges for 2” WPS 1 Nos. 500 500 9 9 90 590
NDT charges for 4” WPS 1 Nos. 650 650 9 9 117 767
NDT charges for 8” WPS 1 Nos. 750 750 9 9 135 885
NDT charges for 12” WPS 1 Nos. 900 900 9 9 162 1062
NDT charges for 18” WPS 1 Nos. 1100 1100 9 9 198 1298
NDT charges for EQT (24 MM plate) 1 Nos. 900 900 9 9 162 1062
NDT charges for EQT (16 MM plate 1 Nos. 900 900 9 9 162 1062

Supply and application for field joint coating of field weld joints of different size as mentioned below, with HEAT
SHRINKABLE Sleeves / DENSO MAKE/R-95 EPOXY tape at all the weld Joints for underground pipeline as per the
Owner’s specification. The job includes the preparation of trenches for joint coating, surface preparation by mechanical
cleaning through power brush, edge preparation, pre-heating of surface, primer application, wrapping of sleeve/tape,
holiday test etc. The supply of all consumables, utilities, equipment, and all manpower required, pipe cleaning and surface
preparation and testing including all handling, transportation, etc. included in this schedule of item.
34
DENSO/RayChem Make tape 30 Sq. Mtr. 4500 135000 9 9 24300 159300
R-95 EPOXY 20 Litres 6000 120000 9 9 21600 141600
Coating Repair PERP HTLP 80 6 Sq. Mtr. 7500 45000 9 9 8100 53100
coating repair filling material Mastic 4 Sq. Mtr. 2500 10000 9 9 1800 11800
HEAT SHRINKABLE Sleeve upto 8" dia 1 Sq. Mtr. 2500 2500 9 9 450 2950
HEAT SHRINKABLE Sleeve from 10" to 18" dia 1 Sq. Mtr. 3400 3400 9 9 612 4012
HEAT SHRINKABLE Sleeve from 24" to 36" dia 1 Sq. Mtr. 3500 3500 9 9 630 4130

Re-conditioning of coating of underground gas pipeline after “locating the pipeline (in the scope of the contractor)” by
suitable method (Pipeline Locator / trial pit method / Pipeline markers etc) as per the coating fault. The activity includes (a)
Excavation to expose the line to suitable depth to expose the pipeline and provide working space around the pipeline.
(b)Removal of existing coating by using scrappers etc. and cleaning the surface to fine finishes by power brush / suitable
method.(c) Rectification of Coating of the defects by HEAT SHRINKABLE /DENSO MAKE after surface preparation by
mechanical cleaning, primer application, wrapping of tape, edge preparation, holiday test etc.(d)Back filling the trenches
and restoring the fields to the satisfaction of GSPL. Cleaning ROU of any debris etc.(e) The supply of all consumables,
35 utilities, equipment, and all manpower required, pipe cleaning and surface preparation, repairing of coating defects
(resulting in holiday in coating) and testing including all handling, transportation, etc. included in this schedule of item.
(f)any crop compensation to the land owner / farmers shall be in the scope of GSPL. (No separate charges shall be paid for
manpower, consumables, equipments, tools used for this activity)

DENSO / RayChem MAKE TAPE 100 Sq. Mtr. 4800 480000 9 9 86400 566400
HEAT SHRINKABLE Sleeve 6 Sq. Mtr. 5000 30000 9 9 5400 35400
COATING REPAIR PERP HTLP 80 8 Sq. Mtr. 6600 52800 9 9 9504 62304
COATING REPAIR FILLING MATERIAL MASTIC 6 Sq. Mtr. 2500 15000 9 9 2700 17700
Condition Checking of underground sectionalizing Valves including it's by-pass valves and associated underground piping.
The job includes
a) Removal of gravels, Excavation( (Removal of gravel from Process Area, Manual Excavation) and making trench of
appropriate size, required for checking of valves and under ground piping. Excavation to be carried out segragating sand,
gravel, mud, PVC so that backfilling can be done appropriately. Thickness measurement of valve body as well as
underground piping,
b) Reconditioning of coating using R-95 Epoxy or equivalent coating to be claimed as per relevant SOR (Supply &
Application).
c) Holiday test for the valve body and underground piping
d) Backfilling & restoration as found condition,
e) This include removal and re-installation of PT/TT/PGD stand, if required.
36
f) The supply of all consumables, utilities, equipment, and all manpower required, valve cleaning and surface preparation,
repairing of coating defects (resulting in holiday in coating) and testing including all handling, transportation, etc. included
in this schedule of item. This includes Supply & replacement of Polythelene sheet (sheet 0.5 mm thk) during the course of
valve checking.

12’’ NB 1 Nos. 8000 8000 9 9 1440 9440


16’’ NB 1 Nos. 8500 8500 9 9 1530 10030
18’’ NB 1 Nos. 8500 8500 9 9 1530 10030
24’’ NB 1 Nos. 8500 8500 9 9 1530 10030
30" NB 1 Nos. 8500 8500 9 9 1530 10030
36’’ NB 1 Nos. 8500 8500 9 9 1530 10030

Condition Checking of underground Tap-off Valves including it's by-pass/equilizing valves and associated underground
piping. The job includes
a) Removal of gravels, Excavation and making trench of appropriate size, required for checking of valves and under ground
piping. Thickness measurement of valve body as well as underground piping,
b) Reconditioning of coating using R-95 Epoxy or equivalent coating to be claimed as per relevant SOR (Supply &
Application).
c) Holiday test for the valve body and underground piping
d) Backfilling & restoration as found condition,
e) The supply of all consumables, utilities, equipment, and all manpower required, valve cleaning and surface preparation,
37 and testing including all handling, transportation, etc. included in this schedule of item. This SOR also includes Supply &
replacement of Polythelene sheet (sheet 0.5 mm thk) during the course of valve checking.

6’’ NB 1 Nos. 12000 12000 9 9 2160 14160


8’’ NB 1 Nos. 12000 12000 9 9 2160 14160
10’’ NB 1 Nos. 12000 12000 9 9 2160 14160
12’’ NB 1 Nos. 12000 12000 9 9 2160 14160
18" NB 1 Nos. 12000 12000 9 9 2160 14160
24" NB 1 Nos. 12000 12000 9 9 2160 14160
36’’ NB 1 Nos. 12000 12000 9 9 2160 14160
Supply and lay of Polythene sheet for process area. This includes removal of gravel & sieving & backfilling the same gravel
38 100 Sq. Mtr. 25000 9 9 4500 29500
after laying of Polythelene sheet of 0.5 mm thick 250

Checking of above ground pipeline supports by lifting the pipe section, providing temporary supports by standard
Engineering practises and rectification measures like application of paint to be carried out and fibre sheet of proper
dimension shall be placed. Any rectification in support shall be paid as per the relevant SOR. (Measurement shall be done
on the basis of Dia of Pipeline and Nos. of Support to be checked) No separate charges shall be paid for Manpower, Tools &
Tackles, consumbles used for this activities.

2”NB 4 Per support 500 2000 9 9 360 2360


3”NB 6 Per support 700 4200 9 9 756 4956
39 4”NB 6 Per support 900 5400 9 9 972 6372
6” NB 6 Per support 1200 7200 9 9 1296 8496
8” NB 4 Per support 1800 7200 9 9 1296 8496
10” NB 8 Per support 2000 16000 9 9 2880 18880
12” NB 6 Per support 2000 12000 9 9 2160 14160
16” NB 1 Per support 2000 2000 9 9 360 2360
18” NB 2 Per support 2200 4400 9 9 792 5192
24” NB 1 Per support 2500 2500 9 9 450 2950
30” NB 4 Per support 2500 10000 9 9 1800 11800
36” NB 1 Per support 2500 2500 9 9 450 2950
Dismantling and taking out of submersible pump-motor of rating 3KW / 5 KW from bore well, retaining and rolling of
power cable pulled out from bore well. And reinstallation of repaired motor and associated assembly back into the bore in
complete working condition. The rate for repairing of damages in the system shall be paid as per list below. All the tools
tackles, manpower, tripod, fasteners etc. required for the job is included in the scope.
Rewinding 1 Nos. 4500 4500 9 9 810 5310
a) 3 KW 6 Nos. 7000 42000 9 9 7560 49560
B) above 3KW to 5 KW 3 Nos. 8000 24000 9 9 4320 28320
above 5KW to 15 KW 1 Nos. 10000 10000 9 9 1800 11800
40
Rectificaiton/Replacement of mechanical damage of pump 3 Nos. 8000 24000 9 9 4320 28320
Flat strip cable 100 Mtr. 180 18000 9 9 3240 21240
Supply and installation of Casing PVC pipe of required diameter
a) 6" 30 Mtr. 450 13500 9 9 2430 15930
b) 8" 4 Mtr. 490 1960 9 9 352.8 2312.8
Supply and Installation of Pump Pipe UPVC of required diameter
a) 1" 100 Mtr. 380 38000 9 9 6840 44840
b) 2" 50 Mtr. 390 19500 9 9 3510 23010

Providing & drilling the Bore well by means of mechanically suitable method prescribed in IS: 2800 (Part-I) of required dia,
having minimum depth of 50 Mtr. below clear water level at the location approved by Client/ Consultant, including all the
necessary labor, PVC casing confirm to IS: 12818, paddle flanges. waste, debris from/due to bore well to be removed &
41 make good upon completion of the works. Work includes but not limited to Gravel packing of suitable size, Mud pit
arrangement.

a) borehole including 6" dia PVC casing 1 Mtr. 830 830 9 9 149.4 979.4
b) borehole including 8" dia PVC casing 1 Mtr. 850 850 9 9 153 1003
Providing & drilling the Bore well by means of mechanically suitable method prescribed in IS: 2800 (Part-I) of required dia,
having minimum depth of beyond 50 Mtr. below clear water level at the location approved by Client/ Consultant, including
all the necessary labor, PVC casing confirm to IS: 12818, paddle flanges. waste, debris from/due to bore well to be removed
42 & make good upon completion of the works. Work includes but not limited to Gravel packing of suitable size, Mud pit
arrangement.
a) borehole including 6" dia PVC casing 1 Mtr. 830 830 9 9 149.4 979.4
b) borehole including 8" dia PVC casing 1 Mtr. 850 850 9 9 153 1003
Supply and installation of Submerible Pump with motor assembly of Approved Make as per the GSPL Vendor list attached
with this tender (KSB, Lubi,or equivalent make)
a) 1.5 HP 4 Nos. 14000 56000 9 9 10080 66080
b) 3 HP 4 Nos. 15500 62000 9 9 11160 73160
43
c) 5 HP 1 Nos. 25000 25000 9 9 4500 29500
d) 7.5 HP 1 Nos. 40000 40000 9 9 7200 47200
e) 10 HP 1 Nos. 45000 45000 9 9 8100 53100
f) 12 HP 1 Nos. 52000 52000 9 9 9360 61360
44 Supply & replacement of starting capacitor for 1-phase submersible pump set ( 250 mfd) 1 Nos. 400 400 9 9 72 472
Supply & Installation of Bore-well Starter Single-Phase (upto 3Kw)
45 2 Nos. 9000 9 9 1620 10620
Starter should be with in buit over load tripping feature. 4500
Supply & Installation of Bore-well Starter Three-Phase
Starter should be with in buit over load tripping feature.
46
up to 3 Kw 1 Nos. 6000 6000 9 9 1080 7080
4 Kw to 5 Kw 1 Nos. 6500 6500 9 9 1170 7670
Greasing of valves of size mentioned below with high pressure Grease/ pneumatic Sealant Gun under the supervision of
GSPL operator including Supply of manpower, nitrogen cylinder/air compressor, cotton waste for operation of pneumatic
gun. (Grease/Sealant and Grease Gun/pneumatic sealant gun will be supplied by GSPL) No separate charges shall be paid
for Manpower, Tools & Tackles, operation of valve for this activitiy.
6” NB 1 Nos. 800 800 9 9 144 944
8” NB 1 Nos. 800 800 9 9 144 944
47 10” NB 1 Nos. 800 800 9 9 144 944
12” NB 1 Nos. 800 800 9 9 144 944
16” NB 1 Nos. 900 900 9 9 162 1062
18” NB 1 Nos. 970 970 9 9 174.6 1144.6
24” NB 1 Nos. 1120 1120 9 9 201.6 1321.6
30” NB 1 Nos. 1180 1180 9 9 212.4 1392.4
36” NB 1 Nos. 1190 1190 9 9 214.2 1404.2
Operation check of Manual/Gear/ Hydraulic operated Valves/ GOOV by manual opening and closing in presence and as per
instruction of GSPL supervisor - as per size given below (Including Consumables like Grease, Cotton Waste, etc.) No
separate charges shall be paid for Manpower, Tools & Tackles, consumbles used for this activities.
1/2" to 2”NB 1500 Nos. 250 375000 9 9 67500 442500
3”NB 50 Nos. 275 13750 9 9 2475 16225
4”NB 220 Nos. 350 77000 9 9 13860 90860
6” NB 250 Nos. 400 100000 9 9 18000 118000
48 8” NB 250 Nos. 450 112500 9 9 20250 132750
10” NB 50 Nos. 500 25000 9 9 4500 29500
12” NB 120 Nos. 525 63000 9 9 11340 74340
16” NB 2 Nos. 550 1100 9 9 198 1298
18” NB 80 Nos. 575 46000 9 9 8280 54280
24” NB 30 Nos. 600 18000 9 9 3240 21240
30” NB 10 Nos. 600 6000 9 9 1080 7080
36” NB 1 Nos. 750 750 9 9 135 885
Painting of Valves (Ball,Globe & Check) of different sizes with two coats of finished paint of epoxy paint of suitable colour
of approved make as per the GSPL Vendor list attached with this tender to give an even shade after proper scraping of
existing paint by power brushing or suitable method and clearing of surface free from foreign materials as per the
instructions of GSPL EIC.
1/2" to 1”NB 50 Nos. 200 10000 9 9 1800 11800
2”NB 80 Nos. 250 20000 9 9 3600 23600
3”NB 8 Nos. 300 2400 9 9 432 2832
4”NB 15 Nos. 350 5250 9 9 945 6195
49 6” NB 15 Nos. 350 5250 9 9 945 6195
8” NB 10 Nos. 350 3500 9 9 630 4130
10” NB 8 Nos. 500 4000 9 9 720 4720
12” NB 8 Nos. 600 4800 9 9 864 5664
16” NB 1 Nos. 1000 1000 9 9 180 1180
18” NB 4 Nos. 1500 6000 9 9 1080 7080
24” NB 6 Nos. 1500 9000 9 9 1620 10620
30” NB 1 Nos. 1500 1500 9 9 270 1770
36” NB 1 Nos. 1500 1500 9 9 270 1770
Painting of Actuators (excluding SS and Panel Part) installed on different sizes of valves with two coats of finished paint of
epoxy paint of suitable colour of approved make as per the GSPL Vendor list attached with this tender to give an even shade
after proper scraping of existing paint by power brushing or suitable method and clearing of surface free from foreign
50 materials as per the instructions of GSPL EIC.
2”NB to 8"NB 1 Nos. 4000 4000 9 9 720 4720
10” NB to 18"NB 1 Nos. 4500 4500 9 9 810 5310
24” NB to 36"NB 1 Nos. 5000 5000 9 9 900 5900
Supply, Fabrication, Transportation and Installation of lighting Pole with required paint & pole identification tag: material
of GI pipe 4.5 mm thick Make-TATA/Jindal GI pipes and GI reducers of height approximately 5 to 12 Meter as per the
drawing attached including installation of luminaire, JBs, Earthing connection, cable connection etc.on new pole.
51 Type A (DWG-STD-15) 4 Nos. 14500 58000 9 9 10440 68440
Type B(DWG-STD-16) 10 Nos. 25000 250000 9 9 45000 295000
Type C(DWG-STD-25) 1 Nos. 14500 14500 9 9 2610 17110
Type D(DWG-STD-24) 1 Nos. 14500 14500 9 9 2610 17110
Calibration of secondary instruments such as Pressure Transmitter, Diff Pressure Transmitter, Temperature
Transmitter,Pressure Guage, Diff Pressure Gauge, Temperature Gauge, RTD at respective locations. (Trained manpower as
well as master calibrator in the scope of contractor).
PT of Range (0-120kg / cm2) 150 Nos. 900 135000 9 9 24300 159300
TT of Range (-30 to + 55 deg. C) 125 Nos. 900 112500 9 9 20250 132750
52
PG of Range (0-120 bar) 125 Nos. 700 87500 9 9 15750 103250
TG of Range (0-100 degree C) 20 Nos. 250 5000 9 9 900 5900
DPG (0-2 kg/cmM2) 25 Nos. 700 17500 9 9 3150 20650
DPT (0-2 kg/cmM2) 25 Nos. 700 17500 9 9 3150 20650
RTD (PT 100) 180 Nos. 850 153000 9 9 27540 180540
Safety valve calibration of sizes as given below with men, materials tools & tackles, consumables. The job including
dismantling of safety valve from the filter equipment/Pipeline/ Launcher/Receiver/Actuator Valve cylinders at height of
maximum 3 meter, blinding of one upstream side of line flange of removed space of safety valve, Cleaning of all
components by kerosene if required, Lapping of nozzle & disc if required,assembly of valve with repaired component,
Calibration and Testing as found as left set pressure of safety valve at spot with all required materials tools & tackles. seat
tightness required at 90% of test pressure & calibration of PG is required. Re-installation/errection of safety valve on
equipment/Pipeline/ Launcher/Receiver/Actuator Valve cylinders in position after testing/calibration. Consumable such as
53 nitrogen, grease, testing gaskets & painting of Valves etc shall be arranged at site by the contractor for the above job. Gasket
for the pipes / joint flanges shall provided by GSPL. Issuing a certificate of calibration by a competent person. The job shall
be done by the competent person who has certificate possessing by issued Factory Inspector. All type of transportation is
included in the job
For Actutor Valve (Size below1") 175 Nos. 2500 437500 9 9 78750 516250
up to 2" 175 Nos. 3000 525000 9 9 94500 619500
above 2" 10 Nos. 3500 35000 9 9 6300 41300
Supply and mobilization of Nitrogen gas of commercial grade in loose Cylinder / banks of individual cylinder capacity 7m3
at a pressure of 150 kg/Sq cm with all connecting hoses and de-mobilization after completion of job including loading,
54 800 Cu. Mtr. 136000 9 9 24480 160480
unloading, handling Cylinder pressure regulator and pressure gauge with accessories.No separate charges shall be paid for
manpower, tools & tackles, lifting equipments used during this activity. 170
Removal,Refilling & re-installation of pilot Nitrogen Gas cylinder,Water Capacity:6.8 Ltr, Pressure: 150 Kg/Cm2 including
55 transportation to & from site. No separate charges shall be paid for manpower, tools & tackles, lifting equipments used 15 Nos. 10500 9 9 1890 12390
during this activity. 700
Removal, Refilling & Re-installation of pilot Nitrogen Gas cylinder, Water Capacity: 2 Ltr, Filling Pressure: 165 Kg/Cm2
56 @ 15 degree C including transportation. No separate charges shall be paid for manpower, tools & tackles, lifting equipments 1 Nos. 700 9 9 126 826
used during this activity. 700
Removal, Refilling & re-installation of CO2 Gas cylinders used for flooding system of Water Capacity: 68 Ltr, Pressure: 45
Kg/Cm2 including to & fro transportation.
57 50 Nos. 137500 9 9 24750 162250
(CO2 refilling shall be carried out thru PESO approved vendor only). No separate charges shall be paid for manpower,
tools & tackles, lifting equipments used during this activity. 2750
58 Arrangement and supply of water in tanker / truck / lorry only for fire fighting during emergency. 10,000 Litres 1 Nos. 6000 6000 9 9 1080 7080

Monitoring and Maintenance of earthing system as per AMS (Annual Maintenance Schedule) by measuring earth pit
resistance. The job includes cleaning of pit, checking and recording of earthing system circuit resistance by disconnecting
Earth pit from the equipments (provide alternative earthing if needed) and measure the earthing resistance of the
disconnected pit by Winner's three pin method. The earth pit resistance value to be measured under two separate condition
59 viz. (1) isolated from earthing grid and (2) when connected to earthing grid. After measurement it is re-connected and 4000 Per Pit 1200000 9 9 216000 1416000
tightness of all connection to be confirmed. Anti corrosion gel /jelly shall be applied to all earthing connections checked.
Supply & replacement of nut bolts, if required. The work includes adding salt water to the earth pits if required and
replacement of nut bolts. The job shall be carried out by a qualified electrical engineer and endorsed by a competent
authority of respective region and submission of reports

300
Supply & installation of Copper earthing cable 16 sq mm. The job includes the excavation, removal of exisitng Copper
60 Strip, laying of new cable, back-filling & restoration. No separate charges shall be paid for manpower, tools & tackles, 60 R. Mtr. 15600 9 9 2808 18408
equipments, instruments used during this activity. 260
OFC-24 fiber Jointing at pit location by preparation of fiber, removal of the sheath, cleaning of the fiber, fixing the fiber to
the LIU with proper clamping / ties. Numbering of the fiber using ferrules, splicing the fiber to the pigtail, proper routing of
the fiber in the cassette. Proper closure of the cassette, connecting the pigtail to the adapter, and marking the same, for 1-24
fibers joints. Job Include Supply of Jointing Enclosure for 24 core Fiber Cable, Weather proof, as per Standard
Specification and approved make ( Raychem, 3 M make ) and Fault finding & identification using OTDR. End to end
testing of fibres after jointing and submission of report. Incase of unacceptable dB loss at repair joint same needs to be
61 20 Per joint 160000 9 9 28800 188800
rectified with-out any cost implication to GSPL. Final end to end OTDR test shall be carried-out for all 24 Fibres & submit
the report without any cost implication to GSPL. No separate charges shall be paid for manpower,instruments,
transportation used during this activity. Visit for fault finding & final testing shall be considered as one visit only. Complete
Link Testing End to End with Power Source, Laser Source, OTDR meter working with 1310 nm and 1550 nm from both
end including Pigtails, Patch cord for testing. Submission of all 24 core OTDR traces between two terminals or across the
joints. Pit Excavation & back-filling be paid as per relevant SOR.

8000
Illumination Monitoring at various GSPL terminals at Night including required calibrated instrument and transportation
62 160 per Station 400000 9 9 72000 472000
upto the respective sites as per instruction of EIC. Report shall be submitted in GSPL approved format 2500
Environmental Monitoring by carrying out the Ambient air quality measurement for Particulate Matter (P.M10 & PM 2.5),
Oxides of Sulphur (SOx) and Oxides of Nitrogen (NOx) and Noise level measurement at least 7 different spot ( i.e.
7samples) as per GSPL format/EIC Instruction & GPCB norms in each SV station for 24 hrs and analysis of the result for 140 Per Station 770000 9 9 138600 908600
63 submitting to GPCB as per scope of work and instruction by Engineer-in-charge. The scope includes noise level recordiing
for HVS machines also.Noise level monitoring includes DG area during day & night time. 5500
D.G Sets Stack monitoring as per GPCB norms from 45 KVA to 125 KVA 20 Nos. 3500 70000 9 9 12600 82600
64 Potable drinking water analysis as per BIS-10500 (2012) 20 Per Sample 4500 90000 9 9 16200 106200
Collection of hazardous wastes including used engine oil, gear oil, hydraulic oil , turbine oil , compressor oil , transformer
65 oil ,spent oil, filter elements, grease contaminated cotton waste etc. from GSPL stations and disposal-off the same to an 800 Kg 32000 9 9 5760 37760
approved CPCB / GPCB vendor by complying Hazardous Waste (Management and Handling) Rules, 1989. 40
Transportation of diesel in 200 liter capacity of MS barrel from GSPL approved diesel bunk station to GSPL’s Central
storage location and from there or directly from diesel bunk to different SV stations or as directed by engineer-in-charge for
fueling the DG sets. The job includes loading of filled drums in vehicle, transportation abiding all safety precautions and
66 unloading at designated places. Transportation shall maximum of 999 litters at a time.
30-50 KM 1 Per Trip 2000 2000 9 9 360 2360
51-75 KM 1 Per Trip 3000 3000 9 9 540 3540
76-100 KM 1 Per Trip 4500 4500 9 9 810 5310

Supply, installation testing & commissioning of Copper earthing: the job includes:
a) Excavation of a pit of size (900 mm x 900mm x 3500mm deep)
b) placement of Copper earth plate (600mm x600mm x3 6mm) and embedding the GI pipe of 20mm, 3Mtr. length in the
earth
c) back filling the pit with alternate layers of approx 100Kg Charcoal and 50 Kg salt to cover the earth plate
The pit shall further be refilled with earth upto ground level and compacted. Copper Strip (Size 25mm X 3 6mm) 2 nos.
67 20 Nos. 440000 9 9 79200 519200
shall be provided from plate electrode to ground level to facilitate jointing with earth wire. It shall be provided with test link
for testing of the particular earth pit. The funnel shall be installed above the ground for facilitating pouring of water. The
funnel of earthing pits shall be covered by brick masonary chamber (Size 900mm x 900 mm x 600mm) with cement plaster
on inside and outside. The chamber shall be provided with a hinged MS cover and frame fixed on chamber alognwith
tagging on MS plate (400x100mm). The resistance of the pit must be achieved below 1 ohm

22000

Supply, Installation, Testing & Commissinong of GI Pipe Earthing. A Pit (Size : 3500 mm deep) shall be excavated by
auguring or otherwise, 65 dia GI pipe 3.5 Mtr. length shall be put. The GI pipe shall be cut tapered at the bottom and
provided with holes of 12 mm dia. drilled at 75 mm interval upto 2.5 Mtr. length from bottom.The pit shall be back filled
with alternate layers of appx 100 kg of charcoal and 50 kg of salt. The Pit shall further be refilled with earth upto ground
level and compacted. GI Strip size 50x12mm shall be welded to this GI Pipe at ground level to facilitate jointing with earth
68 1 Nos. 22000 9 9 3960 25960
wire. It shall be provided with test link for testing of the particular earth pit. The funnel shall be installed above the ground
for facilitating pouring of water. The funnel of earthing pits shall be covered by brick masonary chamber (Size 900mm x
900mm x 600mm) with cement plaster on inside and outside. The chamber shall be provided with a hinged MS cover and
frame fixed on chamber alongwith tagging on MS plate (400x100mm). The resistance of the pit must be achieved below 1
ohm.
22000
69 Supply, installation testing & commissioning of Copper earthing, Chemical Maintenance Free Earth Pit 30 Nos. 18500 555000 9 9 99900 654900
70 Supply, installation testing & commissioning of GI earthing, Chemical Maintenance Free Earth Pit 50 Nos. 18000 900000 9 9 162000 1062000
Supply, Laying & Installation of Copper earthing strip – 50x 6 mm (Above ground / Under Ground) with over lapping of
minimum 75 mm at joints and two consecutive strip be bolted together with copper bolt., Job includs cutting the strip
71 200 Mtr. 140000 9 9 25200 165200
suitable to site, edge preparation , excavation of required length, strip laying and back filling after completion , site welding
and bending and termaination as per EIC, supply of connection bolts etc. 700
Supply, Laying & Installation of Copper earthing strip – 25 x 3 mm (Above ground / Under Ground) with over lapping of
minimum 75 mm at joints and two consecutive strip be bolted together with copper bolt., Job includs cutting the strip
72 80 Mtr. 48000 9 9 8640 56640
suitable to site, edge preparation , excavation of required length, strip laying and back filling after completion , site welding
and bending and termaination as per EIC, supply of connection bolts etc. 600
Supply, Laying & Installation of GI earthing strip – 50 x 6 mm, (Above ground) with over lapping of minimum 75 mm at
73 joints and two consecutive strips to be welded together and applying bitumin on the joint. Separate charges will not be paid 300 Mtr. 69000 9 9 12420 81420
for manpower, tools & tackles, consumables used for this activity. 230
Supply, Laying & Installation of GI earthing strip – 50 x 6 mm, (Under Ground) with over lapping of minimum 75 mm at
74 joints and two consecutive strips to be welded together and applying bitumin on the joint. Separate charges will not be paid 80 Mtr. 26400 9 9 4752 31152
for excavation, backfilling, manpower, tools & tackles, consumables used for this activity. 330
Supply, Laying & Installation of GI earthing strip – 25 x 3 mm, (Above Ground) with over lapping of minimum 75 mm at
75 joints and two consecutive strips to be welded together and applying bitumin on the joint. Separate charges will not be paid 80 Mtr. 16000 9 9 2880 18880
for excavation, backfilling, manpower, tools & tackles, consumables used for this activity. 200
Supply, Laying & Installation of GI earthing strip – 25 x 3 mm, (Under Ground) with over lapping of minimum 75 mm at
76 joints and two consecutive strips to be welded together and applying bitumin on the joint. Separate charges will not be paid 200 Mtr. 60000 9 9 10800 70800
for excavation, backfilling, manpower, tools & tackles, consumables used for this activity. 300
Replacement of concrete/ MS plate covers of Earth Pits by hinged acrylic covers with locking/bolting facility & with
77 facility to change testing date. The related modifications of massonary works of Earth pits shall be in the scope of the 20 Nos. 39000 9 9 7020 46020
contractor. 1950
78 Supply & replacement of earth pit covers (Precast bid material) 50 Nos. 1950 97500 9 9 17550 115050
79 Tagging of Earth Pit on MS Plate of size (400x100 mm2) 40 Nos. 300 12000 9 9 2160 14160

Supply and Installation of LED tube light having 20W Al body T8 Tube Rod with colour temp. 6500K of
80 20 Nos. 8000 9 9 1440 9440
Bajaj/Philips/CG/Osram/Halonix/Syska/Wipro Make or other makes as per the GSPL Vendor list
400

Supply and Replacement of Lamps (Bajaj/Philips/CG/Osram/GE Make or other makes as as per the GSPL Vendor lsit
attached with this tender) including scaffolding, men, machinery if required as per EIC

Pin/ Thread Type – 70/80w HPSV 20 Nos. 275 5500 9 9 990 6490
70w-HPMV 20 Nos. 275 5500 9 9 990 6490
Pin/ Thread Type – 125w – HPMV 200 Nos. 300 60000 9 9 10800 70800
Pin/Thread Type - 250w - HPMV 20 Nos. 480 9600 9 9 1728 11328
Pin/ Thread Type - 150w - HPSV 100 Nos. 960 96000 9 9 17280 113280
Pin/ Thread Type – 250w – HPSV 200 Nos. 460 92000 9 9 16560 108560
Pin/ Thread Type – 400w – HPSV 20 Nos. 620 12400 9 9 2232 14632
81 36/40w Four Pin CFL 200 Nos. 280 56000 9 9 10080 66080
11 w CFL 100 Nos. 240 24000 9 9 4320 28320
18 w Four/Two Pin CFL 20 Nos. 300 6000 9 9 1080 7080
23 w CFL 20 Nos. 400 8000 9 9 1440 9440
35 w CFL 20 Nos. 540 10800 9 9 1944 12744
70 W CFL 20 Nos. 750 15000 9 9 2700 17700
Tube light 36/40w 600 Nos. 135 81000 9 9 14580 95580
Tube light 18w 100 Nos. 130 13000 9 9 2340 15340
160 W MLL Lamps 20 Nos. 250 5000 9 9 900 5900
150w MHT 50 Nos. 550 27500 9 9 4950 32450
250w MHT 30 Nos. 825 24750 9 9 4455 29205
400w MHT 30 Nos. 1050 31500 9 9 5670 37170
Supply and Replacement of Ballast (Bajaj/Philips/CG/Osram/GE Make or Other makes as per the GSPL Vendor list
attached with this tender) including scaffolding, men, machinery if required as per EIC
70/80w HPSV 30 Nos. 500 15000 9 9 2700 17700
125w – HPMV 130 Nos. 550 71500 9 9 12870 84370
250w - HPMV 30 Nos. 825 24750 9 9 4455 29205
150w – HPSV 100 Nos. 850 85000 9 9 15300 100300
82 250w - HPSV 200 Nos. 1200 240000 9 9 43200 283200
400w – HPSV 15 Nos. 1800 27000 9 9 4860 31860
36/40w VPIT Choke 40 Nos. 275 11000 9 9 1980 12980
9/11 w VPIT Choke 15 Nos. 290 4350 9 9 783 5133
9/11 w Electronic Choke 15 Nos. 290 4350 9 9 783 5133
18 w Electronic Choke 15 Nos. 290 4350 9 9 783 5133
36/40w Electronic Choke 500 Nos. 250 125000 9 9 22500 147500
Supply and Replacement of Lamp Holder at a height up to 12 Mtr. including Collapsible Telescopic ladder & other
arrangements. Test certificate of ladder must be availabe at the point of use.
70/80w HPSV 1 Nos. 140 140 9 9 25.2 165.2
125w – HPMV 20 Nos. 150 3000 9 9 540 3540
250w – HPMV 10 Nos. 180 1800 9 9 324 2124
150w – HPSV 10 Nos. 155 1550 9 9 279 1829
250w – HPSV 10 Nos. 180 1800 9 9 324 2124
400w – HPSV 10 Nos. 240 2400 9 9 432 2832
18w - CFL 10 Nos. 140 1400 9 9 252 1652
36/40w Four Pin CFL 10 Nos. 120 1200 9 9 216 1416
83 Tube light 36/40w 150 Nos. 170 25500 9 9 4590 30090
Long Distance Capacitors 1 Nos. 320 320 9 9 57.6 377.6
Short Distance Capacitors 6 Nos. 180 1080 9 9 194.4 1274.4
Supply & Replacement of LED 36 W 1 Nos. 550 550 9 9 99 649
Supply & replacement of 120 W flood light LED fixture 1 Nos. 8500 8500 9 9 1530 10030
Supply & replacement of 120 W flood light LED 1 Nos. 8500 8500 9 9 1530 10030
Supply & replacement of 72 W street light LED fixture 1 Nos. 5850 5850 9 9 1053 6903
Supply & replacement of 72 W street light LED 1 Nos. 5850 5850 9 9 1053 6903
Supply & replacement of 45 W flameproof street light LED fixture 1 Nos. 7000 7000 9 9 1260 8260
Supply & replacement of 45 W flameproof street light LED 1 Nos. 7000 7000 9 9 1260 8260
Supply & replacement of 30 W, 12V light LED for Solar light 1 Nos. 8000 8000 9 9 1440 9440
Supply, Erection and Installation of Halogen lamp along with fixtures (Bajaj/Philips/CG/Osram/GE Make or Other makes
as per the GSPL Vendor list attached with this tender)
84
150 W 1 Nos. 2000 2000 9 9 360 2360
500 W 1 Nos. 2500 2500 9 9 450 2950
Supply and Installation of HPSV Integral flood light fixture of Approved Make as per the GSPL Vendor list attached with
this tender made of pressure die-cast aluminium housing in powder coated black finish. Heat resistant toughened glass fixed
to housing by stainless steel toggles. Pre-anodised asymmetric hammered finish aluminium reflector along with side
85 reflectors. Control gear housing wired with ballast, lamp and accessories etc. confirming to IP 65 alongwith M.S cradle for
facilitating ease of mounting.
150W 6 Nos. 5000 30000 9 9 5400 35400
250W 15 Nos. 5250 78750 9 9 14175 92925
86 Supply and insallation of 2 X18 W Optic lighting fixure surface mounted including electronic choke and lamp 1 Nos. 2500 2500 9 9 450 2950
87 Supply and installation of 2 X 36W FTL industrial type fixture including electronic choke and lamp 1 Nos. 1950 1950 9 9 351 2301
Supply and Installation of 12V, up to 30W LED Fixture for Solar Light of Approved Make as per the GSPL, Cofirming to
88 1 Nos. 18000 9 9 3240 21240
IP65. 18000
Supply and Installation of LED Street light 60 W of Bajaj/Philips/CG/Osram/Halonix/Syska/Wipro Make or other makes as
89 1 Nos. 7500 9 9 1350 8850
per the GSPL Vendor list having IP66 or more 7500
90 Supply and installation of 50 W/100 W LED Streetlight luminaire Approved Make as per the GSPL Vender List 1 Nos. 9800 9800 9 9 1764 11564
Supply and Installation of LED Flood light 120 W of Bajaj/Philips/CG/Osram/Halonix/Syska/Wipro Make or other makes
91 1 Nos. 12500 9 9 2250 14750
as per the GSPL Vendor list having IP66 or more 12500
92 Supply and installation of 150 W/200 W LED Floodlight luminaire Approved Make as per the GSPL Vender List 1 Nos. 17500 17500 9 9 3150 20650
Supply and Installation of LED Flameproof light 40 W of Bajaj/Philips/CG/Osram/Halonix/Syska/Wipro Make or other
93 1 Nos. 8500 9 9 1530 10030
makes as per the GSPL Vendor list having IP66 or more 8500
Supply, erection and Installation of LED, Integral Flameproof Well Glass Lighting Fixture of Approved Make as per the
94 1 Nos. 7500 9 9 1350 8850
GSPL Vendor list 7500
Supply, erection and Installation of 125 W HPMV, Integral Flameproof Well Glass Lighting Fixture of Approved Make as
per the GSPL Vendor list attached with this tender, made of cast aluminium alloy LM6, with in built control gear box with
95 1 Nos. 2550 9 9 459 3009
bulb, ballast completed with all accessories Flameproof to gas group IIA & IIB and Weather proof to IP 65, with 2 nos. of
cable entry of 3/4" ET. 2550
Supply and Installation of single/twin 36/40w tube light fixture Approved Make as per the GSPL Vendor list attached with
this tender having FRP (Fiber glass reinforced polyester) housing with rubber gasket and clear acrylic cover with stainless
96 steel toggles. The fixture should have stove enemeled white CRCA gear tray cum reflector, electronic choke, 36/40w TL 20 Nos. 39500 9 9 7110 46610
complete with all accessories. It should be suitable for direct mounting or suspension.
1975

Supply & Installation of functional widespread luminaires for recessed mounting in modular strip ceilings suitable for 2 x
36w TL fluorescent lamps/ LED lights. Housing shuold be made of CRCA sheet steel, powder coated white, accomodating
all electrical accessories pre-wire up to a terminal block. Designed for mounting into modular strip ceilings. The optical
97 5 Nos. 9250 9 9 1665 10915
system should be fixed on the luminaire by four spring clips and be suspendable during re-lamping / maintenance. The
optical system should have high efficiency mirror optics of standard aluminium with faceted side reflectors and diffuse
white lamellae. The fixture shall be supplied with electronic choke, 2 x 36w TL complete with all accesories.
1850
Supply and Installation of LED Type Indication Lamp in Panel.
Red Colour , 230 V AC 10 Nos. 200 2000 9 9 360 2360
Yellow Colour , 230 V AC 10 Nos. 200 2000 9 9 360 2360
Blue Colour , 230 V AC 10 Nos. 200 2000 9 9 360 2360
98
Green Colour , 230 V AC 10 Nos. 200 2000 9 9 360 2360
Red Colour , 12 V DC 10 Nos. 200 2000 9 9 360 2360
Red Colour , 24 V DC 10 Nos. 200 2000 9 9 360 2360
Green Colour , 24 V DC 10 Nos. 200 2000 9 9 360 2360
Supply & Instalaltion of L&T or euqivalent Make SFU (4 pole) with Top & Bottom Fabricated Enclosure for Cable Entry of
FN-Series.
99
FN-150 5 Nos. 13000 65000 9 9 11700 76700
FN-200 5 Nos. 16500 82500 9 9 14850 97350
Suppy and replacement of Capacitors
(Bajaj/Philips/CG/Osram/GE Make or other makes as per the GSPL Vendor list attached with this tender)
1 mfd 1 Nos. 80 80 9 9 14.4 94.4
1.5 mfd 1 Nos. 80 80 9 9 14.4 94.4
2 mfd 1 Nos. 90 90 9 9 16.2 106.2
4 mfd 20 Nos. 110 2200 9 9 396 2596
100
10 mfd 30 Nos. 130 3900 9 9 702 4602
15 mfd 15 Nos. 150 2250 9 9 405 2655
33 mfd 150 Nos. 200 30000 9 9 5400 35400
42 mfd 5 Nos. 260 1300 9 9 234 1534
120-150 mfd 1 Nos. 340 340 9 9 61.2 401.2
250 mfd 1 Nos. 400 400 9 9 72 472
Supply & Replacement of MCB, 10 KA of Aproved Make as per the GSPL Vendor list attached with this tender
6A SP, DP, TP, TPN, FP 8 Nos. 1250 10000 9 9 1800 11800
10A SP, DP, TP, TPN, FP 40 Nos. 1300 52000 9 9 9360 61360
16A SP, DP, TP, TPN, FP 10 Nos. 1400 14000 9 9 2520 16520
101 25A SP, DP, TP, TPN, FP 10 Nos. 1450 14500 9 9 2610 17110
32A SP, DP, TP, TPN, FP 10 Nos. 1600 16000 9 9 2880 18880
40A SP, DP, TP, TPN, FP 1 Nos. 1650 1650 9 9 297 1947
63A SP, DP, TP, TPN, FP 1 Nos. 1900 1900 9 9 342 2242
100A SP, DP, TP, TPN, FP 1 Nos. 5900 5900 9 9 1062 6962
Supply & Replacement of MCCB, 50 KA of Aproved Make as per the GSPL Vendor list attached with this tender
32 A TP, FP 1 Nos. 14000 14000 9 9 2520 16520
63 A TP, FP 1 Nos. 14500 14500 9 9 2610 17110
100 A TP, FP 1 Nos. 15000 15000 9 9 2700 17700
102
102
125 A TP, FP 1 Nos. 17500 17500 9 9 3150 20650
150 A FP 1 Nos. 19000 19000 9 9 3420 22420
200 A FP 1 Nos. 20000 20000 9 9 3600 23600
250 A TP, FP 1 Nos. 22000 22000 9 9 3960 25960
Supply & Replacement of ELCB/RCCB of Aproved Make as per the GSPL Vendor list attached with this tender
Upto 25 A DP 1 Nos. 2400 2400 9 9 432 2832
103
Upto 63 A DP, FP 30mA 1 Nos. 3000 3000 9 9 540 3540
Upto 63 A DP, FP 100mA 1 Nos. 3700 3700 9 9 666 4366
Supply and Replacement of HRC Fuse of Aproved Make as per the GSPL Vendor list attached with this tender
Upto 16 A 130 Nos. 200 26000 9 9 4680 30680
25 A 1 Nos. 240 240 9 9 43.2 283.2
104 32 A 1 Nos. 250 250 9 9 45 295
63 A 6 Nos. 320 1920 9 9 345.6 2265.6
100 A 4 Nos. 430 1720 9 9 309.6 2029.6
200 A 4 Nos. 670 2680 9 9 482.4 3162.4
Supply and Replacement of Backalite Fuse Fittings of Aproved Make for below given size
105 20 Amps 10 Nos. 280 2800 9 9 504 3304
30 Amps 10 Nos. 280 2800 9 9 504 3304
Supply and Installation of utility spares of Aproved Make as per the GSPL Vendor list attached with this tender
3 Pin Plug Top upto 16A 6 Nos. 110 660 9 9 118.8 778.8
3 Pin Socket (With/Without Safety Shutter) upto 16A 15 Nos. 250 3750 9 9 675 4425
Piano switch upto 16 A (single pole) (Industrial/Decorative) 30 Nos. 220 6600 9 9 1188 7788
Piano switch upto 32 A (double pole) (Industrial/Decorative) 6 Nos. 410 2460 9 9 442.8 2902.8
3 Pin Switch Socket board upto 16 A with indicator (PVC/ Acrylic/Metal) 8 Nos. 400 3200 9 9 576 3776
3 Pin 6/16 A surface type combined switch socket outlet (Industrial/Decorative) 12 Nos. 400 4800 9 9 864 5664
106 3 Pin 6/16 A flush type socket outlet 1 Nos. 280 280 9 9 50.4 330.4
Switch type fan regulator Electronic 6 Nos. 280 1680 9 9 302.4 1982.4
Socket type fan regulator Electronic 1 Nos. 350 350 9 9 63 413
25 mm dia PVC conduit 4 Mtr. 70 280 9 9 50.4 330.4
PVC Casing / Capping of size upto 50 x 16 mm 6 Mtr. 70 420 9 9 75.6 495.6
PVC Flexbile Corrugated Conduit upto size 50 mm 1 Mtr. 80 80 9 9 14.4 94.4
Starter for Tubelight 36/40w 20 Nos. 35 700 9 9 126 826
Ignitor 70/150/250/400 w supporting upto 30 Mtr.s. 400 Nos. 270 108000 9 9 19440 127440
107 Supply and Installation FLUSH Type On-Off Push Button switch 19mm Dia 1 Nos. 200 200 9 9 36 236
108 Supply and Installation NO Block for On-Off Push Button Flush Type 1 Nos. 120 120 9 9 21.6 141.6
109 Supply and Installation NC Block for On-Off Push Button Flush Type 1 Nos. 150 150 9 9 27 177
110 Supply and Installation STOP Push Button Switch 19mm Dia 1 Nos. 180 180 9 9 32.4 212.4
Supply and Installation of DIN Rail Mounted, Power (Bus-Bar) Terminals Type CBT suitable for cables with Ring / Fork
type lugs in Melamine Housing alongwith partition plates and end plates. The current bar should be tapped and the fixing
111 bolt should have slotted head, that allows use of screw-driver for bolting for below mentiond conductor size.
35 sq. mm. to 70 sq. mm. 1 Nos. 600 600 9 9 108 708
95 sq. mm. to 120 sq. mm. 1 Nos. 800 800 9 9 144 944
Supply and Installation of DIN Rail Mounted, Screw or Nut Driver Operated, Stud Type Terminals, TYPE CBT in
Melamine Housing with end plates for below mentioned conductor size.
112
6 sq. mm. to 16 sq. mm. 1 Nos. 240 240 9 9 43.2 283.2
25 sq. mm. to 35 sq. mm. 1 Nos. 450 450 9 9 81 531
Supply and Installation of DIN Rail Mounted Feed ThroughTerminals Type CST in Melamine Housing with end plates for
below mentioned conductor size.
113 2.5 sq. mm. to 6 sq. mm. 1 Nos. 350 350 9 9 63 413
10 sq. mm. to 25 sq. mm. 1 Nos. 450 450 9 9 81 531
35 sq. mm to 70 sq. mm. 1 Nos. 550 550 9 9 99 649
Supply and Installation of MS Junction Box of of Aproved Make as per the GSPL Vendor list attached with this tender –
114 1 Nos. 540 9 9 97.2 637.2
Size 6x4 inch 540
Supply and Installation of Four Way Flameproof Junction box of Aproved Make as per the GSPL Vendor list attached with
115 15 Nos. 28500 9 9 5130 33630
this tender – 125 mm 1900
Supply and Installation of PVC Junction Box of Aproved Make as per the GSPL Vendor list attached with this tender– Size
116 8 Nos. 7200 9 9 1296 8496
200 x 150 mm 900
Supply and Installation Side Hinged SMC FRP Based Pole mounted Junction Box for Street Light/Flood Lighting pole for
below mentioned size of Approved make like SINTEX.
117
Size 250 mm X 200 mm X 105mm 20 Nos. 1400 28000 9 9 5040 33040
Size 300 mm X 200 mm X 105 mm 30 Nos. 1700 51000 9 9 9180 60180
Supply and Installation of Terminal Connectors in Electrical Panels & Junction bos suitable to Din Rail type mounting for
below mentioned size of Approved make with Side lolk plates/seprators Operating voltage is 440 Volts.
118 up to 16 SQmm 50 Nos. 100 5000 9 9 900 5900
Above 16 SQmm up to-32 Sqmm 10 Nos. 125 1250 9 9 225 1475
Above 32 SQm m up to-63 Sqmm 10 Nos. 180 1800 9 9 324 2124
Supply and Installation of Junction Box of Aproved Make as per the GSPL Vendor list attached with this tender made of 14
119 SWG MS Sheet, of size 250mm x 200mm x 125 mm, having canopy, pole mounting bracket, hinged door with lock, two 1 Nos. 900 9 9 162 1062
earth studs, 19 dia conduit welded with box for cable outlet to pole, and 4 way terminal block. 900
Supply and Installation of Bolt on/Din-Rail Industrial type Fabricated Finished Enclosure (MCB Distribution Box)of
Aproved Make Legrand, Hawells
120
4P MCB 4-Way Bolt on Type/Din Rail Type 8 Nos. 500 4000 9 9 720 4720
4P MCB 8-Way Bolt on Type/Din Rail Type 5 Nos. 700 3500 9 9 630 4130
Supply and Replacement of Acrylic Cover for Gate light doom & fixture of 70 - 80W-- HPSV.
121 1 Nos. 1250 9 9 225 1475
(Bajaj/Philips/CG/Osram/GE Make or Other makes as per the GSPL Vendor list attached with this tender) 1250
122 Supply and Installation of Glass Cover for 125w/250w HPMV flameproof fixture 1 Nos. 1850 1850 9 9 333 2183
Supply and Installation of Post Top Lanterns of Aproved Make as per the GSPL Vendor list attached with this tender for
123 8 Nos. 23600 9 9 4248 27848
Gate Lighting with IP 54 Protection, Complete with lamp and gear box and all accessories, CG Make 2950
Supply and Replacement of Pressure Regulator (Make:GSPL approved vendor, Gas: N2, inlet: 150 Kg/cm2 & outlet: 4-
124 1 Nos. 5600 9 9 1008 6608
10Kg/CM2) 5600
Supply & Installation of OPTICAL-PHOTOELECTRIC SMOKE DETECTOR of of Aproved Make as per the GSPL
125 1 Nos. 3100 9 9 558 3658
Vendor list attached with this tender 3100
Supply and Installation of SS 316, double compression type Cable Glands for armoured twin and multicore power cables of
voltage grade 650/1100 V and Instrument cables alongwith PVC Shrouds. The Glands Shall be Flameproof to Gas Group
IIA, IIB and / or Weatherproof to IP 65, for cables having overall diameters as given below.
126 19 mm 80 Nos. 190 15200 9 9 2736 17936
25 mm 40 Nos. 270 10800 9 9 1944 12744
40 mm 1 Nos. 750 750 9 9 135 885
80 mm 1 Nos. 2100 2100 9 9 378 2478
Sealing of Junction box,cable gland, Electrical & Instrumentation cable rising PVC/GI Pipe, Electrical & Instrumentations
127 Cable Entry/Exit holes Electrical & Instrumentation box by PUF seal (1K-S) make:Stanvac including supply of the 100 Nos. 23000 9 9 4140 27140
Material 230
Maintenance of Junction box including Cleaning, supply & replacement of Rubber Seal,Nut-Bolt , Entry Plug, Gland &
128 Washer. No separate charges shall be paid for manpower, Rubber seal, Nut-Bolt, entry plug, Gland, washer, consumables, 200 Nos. 27000 9 9 4860 31860
tools & tackles used during execution of this activity. 135
Cable Fault Repairing - Supply and installation of M-Seal Cable Jointing Kits for following Cables including IR test and
Re-commissioning of cable. The work includes excavation upto the cable, making required trenches for execution of job
and backfilling the area. No separate charges shall be paid for manpower, excavation, backfilling, consumables,
129 equipments, tools & tackles used during execution of this activity.
Upto 3 C x 25 sq. mm. Cu. Armoured Cable 1 Nos. 2400 2400 9 9 432 2832
Upto 4 C x 25 sq. mm. Cu. Armoured Cable 1 Nos. 2700 2700 9 9 486 3186
Supply and Installation of Cable Jointing Kit for Following Cable (3M/Raychem Make) including IR test and Re-
commissioning of cable.The work includes excavation upto the cable, making required trenches for execution of job and
backfilling the area. No separate charges shall be paid for manpower, excavation, backfilling, consumables, equipments,
tools & tackles used during execution of this activity.
Upto 3.5 C x 50 sq. mm. Al. Armoured Cable 1 Nos. 2250 2250 9 9 405 2655
130
Upto 4 C x 50 sq. mm. Al. Armoured Cable 1 Nos. 2350 2350 9 9 423 2773
3.5 C x 70 sq. mm. Al. Armoured Cable 1 Nos. 2500 2500 9 9 450 2950
3.5 C x 95 sq. mm. Al. Armoured Cable 1 Nos. 2600 2600 9 9 468 3068
3.5 C x 300 sq. mm. Al. Armoured Cable 1 Nos. 4350 4350 9 9 783 5133
3.5 C x 120 sq. mm. Al. Armoured Cable 1 Nos. 2700 2700 9 9 486 3186

Supply, Laying
& Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts of
following sizes Above-Ground on cable trays, supported on steel structures, in ready made trenches. The rates shall include
the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars, lugs, ferrules, double compression type
SS glands, etc, including transportation with all labor and materials as per the specifications, drawings and directions of
Engineer-in-charge . The Insulation Resistance of cable has to be checked & report to be submitted before commissioning.
No separate charges shall be paid for manpower,consumables, tools & tackles used during execution of this activity.

Upto 2 C x 6 sq. mm. Cu. Armoured Cable 1 Mtr. 330 330 9 9 59.4 389.4
Upto 3 C x 6 sq. mm. Cu. Armoured Cable 250 Mtr. 300 75000 9 9 13500 88500
Upto 4 C x 6 sq. mm. Cu. Armoured Cable 80 Mtr. 350 28000 9 9 5040 33040
131 3 C x 10 sq. mm. Cu. Armoured Cable 40 Mtr. 455 18200 9 9 3276 21476
4 C x 10 sq. mm. Cu. Armoured Cable 1 Mtr. 610 610 9 9 109.8 719.8
3 C x 16 sq. mm. Cu. Armoured Cable 1 Mtr. 610 610 9 9 109.8 719.8
4 C x 16 sq. mm. Cu. Armoured Cable 10 Mtr. 750 7500 9 9 1350 8850
3 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr. 1200 1200 9 9 216 1416
4 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr. 1300 1300 9 9 234 1534
1 C x 25 sq. mm. Cu. Armoured Cable 10 Mtr. 350 3500 9 9 630 4130
Upto 3.5 C x 50 sq. mm. Al. Armoured Cable 1 Mtr. 360 360 9 9 64.8 424.8
Upto 4 C x 50 sq. mm. Al. Armoured Cable 30 Mtr. 390 11700 9 9 2106 13806
3.5 C x 70 sq. mm. Al. Armoured Cable 1 Mtr. 460 460 9 9 82.8 542.8
3.5 C x 95 sq. mm. Al. Armoured Cable 1 Mtr. 550 550 9 9 99 649
3.5 C x 120 sq. mm. Al. Armoured Cable 1 Mtr. 680 680 9 9 122.4 802.4

Laying &
Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts of
following sizes Above-Ground on cable trays, supported on steel structures, in ready made trenches. The rates shall include
the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars, lugs, ferrules, double compression type
SS glands, etc, . Only Cable will be supplied by GSPL at designated stores.The Insulation Resistance of cable has to be
checked & report to be submitted before commissioning.No separate charges shall be paid for transportation of cables from
GSPL designated stores to the site, manpower, consumables, equipments, tools & tackles used during execution of this
activity.
132
Upto 2 C x 6 sq. mm. Cu. Armoured Cable 1 Mtr. 170 170 9 9 30.6 200.6
Upto 4 C x 25 sq. mm. Cu. Armoured Cable 40 Mtr. 175 7000 9 9 1260 8260
Upto 3.5 C x 50 sq. mm. Al. Armoured Cable 40 Mtr. 185 7400 9 9 1332 8732
Upto 4 C x 50 sq. mm. Al. Armoured Cable 1 Mtr. 320 320 9 9 57.6 377.6
3.5 C x 70 sq. mm. Al. Armoured Cable 1 Mtr. 340 340 9 9 61.2 401.2
3.5 C x 95 sq. mm. Al. Armoured Cable 1 Mtr. 350 350 9 9 63 413
3.5 C x 300 sq. mm. Al. Armoured Cable 1 Mtr. 400 400 9 9 72 472
3.5 C x 120 sq. mm. Al. Armoured Cable 1 Mtr. 370 370 9 9 66.6 436.6
Supply, Laying & Termination of PVC insulated, FRLS Outer sheathed, PVC Inner Sheathed instrumentation Cable
Voltage grade 650 / 1100 Volts of following sizes Above-Ground on cable trays, supported on steel structures, in ready
made trenches. The rates shall include the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars,
lugs, ferrules, double compression type SS glands, etc, including transportation with all labor and materials as per the
specifications, drawings and directions of Engineer-in-charge . No separate charges shall be paid for
manpower,consumables, tools & tackles used during execution of this activity.
133
Instrument cable upto 2P x 1.5sqmm armoured cable 100 Mtr. 135 13500 9 9 2430 15930
Instrument cable upto 6P x 1.5sqmm armoured cable 8 Mtr. 340 2720 9 9 489.6 3209.6
Instrument cable upto 12P x 1.5sqmm armoured cable 1 Mtr. 460 460 9 9 82.8 542.8
Flexible cable upto 1 C x 6 sq. mm. cable 150 Mtr. 120 18000 9 9 3240 21240
Flexible cable upto 3 C x 6 sq. mm. cable 1 Mtr. 210 210 9 9 37.8 247.8
Non-FRLS Flexible Earthing cable of size upto 25 sq. mm. 250 Mtr. 225 56250 9 9 10125 66375
Laying & Termination of PVC insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts
of following sizes Above-Ground on cable trays, supported on steel structures, in ready made trenches. The rates shall
include the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars, lugs, ferrules, double
compression type SS glands, etc, Cable will be supplied by GSPL at designated stores. No separate charges shall be paid for
transportation of cables from GSPL designated stores to the site, manpower, consumables, equipments, tools & tackles used
during execution of this activity
134
Instrument cable upto 2P x 1.5sqmm armoured cable 100 Mtr. 110 11000 9 9 1980 12980
Instrument cable upto 6P x 1.5sqmm armoured cable 15 Mtr. 120 1800 9 9 324 2124
Instrument cable upto 12P x 1.5sqmm armoured cable 25 Mtr. 150 3750 9 9 675 4425
Flexible cable upto 1 C x 6 sq. mm. cable 1 Mtr. 60 60 9 9 10.8 70.8
Flexible cable upto 3 C x 6 sq. mm. cable 40 Mtr. 80 3200 9 9 576 3776
Non-FRLS Flexible Earthing cable of size upto 25 sq. mm. 15 Mtr. 100 1500 9 9 270 1770

Supply, Laying & Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 /
1100 Volts of following sizes Under-Ground and / or pull through pipes including excavation and backfilling etc. Work
includes excavation of trench of average 0.5 meter wide & up to 1.2 meter depth with all appropriate tools & tacles( manual
work inside terminals). Layer of sand shall be of 100 mm thick & brick layer shall be laid on cable for protection and back
filling of trench after completion of work. work includes carting of surplus earth/debris and handling/unrolling of cable,
supply of auminium tags, lugs, ferrules, double compression type SS glands, etc, including transportation with all labor and
materials as per the specifications, drawings and directions of Engineer-in-charge . The Insulation Resistance of cable has to
be checked & reported before commissioning.No separate charges shall be paid for excavation, backfilling, manpower,
consumables, equipments, tools & tackles used during execution of this activity

Upto 3 C x 6 sq. mm. Cu. Armoured Cable 500 Mtr. 300 150000 9 9 27000 177000
Upto 4 C x 6 sq. mm. Cu. Armoured Cable 100 Mtr. 350 35000 9 9 6300 41300
3 C x 10 sq. mm. Cu. Armoured Cable 1 Mtr. 500 500 9 9 90 590
135
4 C x 10 sq. mm. Cu. Armoured Cable 50 Mtr. 600 30000 9 9 5400 35400
3 C x 16 sq. mm. Cu. Armoured Cable 1 Mtr. 700 700 9 9 126 826
4 C x 16 sq. mm. Cu. Armoured Cable 25 Mtr. 900 22500 9 9 4050 26550
3 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr. 1000 1000 9 9 180 1180
4 C x 25 sq. mm. Cu. Armoured Cable 25 Mtr. 1100 27500 9 9 4950 32450
1 C x 25 sq. mm. Cu. Armoured Cable 80 Mtr. 320 25600 9 9 4608 30208
Upto 3.5 C x 50 sq. mm. Al. Armoured Cable 1 Mtr. 380 380 9 9 68.4 448.4
Upto 4 C x 50 sq. mm. Al. Armoured Cable 30 Mtr. 400 12000 9 9 2160 14160
3.5 C x 70 sq. mm. Al. Armoured Cable 1 Mtr. 800 800 9 9 144 944
3.5 C x 95 sq. mm. Al. Armoured Cable 1 Mtr. 860 860 9 9 154.8 1014.8
3.5 C x 120 sq. mm. Al. Armoured Cable 1 Mtr. 960 960 9 9 172.8 1132.8
2 core x 1.5 mm2 Armoured Shield Data cable 1 Mtr. 375 375 9 9 67.5 442.5

Laying & Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts
of following sizes Under-Ground and / or pull through pipes including excavation and backfilling etc. Work includes
excavation of trench of average 0.5 meter wide & up to 1.2 meter depth with all appropriate tools & tacles( manual work
inside terminals). Layer of sand shall be of 100 mm thick & brick layer shall be laid on cable for protection and back filling
of trench after completion of work. work includes carting of surplus earth/debris and handling/unrolling of cable, supply of
auminium tags, lugs, ferrules, double compression type SS glands, etc, Cable will be supplied by GSPL at designated
store.The Insulation Resistance of cable has to be checked & reported before commissioning.No separate charges shall be
paid for transportation of cable from GSPL designated store to site, excavation, backfilling, manpower, consumables,
equipments, tools & tackles used during execution of this activity.

Upto 3 C x 2.5 sq. mm. Cu. Armoured Cable 130 Mtr. 175 22750 9 9 4095 26845
Upto 3 C x 6.0 sq. mm. Cu. Armoured Cable 1 Mtr. 350 350 9 9 63 413
136
Upto 3 C x 10.0 sq. mm. Cu. Armoured Cable 1 Mtr. 550 550 9 9 99 649
Upto 3 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr. 550 550 9 9 99 649
Upto 4 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr. 700 700 9 9 126 826
Upto 3.5 C x 50 sq. mm. Al. Armoured Cable 1 Mtr. 800 800 9 9 144 944
Upto 4 C x 50 sq. mm. Al. Armoured Cable 6 Mtr. 900 5400 9 9 972 6372
3.5 C x 70 sq. mm. Al. Armoured Cable 1 Mtr. 950 950 9 9 171 1121
3.5 C x 95 sq. mm. Al. Armoured Cable 1 Mtr. 1000 1000 9 9 180 1180
3.5 C x 300 sq. mm. Al. Armoured Cable 1 Mtr. 1100 1100 9 9 198 1298
3.5 C x 120 sq. mm. Al. Armoured Cable 1 Mtr. 1000 1000 9 9 180 1180
3 C x 1 Sq mm Armoured Power Cable 1 Mtr. 220 220 9 9 39.6 259.6
2 core x 1.5 mm2 Armoured Shield Data cable 1 Mtr. 240 240 9 9 43.2 283.2

Supply & Instalaltion of GI Cable Trays with cover on MS steel sUpport. All Accessories shall be in the scope of
contractor like MS angle sUpport , channel,Fastners, Clamp,Cable tie etc. as per below mentiond size

Perforated Cable tray with cover 450 mm 35 per Mtr. 2800 98000 9 9 17640 115640
Perforated Cable tray with cover 300 mm 35 per Mtr. 2100 73500 9 9 13230 86730
137
Perforated Cable tray with cover 150 mm 35 per Mtr. 1100 38500 9 9 6930 45430
Perforated Cable tray with cover 100 mm 35 per Mtr. 850 29750 9 9 5355 35105
Ladder type Cable tray 450 mm 35 per Mtr. 2300 80500 9 9 14490 94990
Ladder type Cable tray 300 mm 35 per Mtr. 1700 59500 9 9 10710 70210
Ladder type Cable tray 150 mm 35 per Mtr. 900 31500 9 9 5670 37170

Supply, Laying & Termination of PVC insulated, FRLS Outer sheathed, PVC Inner Sheathed Instrumentation Cable
Voltage grade 650 / 1100 Volts of following sizes Under-Ground and / or pull through pipes including excavation and
backfilling etc. Work includes excavation of trench of average 0.5 meter wide & up to 1.2 meter depth with all appropriate
tools & tacles( manual work inside terminals). Layer of sand shall be of 100 mm thick & brick layer shall be laid on cable
for protection and back filling of trench after completion of work. work includes carting of surplus earth/debris and
handling/unrolling of cable, supply of auminium tags, lugs, ferrules, double compression type SS glands, etc, including
138 transportation with all labor and materials as per the specifications, drawings and directions of Engineer-in-charge . The
insulation resistance of cable has to be checked & reported before commissioning.No separate charges shall be paid for
excavation, backfilling, manpower, consumables, equipments, tools & tackles used during execution of this activity

Instrument cable upto 1P x 1.5sqmm armoured cable 1 Mtr. 180 180 9 9 32.4 212.4
Instrument cable upto 2P x 1.5sqmm armoured cable 300 Mtr. 200 60000 9 9 10800 70800
Instrument cable upto 6P x 1.5sqmm armoured cable 1 Mtr. 550 550 9 9 99 649
Instrument cable upto 12P x 1.5sqmm armoured cable 1 Mtr. 850 850 9 9 153 1003

Laying & Termination of PVC insulated, FRLS Outer sheathed, PVC Inner Sheathed Instrumentation Cable Voltage grade
650 / 1100 Volts of following sizes Under-Ground and / or pull through pipes including excavation and backfilling etc.
Work includes excavation of trench of average 0.5 meter wide & up to 1.2 meter depth with all appropriate tools &
tacles( manual work inside terminals). Layer of sand shall be of 100 mm thick & brick layer shall be laid on cable for
protection and back filling of trench after completion of work. work includes carting of surplus earth/debris and
handling/unrolling of cable, supply of auminium tags, lugs, ferrules, double compression type SS glands, etc, Cable will be
139 supplied by GSPL at designated store.The Insulation Resistance of cable has to be checked & reported before
commissioning.No separate charges shall be paid for transportation of cable from GSPL designated store to site, excavation,
backfilling, manpower, consumables, equipments, tools & tackles used during execution of this activity.

Instrument cable upto 1P x 1.5sqmm armoured cable 30 Mtr. 150 4500 9 9 810 5310
Instrument cable upto 2P x 1.5sqmm armoured cable 80 Mtr. 160 12800 9 9 2304 15104
Instrument cable upto 6P x 1.5sqmm armoured cable 25 Mtr. 170 4250 9 9 765 5015
Instrument cable upto 12P x 1.5sqmm armoured cable 6 Mtr. 180 1080 9 9 194.4 1274.4
Supply laying and Termination (using Conduit,Rojet Box ,temrinal block, crimping, connectors) of telecom cables
Underground/Aboveground. Cable will be supplied by GSPL at designated store.The Insulation Resistance of cable has to
be checked & reported before commissioning.No separate charges shall be paid for excavation, backfilling, manpower,
consumables, equipments, tools & tackles used during execution of this activity.
140
Polythene (Solid/Foam Skin) Insulated Jelly Filled Cables (5 Pair ) 1 Mtr. 325 325 9 9 58.5 383.5
Polythene (Solid/Foam Skin) Insulated Jelly Filled Cables (10 Pair ) 1 Mtr. 425 425 9 9 76.5 501.5
Flexible 2 pair Telephone cable 25 Mtr. 70 1750 9 9 315 2065
RG-11 Video Cable 1 Mtr. 90 90 9 9 16.2 106.2

Supply & Installation of Heavy Duty Exhaust Fan, that is totally enclosed, highly efficient heavy duty motor with pressure
die cast aluminium rotor mounted on two ball bearings. Aerodynamically contoured blades and Rigid frame with rubber
mountings for silent operation. Suitable for continuous running. It should be Epoxy powder coated with specially pre-
treated components for better resistance to corrosion and acid alkali fumes. It should be supplied alongwith self opening
louvers for tota protection against birds and direct rain. The Fan should confirm to IS 2312 standards.Cable will be supplied
141 by GSPL at designated store.The Insulation Resistance of cable has to be checked & reported before commissioning.No
separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this
activity.

Size : 300 mm, Single Phase, 1400 rpm 1 Nos. 5000 5000 9 9 900 5900
Size : 450mm, Single Phase, 1400 rpm 6 Nos. 6300 37800 9 9 6804 44604
Size : 600mm, Single Phase, 950 rpm 1 Nos. 7500 7500 9 9 1350 8850
Supply & Instalation of Heavy Duty Exhaust Fan, made of cast aluminium alloy LM6, Exproof to gas group IIA & IIB.
Suitable for continuos running. It should be Epoxy powder coated for resistance to corrosion and acid alkali fumes. It
should be supplied with self opening louvers for total protection against birds and direct rain. No separate charges shall be
142 paid for manpower, consumables,equipments, tools & tackles used during execution of this activity.
Size : 300 mm, Single Phase 1 Nos. 6500 6500 9 9 1170 7670
Size : 450mm, Single Phase 1 Nos. 7800 7800 9 9 1404 9204
Supply and Installation of ceiling fan(GSPL approved vendor make), white / ivory colour, 230v, 1-Phase, 1200 mm sweep.
It shall have robust two piece motor construction, All Aluminum alloy construction with double ball bearing and powder
143 25 Nos. 55000 9 9 9900 64900
coated finish to protect metal from corrosion.The fan shall be energy efficient having 5 star rating. No separate charges shall
be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 2200
144 Supply and Installation of Wall mounted cabin fan, 230V, 1-Phase, 300 mm sweep. 1 Nos. 2200 2200 9 9 396 2596
Supply and Installation of selfpriming Monoblock pumps operating on single phase, upto rating of 1.5 HP, with matching
piping connections. Work includes dismantling of alraedy installed pump, required inlet/outlet connection, foot valves
145 6 Nos. 34800 9 9 6264 41064
servicing & cable termination. No separate charges shall be paid for manpower, consumables,equipments, tools & tackles
used during execution of this activity. 5800
Rewinding of the following motors/Monoblock Pump. work includes removal of the equipment, rewinding & repairing, re-
installation of the same.(Including replacement of Bearing).No separate charges shall be paid for manpower,
consumables,equipments, bearings, tools & tackles used during execution of this activity.
Ceiling fan 30 Nos. 550 16500 9 9 2970 19470
146 Monoblock pump of 0.5 HP 4 Nos. 2500 10000 9 9 1800 11800
Monoblock pump of 0.75 HP 4 Nos. 3000 12000 9 9 2160 14160
Monoblock pump of 1.0 HP 4 Nos. 3000 12000 9 9 2160 14160
Exhaust Fan heavy duty 20 Nos. 1100 22000 9 9 3960 25960
Exhaust Fan heavy duty explosion proof IIA & IIB 2 Nos. 1500 3000 9 9 540 3540
Supply & Installation of G.I Pipe for electrical related works. No separate charges shall be paid for excavation, backfilling,
manpower, consumables, equipments, tools & tackles used during execution of this activity.
1" 12 Mtr. 250 3000 9 9 540 3540
147
2" 2 Mtr. 450 900 9 9 162 1062
3" 10 Mtr. 500 5000 9 9 900 5900
4" 5 Mtr. 980 4900 9 9 882 5782
Supply and Installation of G.I Bend Pipe ( for Cable entry). No separate charges shall be paid for excavation, backfilling,
manpower, consumables, equipments, tools & tackles used during execution of this activity.
1" 1 Nos. 120 120 9 9 21.6 141.6
148
2" 1 Nos. 180 180 9 9 32.4 212.4
3" 1 Nos. 250 250 9 9 45 295
4" 1 Nos. 300 300 9 9 54 354
Supply, Fabrication and Installation of Aluminium Canopy for Field Instruments, Open Path Gas Detectors, Flow
149 1 Kg 1000 9 9 180 1180
Computers. Dimensions of the canopy as per field instrument actual at site and instruction as per EIC 1000
Supply, Fabrication and Installation of G.I Sheet Canopy for Field Instruments, Open Path Gas Detectors, Flow Computers.
150 40 Kg 9600 9 9 1728 11328
Dimensions of the canopy as per field instrument actual at site and instruction as per EIC 240
Supply and Installation of "U" Clamps of CS material of standard type with NPT at bolting end including polyethelyne
insulation/conduit for "U" Clamps including nuts and washers for different size of pipe clamps as per instruction of EIC. No
separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this
activity.
1/2" 6 Nos. 70 420 9 9 75.6 495.6
1" 20 Nos. 80 1600 9 9 288 1888
151 2" 220 Nos. 90 19800 9 9 3564 23364
3" 20 Nos. 130 2600 9 9 468 3068
4" 25 Nos. 150 3750 9 9 675 4425
6" 12 Nos. 200 2400 9 9 432 2832
8" 10 Nos. 210 2100 9 9 378 2478
10' 1 Nos. 290 290 9 9 52.2 342.2
12" 1 Nos. 340 340 9 9 61.2 401.2
Supply and Installation of "U" Clamps of SS material of standard type with NPT at bolting end including polyethelyne
insulation/conduit for "U" Clamps including nuts and washers for different size of pipe clamps as per instruction of EIC. No
separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this
activity.
152 1/4" 15 Nos. 290 4350 9 9 783 5133
1/2" 6 Nos. 300 1800 9 9 324 2124
3/8" 100 Nos. 390 39000 9 9 7020 46020
3/4" 1 Nos. 500 500 9 9 90 590
1" 1 Nos. 600 600 9 9 108 708
Supply & installation of MS sheet, removal of existing sheet, if any. Powder coated, Color:Simense gray or Smoke gray or
GI Sheet along with all accessories like studs & washers. No separate charges shall be paid for manpower, consumables,
equipments, tools & tackles used during execution of this activity.
153 MS sheet 18 gauge 10 Sq. Mtr. 500 5000 9 9 900 5900
MS sheet 22 gauge 1 Sq. Mtr. 690 690 9 9 124.2 814.2
GI sheet 18 gauge 1 Sq. Mtr. 690 690 9 9 124.2 814.2
GI sheet 22 gauge 1 Sq. Mtr. 690 690 9 9 124.2 814.2
Supply & installation of SS sheet Cabinet (Removal of old SS Sheet Cabinet from Actuator Valve/Equipment, if
any)conforming to IP65 for Actuator Valve/Any Equipment along with all provisions for cable entry, glands, accessories
like studs & washers
154 SS sheet 18 gauge Upto 12"Valve 1 Nos. 10500 10500 9 9 1890 12390
SS sheet 18 gauge Above 12"Valve 1 Nos. 11000 11000 9 9 1980 12980
SS sheet 22 gauge upto 12"Valve 1 Nos. 9500 9500 9 9 1710 11210
SS sheet 22 gauge above 12"Valve 4 Nos. 10000 40000 9 9 7200 47200
Supply and placing of insulation Rubber Mats( 2 mm thick, class-A, Colour-Blue) as per IS15652;2006(New IS Standard)
155 & of approved make of GSPL Vendor list attached with the tender. Material batch test certificate shall be provided along 1 Sq. Mtr. 1890 9 9 340.2 2230.2
with material. 1890
Supply and placing of insulation Rubber Mats( 2.5 mm thick, class-B, Colour-Blue) as per IS15652;2006(New IS Standard)
156 & of approved make of GSPL Vendor list attached with the tender. Material batch test certificate shall be provided along 1 Sq. Mtr. 2200 9 9 396 2596
with material. 2200
Painting of lighting pole/ Solar pole / OPD Pole/chimeny/ Stack including surface preperation, supply of paint and
application of 2 coat of high build chlorinated rubber / zinc phosphate primer and two coats of finished paint of epoxy paint
of Silver colour approved make as per the GSPL Vendor list attached with this tender to give an even shade after proper
removal of existing paint by power brushing or suitable method and clearing of surface free from foreign materials. No
separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this
activity.
157
157
Upto 4.5 Meter Height Pole (FLP Light pole in process area) 35 Nos. 1800 63000 9 9 11340 74340
Upto 6 Meter Height Pole (Solar Light) 20 Nos. 2000 40000 9 9 7200 47200
6.1 Meter to 9 Meter Height Pole 20 Nos. 2500 50000 9 9 9000 59000
9.1 Meter to 11 Meter Height Pole 15 Nos. 3000 45000 9 9 8100 53100
11.1 Meter to 15 Meter Height Pole 4 Nos. 4500 18000 9 9 3240 21240
Servicing of Air-Conditioners (includes cleaning of blower condenser fan, cleaning of air filter with vacuum cleaner,
Evaporator coil, condenser coil and equipment,metallic/plastic body parts with soaked cotton cloths, Condenser ,Oil the
motor as and when required, Checking of Voltage stabilizers / Timers and remote control units to maintain these in healthy
158 conditions,Cleaning of Outdoor unit by Blower, Checking of working of compressor (Ampere of Compressor),Pressure 1500 Nos. 750000 9 9 135000 885000
checking of refrigerant,Checking the working of Stabilizer unit,Checking of working of Capacitors of outdoor
unit,Checking of drain pipe of outdoor unit, Checking the working of Flapper motor)
500
Supply and installation of capacitor for A.C compressor of 1.5 TR, 2 TR and 4TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
159 1.5 TR 17 Nos. 400 6800 9 9 1224 8024
2 TR 55 Nos. 450 24750 9 9 4455 29205
4 TR 3 Nos. 500 1500 9 9 270 1770
Supply and installation of capacitor for fan motor of 1.5 TR, 2 TR and 4TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
160 1.5 TR 2 Nos. 150 300 9 9 54 354
2 TR 10 Nos. 180 1800 9 9 324 2124
4 TR 1 Nos. 200 200 9 9 36 236
Supply and installation of thermostat switch of compressor for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
161 1 Nos. 500 9 9 90 590
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General 500
Supply and repalcing of faulty relay in compressor for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
162 1 Nos. 200 9 9 36 236
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General 200
Supply and repalcing of 3 way switch for 1.5 TR, 2 TR and 4TR AC as per OEM supply of
163 LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
1.5 TR, 2TR, 4 TR 1 Nos. 250 250 9 9 45 295
Supply and repalcing of outer cover for AC units for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
164 1.5 TR 1 Nos. 3000 3000 9 9 540 3540
2 TR 1 Nos. 3500 3500 9 9 630 4130
4 TR 1 Nos. 4000 4000 9 9 720 4720
Supply and repalcing of front grill of Split A.Cof 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
165 1.5 TR 1 Nos. 3000 3000 9 9 540 3540
2 TR 1 Nos. 3500 3500 9 9 630 4130
4 TR 1 Nos. 4000 4000 9 9 720 4720
Supply and installation of copper tubing for1.5 TR, 2 TR and 4 TR AC as per OEM supply of
166 LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
1.5 TR, 2TR, 4 TR 60 Mtr. 850 51000 9 9 9180 60180
Supply and repalcing of contactor coil for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
167 1.5 TR 4 Nos. 1500 6000 9 9 1080 7080
2 TR 25 Nos. 1800 45000 9 9 8100 53100
4 TR 1 Nos. 2500 2500 9 9 450 2950
168 Reapairing of control curcuit of indoor AC unit up to 04 Ton 1 Nos. 3500 3500 9 9 630 4130
169 Supply and installation of control curcuit unit from OEM of indoor AC unit up to 04 Ton 1 Nos. 10500 10500 9 9 1890 12390
Supply and installation of required Cu armoured cable for AC having capacity mentioned below:
170
1.5 TR, 2TR, 4 TR 80 Mtr. 300 24000 9 9 4320 28320
Supply and repalcing of Drain pipe of PVC for 1.5 TR, 2 TR, 2.5 TR, 5.5 TR and 8.5 TR AC
171
1.5 TR, 2TR, 4 TR 12 Mtr. 30 360 9 9 64.8 424.8
Supply and repalcing of Swing motor 12 V for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
172 1.5 TR 1 Nos. 750 750 9 9 135 885
2 TR 1 Nos. 850 850 9 9 153 1003
4 TR 1 Nos. 1000 1000 9 9 180 1180
Supply and repalcing of exhaust fan of outdoor unit for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
173 1.5 TR 3 Nos. 850 2550 9 9 459 3009
2 TR 8 Nos. 950 7600 9 9 1368 8968
4 TR 1 Nos. 1000 1000 9 9 180 1180
Supply and repalcing of flapper for indoor unit for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
174 1.5 TR 1 Nos. 700 700 9 9 126 826
2 TR 1 Nos. 850 850 9 9 153 1003
4 TR 1 Nos. 1000 1000 9 9 180 1180
Supply and repalcing of Air filter net for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
175 1.5 TR 1 Nos. 700 700 9 9 126 826
2 TR 1 Nos. 800 800 9 9 144 944
4 TR 1 Nos. 950 950 9 9 171 1121
Supply and repalcing of insulation of AC duct from outdoor to indoor for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
176 80 Mtr. 20000 9 9 3600 23600
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General 250
Repairing,rewinding & re-installation of blower fan motor for 1.5 TR, 2 TR and 4 TR AC.This job includes removal of
faulty motor, repairing & rewinding and re-installation. No separate charges shall be paid for manpower, consumables,
bearings, equipments, tools & tackles used during execution of this activity.
177
1.5 TR 2 Nos. 1200 2400 9 9 432 2832
2 TR 6 Nos. 1300 7800 9 9 1404 9204
4 TR 1 Nos. 1400 1400 9 9 252 1652
Charging of refrigarant for 1.5 TR, 2 TR and 4 TR AC
1.5 TR 9 Nos. 2800 25200 9 9 4536 29736
178
2 TR 70 Nos. 3000 210000 9 9 37800 247800
4 TR 1 Nos. 4200 4200 9 9 756 4956
Supply & Replacemet of condensor coil for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
179 1.5 TR 10 Nos. 11000 110000 9 9 19800 129800
2 TR 12 Nos. 11500 138000 9 9 24840 162840
4 TR 1 Nos. 14250 14250 9 9 2565 16815
Supply and repalcing of fan blade assembly of 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
180 1.5 TR 4 Nos. 750 3000 9 9 540 3540
2 TR 10 Nos. 850 8500 9 9 1530 10030
4 TR 1 Nos. 950 950 9 9 171 1121
Supply and replacement of motor assembly of indoor unit for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
181 1.5 TR 4 Nos. 2600 10400 9 9 1872 12272
2 TR 15 Nos. 3000 45000 9 9 8100 53100
4 TR 1 Nos. 3400 3400 9 9 612 4012
Shifting of A.C including gas charging, upto three meter copper tubing and civil work for 1.5 TR, 2 TR and 4 TR AC. The
job includes dismantling,handling, transportation, re-installation, testing & commissioning of A.C.Units. No separate
charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. Above
182 three meter copper tubing will be paid extra as per relevant SOR.
1.5 TR 6 Nos. 3200 19200 9 9 3456 22656
2 TR 18 Nos. 4000 72000 9 9 12960 84960
4 TR 1 Nos. 5000 5000 9 9 900 5900
183 Reparing of stabilizer Upto 4 KVA 230 volt of Vinner , GRE, AB tronics make 4 Nos. 1000 4000 9 9 720 4720
184 Reparing of stabilizer of from 5 KVA to 8 KVA 230 volt of Vinner , GRE, AB tronics make 1 Nos. 2500 2500 9 9 450 2950
Supply and installation of the outdoor unit condensor body of AC of LG/Carrier, voltas , Blue-star/ONIDA/Hitachi/Diakin/
Mitshubishi/ O'General. The job includes dismantling of old one,re-installation of new one , testing & commissioning. No
separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this
185 activity.
1.5 TR 4 Nos. 4750 19000 9 9 3420 22420
2 TR 10 Nos. 5500 55000 9 9 9900 64900
4 TR 1 Nos. 7500 7500 9 9 1350 8850
Supply & installation of stabilizer Upto 4 KVA 230 volt of Vinner , GRE, AB tronics make,
186 1 Nos. 19000 9 9 3420 22420
It should be cu wound with overload tripping feature, voltmeter(digital) and MCB of GSPL approved vendor. 19000
Supply & installation of stabilizer from 5 KVA to 8 KVA 230 volt of Vinner , GRE, AB tronics make,
187 1 Nos. 23000 9 9 4140 27140
It should be cu wound with overload tripping feature, voltmeter(digital) and MCB of GSPL approved vendor. 23000
Supply of compressor having warranty of atleast one year for compressor and installation including gas charging for 1.5 & 2
188 TR Split AC as per OEM supply of LG/Carrier/ONIDA/Hitachi/Voltas. No separate charges shall be paid for manpower, 15 Nos. 146250 9 9 26325 172575
consumables, equipments, tools & tackles used during execution of this activity. 9750
Supply of compressor having warranty of atleast one year for compressor and installation including gas charging for 3-
Phase Split AC as per OEM supply of LG/Carrier/ONIDA/Voltas/Hitachi. No separate charges shall be paid for manpower,
189 consumables, equipments, tools & tackles used during execution of this activity.
4 TR 1 Nos. 12000 12000 9 9 2160 14160
Supply of compressor having warranty of atleast one year for compressor and installation including gas charging for 1.5
190 1 Nos. 17500 9 9 3150 20650
Window AC as per OEM supply of LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar 17500
191 Reparing & Reinstalaltion of AC Timer Panel, including replacement of Timer PCB & Relays. 1 Nos. 2400 2400 9 9 432 2832
192 Supply & installation of AC Timer Panel of Microprocessor based for Max 6 no of A.C Timer Operation. 1 Nos. 3750 3750 9 9 675 4425
Supply & Installation of Faulty PCB of Indoor AC unit for 1.5 TR to 2.0 TR as per OEM supply of LG/Carrier/Onida
193 25 Nos. 46875 9 9 8437.5 55312.5
/Hitachi/VoltasMake/Bluestar/Diakin/ Mitshubishi/ O'General 1875
Supply & Instalaltion of Air Conditioner out door unit Bracket/Stand. The Job includes of installtion of required bracket in
194 12 Nos. 7200 9 9 1296 8496
wall with drill & suitable fastners. 600
Servicing of DG Sets as per rating mentioned below ( includes physical inspection, checking for damaged parts, repairing of
damaged parts, oil checking, trial run, synchronize checking, full load RPM checking, Voltage checking and adjustment,
Lube oil Checking, battery checking etc. with men, tools and tackles as required). Cost of spare parts replaced shall be paid
195 as per relevant SOR. No separate charges shall be paid for manpower, consumables, equipments, tools & tackles used
during execution of this activity.
upto 50 KVA 170 Nos. 3300 561000 9 9 100980 661980
51 to 125 KVA 20 Nos. 3800 76000 9 9 13680 89680
196 Supply and installation of Banjo hose for DG set up to 50 KVA 1 Nos. 670 670 9 9 120.6 790.6
197 Supply and Installation of KWH meters in DG set 1 Nos. 1800 1800 9 9 324 2124
198 Supply and installation of Thermostat for DG set up to 50 KVA 1 Nos. 1200 1200 9 9 216 1416
199 Supply and installation of Water temperature switch for DG set up to 50 KVA 1 Nos. 800 800 9 9 144 944
200 Supply and installation of Spin on Lube oil Filter for DG set up to 50 KVA 1 Nos. 500 500 9 9 90 590
201 Supply and installation of Spin on Diesel Filter for DG set up to 50 KVA 1 Nos. 500 500 9 9 90 590
202 Supply and installation of Battery Charger 12 V for DG set up to 50 KVA 1 Nos. 3500 3500 9 9 630 4130
203 Supply and installation of Magnetic Pick-up coil for DG set up to 50 KVA 1 Nos. 5000 5000 9 9 900 5900
204 Supply of Coolant for coolant cooled engines of Cummins/Kirloskar Make 1 Litres 100 100 9 9 18 118
205 Supply and Installation of DG Set Exhaust pipe Insulation (Rope) Coating 40 R. Mtr. 2500 100000 9 9 18000 118000
Repairing of the leaked Radiator of Diesel Generator Set for the Capacity from 51 to 125 KVA includes dismantling and
206 1 Nos. 3500 9 9 630 4130
installation. 3500
Repairing of the leaked Radiator of Diesel Generator Set for the Capacity Upto 50 KVA includes dismantling and
207 1 Nos. 3500 9 9 630 4130
installation. 3500
Supply & replacement of Automatic Voltage Regulator of crompton greaves /AVR-SR 7/3/SX-440 AVR of Cummins make
208 D.G set. No separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution 1 Nos. 12000 9 9 2160 14160
of this activity. 12000
209 Supply and Installation of Fuel Filter PRE Type of Kirloskar/Cummins/ Crompton Greaves Make 70 Nos. 600 42000 9 9 7560 49560
210 Supply of Fuel Filter MIC Type of Kirloskar/Cummins/ Crompton Greaves make 70 Nos. 600 42000 9 9 7560 49560
211 Supply of Lube Oil Filter Element of Kirloskar/Cummins/ Crompton Greaves Make 70 Nos. 800 56000 9 9 10080 66080
212 Supply of Air Filter of Kirloskar/Cummins/ Crompton Greaves Make 20 Nos. 1300 26000 9 9 4680 30680
213 Supply of Air Cleaner of Kirloskar/Cummins/ Crompton Greaves Make 20 Litres 1100 22000 9 9 3960 25960
Supply & replacement of "V"-Belt for blower of Kirloskar/Cummins/ Crompton Greaves/ A49 make. No separate charges
214 2 Nos. 1200 9 9 216 1416
shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 600
Supply of & replacement "V"-Belt for dynamo of Kirloskar/Cummins/ Crompton Greaves /A45 make. No separate charges
215 9 Nos. 5400 9 9 972 6372
shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 600
Supply & replacement of Bearing set of Kirloskar/Cummins/ Crompton Greaves make. No separate charges shall be paid
216 4 Nos. 3600 9 9 648 4248
for manpower, consumables, equipments, tools & tackles used during execution of this activity. 900
Supply & replacement of Oil seal for crank of Kirloskar/Cummins/ Crompton Greaves make. No separate charges shall be
217 1 Nos. 1250 9 9 225 1475
paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 1250
Supply & replacement of Steel Braided Diesel Pipe with/without banjo connection of Kirloskar make. No separate charges
218 40 Mtr. 20000 9 9 3600 23600
shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 500
219 Supply and replacement of engine oil of Kirloskar make / (20W40/15W40) 600 Litres 380 228000 9 9 41040 269040
Supply & replacement of Copper Washer set of Kirloskar/Cummins/ Crompton Greaves make. No separate charges shall
220 1 Nos. 700 9 9 126 826
be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 700
Supply & replacement of "O" ring set of Kirloskar/Cummins/ Crompton Greaves make. No separate charges shall be paid
221 1 Nos. 890 9 9 160.2 1050.2
for manpower, consumables, equipments, tools & tackles used during execution of this activity. 890
Supply & Installation of Automatic Float-Boost charger of NHP Make Provided by M/s Kirloskar/Cummins/ Crompton
222 Greaves of 12V 6 Amp Rating. No separate charges shall be paid for manpower, consumables, equipments, tools & tackles 1 Nos. 4500 9 9 810 5310
used during execution of this activity. 4500
Supply, removal of old battery & Installation of new 12V Lead-Acid Battery of Approved make for Invertor/ DG Set. No
separate charges shall be paid for manpower, consumables, equipments, tools & tackles, used during execution of this
activity. Contractor shall buyback the old battery.
150 Ah 20 Nos. 12000 240000 9 9 43200 283200
223
180 Ah 10 Nos. 13000 130000 9 9 23400 153400
97Ah 1 Nos. 11000 11000 9 9 1980 12980
135 Ah 1 Nos. 12500 12500 9 9 2250 14750
166 Ah 1 Nos. 14500 14500 9 9 2610 17110
Supply & Installation of 12V SMF Battery of Approved make. No separate charges shall be paid for manpower,
consumables, equipments, tools & tackles used during execution of this activity. Contractor shall buyback the old battery.
42 Ah 5 Nos. 10700 53500 9 9 9630 63130
224
65 Ah 1 Nos. 13500 13500 9 9 2430 15930
150 Ah 1 Nos. 22700 22700 9 9 4086 26786
180 Ah 1 Nos. 28890 28890 9 9 5200.2 34090.2

Servicing of Alternator of below mentioned rating DG sets, the job includes removal of oil and dirt accumulation, greasy
deposits on the windings should be wiped off with a lint free cloth dipped in petroleum solvent such as kerosene, petroleum
spirit to avoid short circuit. To check the condition of magnetic rotors & bearings, no-load and full-load test etc. No separate
225 charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity.

upto 50 KVA 1 Nos. 4200 4200 9 9 756 4956


51 to 125 KVA 1 Nos. 5000 5000 9 9 900 5900
Servicing of DG starter system. The Work involves checking of ignition start switch & magnetic switch, fuse between
ignition switch and 12 V battery, 12 V battery voltage and Sp. Gravity of battery water. Top-up of DM water in battery if
required.
226 Supply and replacement of bearings. 1 Nos. 1800 1800 9 9 324 2124
Supply and replacement of magnetic rotors. 1 Nos. 3500 3500 9 9 630 4130
Rewinding of Alternator upto 50 kVA . 1 Nos. 16000 16000 9 9 2880 18880
Rewinding of Alternator above 50 kv to 125 KVA 1 Nos. 25000 25000 9 9 4500 29500
Servicing of below mentioned electrical panel: The job shall include cleaning of the panel from outside and inside by
vaccum cleaner & Manual, checking of operation of MCCB/ACB/MCB, Indication Lamp, Meters
(KWh/Voltmeters/Ammeters/PF meters/FrequncyMeters etc.), Contactor, Fuses, CTs, Spacers etc. and sealing of the open
cable entries by PVC/GI blind plug . The job shall also include Identification, termination & proper Dressing of Cable. All
227 required tools, tackles, manpower and PVC/GI blind plug shall be in contractor's scope. The report submission in GSPL
approved format is also part of the job. The job shall be carried out by qualified electrician.
Only MEDB 75 Nos. 6000 450000 9 9 81000 531000
Other Panel except MEDB 150 Nos. 3500 525000 9 9 94500 619500
228 Supply and installation of Power contactors (65A-150A; UI=1000V). 1 Nos. 12500 12500 9 9 2250 14750
229 Supply & Replacement of Faulty Power Contactor coil (65A-150 A;UI=1000V) 1 Nos. 300 300 9 9 54 354
230 Supply & Replacement of Faulty Aux Contactor coil (For R,Y,B Phase Indication Contactor, 240 V Rating) 15 Nos. 600 9000 9 9 1620 10620
231 Supply & Replacement of Faulty Aux Contactor (For R,Y,B Phase Indication, 4A, 415/440 V Rating) 25 Nos. 850 21250 9 9 3825 25075
Supply and replacement of Current Transformer 1
CT Rasin Cast : CT ratio 100/1A, CL 5P20, VA 7.5 1 Nos. 3950 3950 9 9 711 4661
CT Rasin Cast : CT ratio 100/1A, CL 1, VA 7.5 1 Nos. 1050 1050 9 9 189 1239
CT Rasin Cast : CT ratio 75/1A, CL 5P20, VA 15 1 Nos. 4500 4500 9 9 810 5310
CT Rasin Cast : CT ratio 75/1A, CL 1, VA 10 1 Nos. 1050 1050 9 9 189 1239
232 CT Rasin Cast : CT ratio 75/1A, CL 5P20, VA 7.5 1 Nos. 3950 3950 9 9 711 4661
CT Rasin Cast : CT ratio 75/1A, CL 1, VA 5 1 Nos. 980 980 9 9 176.4 1156.4
CT Resin Cast : CT ratio 50/1A, CL 1, VA 5 1 Nos. 980 980 9 9 176.4 1156.4
CT Tape Wound : CT ratio 50/1A, CL 5P20, VA 5 1 Nos. 2950 2950 9 9 531 3481
CT Tape Wound : CT ratio 50/1A, CL 5P20, VA 15 1 Nos. 2950 2950 9 9 531 3481
CT Tape Wound : CT ratio 50/1A, CL 1, VA 5 1 Nos. 750 750 9 9 135 885
Supply and replacement of Potential Transformer
233
PT ratio 415/110V, 50VA 1 Nos. 1200 1200 9 9 216 1416
Supply and replacement of Analog/Digital Ammeters
CTR 75/1A Range 0-75A, Size 96 x 96 sq. mm. 1 Nos. 1500 1500 9 9 270 1770
CTR 100/1A Range 0-100A, Size 96 x 96 sq. mm. 1 Nos. 1500 1500 9 9 270 1770
234 CTR 50/1A, Range 0-50A, Size 96 x 96 sq. mm. 1 Nos. 1500 1500 9 9 270 1770
CTR 50/1A, Range 0-50A, Size 72 x 72 sq. mm. 1 Nos. 1500 1500 9 9 270 1770
DC 0-20A, 72 x 72 sq.mm 1 Nos. 1350 1350 9 9 243 1593
DC 0-20 A, Size 96 x 96 sq. mm. 1 Nos. 1500 1500 9 9 270 1770
Supply and replacement of Analog/Digital Voltmeters
AC 0-500 Volts, Size 96 x 96 sq. mm. 4 Nos. 1500 6000 9 9 1080 7080
AC 0-500 Volts, Size 72 x 72 sq. mm. 1 Nos. 1350 1350 9 9 243 1593
235
DC 0-30 Volts, Size 96 x 96 sq. mm. 1 Nos. 1500 1500 9 9 270 1770
DC 0-500 Volts, Size 96 x 96 sq. mm. 1 Nos. 1500 1500 9 9 270 1770
DC 0-30 Volts, Size 72 x 72 sq. mm. 1 Nos. 1350 1350 9 9 243 1593
Maintenance of cable trench and cable trays which involves cleaning by Vaccum Cleaner & manual, cable dressing, cable
236 identification etc.No separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during 1500 R. Mtr. 150000 9 9 27000 177000
execution of this activity. 100
Measurement of Insulation Resistance of Main-feeder cable (above 3C/4C X 25 sq.mm. ) during Plant shutdown time with
all required tools, tackles and skilled manpower
237 1 Per Cable 145 9 9 26.1 171.1
The job includes disconnection of termination at both ends & reconnection after completion of job.No separate charges shall
be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 145
Measurement of Insulation Resistance of cables below 3C/4C X 25 sq. mm.
238 The job includes disconnection of termination at both ends & reconnection after completion of job. No separate charges 1 Per Cable 220 9 9 39.6 259.6
shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 220
Preventive maintenance of switchgears 415 V, 250 A (involves cleaning of circuit breaker contacts and testing of relays). No
separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this 1 Nos. 1200 9 9 216 1416
239 activity. 1200
Supply and top-up of breaker oil in case of MOCB. 1 Nos. 1300 1300 9 9 234 1534
Supply and replacement of SF6 cylinder in case of SF6 breaker. 1 Nos. 1550 1550 9 9 279 1829
Servicing and repair of 1250 VA inverter units for emergency lighting system. The works involves cleaning, to check the
condition of converter-rectifier units, DC capacitors, Batteries etc. of make "Keprej, Microtek, Sukam". No separate charges 1 Nos. 4500 9 9 810 5310
shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 4500
240
Supply and installation of inverter upto 1600 VA of make Microtek/ Sukam/ Luminous 1 Nos. 40000 40000 9 9 7200 47200
Supply and Replacement of Converter-Rectifier unit. 4 Nos. 1200 4800 9 9 864 5664
Supply and replacement of DC capacitor. 1 Nos. 850 850 9 9 153 1003
Dismantling, powdercoating (Alkali Resistant Epoxy Powder Coated , Shade:RAL 7032) & reassembling of Ni-CD Battery
Rack. Work includes Surface Cleaning of batteries with DM water & potential measurement of each cell voltage after
241 15 Nos. 82500 9 9 14850 97350
reassembling. No separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during
execution of this activity. 5500
Ni-CD Battery Bank maintenance including cleaning of battery by removing each cells from battery racks, dust/ corrosion
removal from terminals & battery cells, Specific Gravity Checking, Water level checking & refilling of DM water (if
required), application of petrolium jelly on each battery terminal & links as per instruction of Engineer In charge. All
242 55000 Per Battery 1430000 9 9 257400 1687400
required tools tackles like hydrometer, insulated spanners, etc., PPEs, DM water & other consumable are in the scope of
contractor . No separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during
execution of this activity. 26

Stenciling & Painting of numbers/ letters/ logos/ arrow etc including supply of fluorescent/ highlighted paint/ acrylic
243 emulsion/ oil paint of approved brand as per the approved vendor list given in tender and quality wherever required as per 250 Sq. Mtr. 287500 9 9 51750 339250
directed by GSPL E-I-C: Area of the Stenciling & Painting shall be calculated on the basis of length & width of words.
1150
Supply and filling of bentonite slurry in pipe conduits. The Job includes excavation upto the underground vent pipe, opening
of vent pipe if required, sealing of vent pipe after bentonite filling, backfilling, provision of all required manpower,
244 machinery, bentonite, water and power etc., for complete job and as per instruction of EIC. No separate charges shall be 6 Cu. Mtr. 30000 9 9 5400 35400
paid for excavation, backfilling, cutting & welding of vent pipe, manpower, consumables, equipments, tools & tackles used
during execution of this activity. 5000
Load testing of EOT/Mono Rails of various capacities in presence of competent authority including supply of dead weight
block of required capacity and submission of certificates. The job includes examination and testing of lifting tools and
tackles as per Factories Act,1948 and providing certificate in FORM No:10 (Prescribed under rule 60) by competent person
who has certificate possessing by issued Factory Inspector . Tested date, safe working load, due date etc shall be written on
the equipment at end of testing as per instruction of Engineer In-Charge. No separate charges shall be paid for manpower,
245 consumables,lifting equipments, transportation of test load, tools & tackles used during execution of this activity.

up to 2 Tonne 1 Nos. 4500 4500 9 9 810 5310


up to 5 Tonne 3 Nos. 8000 24000 9 9 4320 28320
up to 10 Tonne 1 Nos. 11000 11000 9 9 1980 12980
up to 15 Tonne 1 Nos. 15000 15000 9 9 2700 17700

Hydro testing of Launcher/Receiver, Filters as per GSPL Requirements( Test Pressure- 150 Barg, Holding period - Min 4
Hours). Test includes Complete hydrostatic test arrangement i.e. test facilities with high pressure hose pipe, Calibrated
digital pressure gauge, pressure recorder & chart, suitable manifold and any special requirement to conduct the hydrostatic
test at site location and submission of reports. Required Valve operation, blinding if required, removal of filter elements, re-
installation of filter elements after completion of Hydro- test. No separate charges shall be paid for manpower,
consumables,lifting equipments,water, tools & tackles used during execution of this activity. The job includes examination
and testing of pressure vessel as per Factories Act 1948 and providing certificate in FORM No:11 (Prescribed under rule 61)
by competent person who has certificate possessing by issued Factory Inspector . Tested date, Test Pressure, due date etc
246 shall be written on the equipment at end of testing as per instruction of Engineer In-Charge.

Launcher/ Receiver Barrel size upto - 18" dia 1 Nos. 8900 8900 9 9 1602 10502
Launcher/ Receiver barrel size from 20" to - 36" dia 1 Nos. 15000 15000 9 9 2700 17700
Launcher/ Receiver barrel size 40" dia 1 Nos. 20000 20000 9 9 3600 23600
upto 12" dia size Filter 1 Nos. 14500 14500 9 9 2610 17110
14" to 20" dia size Filter 1 Nos. 17500 17500 9 9 3150 20650
24" to 30" dia size Filter 1 Nos. 20500 20500 9 9 3690 24190
36" to 60" dia size Filter 1 Nos. 20500 20500 9 9 3690 24190
247 Visual inspection & Certfications of filter as per factory act through approved competent person. 1 Nos. 6500 6500 9 9 1170 7670
Pneumatic testing of Launcher/Receiver, Filters as per GSPL Requirements Test Pressure shall be 1.1 times of design
pressure (MAOP), holding period- Min 30 minutes. Test includes Complete Pneumatic test arrangement i.e. test facilities
with high pressure hose pipe, Calibrated digital pressure gauge, suitable manifold and any special requirement to conduct
the Pneumatic test at site location and submission of reports. Required Valve operation, blinding if required, removal of
filter elements, re-installation of filter elements after completion of Pneumatic Test. No separate charges shall be paid for
manpower, consumables,lifting equipments,Nitrogen, tools & tackles used during execution of this activity. Positive
isolation of connected piping system to the equipments to be tested, if required.
248
Launcher/ Receiver Barrel size upto - 18" dia 1 Nos. 22000 22000 9 9 3960 25960
Launcher/ Receiver barrel size from 20" to - 36" dia 1 Nos. 30000 30000 9 9 5400 35400
Launcher/ Receiver barrel size 40" dia 1 Nos. 35000 35000 9 9 6300 41300
upto 12" dia size Filter 2 Nos. 22000 44000 9 9 7920 51920
14" to 20" dia size Filter 2 Nos. 30000 60000 9 9 10800 70800
24" to 30" dia size Filter 1 Nos. 40000 40000 9 9 7200 47200
36" to 60" dia size Filter 1 Nos. 45000 45000 9 9 8100 53100
Hydrostatic testing of Nitrogen cylinder/ Co2 Flooding cylinder / pilot cylinder as per Latest Gas Cylinder Rules from
authorized agency/Vendor. Hydrotesting of cylinders at vendor shop/Factory to be carried-out with high pressure hose pipe,
calibrated digital pressure gauge, pressure recorder & chart, suitable manifold with fittings and any special requirement.
Dismantling, loading, unloading, to and fro transportation, re-filling, re-installation shall paid as per relevant SOR. No
249 separate charges shall be paid for manpower, consumables,lifting equipments, tools & tackles used during execution of this
activity.
CO2 Flooding cylinder - Water Capacity:68 Litress 20 Nos. 2900 58000 9 9 10440 68440
Nitrogen Gas pilot cylinder - water capacity : 6.8Litress 1 Nos. 2900 2900 9 9 522 3422
Nitrogen Gas cylinder- water capacity : 48Litress 10 Nos. 2900 29000 9 9 5220 34220
Hydrostatic testing of double length Line Pipe( approx. 24 meter) at max. pressure of 150 brag. Job includes arrangement of
Header/ Dish end (end cap) for installation of calibrated pressure gauge, water inlet, drain, vent; welding,NDT, cutting,
bevelling and edge preparation after testig job. Submission of report after completion of hydrotest.This includes
loading/unloading of linepipe, header/disc end preparation, tools, tackels, water, Pump, corrosion inhibitor, equipment,
manpower, etc. required for execution of job.
6"NB 2 Nos. 20000 40000 9 9 7200 47200
250 8"NB 2 Nos. 30000 60000 9 9 10800 70800
12"NB 2 Nos. 40000 80000 9 9 14400 94400
16"NB 2 Nos. 50000 100000 9 9 18000 118000
18"NB 2 Nos. 70000 140000 9 9 25200 165200
24"NB 2 Nos. 90000 180000 9 9 32400 212400
30"NB 2 Nos. 105000 210000 9 9 37800 247800
36"NB 2 Nos. 110000 220000 9 9 39600 259600
Hiring of following equipments for doing any emergency work with all required valid test certificates. The period of hiring
will start after the equipment reaches at site and ends when equipment leaves the site. Break down period of equipment will
not be paid. Normal working time per day will be 8 Hrs. Rate for idle time shall be 50%. Night is not included in idle time
except if works will continue in night. Hiring rates is inclusive of diesel, operators, maintenance cost, loading/unloading of
equipments by Hydra/manual at site.
Dewatering pump of capacity 20KL with required capacity D.G.Set 30 Per Hour 400 12000 9 9 2160 14160
Diaphragm pump of capacity 20KL with required capacity D.G.Set 1 Per Hour 400 400 9 9 72 472
Air Compressor of capacity 100-240CFM with required capacity D.G.Set 1 Per Hour 590 590 9 9 106.2 696.2
251
251 Air Compressor of capacity 75 CFM with required capacity D.G.Set 2 Per Hour 400 800 9 9 144 944
Hydra of lifting capacity 10MT to 15 MT along with required wire ropes & D-Shackle 300 Per Hour 1450 435000 9 9 78300 513300
Crane of capacity 20MT along with required wire ropes & D-Shackle 6 Per Hour 3000 18000 9 9 3240 21240
Crane of capacity up to 50MT along with required wire ropes & D-Shackle 1 Per Hour 3500 3500 9 9 630 4130
Plate - compactor 1 Per Hour 250 250 9 9 45 295
15KVA DG set: 10 Per Hour 630 6300 9 9 1134 7434
JCB 125 Per Hour 1100 137500 9 9 24750 162250
Back-hoe With Rock Breaker 1 Per Hour 3900 3900 9 9 702 4602
Tractor Mounted Pneumatic Type Rock Breaker 1 Per Hour 3500 3500 9 9 630 4130
Schedule of rates for extra works for manpower supply
Qualified Welder 30 1400 42000 9 9 7560 49560
Fitter/Grinder 150 950 142500 9 9 25650 168150
Electrician/ Wireman 350 1100 385000 9 9 69300 454300
Per 8 Hr.
Instrument Technician / Tubing Fitter 550 1170 643500 9 9 115830 759330
252
Rigger 700 850 595000 9 9 107100 702100
Helper/Unskilled Labour 1650 600 990000 9 9 178200 1168200
Plumber 1 Per 8 Hr. 1600 1600 9 9 288 1888
Mason 1 Per 8 Hr. 1800 1800 9 9 324 2124
Carpenter 1 Per 8 Hr. 1800 1800 9 9 324 2124
Updation of As-Built drawings like P&ID, GAD, Plot Plan, ISO, Alignment Sheet etc. (including taking of required
253 1 Per Drawing 25000 9 9 4500 29500
measurement from Site) after modifications. 25000
Preparation of Engineering Drawings such as P&ID, GAD, HAC, ISO, Plotplan, Alignment Sheets, Crossing Drawings, etc
254 (including taking of required measurement from Site). Final approved copy of drawing along with submission of editable 1 Per Drawing 25000 9 9 4500 29500
Auto-Cad file and one printed copy in A2 size shall be entitled for redemption of this SoR 25000
Checking & Maintenance of Instrument Panel: The job shall include cleaning of the panel from outside and inside by
vaccum cleaner / Manual, checking of Indication Lamp, Hooter, Fuses, and sealing of the open cable entries by PVC/GI
255 blind plug . The job shall also include Identification, termination & proper Dressing of Cable. All required tools, tackles, 20 Nos. 60000 9 9 10800 70800
manpower and PVC/GI blind plug shall be in contractor's scope. The report submission in GSPL approved format is also
part of the job. The job shall be caarried out by qualified instrument technician /electrician. 3000
Supply & Installation of GSPL approved makes Cooling/Ventilation fan along with safety grill and dust preventor in
control panel 4” axial fan 220V Ball baring
256
Size : 4” axial fan 220V Ball baring with finger guard 10 Nos. 1500 15000 9 9 2700 17700
Size : 6” axial fan 220V Ball baring with finger guard 1 Nos. 1900 1900 9 9 342 2242
257 Supply of panel cover for modular piano switches of different sizes 1 Nos. 650 650 9 9 117 767
Supply & Replacement of door hinges in instrument local control panel / RTU panel / DCIU panel, Make: Rittal. The job
258 18 Nos. 18000 9 9 3240 21240
shall be caarried out by qualified instrument technician /electrician. 1000
Supply & Replacement of door Lock in instrument local control panel / RTU panel / DCIU panel/Electrical panels, Make:
259 35 Nos. 10500 9 9 1890 12390
Rittal. The job shall be caarried out by qualified instrument technician /electrician. 300
Supply & Replacement of GSPL approved make Tube light including lamp,choke and fixure for panel door in instrument
260 local control panel / RTU panel / DCIU panel, Make: Rittal. The job shall be caarried out by qualified instrument technician 3 Nos. 1200 9 9 216 1416
/electrician. 400
Supply & Replacement of GSPL approved make Selector switch in Instrument local control panel.The job shall be caarried
261 1 Nos. 650 9 9 117 767
out by qualified instrument technician /electrician. 650
Supply & Replacement of GSPL approved make Panel Hooter, Supply Voltage 230Vac / 24 Vdc as per GSPL requirement
262 1 Nos. 1200 9 9 216 1416
for instrument panel and F & G and CO2 flooding system 1200
Supply & Replacement of GSPL approved make FLP & WP Field Hooter , Supply Voltage 230Vac / 24 Vdc as per GSPL
263 3 Nos. 12000 9 9 2160 14160
requirement for Gas Detection System. 4000
Supply & Replacement of GSPL approved make i.e. Sudhir Switchgear - FLP & WP Flasher (Yellow/Red) , Supply Voltage
264 6 Nos. 39000 9 9 7020 46020
230Vac / 24 Vdc as per GSPL requirement for Gas Detection System. 6500
Supply & Replacement of Point gas Detector GSPL approved make & model Crowcon XgardIR and Det-tronics PIRECL/
265 other approved make with control card and full intregration as per the given specification by EIC and as per GSPL 1 Nos. 125000 9 9 22500 147500
requirement for Gas Detection System. 125000
Supply & replacement of Interconnecting Hose Pipe 1/4" dia for CO2 Cylinder , Make: GSPL approved vendor. Hose pipe
266 1 Nos. 780 9 9 140.4 920.4
hydrotest certificate to be submitted. 780
Supply & replacement of Electrical Weight indicator Actuator on Co2 Cylinder with interconnection cable with adapter,
267 3 Nos. 4500 9 9 810 5310
Make:GSPL approved vendor 1500
268 Supply & replacement of Manual call point, Make:GSPL approved vendor 1 Nos. 850 850 9 9 153 1003
269 Supply & replacement of Electrical Fire Exit Glow Board, Make:GSPL approved vendor 1 Nos. 2500 2500 9 9 450 2950
270 Supply & Replacement of Power Supply Converter, 230 Vac to 24 Vdc, 10A approved makes : GSPL approved vendor 1 Nos. 1500 9 9 270 1770
1500
271 Supply of solenoid valve of Kirloskar/Cummins/ Crompton Greaves Make 1 Nos. 9500 9500 9 9 1710 11210
272 Supply & installation of floating mechanical fuel gauge on fuel tank of Kirloskar/Cummins/ Crompton Greaves Make 1 Nos. 2250 2250 9 9 405 2655
273 Supply and replacement of display of Kirloskar/Cummins/ Crompton Greaves Make 1 Nos. 5500 5500 9 9 990 6490
274 Repairing of display panel and programming of Kirloskar/Cummins/ Crompton Greaves Make 1 Nos. 12500 12500 9 9 2250 14750
275 Supply and replacement of ignition key of Kirloskar/Cummins/ Crompton Greaves Make 1 Nos. 1750 1750 9 9 315 2065
276 Supply and installation of door hinges and locks for DG set canopy 1 Nos. 1400 1400 9 9 252 1652
277 Repair of 12 V DG battery charger 1 Nos. 1800 1800 9 9 324 2124
Supply and replacement of Gland packings of Globe Valves (from 2" to 10"). Gland Packing to be purchase from GSPL
278 10 Nos. 15000 9 9 2700 17700
Approved Vendor/OEM of Valve. 1500
Supply and installation of caution board/danger notice on electrical panel as per IS 2551 having skull and bone sign with
279 1 Nos. 450 9 9 81 531
volatage level. 450
Servicing & Maintenance of EOT Crane (Overhead Crane) of capacity mentioned below for General Servicing & checking
of Long Travel, Cross Travel & Hoist Mechanism including following activities
1) Checking of Travelling speed for LT,CT & Hoist.
2) Checking the condition of Main Hoist Wire Rope
3) Operational check for Gear box of LT,CT & Hoist to check the condition of Gears & Oil.
4) Cleaning & checking of Girder
280 5) Checking of Brake Disc/Brake Pads/Brake Liners
6) Checking of Push Button Controls, Operation of Motors, Variable Frequency Drives (VFD), Limit Switches, Breaking
Resistors & Bus Bars. No separate charges shall be paid for manpower, consumables, tools & tackles used during execution
of this activity.

5 Ton 1 Nos. 20000 20000 9 9 3600 23600


10 Ton 1 Nos. 25000 25000 9 9 4500 29500
Supply of DM water as per the requirement at designated store. Transporation, manpower and containers are in contractor's
281 1 Litres 62 9 9 11.16 73.16
scope. 62
Operation of 125 KVA, 2 Nos. D.G sets on round the clock basis by placing at least three experienced personnel and
282 12 Per Month 660000 9 9 118800 778800
maintain hourly logs, D.G. sets dialy checks, diesel filling, water filling as per EIC requirement 55000
283 Supply and installation of Hot insulation with GI cladding by filling glass wool as per EIC requirement. 1 Sq. Mtr. 4000 4000 9 9 720 4720
284 Overhauling of the jockey Centrifugal pump (01 Nos.) and Main centrifugal pump (02 Nos.) of the Fire hydrant system. 1 Nos. 19005 19005 9 9 3420.9 22425.9
Supply & installation of FRP sheet as per thickness mentioned below of approved colour on roofing and sides of Metering
system or DG Sets as per manufacturer’s instructions including providing sealant in the overlapping portion of sheets 1
complete and including all accessories.
285 3 MM 20 SQ FT 120 2400 9 9 432 2832
5 MM 1 SQ FT 500 500 9 9 90 590
8 MM 1 SQ FT 600 600 9 9 108 708
10 MM 1 SQ FT 800 800 9 9 144 944
Supply & Installation of different type of TLP units. This includes Transportation, Cable termination and Jointing, Tagging,
Excavation, Civil work, Jointing with old cables with epoxy hardener.
A 15 Nos. 20000 300000 9 9 54000 354000
B 2 Nos. 25000 50000 9 9 9000 59000
286 C 2 Nos. 20000 40000 9 9 7200 47200
D 5 Nos. 20000 100000 9 9 18000 118000
E 1 Nos. 25000 25000 9 9 4500 29500
H 1 Nos. 25000 25000 9 9 4500 29500
I 1 Nos. 10000 10000 9 9 1800 11800
Pin brazing for CP system, job includes removal of coating, pipe surface preparation, supply & installation of Cable,
materials, consumbles (epoxy hardener application, etc.), manpower, equipments. Job also includes excavation up to
287 20 Nos. 100000 9 9 18000 118000
pipleine depth of maxium of 5.5 meters in case pipe is under ground and locate the point, dewatering, backfilling,
restoration. 5000
Removal and Re-installation of Turbine Meter of size mentioned below, Profiler Plate, Spool Piece Between Profiler Plate
to Meter , Upstream Spool Piece of Profiler, Spool Piece between Meter and Metering Temperature Measurement. No
separate charges shall be paid for manpower, consumables,lifting equipments, valve operations, tools & tackles used during
288 execution of this activity. Gasket shall be supplied by GSPL at designated store.
2" 1 Nos. 1200 1200 9 9 216 1416
3" 1 Nos. 1200 1200 9 9 216 1416
Removal and Re-installation of Senior Orifice Meter of size mentioned below, Profiler Plate , Spool Piece Between Profiler
Plate to Meter , Upstream Spool Piece of Profiler , Spool Piece between Meter and Metering Temperature Measurement.
No separate charges shall be paid for manpower, consumables,lifting equipments, valve operations, tools & tackles used
289 during execution of this activity. Gasket shall be supplied by GSPL at designated store.
2" 1 Nos. 1400 1400 9 9 252 1652
3" 1 Nos. 1400 1400 9 9 252 1652
Removal and Re-installation of Ultrasonic Meter of size mentioned below , Profiler Plate , Spool Piece Between Profiler
Plate to Meter , Upstream Spool Piece of Profiler , Spool Piece between Meter and Metering Temperature Measurement.
No separate charges shall be paid for manpower, consumables,lifting equipments, valve operations, tools & tackles used
during execution of this activity. Gasket shall be supplied by GSPL at designated store.
4" 1 Nos. 1200 1200 9 9 216 1416
290
6" 4 Nos. 2400 9600 9 9 1728 11328
8" 1 Nos. 4980 4980 9 9 896.4 5876.4
10" 1 Nos. 4980 4980 9 9 896.4 5876.4
12" 1 Nos. 6300 6300 9 9 1134 7434
16" 1 Nos. 6300 6300 9 9 1134 7434
Removal and Re-installation of Turbine Meter of size mentioned below. No separate charges shall be paid for manpower,
consumables,lifting equipments, valve operations, tools & tackles used during execution of this activity. Gasket shall be
291 supplied by GSPL at designated store.
2" 1 Nos. 1190 1190 9 9 214.2 1404.2
3" 1 Nos. 1190 1190 9 9 214.2 1404.2
Removal and Re-installation of Ultrasonic Meter of size mentioned below. No separate charges shall be paid for
manpower, consumables,lifting equipments, valve operations, tools & tackles used during execution of this activity. Gasket
shall be supplied by GSPL at designated store.
4" 1 Nos. 2400 2400 9 9 432 2832
292 6" 1 Nos. 3100 3100 9 9 558 3658
8" 1 Nos. 3800 3800 9 9 684 4484
10" 1 Nos. 4400 4400 9 9 792 5192
12" 1 Nos. 5000 5000 9 9 900 5900
16" 1 Nos. 5500 5500 9 9 990 6490

Removal and Re-installation of Regulator Valve ( Either Active or Monitor) of size mentioned below. Size of regulator
valve to be considered as per Inlet size of Regulator. No separate charges shall be paid for manpower, consumables,lifting
equipments, tools & tackles used during execution of this activity. Gasket shall be supplied by GSPL at designated store.

1" 1 Nos. 2500 2500 9 9 450 2950


293 1.5" 1 Nos. 2500 2500 9 9 450 2950
2" 1 Nos. 3000 3000 9 9 540 3540
2.5" 1 Nos. 3500 3500 9 9 630 4130
3" 1 Nos. 4000 4000 9 9 720 4720
4" 1 Nos. 5500 5500 9 9 990 6490
6" 4 Nos. 6000 24000 9 9 4320 28320
Removal and Re-installation of SSV Valve of size mentioned below. No separate charges shall be paid for manpower,
consumables,lifting equipments, tools & tackles used during execution of this activity. Gasket shall be supplied by GSPL at
designated store.
1" 1 Nos. 2500 2500 9 9 450 2950
1.5" 1 Nos. 2500 2500 9 9 450 2950
2" 1 Nos. 3000 3000 9 9 540 3540
294
2.5" 1 Nos. 3500 3500 9 9 630 4130
3" 1 Nos. 4000 4000 9 9 720 4720
4" 1 Nos. 5500 5500 9 9 990 6490
6" 1 Nos. 6000 6000 9 9 1080 7080
8" 1 Nos. 7000 7000 9 9 1260 8260
10" 1 Nos. 7500 7500 9 9 1350 8850
Removal and Re-installation of Flow Control Valve of size mentioned below. No separate charges shall be paid for
manpower, consumables,lifting equipments, tools & tackles used during execution of this activity. Gasket shall be supplied
by GSPL at designated store.
1" 1 Nos. 990 990 9 9 178.2 1168.2
1.5" 1 Nos. 990 990 9 9 178.2 1168.2
2" 1 Nos. 990 990 9 9 178.2 1168.2
295
3" 1 Nos. 1090 1090 9 9 196.2 1286.2
4" 1 Nos. 2200 2200 9 9 396 2596
6" 1 Nos. 3000 3000 9 9 540 3540
8" 1 Nos. 3500 3500 9 9 630 4130
10" 1 Nos. 4300 4300 9 9 774 5074
12" 1 Nos. 5000 5000 9 9 900 5900
Supply, fabrication and installtion of Vent line Flapper(Brass) with perforated wiremesh in Brass material. The Job includes
dismantle the vent pipe and refitting as found position after fabrication. No seperate charges shall be paid for manpower,
dismantling spool, welding and refitting the same. Cosumable like Gasket shall be provided by GSPL
Upto 2" 1 Nos. 3000 3000 9 9 540 3540
3" 1 Nos. 4000 4000 9 9 720 4720
296 4" 1 Nos. 5000 5000 9 9 900 5900
6" 1 Nos. 6000 6000 9 9 1080 7080
8" 1 Nos. 7000 7000 9 9 1260 8260
10" 1 Nos. 10000 10000 9 9 1800 11800
12" 1 Nos. 12000 12000 9 9 2160 14160
16" 1 Nos. 14000 14000 9 9 2520 16520
Supply and installtion of Vent line Flapper(Brass material). The Job includes instalation of flapper in propser position. No
seperate charges shall be paid for manpower.
Upto 2" 1 Nos. 2400 2400 9 9 432 2832
3" 1 Nos. 3000 3000 9 9 540 3540
4" 1 Nos. 4000 4000 9 9 720 4720
297 6" 1 Nos. 5000 5000 9 9 900 5900
8" 1 Nos. 6000 6000 9 9 1080 7080
10" 1 Nos. 8000 8000 9 9 1440 9440
12" 1 Nos. 10000 10000 9 9 1800 11800
16" 1 Nos. 13000 13000 9 9 2340 15340
1 0 9 9 0 0
Cold Cutting Activity for Joint/Pipe of different sizes. This inclides all tools, tackels, consumables, equipment, manpower,
etc. to perform this job.
Up to 3" 1 Inch. Dia. 5000 5000 9 9 900 5900
4" 1 Inch. Dia. 5000 5000 9 9 900 5900
6" 1 Inch. Dia. 5500 5500 9 9 990 6490
8" 1 Inch. Dia. 5500 5500 9 9 990 6490
298
12" 1 Inch. Dia. 6000 6000 9 9 1080 7080
16" 1 Inch. Dia. 6500 6500 9 9 1170 7670
18" 1 Inch. Dia. 7000 7000 9 9 1260 8260
24" 1 Inch. Dia. 7500 7500 9 9 1350 8850
30" 1 Inch. Dia. 8000 8000 9 9 1440 9440
36" 1 Inch. Dia. 8500 8500 9 9 1530 10030
Removal and Re Fitment of Spool Piece between Profiler Plate to Meter of size mentioned below.No separate charges shall
be paid for manpower, consumables,lifting equipments, valve operations, tools & tackles used during execution of this
activity. Gasket shall be supplied by GSPL at designated store.

299
2" 1 Nos. 1400 1400 9 9 252 1652
3" 1 Nos. 2000 2000 9 9 360 2360
299 4" 1 Nos. 2900 2900 9 9 522 3422
6" 1 Nos. 7000 7000 9 9 1260 8260
8" 1 Nos. 7000 7000 9 9 1260 8260
10" 1 Nos. 12000 12000 9 9 2160 14160
12" 1 Nos. 12000 12000 9 9 2160 14160
16" 1 Nos. 12000 12000 9 9 2160 14160
300 Maintenance of Solar Lights. 1 Nos. 2000 2000 9 9 360 2360
Supply and replacement of solar light spares
Solar Module
(Vikram Solar, Waree Solar,Goldi green technologies pvt ltd, Tata power solar systems pvt.ltd, Solar systmes pvt.ltd, Moser
1 Nos. 55000 9 9 9900 64900
bear solar limited, XL energy limited, Solar semiconductor, Emmvee photovoltaics pvt ltd ,Navitas green solutions pvt ltd,
301 Satvik, Panchwakr solar, Surana solar) 55000
Photovoltaic Battery 12V 150AH
1 Nos. 20000 9 9 3600 23600
( Exide, Okaya, Luminous, Relicell, Artheon, Su-kam, base, Southern, HBL, Gem) 20000
Charge Controller
1 Nos. 4500 9 9 810 5310
(Systeller, Flin energy, SuKam, UTL Inverter, Luminous) 4500
LED Street light Fixtures Solar Lighting Poles
(Philips, Crompton, Wipro, Havells, Oreva, Charlson, Syska, Moser bear, Surya, Bajaj)
LED Luminarie Fixture 09 -12 Watts 1 Nos. 1800 1800 9 9 324 2124
LED Luminarie Fixture 18 - 24 Watts 1 Nos. 2400 2400 9 9 432 2832
LED Luminarie Fixture 30 - 43 Watts 1 Nos. 5100 5100 9 9 918 6018
Approved make PCB for LED Luminarie Fixture 09 -12 Watts 1 Nos. 300 300 9 9 54 354
302 Approved make PCB for LED Luminarie Fixture 18 - 24 Watts 1 Nos. 500 500 9 9 90 590
Approved make PCB for LED Luminarie Fixture 30 - 43 Watts 1 Nos. 700 700 9 9 126 826
Approved make 12 Volt SMPS for LED Luminarie Fixture 09 -12 Watts 1 Nos. 1500 1500 9 9 270 1770
Approved make 12 Volt SMPS for LED Luminarie Fixture 18 - 24 Watts 1 Nos. 2000 2000 9 9 360 2360
Approved make 12 Volt SMPS for LED Luminarie Fixture 30 - 43 Watts 1 Nos. 2500 2500 9 9 450 2950
Poweder Coated Battery Box 1 Nos. 8100 8100 9 9 1458 9558
Supply, Laying & Terminaltion of 2C x 4 Sq. mm armored power cable 1 R. Mtr. 350 350 9 9 63 413
Supply & Installation (Including removal of existing one) of Ni-CD Battery (NCPP/ VRPP) 1.2 V for UPS system
NCCP 1.2 Volt, 52 AH 1 Nos. 3000 3000 9 9 540 3540
NCCP 1.2 Volt, 100AH 1 Nos. 6000 6000 9 9 1080 7080
303 NCCP 1.2 Volt, 135AH 1 Nos. 10000 10000 9 9 1800 11800
VRPP 1.2 Volt, 166AH 1 Nos. 12000 12000 9 9 2160 14160
NCCP 1.2 Volt, 145AH 1 Nos. 13000 13000 9 9 2340 15340
VRPP 1.2 Volt, 555AH 1 Nos. 25000 25000 9 9 4500 29500
304 PAUT Testing as per instruction of EIC and submission of report 1 Location 24000 24000 9 9 4320 28320
CP Monitoring
PSP & TLP Monitering through Data Logger ( atleast 1 TLP/ KM) 2700 Per Kms 725 1957500 9 9 352350 2309850
CIPL Survey 1 Per Kms 5500 5500 9 9 990 6490
DCVG Survey 1 Per Kms 5500 5500 9 9 990 6490
CAT Survey 1 Per Kms 5500 5500 9 9 990 6490
AC/DC survey 1 Location 4000 4000 9 9 720 4720
305 Software modelling for AC/DC interference survey 1 Per Kms 250000 250000 9 9 45000 295000
ON/OFF Potential Survey 1 Per Kms 1500 1500 9 9 270 1770
TR Unit Preventive Maintenance 1 Nos. 12000 12000 9 9 2160 14160
Monitoring & Preventive Maintenance of AGB 1 Location 15000 15000 9 9 2700 17700
TR Unit Meter Calibration 1 Location 3000 3000 9 9 540 3540
Foreign Pipeline crossing survey 1 Location 4000 4000 9 9 720 4720
ER Probe/CTSU/Corrosion coupon monitoring 1 Location 2000 2000 9 9 360 2360
Dismantling of exisitng battery & re-installation of the same after charging
306 1 Nos. 400 9 9 72 472
(for battery of DG, Inverter, Solar etc.) 400
307 Supply and Installation of Pre cast Cable Route Marker (For Instrumentation and Electrical cables) 1 Nos. 700 700 9 9 126 826
Preparation of cable schedule and termination detailing of existing cables of all panels (E&I, Telecom, Metering,
308 Scada, EPABX, CCTV, GC, etc.) the job is to be executed as per the direction of the GSPL E.I.C. & GSPL 1 per panel 7500 9 9 1350 8850
requirement. 7500

Relocation of panel (Base frame Mounted)- Isolation of the existing panels by Dismantling/ Disconnection of cables,
earthings, tag-weldings etc as to make them fully isolated from the existing setUp and shifting & erection of panels on
MS frame at new location,the job is to be executed as per the direction of the GSPL E.I.C. & GSPL requirement
309 8 per panel 160000 9 9 28800 188800
(separate charges shall be paid for MS steel frame & earthing connectivity as per relevent SOR SOR). The size of
floor mounted panel shall be up to 2100 X 1000 X 1200 (HxDxW) (in mm). The maximum weight shall be consider
up to 2 tons.
20000

Relocation of panel (wall mounted) - Isolation of the existing panels by Dismantling/ Disconnection of cables,
earthings, tag-weldings etc as to make them fully isolated from the existing setUp and shifting & erection of panels on
310 wall or on vertical steel frame at new location.the job is to be executed as per the direction of the GSPL E.I.C. & GSPL 10 per panel 100000 9 9 18000 118000
requirement (separate charges shall be paid for MS steel frame as per relevent SOR). The maximum weight shall be
up to 400 Kg.
10000
Supply, transportation, fabrication and erection of MS steel section (Frame) of various sizes along with required
fasteners (plate, angle, tee, channel, beam etc) for installation of panel. Rate also includes the surface cleaning by a
suitable method, Supply and application of two coat of high build chlorinated rubber / zinc phosphate primer and two
311 coats of finished paint of epoxy of grey colour / colour as specified by GSPL of approved make, the job is to be 1000 per Kg 170000 9 9 30600 200600
executed as per the direction of the GSPL E.I.C. & GSPL requirement. Job inclusive of labour, machinery etc.(No
separate charges shall be paid for transportation of fabricated structure, manpower, equipemnts used during execution
of this activity)
170

Existing Cable to be shifted with panel- Isolation, disconnection, removal of all signal, power, Ethernet & fiber cables
from existing panel at existing location and re-routing of same cable to new panel location by proper cable laying on
cable tray , Cable dressing on cable tray and in panel,Cable glanding, termination in same panel at new location as per
cable schedule and termination detailing prepared by contractor.The rates shall include the Supply and fixing of cable
tags at both end , G.I. saddles / clamps, PVC/HDPE flexible conduit, saddle bars, lugs, ferrules, RJ45 & RJ11
connector for eathernet and telecom cable,Fiber ST/SC/LC/FC connector including crimping, including transportation
with all labor and materials as per the specifications, drawings and directions of Engineer-in-charge . No separate
charges shall be paid for manpower,consumables, tools & tackles used during execution of this activity. Cable joint is
not allowed. Replace all shorts cable as per cable schedule. (Seprate charges shall be paid for Supply of cable,Cable
gland, Cable tray and 24 Core OFC splicing and termination as per relevent SOR)job is to be executed as per the
direction of the GSPL E.I.C. & GSPL requirement

Up to 3 core x 25 sqmm power cable 1 per No 600 600 9 9 108 708


Up to 3 core x 6 sqmm power cable 1 per No 300 300 9 9 54 354
312
Up to 3 Core x 2.5 sqmm power cable 1 per No 200 200 9 9 36 236
2 Core x 2.5 sqmm power cable 1 per No 200 200 9 9 36 236
2 core x 1.5 sqmm power cable 1 per No 200 200 9 9 36 236
Up to 1 sqmm control cable 1 per No 200 200 9 9 36 236
Up to 2 pair x 1.5 sqmm instrument cable 1 per No 200 200 9 9 36 236
Up to 6 pair x 1.5 sqmm instrument cable 1 per No 300 300 9 9 54 354
Up to 12 pair x 1.5 sqmm instrument cable 1 per No 350 350 9 9 63 413
Up to 8 traid x 1.5 sqmm cable 1 per No 300 300 9 9 54 354
CAT 6 Eathernet cable 1 per No 200 200 9 9 36 236
Optical Fiber Patch chord - 1 pair - Up to 25 meter 1 per No 200 200 9 9 36 236
24 Core OFC cable 1 per No 300 300 9 9 54 354
Video Cable 1 per No 200 200 9 9 36 236
Earthing Cable Up to 25 sqmm 1 per No 200 200 9 9 36 236

Existing Cable (not shifted)- Proper cable laying on cable tray, Cable dressing on cable tray and in panel as per cable
schedule and termination detailing prepared by contractor.The rates shall include the Supply and fixing of cable tags at
both end , G.I. saddles / clamps, PVC/HDPE flexible conduit, saddle bars, lugs, ferrules, RJ45 & RJ11 connector for
eathernet and telecom cable,Fiber ST/SC/LC/FC connector including crimping etc, including transportation with all
labor and materials as per the specifications, drawings and directions of Engineer-in-charge . No separate charges shall
be paid for manpower,consumables, tools & tackles used during execution of this activity. (Seprate charges shall be
paid for Supply Cable tray as per relevent SOR)job is to be executed as per the direction of the GSPL E.I.C. & GSPL
requirement

Up to 3 core x 25 sqmm 1 per No 600 600 9 9 108 708


Up to 3 core x 6 sqmm power cable 1 per No 300 300 9 9 54 354
313 Up to 3 Core x 2.5 sqmm power cable 1 per No 200 200 9 9 36 236
2 Core x 2.5 sqmm power cable 1 per No 200 200 9 9 36 236
2 core x 1.5 sqmm power cable 1 per No 200 200 9 9 36 236
Up to 1 sqmm control cable 1 per No 200 200 9 9 36 236
Up to 2 pair x 1.5 sqmm instrument cable 1 per No 200 200 9 9 36 236
Up to 6 pair x 1.5 sqmm instrument cable 1 per No 300 300 9 9 54 354
Up to 12 pair x 1.5 sqmm instrument cable 1 per No 350 350 9 9 63 413
Up to 8 traid x 1.5 sqmm cable 1 per No 300 300 9 9 54 354
CAT 6 Eathernet cable 1 per No 200 200 9 9 36 236
Up to 50 pair Telecom cable 1 per No 200 200 9 9 36 236
Optical Fiber Patch chord - 1 pair - Up to 25 meter 1 per No 300 300 9 9 54 354
24 Core OFC cable 1 per No 200 200 9 9 36 236
Video Cable 1 per No 200 200 9 9 36 236

Supply, Laying & Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed copper armoured Cable
Voltage grade 650 / 1100 Volts of following sizes as per GSPL approved make, on cable trays, supported on steel
structures, in ready made trenches/ cable gallery. The rates shall include the supply and fixing of aluminium number
tags, G.I. saddles / clamps, saddle bars, lugs, ferrules, double compression type SS glands, etc, including transportation
with all labor and materials as per the specifications, drawings and directions of GSPL Engineer-in-charge . The
Insulation Resistance of cable has to be checked & report to be submitted before commissioning. No separate charges
shall be paid for manpower,consumables, tools & tackles used during execution of this activity.(Seprate charges shall
be paid for supply of cable tray as per relevent SOR)job is to be executed as per the direction of the GSPL E.I.C. &
GSPL requirement

314
314
Up to 3 core x 25 sqmm power cable 50 per Mtr. 1175 58750 9 9 10575 69325
Up to 3 core x 6 sqmm power cable 100 per Mtr. 335 33500 9 9 6030 39530
Up to 3 Core x 2.5 sqmm power cable 250 per Mtr. 178 44500 9 9 8010 52510
2 Core x 2.5 sqmm power cable 100 per Mtr. 142 14200 9 9 2556 16756
2 core x 1.5 sqmm power cable 100 per Mtr. 118 11800 9 9 2124 13924
Up to 2 pair x 1.5 sqmm instrument cable 200 per Mtr. 138 27600 9 9 4968 32568
Up to 6 pair x 1.5 sqmm instrument cable 250 per Mtr. 325 81250 9 9 14625 95875
Up to 12 pair x 1.5 sqmm instrument cable 150 per Mtr. 445 66750 9 9 12015 78765
Up to 8 traid x 1.5 sqmm cable 150 per Mtr. 535 80250 9 9 14445 94695
Up to 25 sqmm earthing cable 300 per Mtr. 225 67500 9 9 12150 79650
Supply laying and Termination (using Conduit, Rojet Box ,temrinal block, crimping, connectors) of telecom &
network cables . The Insulation Resistance of cable has to be checked & reported before commissioning. No separate
charges shall be paid for excavation, backfilling, manpower, consumables, equipments, tools & tackles used during
execution of this activity.
Polythene (Solid/Foam Skin) Insulated Jelly Filled Cables Up to 5 Pair 100 per Mtr. 180 18000 9 9 3240 21240
Polythene (Solid/Foam Skin) Insulated Jelly Filled Cables Up to 10 Pair 100 per Mtr. 245 24500 9 9 4410 28910
315
Polythene (Solid/Foam Skin) Insulated Jelly Filled Cables Up to 50 Pair 100 per Mtr. 430 43000 9 9 7740 50740
Flexible 2 pair Telephone cable 250 per Mtr. 48 12000 9 9 2160 14160
Up to 1 sqmm control cable 100 per Mtr. 73 7300 9 9 1314 8614
RG-11 Video Cable 250 per Mtr. 78 19500 9 9 3510 23010
Optical Fiber Patch chord with connector as per GSPL requirement- 1 pair - Up to 25 meter length 10 per Mtr. 350 3500 9 9 630 4130
CAT 6 Eathernet cable 500 per Mtr. 45 22500 9 9 4050 26550
Erection of new HMI console / panel on MS frame/ RCC slab,the job is to be executed as per the direction of the
316 GSPL E.I.C. Job include shifting from ground floor to first floor, using hydra crain etc (separate charges shall be paid 4 per panel 28000 9 9 5040 33040
for MS steel frame & earthing connectivity as per relevent SOR SOR) 7000

Making of Cable entry hole - 4" & 2" on floor by breaking of RCC by using mechanical breaker / Hammer /
Manually / abrasive cutting machine and disposal of the demolished materials within a lead of 1KM. including
317 20 per No 20000 9 9 3600 23600
stacking of steel bars and disposal of unserviceable material within 1KM lead. No separate charges shall be paid for
manpower, consumables, equipments, handling, tools & tackles used during execution of this activity.
1000
Supply and Installation of DIN Rail Mounted Feed ThroughTerminals Type CST in Melamine Housing with end plates
for below mentioned conductor size, RJ 45 Connector.
1.5 sqmm 1 per No 40 40 9 9 7.2 47.2
318
2.5 sqmm 1 per No 50 50 9 9 9 59
Up to 6 sqmm 1 per No 60 60 9 9 10.8 70.8
Up to 10 sqmm 1 per No 90 90 9 9 16.2 106.2
Supply & installation of SS sheet enclosure or Die cast aluminium junction box for field cable joint in case of short
along with all provisions for cable entry, glands, terminals, accessories like studs & washers
SS sheet enclosure Size 300 x 300 - 48 terminal 1 per No 4500 4500 9 9 810 5310
319
SS sheet enclosure Size 600 x 600 - 96 terminal 1 per No 8500 8500 9 9 1530 10030
Die cast aluminium junction box- Size 300 x 300 - 48 terminal 1 per No 6000 6000 9 9 1080 7080
Die cast aluminium junction box-Size 600 x 600 - 96 terminal 1 per No 12000 12000 9 9 2160 14160
320 OFC Splicing at panel in FTC including pigtels and termination of 24 core in Telecom panel 3 per Joint 7000 21000 9 9 3780 24780

Complete Link Testing End to End with Power Source, Laser Source, OTDR meter working with 1310 nm and 1550
321 nm from both end including Pigtails, Patch cord for testing. And submission of all 24 core OTDR traces between two 3 per Cable 21000 9 9 3780 24780
terminals or across the joints.(Before & after of OFC splicing)
7000

Supply & installation of solid state, chassis mounted, Adjustable Output, Load Sharing, Remote On/Off, Remote
Sense, 3kV Volatge Isolation, Universal Input power supply module (AC-DC) for control panels.
322 2 per No 150000 9 9 27000 177000
Input:100~240 VAC, 4.1A, Output: 24V, 300W, 14A.
Certification: CE, RoHS & ULcompliant.

75000
Supply & installation of (2100mm H (inclusive of 100mm Base channel) x 800mm D x 1000mm W) 42U Floor
mounted, Freestanding, Vertical panel.
Material: Min. 2 mm thickness CRCA sheet metal. Thickness of panel front & Mounting Plate & Gland Plate shall be
3 mm. Top & Bottom cover with cable entry gland plates.
Cabinet Finish: Sand blasting, grinding, chemical cleaning, surface finishing by suitable filter and two coats of high
grade lacquer with wet sanding between two coats.
Panel Paint: RAL-7032 , Siemens Grey for Body / Black for Base Frame.
Protection: Min. IP-42, as per IS – 2147.
Doors: To be provided with lockable handles (flush pull chrome plated handles) and concealed hinges with pull pins
for easy door removal. Panel Doors shall be provided with pockets for storing of manuals/ drawings etc. The racks
must have steel front / rear doors and side panels. Racks should NOT have glass doors / panels.
Lifting Hooks: Removable hooks to be provided for lifting purpose.
323 1 per No 40000 9 9 7200 47200
Accessories (Minimum): Door Switch Operated Light, Thermostat operated space heater, Fans and Fan Tray: 230V
AC, 4" dia (4 Nos. per Rack) setting should be factory settable. This unit should also include - humidity & temperature
sensor, 15A power supply socket, Instrument / Electronic Earth bus 25 x 6mm copper, Body Earth bus 25 x 6mm
copper, Telephone jack,
Power distribution: by MCB & Fused terminals.
Depth support channels: 3 pairs with an overall weight carrying Capacity of 500Kgs.
Must be lockable with unique key for each rack, Panel should have Rear Cable Management channels, Wire managers:
Two vertical and four horizontal
Power Distribution Unit: Vertically Mounted with appropriate number of Power Outputs. (A combination of IEC 320
C13 Sockets & IEC 320 C19 ), Electronically controlled circuits for Surge & Spike protection, 32AMPS MCB, 5 KV
AC isolated input to Ground & Output to Ground.

40000

PART-B: Civil Activities


Earth work in excavation below ground level for all kinds of work in basements, foundations, including trenches etc.
including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, leveling, grading and ramming
of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and
disposal or stacking of excavated material within a lead of 1 KM, as decided including providing temporary supports to
existing service lines like water pipes sewage pipes, electric overhead and underground cables etc. all complete, including
324 shoring and strutting. No separate charges shall be paid for manpower, consumables, equipments, handling, tools & tackles
used during execution of this activity.
Soft soil upto 2.5 meter 750 Cu. Mtr. 390 292500 9 9 52650 345150
Below 2.5 meter 125 Cu. Mtr. 430 53750 9 9 9675 63425
Hard rock upto 2.5 meter 70 Cu. Mtr. 500 35000 9 9 6300 41300
Hard rock below 2.5 meter 2 Cu. Mtr. 550 1100 9 9 198 1298
Back-filling of available excavated earth (excluding rock) in trench, sides of foundation etc in layers not exceeding 20 cm in
depth consolidating earth deposited layer by ramming and watering, lead up to 100 Mtr. and filling up to required Ground
325 750 Cu. Mtr. 150000 9 9 27000 177000
level. No separate charges shall be paid for manpower, consumables, equipments, handling, tools & tackles used during
execution of this activity. 200
Breaking of PCC by using mechanical breaker / Hammer / Manually / abrasive cutting machine and disposal of the
326 demolished materials within a lead of 1KM. No separate charges shall be paid for manpower, consumables, equipments, 12 Cu. Mtr. 15240 9 9 2743.2 17983.2
handling, tools & tackles used during execution of this activity. 1270
Breaking of RCC by using mechanical breaker / Hammer / Manually / abrasive cutting machine and disposal of the
demolished materials within a lead of 1KM. including stacking of steel bars and disposal of unserviceable material within
327 1 Cu. Mtr. 5500 9 9 990 6490
1KM lead. No separate charges shall be paid for manpower, consumables, equipments, handling, tools & tackles used
during execution of this activity. 5500
Supply & filling of Good Quality Sand in trench, sides of foundation, bottom of foundations for FML skid/piping supports
etc in layers not exceeding 100 mm in depth consolidating each layer by ramming and watering up to required level. No
328 1 Cu. Mtr. 1000 9 9 180 1180
separate charges shall be paid for manpower, consumables, equipments, handling, tools & tackles used during execution of
this activity. 1000
Supply & filling Rubble Soiling (200-250 mm thick) in trench, bottom of foundations for FML skid/piping supports etc up
329 to required level complete as per drawings, specifications and as directed by EIC. No separate charges shall be paid for 30 Sq. Mtr. 38400 9 9 6912 45312
manpower, consumables, equipments, handling, tools & tackles used during execution of this activity. 1280

Providing, mixing and laying binding layer of PCC Grade of 1:3:6 nominal mix using 40 mm and downgraded coarse
aggregate for any thickness below footings, plinth beams, foundations, trenches, pits & sumps etc. using ordinary Portland
330 cement, curing etc., complete as per drawings, specifications and as directed by EIC. Centring & Shuttering is also in the 25 Cu. Mtr. 130000 9 9 23400 153400
scope. No separate charges shall be paid for manpower, consumables, equipments, handling, tools & tackles used during
execution of this activity.
5200
Providing reinforcement (HYSD bars) for RCC work including bending, binding and placing in position complete as per
standard ISI 422 part 1. Transportation, loading, unloading & handling of materials to site are included. No separate charges
331 3300 Kg 330000 9 9 59400 389400
shall be paid for manpower, consumables,lifting equipments, handling, tools & tackles used during execution of this
activity. 100

Providing RCC work M15 1:2:4 (1cement, 2 coarse sand , 4 graded stone aggregate size 20mm nominal size) in support,
332 foundation, footing, pavements, floors etc. This job includes providing Centering and shuttering, strutting, propping and 100 Cu. Mtr. 620000 9 9 111600 731600
removal of form with all tools / tackles / labour /machinery etc. Charges of HYSD bars shall be paid as per relevent SOR.
6200
Providing RCC work M20 1:1.5:3 (1cement, 1.5 coarse sand , 3 graded stone aggregate size 20mm nominal size) in
support, foundation, footing, pavements, floors etc. This job includes providing Centering and shuttering, strutting,
333 1 7200 9 9 1296 8496
propping and removal of form with all tools / tackles / labour /machinery etc. Charges of HYSD bars shall be paid as per
relevent SOR. 7200

Providing RCC work M25 1:1:2 (1cement, 1 coarse sand , 2 graded stone aggregate size 20mm nominal size) in support,
334 foundation, footing, pavements, floors etc. This job includes providing Centering and shuttering, strutting, propping and 1 7400 9 9 1332 8732
removal of form with all tools / tackles / labour /machinery etc. Charges of HYSD bars shall be paid as per relevent SOR.
7400
12mm thick plaster in 1:4 cement-mortar, providing & applying finish cement plaster at all heights, levels and places,
335 including scaffolding, chipping, roughing up the concrete , curing and finishing . No separate charges shall be paid for 100 Sq . Mtr. 35000 9 9 6300 41300
manpower, consumables, equipments, scaffolding, handling, tools & tackles used during execution of this activity. 350
Demolishing brick work in cement mortar including staking of serviceable materials and disposal of unserviceable material
336 1 Cu. Mtr. 1700 9 9 306 2006
within 1KM lead including transportation/labour etc. 1700
Providing and laying 50 B Class Brick Masonry Work in foundation / superstructure with Cement Mortar 1:6 (1 Cement: 6
Coarse Sand) as per specifications in one or more brick thickness and in any standard shape (excluding circular/curved)
including providing recesses, opening, scaffolding, staging, curing, finishing the joints flush below ground level and raking
337 out joints in and above plinth level etc. all complete.
At all depths below and upto 2.5 Mtr. from Ground level 1 Cu. Mtr. 6000 6000 9 9 1080 7080
At all heights above 2.5 Mtr. from Ground Level 1 Cu. Mtr. 6500 6500 9 9 1170 7670
Dismantling and stacking of damaged lighting pole of sizes upto15M including excavation, cutting etc.& backfilling if
required, completion of job in totality to the satisfaction of EIC within a lead of 100Mtr. The safe removal of existing
338 luminaire, JBs, Earthing connection, cable connection etc. from the pole and handing over of same to GSPL is in 20 Nos. 80000 9 9 14400 94400
contractor's scope. No separate charges shall be paid for manpower, consumables,lifting equipments, handling, tools &
tackles used during execution of this activity. 4000
Relocation of Lighting / Solar pole within the terminal which includes removal with or without RCC foundation & re-
installation with proper foudation , concrete support etc. complete in all respect. This also includes leveling of old
foundation location & backfilling if required, with all tools/tackles/labour/machinery/Hydra etc. Removal of fixtures, JB,
339 7 Nos. 39200 9 9 7056 46256
earthing connections, Cable connections from pole at old location & reconnection and testing of all the system at new
location is included in the scope.
In case of relocation of pole to other terminal the transportation shall be given as per the relevant SOR. 5600
Painting, Numbering & Lettering of existing pipeline markers and painting of vent pipes in cased crossings including
Supply of paint and application of 2 coats of red-oxide primer and 2 coats of zebra strip (black and golden yellow stripes)
of approved quality to give an even shade after proper scraping of existing paint and clearing of surface free from foreign
materials. The rate are including man/ material and transportation to the position / site.
Vent Pipes 1 Sq. Mtr. 120 120 9 9 21.6 141.6
Direction Marker 175 Nos. 1200 210000 9 9 37800 247800
340 Warning Marker 220 Nos. 1200 264000 9 9 47520 311520
K.M. Marker 75 Nos. 1200 90000 9 9 16200 106200
Aerial Marker 20 Nos. 1200 24000 9 9 4320 28320
OFC Marker 1 Nos. 450 450 9 9 81 531
Navigation Marker 1 Nos. 2890 2890 9 9 520.2 3410.2
RoU Boundary Marker 100 Nos. 590 59000 9 9 10620 69620
TLP 4 Nos. 1900 7600 9 9 1368 8968
Supply of Station approach road direction markers including stenciling the logo, arrow markers & signs; to be installed at
roadsides as per the specimen drawing DRW. No. GSPL-AMC-STD-14 enclosed including supply of all materials for
grouting in 1:3:6 PCC mixtures to correct line, level and direction. The work also includes transportation to site of
341 4 Nos. 36000 9 9 6480 42480
installation, necessary excavation for grouting of post, cleaning under ground portion upto 300 mm height from the ground
level. No separate charges shall be paid for manpower, consumables,lifting equipments, handling, tools & tackles used
during execution of this activity. 9000
Supply, transportation & installation of Navigation Marker (of size 5m X 2m with required chanels for grouting) at River
Crossing including painting, stenciling the logo, arrow markers & signs as per specimen drawing DRW. No. GSPL-AMC-
342 STD-10 enclosed. The Job includes supply of all materials for grouting in 1:3:6 PCC mixtures to correct line, level and 1 Nos. 10000 9 9 1800 11800
direction. The work also includes transportation to site of installation, necessary excavation for grouting of post, cleaning
ground portion upto 300 mm height from the ground level & restoration. 10000
Stenciling of English / Gujarati / numerical letters on sign boards and markers wherever required as per directed by GSPL
E-I-C:
Aerial Marker as per DWG. No. GSPL-AMC-STD-08 20 Nos. 700 14000 9 9 2520 16520
K.M. Marker as per DWG. No. GSPL-AMC-STD-09 12 Nos. 700 8400 9 9 1512 9912
343 Direction Marker as per DWG. No. GSPL-AMC-STD-10 6 Nos. 700 4200 9 9 756 4956
Warning Marker as per DWG. No. GSPL-AMC-STD-11 1 Nos. 700 700 9 9 126 826
OFC Marker as per DWG. No. GSPL-AMC-STD-05 1 Nos. 700 700 9 9 126 826
Navigation Markeras per DWG. No. GSPL-AMC-STD-? 2 Nos. 1500 3000 9 9 540 3540
Sign Board as per DWG. No. GSPL-AMC-STD-14 12 Nos. 700 8400 9 9 1512 9912
Supply, transportation and installation of new direction marker / warning Marker on pipeline RoU as per DWG. No. GSPL-
AMC-STD-10 / GSPL-AMC-STD-11 including supply of all materials for fabrication, cleaning, two coats of red-oxide and
two coats of zebra color (black and golden yellow strips) of approved quality (I S I Mark) paint and marking the number,
direction, chainage and pipe size. Excavation upto required size, grouting in 1:3:6 PCC mixture to correct line, level and
direction, back-filling & restoration. The work is to be executed as per drawing and direction E.I.C. No separate charges
344 shall be paid for manpower, consumables, transportation, lifting equipments, handling, tools & tackles used during
execution of this activity.
Type-I, For normal soil 25 Nos. 8500 212500 9 9 38250 250750
Type-II, For drifting sand soil 1 Nos. 9200 9200 9 9 1656 10856
Type-III, For Rocky areas 1 Nos. 9200 9200 9 9 1656 10856
Supply, transportation and installation of new Arial marker on pipeline RoU as per DWG. No. GSPL-AMC-STD-08
including supply of all materials for fabrication, cleaning, two coats of red-oxide and two coats of zebra color (black and
golden yellow strips) of approved quality (I S I Mark) paint and marking the number, direction, chainage and pipe size.
Excavation upto required size, grouting in 1:3:6 PCC mixture to correct line, level and direction, back-filling & restoration.
345 The work is to be executed as per drawing and direction E.I.C. No separate charges shall be paid for manpower,
consumables, transportation, lifting equipments, handling, tools & tackles used during execution of this activity.

Type-I, For normal soil 5 Nos. 8500 42500 9 9 7650 50150


Type-II, For drifting sand soil 1 Nos. 9200 9200 9 9 1656 10856
Type-III, For Rocky areas 1 Nos. 9200 9200 9 9 1656 10856
Supply, Transportation and installation of new K.M. Marker as per DWG. No. GSPL-AMC-STD-09 including supply of all
materials for fabrication, cleaning, two coats of red-oxide and two coats of zebra color (black and golden yellow strips) of
approved quality (I S I Mark) paint and marking the number, direction, chainage and pipe size. Excavation upto required
size, grouting in 1:3:6 PCC mixture to correct line, level and direction, back-filling & restoration. The work is to be
346 executed as per drawing and direction E.I.C. No separate charges shall be paid for manpower, consumables, transportation,
lifting equipments, handling, tools & tackles used during execution of this activity.
Type-I, For normal soil 10 Nos. 8500 85000 9 9 15300 100300
Type-II, For drifting sand soil 1 Nos. 9200 9200 9 9 1656 10856
Type-III, For Rocky areas 1 Nos. 9200 9200 9 9 1656 10856

Supply, Transportation and installation of new OFC Marker as per DWG. No. GSPL-AMC-STD-05 including supply of
all materials for fabrication, cleaning, two coats of red-oxide and two coats of zebra color (black and golden yellow strips)
of approved quality (I S I Mark) paint and marking the number, direction, chainage and pipe size. Excavation upto required
size, grouting in 1:3:6 PCC mixture to correct line, level and direction, back-filling & restoration. The work is to be
347 executed as per drawing and direction E.I.C. No separate charges shall be paid for manpower, consumables, transportation,
lifting equipments, handling, tools & tackles used during execution of this activity.

Type-I, For normal soil 1 Nos. 8500 8500 9 9 1530 10030


Type-II, For drifting sand soil 1 Nos. 8500 8500 9 9 1530 10030
Type-III, For Rocky areas 1 Nos. 8500 8500 9 9 1530 10030

Supply, transportation and installation of pre-cast RCC (1:2:4) RoU boundary markers on pipeline RoU as per drawing No.-
DWG. No. GSPL-AMC-STD-04 or as per direction of E.I.C. The work also includes necessary excavation of pits, grouting
348 100 Nos. 140000 9 9 25200 165200
of post & restoration. No separate charges shall be paid for manpower, consumables, transportation to site location, tools &
tackles used during execution of this activity.
1400

Filling empty cement bags of 50 kg capacity (the bags to be used in good condition only) by using sand/cement mixture in
10: 1 ratio and stitching by using jute threads and placing in position in RoW as directed by engineer-in-charge /Site
349 500 Nos. 45000 9 9 8100 53100
Engineer. No separate charges shall be paid for manpower, consumables, transportation to site location, tools & tackles used
during execution of this activity.
90
Providing temporary supports to existing Instrument / Electrical panels/DG set/PRS/Valves and equipments etc with
350 1 Location 700 9 9 126 826
metallic scaffolding material / wooden sleepers or Jacks etc. 700
Cleaning of valve chamber / condensate pit including de-watering, cleaning of moisture content, sludge removal, cleaning
Per Chamber /
351 with fresh water, drying of cleaned valve chamber or condensate pit and disposal of sludge and debris within a lead of 1 1 500 9 9 90 590
PIT
KM. 500
Providing stone pitching average 230-250mm thickness with the joints filled up with cement mortar of 1:6. Including
preparation of the bed slope, cutting and filing earth, compacting to the 90% of proctor's density, filling the joints with 1:6
352 1 Sq. Mtr. 4500 9 9 810 5310
cement mortar pointing the joints with same mortar complete in all respects including the supply of stone boulders, all
materials, labour and consumables etc. as directed by engineer-in-charge and as per the specifications. 4500
Installation of fallen boundary stones / pipeline makers, the job includes supply of all materials required to complete the re-
353 installation works including excavation, fixing of boundary stone/pipeline marker on pipeline RoU in PCC 1:3:6 to correct 1 Nos. 1890 9 9 340.2 2230.2
line & level, restoration etc. Complete job as per specification and direction of E.I.C. 1890
Supply and installation of concertina Razor wire to replace the existing damage portion fencing of dia. 500mm of GI
barbed wire 12SWG in helical shape of wire to wire distance 250mm spacing in existing boundary wall with 8 nos(4 on
354 each side) horizontal wiring at 45 degree spacing each as described in drawing. 1 R. Mtr. 1650 9 9 297 1947
The 'Y' Steel Structure if used shall be claimed as per relevent SOR. New structure work includes sand blasting , primer and
2 coats of aluminium paint for structural work. 1650
Supply and installation of Barbed wire( 6 Wire) fencing to replace the existing damage portion mm of GI barbed wire
12SWG in existing boundary wall.
355 1 R. Mtr. 1650 9 9 297 1947
The Steel Structure if used shall be claimed as per relevent SOR. New structure work includes sand blasting , primer and 2
coats of aluminium paint for structural work and existing with single coal of aluminium painting 1650
356 Supply and installation of GI Chain link fencing with hole size of 50 mm 1 Sq. Mtr. 1000 1000 9 9 180 1180

Washout repair job on existing buried pipeline, which occur mostly during monsoon period: Supplying and filling selected
loose earth other than black cotton soil from borrowed pits
in the washout/depressed land or in the pit locations of pipeline ROW compacting up to 90% of proctor density and filling
in layers not exceeding 200 mm including cost of transportation, spreading, compacting, all as directed by engineer-in-
357 1 Cu. Mtr. 880 9 9 158.4 1038.4
charge. The rates includes royalty or any other levies by Govt. agencies towards taking of loose earth from borrowed area as
per the direction of engineer-in-charge
/site engineer inclusive all labour, materials, tools, tackles, transportation, taxes etc. completion all respect. (Payment shall
be made on basis of measurement of the pit profile of the earth washout in the ROW)
880
Supplying and laying in position of RCC NP3 class pipes with collars, confirming to IS: 458 for pipe culverts, cable
crossing, road crossing etc. including cutting the hume pipe if necessary, lowering, laying in position to proper levels, slopes
etc. caulking the joints with spun yarn soaked in neat cement slurry and finishing with cement mortar 1: 2 (1 Cement: 2
Sand) curing etc. all complete as per drawings / specifications and directions of Owner/Owner’s Representative. Rate is
included the cost of excavation up to 1.2-meter cover and backfilling of earth. Providing bedding concrete of PCC (1:4:8)
358 75 mm thick and backfilling with good earth

100 mm dia pipes 1 R. Mtr. 1200 1200 9 9 216 1416


300 mm dia pipes 1 R. Mtr. 2800 2800 9 9 504 3304
400 mm dia pipes 1 R. Mtr. 3400 3400 9 9 612 4012
500 mm dia pipes 1 R. Mtr. 4300 4300 9 9 774 5074
Monitoring of RoU and PSP by foot patrolling with the help of GPS based mobile application along the route of pipeline.
359 1 Km 500 9 9 90 590
GSPL will provide mobile with installed software. 500
360 Supply and Installation of 1" UPVC water pipeline in control room building / terminal at damaged locations 1 R. Mtr. 450 450 9 9 81 531
Supply & Replacement of Open Path gas Detector of GSPL approved make & model.with control card and full intregration
361 1 No. 22000 9 9 3960 25960
as per the given specification by EIC and as per GSPL requirement for Gas Detection System. 22000
362 Transportation of material up to 2 Tonnes from one location to another location
Tata 407 1 Km 100 100 9 9 18 118
Eicher 1 Km 150 150 9 9 27 177
Truck 1 Km 200 200 9 9 36 236
Total Amount (In Words): Six Crore twelve Lacs eighty seven thousands and eight hundred eighty Rs and Seventy six Paisa only
61287880.76
Note:
1. Bidders are required to visit station, mainline and associated facilities to make themshelves fully aware of the typical facilities of GSPL installation. Based on that bidder shall quote the price against each SOR item.

2. The description given under the items of work in Schedule of Rates shall be deemed to include, wherever applicable, mobilisation ,labour, equipments, materials and fixing in position of all materials and equipments, disposal of wastages, desludging and allied operations at any stage of the work and all other labours and operations
necessary whether specifically stated/implied or not, for the full and entire execution and completion of the relative works in all respects according to the contract. Cost of materials under the scope of Contractor’s supply & all other consumables/inputs required for carrying out the works & for permanent incorporation in the works for
which rates are quoted in the "Schedule of Rates" shall be inclusive of all duties, taxes (excluding GST), etc as applicable.

3. Based on the SOR price, the contracr shall be liable to execute each SOR items irrespective of rate change/escalations as per the requirement given by GSPL. In case contractor deny to execute any of the SOR item within the specified timeline given in the work request then the work shall be carried out by any other agency at the risk &
cost of engaged ARC contractor. Cost of the same shall be recovered from the ARC contractor either from RA Bills or from Performanace Bank Garuentee (PBG).
4. Without prejudice to any other right(s) the Owner reserves the right to change the frequency of work/ activities/ quantity appearing in the shedule of Rates without any clarification to the qualified bidder. GSPL shall also reserve a right to offload any particular line item/ actvity to any specilized agency/ vendor at any point of time and
ARC contractor shall not make any claim related to the offloaded/ deleted items.
5. The Quantities mentioned above are estimated for evaluation purpose. Payment shall be made based on Actual Quantity executed.
6. The quatity is indicative for entire grid. Actual award of work shall be done zonewise.
7. Bidder should strictly quote as per price bid format only.Any bid not conforming to the price bid formats shall be liable for rejection.
8. The bidder should quote for all the items.Incomplete price SoRs shall not be considered for evaluation.Scope mentioned to be read along with tender in totality.
9. GSPL reserves the right to reject any bid without any reason whatsoever
10. Bidder confirms that he has noted the contents of notes to the price schedule, bid document and quoted his prices accordingly without any deviation.
Final Revised ANNEXURE 2 : Schedule Of Rate (SOR) for ZONE-2
GSPL/PROC/2019/04/O/141 - ANNUAL RATE CONTRACT FOR MECHANICAL MAINTENANCE WORKS IN GSPL GAS GRID PIPELINE NETWORK

S P Construction
Category of Registration in GST(Tick whichever is applicable)
Un Registered
Registered (Normal)
Registered (Composition Levy)

Type of Supply Under this Contract (Tick whichever is applicable)


Normal Supply of goods and services
Mixed supply
Composite supply
Works Contract

Schedule of Rates

Sr No Description Goods/Services HSN (Eight Qty Unit of Measu- Total Basic Rate of GST
digit)/SAC (Six digit) Unit Rate Amount

rement SGST/UTGST CGST IGST CESS


A B C D E G=DXF H I J K
F

Surface preparation of installed(Operational) piping/spool/Fittings, Steel Structural surfaces by Britstle Blaster machine or
other proper methods(Paint\Rust remover equipment) with equipments, accessories, manpower, material etc upto required
surface finish.
The work also includes painting of piping spool including supply of paint and application of 2 coats of red-oxide primer or
1 high build chlorinated rubber/ Polyurethane / Zinc phosphate(as per site condition) of 70 micron each and 2 coats of high 1500 Sq. Mtr. 600000 9 9
build epoxy finished paint of golden/ cannery yellow/any applicable colour instructed by GSPL with 70 micron each of
approved quality including stenciling of line numbers, pipe tagging, flow direction arrow, other lettering as per P&ID/
instruction of GSPL EIC. This includes covering of nut-bolts using masking tape during surface preparation and painting
works.
400

Surface preparation of new piping/spool/Fittings, Steel Structural surfaces Britstle Blaster machine or blasting methods.
Finish of surface quality SA 2 ½ and roughness 60 microns minimum by providing shot/sand of approved quality, shot/sand
blasting equipments & its accessories, manpower, material etc.
The job also includes painting of piping spool including supply of paint and application of 2 coats of red-oxide primer or
2 high build chlorinated rubber/ Polyurethane / Zinc phosphate of 70 micron each and two coats of high build epoxy finished 200 Sq. Mtr. 38000 9 9
paint of golden/ cannery yellow/ any applicable colour instructed by GSPL with 70 micron each of approved quality
including stenciling of line numbers, pipe tagging, flow direction arrow, other lettering as found condition of pipeline as per
instruction of GSPL EIC. This includes covering of nut-bolts using masking tape, during surface preparation & painting
works.

190

Surface preparation of installed DG Canopy/ Panels with Britstle Blaster machine(Paint\Rust remover equipment)
equipments & its accessories, manpower, material etc upto required surface finish.
3 The job also includes spray painting of DG Canopy/ Panels including supply of paint and application of 1 coats of Epoxy 150 Sq. Mtr. 86250 9 9
paint(as per site condition) of 70 micron and two coats of Auto Paint(ASPA)/ PU Paint of 80 micron each of approved
quality including lettering as per instruction of GSPL EIC.
575
Supply and application of Stanvac make Chemcoint RL 500 (Anti Corrosive Coating cum primer) Stanvac make 727
Stangard HP-PLPU (Golden Yellow Top Coat over Chemcoint RL 500 for long lasting corrosion protection) paint in A/G
4 100 Sq. Mtr. 45000 9 9
station piping / valves / fittings / etc. This includes surface preparation, tools, tackels, consumables, transportation,
equipment, manpower, etc. required for execution of job. 450

Painting of Above Ground Civil Supports/Foundations/Earth Pits etc. (Existing/Newly Constructed) including Paint (Terra
5 2500 Sq. Mtr. 250000 9 9
cotta), equipments for application & its accessories, manpower, material etc upto required surface finish.
100
Complete job of repairing the leakage of existing buried pipeline by using leak repair clamps & other accessories related to
clamp. Clamp will be issued by GSPL at designated store. The activity shall include all necessary arrangements, excavation
Location
& backfilling work, material transportation and other works required for leak arrest and restoration of site. Land and corp
compansation will be in GSPL's scope.

2" 1 Location 3500 3500 9 9


4" 1 Location 3500 3500 9 9
6 6’’ 1 Location 3500 3500 9 9
8’’ 1 Location 3500 3500 9 9
10" 1 Location 3500 3500 9 9
12’’ 1 Location 5000 5000 9 9
16” 1 Location 5000 5000 9 9
18’’ 1 Location 5000 5000 9 9
24’’ 1 Location 5000 5000 9 9
30” 1 Location 7000 7000 9 9
36’’ 1 Location 7000 7000 9 9
Complete job of repairing the leakage of existing above ground pipeline by using leak repair clamps. Manpower,
equipments and material shifting to site shall be in scope of contractor. Clamps will be provided by GSPL. Restoration of Location
above ground piping as per original conditions.
2" 1 Location 500 500 9 9
3" 1 Location 500 500 9 9
4" 1 Location 500 500 9 9
6’’ 1 Location 1000 1000 9 9
7 8’’ 1 Location 1000 1000 9 9
10" 1 Location 1500 1500 9 9
12’’ 1 Location 1500 1500 9 9
16” 1 Location 2000 2000 9 9
18’’ 1 Location 2000 2000 9 9
24’’ 1 Location 2000 2000 9 9
30” 1 Location 2500 2500 9 9
36’’ 1 Location 2500 2500 9 9
42" 1 Location 2500 2500 9 9

Emergency repair of leaking underground pipe by replacement by Pipe spool, or fully encircled sleeve welded on pipe: This
work shall include transportation of Pipes and associated materials from store locations (within Gujarat), loading /
unloading of the line pipes to the site, hydrotest of pipes, excavating the trench for finding out the leakage in the existing
line burst portion of point(This excavation also includes the excavation for replacement of Pipe upto max. 12 meter),
dewatering and cleaning of pit or trench, and to make it free from fire/ accident etc., cutting the line from both ends (upto
Location
one pipe length item, approx 12 Mtr. or part thereof shall be treated as one job ) surface and bevel preparation DP checking
& welding the pipe of the required length on the line, NDT(Radiography,UT,DP) coat and wrap, Holiday testing and back-
filling the same etc. complete the work as directed by E.I.C. Contractor to arrange all necessary equipment, consumables,
manpower etc to complete the job.(Pipes shall be supplied free of cost by GSPL at designated Store)(Nitrogen purging for
the section if required to be claimed seaprately as per SOR.)

8
2" 1 Location 14000 14000 9 9
4" 1 Location 16000 16000 9 9
6’’ 1 Location 18000 18000 9 9
8’’ 1 Location 23000 23000 9 9
10" 1 Location 25000 25000 9 9
12’’ 1 Location 27000 27000 9 9
16” 1 Location 32000 32000 9 9
18’’ 1 Location 35000 35000 9 9
24’’ 1 Location 45000 45000 9 9
30” 1 Location 55000 55000 9 9
36’’ 1 Location 65000 65000 9 9
Repair of metal loss on pipeline at third party damage locations / corrosion / less thickness locations by composite sleeve
(Clock Spring). The job includes excavation & restoration , clearing of pit, dewatering, removal of coating, preparation the
pipe surface to put sleeve. The job also includes the supply of coating materials & repair of damaged coating, Holiday
Testing and, back filling with soft soil and final cleanup to restore the field to its original conditions. PAUT/UT for anomaly
assessment at damaged location before application of composite wrap shall be in the scope of contractor. Land and corp
compansation will be in GSPL's scope. It is considered that sleeve width will be 300 mm std.

2" 2 Location 38000 76000 9 9


9 4" 2 Location 78000 156000 9 9
6’’ 4 Location 88000 352000 9 9
8’’ 2 Location 108000 216000 9 9
10" 1 Location 118000 118000 9 9
12’’ 6 Location 138000 828000 9 9
16” 1 Location 148000 148000 9 9
18’’ 8 Location 168000 1344000 9 9
24’’ 12 Location 198000 2376000 9 9
30” 4 Location 208000 832000 9 9
36’’ 1 Location 218000 218000 9 9

Repair of Pipeline / Flange / RTD Thermowell/IJ/Valves Body at leakage portion or less thickness locations by supply and
application of Nicco - Fermanite clamp or any other leak clamp which can be installed on line and injecting sealing
material. The job includes cleaning of pipeline / flange / RTD Thermowell/IJ/Valves, installation of Nicco - Fermanite
clamp or any other leak clamp which can be installed on line and injecting sealing material on pipes of dia 2" / 4" / 6”/ 8” / Location
10"/ 12”. The job includes the painting of pipeline / flange / RTD Thermowell/IJ/Valves and restore the field to its original
conditions. The job includes man-power, transportation and other resources. This job shall be carried out by certified OEM /
vendor only.
10

upto 2’’ 8 Location 14000 112000 9 9


2" to 4’’ 2 Location 14000 28000 9 9
6’’ 8 Location 14000 112000 9 9
8’’ 6 Location 19000 114000 9 9
10’’ 4 Location 25000 100000 9 9
12’’ 4 Location 27000 108000 9 9
Peel-off test on existing buried pipeline to check the health of pipeline and corrosion on pipe surface. Job includes
excavation & backfilling of required size. After inspection, cleaning, coating repair, holiday check, back filling and final
cleanup. etc, as per drawing and direction of E.I.C. Survey is to be carried out on pipelines of dia. 6”, 8’’, 10", 12’’, 16", Location
11 18’’, 24’’, 30”,36" including man power, transporation, machinery, peel-off test equipment, temperature gun, etc.

Soft soil 8 Per Pit 8000 64000 9 9


Rocky area 4 Per Pit 10000 40000 9 9

Dismantling & removing the existing installed equipment such as DG Set, Metering skid, Filter, Filteration skid, PRS skid,
Pig Barrel, Pig Trolly, Jib Crane, Piping,electrical/ instrumentation panel, valves, structural steel etc. carefully including
handling, loosing the nuts, bolt cutting etc(if required) and stacking the equipments/ material within a radius of 250 Mts.
and as directed by EIC.
Manpower, Machinery required, transportation is in contractor's scope.

12 Item weight upto 50 kg 100 Lumsum 1500 150000 9 9


Item weight upto 51-150 kg 70 Lumsum 4000 280000 9 9
Item weight upto 151-250 kg 40 Lumsum 6500 260000 9 9
Item weight upto 251-500 kg 20 Lumsum 12000 240000 9 9
Item weight upto 501-1000 kg 10 Lumsum 14000 140000 9 9
Item weight upto 1 Ton - 2 Tonnes 10 Lumsum 15000 150000 9 9
Item weight upto 2-Tonnes- 3 Tonnes 5 Lumsum 15500 77500 9 9
Installation of equipment such as DG Set, Metering skid, Filter, Filteration skid, PRS skid, Pig Barrel, Pig Trolly, Jib Crane,
Piping,electrical/ instrumentation panel, valves, structural steel etc. carefully including handling, erection and proper
installtion of the equipments/ material within a radius of 250 Mts. and as directed by EIC.
Manpower, Machinery required, transportation is in contractor's scope.
Item weight upto 50 kg 100 Lumsum 1500 150000 9 9
13 Item weight upto 51-150 kg 70 Lumsum 4000 280000 9 9
Item weight upto 151-250 kg 40 Lumsum 6500 260000 9 9
Item weight upto 251-500 kg 20 Lumsum 12000 240000 9 9
Item weight upto 501-1000 kg 10 Lumsum 14000 140000 9 9
Item weight upto 1 Ton - 2 Tonnes 10 Lumsum 15000 150000 9 9
Item weight upto 2-Tonnes- 3 Tonnes 5 Lumsum 15500 77500 9 9
Installation of above ground valves(Ball/Glove/ Check) of various sizes in piping system including handling, blind removal
providing temporary supports if necessary, Studs bolt loosening / tightening, gasket insertion and torque setting with all
tools/tackles/manpower etc. of valves sizes, Hydra and other lifting equipment inclusive of scaffolding arrangement at site if
required including valve operation. Gasket shall be provided by GSPL.
Up to & including 1” NB 40 Nos. 475 19000 9 9
1 ½” to 2’’ NB 50 Nos. 475 23750 9 9
3”NB 6 Nos. 750 4500 9 9
4’’NB 6 Nos. 1250 7500 9 9
14 6’’NB 4 Nos. 5000 20000 9 9
8’’NB 5 Nos. 5500 27500 9 9
10"NB 1 Nos. 5800 5800 9 9
12’’NB 3 Nos. 6300 18900 9 9
16”NB 1 Nos. 6400 6400 9 9
18’’NB 1 Nos. 6800 6800 9 9
24’’NB 1 Nos. 8800 8800 9 9
30’’NB 1 Nos. 8800 8800 9 9
36’’NB 1 Nos. 8800 8800 9 9
Dismantling of valves(Ball/Globe/Check) from the line and putting blinds / spool pieces etc., for various pipe sizes etc.
including Stud bolt loosening, gasket changing, handling with all tools / tackles / manpower etc. of valves sizes. Gasket
shall be provided by GSPL.
Up to & including 1” NB 10 Nos. 475 4750 9 9
1 ½” to 2’’ NB 30 Nos. 475 14250 9 9
3’’ NB 4 Nos. 1200 4800 9 9
4’’ NB 4 Nos. 3000 12000 9 9
6’’ NB 10 Nos. 4000 40000 9 9
15
8’’ NB 6 Nos. 4800 28800 9 9
10" NB 1 Nos. 5200 5200 9 9
12’’ NB 4 Nos. 5600 22400 9 9
16” NB 1 Nos. 5800 5800 9 9
18’’ NB 2 Nos. 6330 12660 9 9
24’’ NB 2 Nos. 8800 17600 9 9
30’’ NB 1 Nos. 9000 9000 9 9
36’’ NB 1 Nos. 9000 9000 9 9
Dismantling or Instllation of Blind Flanges from A/G piping for various pipe sizes including nut bolt removing & handling
with all tools / tackles / manpower/machinery & consumables etc. and stacking all within radius of 250 Mts as per GSPL
EIC instructions.
upto 2’’ 20 Nos. 300 6000 9 9
16
From 3" to 6" 6 Nos. 500 3000 9 9
From 8" to 12" 5 Nos. 2000 10000 9 9
From 16" to 24" 1 Nos. 5000 5000 9 9
From 30" to 36" 1 Nos. 6000 6000 9 9
Reversal of Spectacle Blind on installed A/G Piping for various sizes etc. including nut bolt loosening, gasket changing with
all tools / tackles / manpower etc. of valves sizes:-
Up to & including 1” NB 2 Nos. 200 400 9 9
1 ½” to 2’’ NB 6 Nos. 200 1200 9 9
3’’ NB 4 Nos. 300 1200 9 9
4’’ NB 6 Nos. 300 1800 9 9
6’’ NB 10 Nos. 500 5000 9 9
17 8’’ NB 10 Nos. 500 5000 9 9
10" NB 2 Nos. 1000 2000 9 9
12’’ NB 8 Nos. 1200 9600 9 9
16” NB 1 Nos. 5000 5000 9 9
18’’ NB 12 Nos. 5000 60000 9 9
24’’ NB 20 Nos. 5500 110000 9 9
30’’ NB 12 Nos. 7500 90000 9 9
36’’ NB 1 Nos. 7500 7500 9 9
Gas cutting, grinding and bevelling of various diameter station pipes of Sch-80 (Sch-160 upto 2" pipe). The job inclusive of
all manpower, transportation, consumables, equipments, tools etc.
upto 3’’ 30 Inch. Dia. 400 12000 9 9
From 4" to 6" 10 Inch. Dia. 400 4000 9 9
18
From 8" to 10" 4 Inch. Dia. 400 1600 9 9
18
From 12" to 16" 40 Inch. Dia. 400 16000 9 9
From 18" to 24" 1 Inch. Dia. 500 500 9 9
From 30" to 36" 1 Inch. Dia. 500 500 9 9

Fabrication and installation of Underground Casing Pipes IS-3589:2001 Fe-410/or IS2062 equivalent grade of different
thickness or schedule. Job Includes transportation of free issue casing Pipe from GSPL designated store to site, handling,
Horizontal Cutting at both sides of Casing Pipes as well as Circumferencial Cutting of Casing Pipes, beveling /edge
preparation of Longitudnal direction & Circumferencial Direction, aligning, installation of Casing Insulators, Sand Filling,
Mud Application, fit-up, tie-in, welding at both sides of pipes in longitudnal direction as well as Circumferencial Joints, DP,
temporary supporting etc. Bentonite Filling, Dewatering, installation of end seals & Painting of Casing Pipe. Excavation
upto required depth & Back-filling of the same after successful completion is also included in the scope. All the tool &
tackels, equipments, hydra, mud pump and supply & installation of required size casing insulator, vent & drain pipes of
suitable size shall be included in this SOR. (Supply of Casing Pipes are in scope of GSPL & will be issued at designated
GSPL stores). Pemission for excavation and Land / Corp compansation shall be in scope of GSPL.

Casing Size 12" Dia. (Normal Soil) 1 R. Mtr. 8000 8000 9 9


19 Casing Size 12" Dia. (Rocky Soil) 1 R. Mtr. 8400 8400 9 9
Casing Size 16" Dia.(Normal Soil) 1 R. Mtr. 9000 9000 9 9
Casing Size 16" Dia. (Rocky Soil) 1 R. Mtr. 9400 9400 9 9
Casing Size 18" Dia. (Normal Soil) 1 R. Mtr. 10000 10000 9 9
Casing Size 18" Dia. (Rocky Soil) 1 R. Mtr. 10400 10400 9 9
Casing Size 20" Dia. (Normal Soil) 1 R. Mtr. 11000 11000 9 9
Casing Size 20" Dia. (Rocky Soil) 1 R. Mtr. 11500 11500 9 9
Casing Size 24" Dia. (Normal Soil) 1 R. Mtr. 13000 13000 9 9
Casing Size 24" Dia. (Rocky Soil) 1 R. Mtr. 13500 13500 9 9
Casing Size 30" Dia. (Normal Soil) 1 R. Mtr. 14000 14000 9 9
Casing Size 30" Dia. (Rocky Soil) 1 R. Mtr. 14500 14500 9 9
Casing Size 36" Dia. (Normal Soil) 1 R. Mtr. 15000 15000 9 9
Casing Size 36" Dia. (Rocky Soil) 1 R. Mtr. 15500 15500 9 9
Casing Size 42" Dia. (Normal Soil) 1 R. Mtr. 16000 16000 9 9
Casing Size 42" Dia. (Rocky Soil) 1 R. Mtr. 16500 16500 9 9

Dismantling / Revomal of existing Underground Casing Pipes installed on Existing Operational Pipelines.
Job Includes excavation of the earth work upto existing pipeline/casing pipe, removal of End seals, Horizontal Cutting at
both sides of Casing Pipes as well as Circumferencial Cutting of Casing Pipes, removal of Casing Insulators, removal of
Mud,removal of bentonite/mud and disposal of the same at suitable place as per GPCB/CPCB norms, use of water jet for
cleaning the carier pipe, cutting of drain & vent pipes, transportation of removed Casing Pipes to GSPL store/designated
location, Dewatering if required, holiday testing, repair of damaged coating, holiday testing after repair, Back-filling &
restoration of the same after successful completion of job.

Casing Size 12" Dia. (Normal Soil) 1 R. Mtr. 6000 6000 9 9


Casing Size 12" Dia. (Rocky Soil) 1 R. Mtr. 6200 6200 9 9
Casing Size 16" Dia.(Normal Soil) 1 R. Mtr. 6500 6500 9 9
20
Casing Size 16" Dia. (Rocky Soil) 1 R. Mtr. 6700 6700 9 9
Casing Size 18" Dia. (Normal Soil) 1 R. Mtr. 7000 7000 9 9
Casing Size 18" Dia. (Rocky Soil) 1 R. Mtr. 7200 7200 9 9
Casing Size 20" Dia. (Normal Soil) 1 R. Mtr. 7300 7300 9 9
Casing Size 20" Dia. (Rocky Soil) 1 R. Mtr. 7500 7500 9 9
Casing Size 24" Dia. (Normal Soil) 1 R. Mtr. 7500 7500 9 9
Casing Size 24" Dia. (Rocky Soil) 1 R. Mtr. 7700 7700 9 9
Casing Size 30" Dia. (Normal Soil) 1 R. Mtr. 7800 7800 9 9
Casing Size 30" Dia. (Rocky Soil) 1 R. Mtr. 8000 8000 9 9
Casing Size 36" Dia. (Normal Soil) 1 R. Mtr. 8000 8000 9 9
Casing Size 36" Dia. (Rocky Soil) 1 R. Mtr. 8200 8200 9 9
Casing Size 42" Dia. (Normal Soil) 1 R. Mtr. 8500 8500 9 9
Casing Size 42" Dia. (Rocky Soil) 1 R. Mtr. 8800 8800 9 9
Removal of gear box from Valve((Ball/Globe/Check), dismantling of Gear box, replacement of required packing, proper
cleaning, greasing of the same with Multipurpose grease & re-installation of gear box for various Valve sizes including
supply of multipurpose grease, handling, packing materials, nut bolt loosening, gasket changing with all tools / tackles /
manpower etc. of different valves sizes .

21
4’’ NB 20 Nos. 1000 20000 9 9
21
6’’ NB 10 Nos. 1200 12000 9 9
8’’ NB 10 Nos. 1300 13000 9 9
10" NB 2 Nos. 1600 3200 9 9
12’’ NB 2 Nos. 1800 3600 9 9
16” NB 1 Nos. 2000 2000 9 9

Online servicing of gear box by cleaning of the housing, filiing with MP Grease. Sevicing of the Stem & Spindle of the
Globe Valve by cleaning with emery Paper & application of multi purpose Graese.

4’’ NB 1 Nos. 1000 1000 9 9


22 6’’ NB 1 Nos. 1200 1200 9 9
8’’ NB 1 Nos. 1300 1300 9 9
10" NB 1 Nos. 1600 1600 9 9
12’’ NB 1 Nos. 1800 1800 9 9
16” NB 1 Nos. 2000 2000 9 9
Dismantling of piping spool along with flanges from line for various pipe sizes and putting blind including nut bolt
removing & handling with all tools / tackles / manpower/machinery etc and stacking all within radius of 250Mts as per
GSPL EIC instructions.(No separate charges shall be paid extra for manpower & equipments used)
Up to 2’’ NB 50 R. Mtr. 480 24000 9 9
3’’ NB 6 R. Mtr. 580 3480 9 9
4’’ NB 20 R. Mtr. 780 15600 9 9
6’’ NB 20 R. Mtr. 900 18000 9 9
23
8’’ NB 15 R. Mtr. 1100 16500 9 9
10" NB 30 R. Mtr. 1300 39000 9 9
12’’ NB 25 R. Mtr. 1400 35000 9 9
18’’ NB 1 R. Mtr. 2200 2200 9 9
24’’ NB 1 R. Mtr. 2200 2200 9 9
30" NB 1 R. Mtr. 2500 2500 9 9
36’’NB 1 R. Mtr. 2500 2500 9 9
Installation of piping spool along with flanges for various pipe sizes including blind removal, nut bolt removing & handling
with all tools / tackles / manpower/ machinery etc as per GSPL EIC instructions.(No separate charges shall be paid extra for
manpower & equipments used)
up to 2’’ NB 80 R. Mtr. 480 38400 9 9
3’’ NB 10 R. Mtr. 580 5800 9 9
4’’ NB 10 R. Mtr. 780 7800 9 9
6’’ NB 40 R. Mtr. 780 31200 9 9
24
8’’ NB 15 R. Mtr. 950 14250 9 9
10" NB 6 R. Mtr. 1180 7080 9 9
12’’ NB 20 R. Mtr. 1280 25600 9 9
18’’ NB 1 R. Mtr. 2200 2200 9 9
24’’ NB 1 R. Mtr. 2200 2200 9 9
30" NB 1 R. Mtr. 2500 2500 9 9
36’’NB 1 R. Mtr. 2500 2500 9 9
Gas cutting, grinding and welding of edges of chequered plate installed in cable trenches, valve pit etc. including handling.
25 20 R. Mtr. 6000 9 9
The job inclusive of all consumables, equipments, tools, labour etc. 300
Supply and Installation of chequered plate of required size for trenches, platforms etc including application of red oxide
primer and two coats of finish paint of approved quality.(No separate charges shall be paid for gas cutting, grinding &
welding of edges of chequered palte & transportation of the same) The job inclusive of all consumables, equipments, tools,
26 labour etc.
4 mm thick 10 Sq. Mtr. 4000 40000 9 9
6 mm thick 4 Sq. Mtr. 6000 24000 9 9
8 mm thick 4 Sq. Mtr. 7000 28000 9 9
Providing and fixing pre coated galvanized G.I. Sheet of approved colour on roofing and sides of Metering system or DG
Sets as per manufacturer’s instructions including providing sealant in the overlapping portion of sheets complete and
27 including all accessories.
0.6 mm thick trapezoidal profile 80 Sq. Mtr. 680 54400 9 9
0.6 mm thick corrugated profile 150 Sq. Mtr. 680 102000 9 9
Providing & fixing hand railing with Class-B pipes on equipments like filter, PRS, operating platforms, buildings etc. The
28 job includes surface cleaning, supply and application of two coats of red oxide primer and two coats of finish paint of 100 Mtr. 63500 9 9
approved quality. The job is to be executed as per the direction of the E.I.C. 635
Replacement by removing old gaskets including tightening and loosing of Flanges with all tools / tackles / manpower/
machinery etc as per GSPL EIC instructions.
Gasket shall be provided by GSPL at designated store.
up to 2’’ NB 80 Nos. 300 24000 9 9
3’’ NB 10 Nos. 300 3000 9 9
4’’ NB 4 Nos. 300 1200 9 9
6’’ NB 5 Nos. 500 2500 9 9
29 8’’ NB 2 Nos. 500 1000 9 9
10" NB 2 Nos. 550 1100 9 9
12’’ NB 10 Nos. 650 6500 9 9
16’’ NB 2 Nos. 1000 2000 9 9
18’’ NB 1 Nos. 1100 1100 9 9
24’’ NB 4 Nos. 1200 4800 9 9
30" NB 1 Nos. 1200 1200 9 9
36’’NB 1 Nos. 1200 1200 9 9
Maintenance of Filter: Valve Operations, Opening of filters, cleaning of filter elements/re-placement of the filter elements
and box-up. The job is including valve operation for filter isolation & Venting, nitrogen purging and the air-blowing of filter
element with compressed air, drying them in open yard for 3 hours, reinstall them if required change with new elements as
per instruction of GSPL EIC. Activity Inclusive of the Nitrogen purging with max. 7 M3 by using certified N2 Pressure
Regulator from Cylinder. The job inclusive of all consumables, equipments, tools, Manpower, transportation of filter
elements from designated store.
Size upto 8" QOEC Type 50 Nos. 5000 250000 9 9
Size upto 8" Flanged Door Type 10 Nos. 5500 55000 9 9
Size from 10" to 12" QOEC Type 50 Nos. 5500 275000 9 9
Size from 10" to 12" Flanged Door Type 10 Nos. 6000 60000 9 9
30
Size from 14" to 18" QOEC Type 10 Nos. 8000 80000 9 9
Size from 14" to 18" Flanged Door Type 2 Nos. 8500 17000 9 9
24" QOEC Type 10 Nos. 10000 100000 9 9
24" Flanged Door Type 2 Nos. 10000 20000 9 9
28" QOEC Type 2 Nos. 10000 20000 9 9
28" Flanged Door Type 1 Nos. 10000 10000 9 9
Size 28" to 50" QOEC Type 5 Nos. 11000 55000 9 9
Size 28" to50" Flanged Door Type 2 Nos. 11000 22000 9 9
Size 52" to 70" QOEC Type 2 Nos. 12000 24000 9 9
Size 52" to 70" Flanged Door Type 1 Nos. 12000 12000 9 9
Maintenance of Pig launcher/ receiver: Opening, cleaning and box-up of pig launcher / receiver of below sizes, including
cleaning & replacement of "O" ring if required. Job includes supply & purging of N2.The job is including valve operation
for Isolation & venting.
31
Size upto 18" 16 Nos. 9000 144000 9 9
Size from 20" to 36" 12 Nos. 10000 120000 9 9
Size from 40" & above 1 Nos. 15000 15000 9 9
Welding and laying of under ground pipeline up to 150 meters (with cover of 1.5 meters) with all manpower, machinary,
consumables, NDT, Coating, Restoration, Hydro Testing, Swabbing, Drying, N2 purging, Commissioning and related
documentation and As-Built drawings
2”NB 1 R. Mtr. 3500 3500 9 9
4”NB 1 R. Mtr. 4500 4500 9 9
6” NB 1 R. Mtr. 5000 5000 9 9
32 8” NB 1 R. Mtr. 5500 5500 9 9
12” NB 1 R. Mtr. 6000 6000 9 9
16” NB 1 R. Mtr. 7000 7000 9 9
18” NB 1 R. Mtr. 8000 8000 9 9
24” NB 1 R. Mtr. 10000 10000 9 9
30” NB 1 R. Mtr. 12000 12000 9 9
36” NB 1 R. Mtr. 14000 14000 9 9

Fabrication and installation of Above ground piping of grade ASTM A333 Gr.6 / API 5L/X65 & equivalent grade of
different schedule including, handling, aligning, cutting, beveling /edge preparation, installation of associated fittings /
flanges, fit-up, tie-in, welding, Radiography ,UT, DP, transportation of fabricated spool to location, temporary supporting,
erection of different size of fabricated aboveground piping at all elevations including handling, temporary supporting etc.
The job includes carrying out hydrostatic testing as per GSPL approved procedure of completed Piping loop / Piping system
as approved by Owner / Owner’s Representative to the specified pressures, providing all testing equipments / instruments /
accessories, blind etc. including Pressure recorder, Temperature probe, Temperature recorder. Dewatering, surface
preparation & painting of Spool after successful completion of hydro testing is also including in scope. (Pipe/ pipefittings
shall be issued by GSPL at designated store.)

Pipe Wall thickness ranging upto 6.4 mm 200 Inch. Dia. 1300 260000 9 9
Pipe Wall thickness ranging from 6.4 mm– 8.56 mm 250 Inch. Dia. 1600 400000 9 9
Pipe Wall thickness ranging from 8.57 mm– 17.4 mm 500 Inch. Dia. 2100 1050000 9 9

33
Pipe Wall thickness ranging from 17.5 mm– 32 mm 150 Inch. Dia. 2300 345000 9 9
PQR laboratory charges for 2” WPS 1 Nos. 2540 2540 9 9
33 PQR laboratory charges for 4” WPS 1 Nos. 3810 3810 9 9
PQR laboratory charges for 8” WPS 1 Nos. 6350 6350 9 9
PQR laboratory charges for 12” WPS 1 Nos. 9500 9500 9 9
PQR laboratory charges for 18” WPS 1 Nos. 10500 10500 9 9
EQT for 24 MM MS plate (SMAW) 1 Nos. 6350 6350 9 9
EQT for 24 MM MS plate (GTAW) 1 Nos. 7000 7000 9 9
EQT for 16 MM MS plate (SMAW) 1 Nos. 6500 6500 9 9
EQT for 16 MM MS plate (GTAW) 1 Nos. 6500 6500 9 9
NDT charges for 2” WPS 1 Nos. 500 500 9 9
NDT charges for 4” WPS 1 Nos. 650 650 9 9
NDT charges for 8” WPS 1 Nos. 750 750 9 9
NDT charges for 12” WPS 1 Nos. 900 900 9 9
NDT charges for 18” WPS 1 Nos. 1100 1100 9 9
NDT charges for EQT (24 MM plate) 1 Nos. 900 900 9 9
NDT charges for EQT (16 MM plate 1 Nos. 900 900 9 9

Supply and application for field joint coating of field weld joints of different size as mentioned below, with HEAT
SHRINKABLE Sleeves / DENSO MAKE/R-95 EPOXY tape at all the weld Joints for underground pipeline as per the
Owner’s specification. The job includes the preparation of trenches for joint coating, surface preparation by mechanical
cleaning through power brush, edge preparation, pre-heating of surface, primer application, wrapping of sleeve/tape,
holiday test etc. The supply of all consumables, utilities, equipment, and all manpower required, pipe cleaning and surface
preparation and testing including all handling, transportation, etc. included in this schedule of item.
34
DENSO/RayChem Make tape 30 Sq. Mtr. 4500 135000 9 9
R-95 EPOXY 20 Litres 6000 120000 9 9
Coating Repair PERP HTLP 80 6 Sq. Mtr. 7500 45000 9 9
coating repair filling material Mastic 4 Sq. Mtr. 2500 10000 9 9
HEAT SHRINKABLE Sleeve upto 8" dia 1 Sq. Mtr. 2500 2500 9 9
HEAT SHRINKABLE Sleeve from 10" to 18" dia 1 Sq. Mtr. 3400 3400 9 9
HEAT SHRINKABLE Sleeve from 24" to 36" dia 1 Sq. Mtr. 3500 3500 9 9

Re-conditioning of coating of underground gas pipeline after “locating the pipeline (in the scope of the contractor)” by
suitable method (Pipeline Locator / trial pit method / Pipeline markers etc) as per the coating fault. The activity includes (a)
Excavation to expose the line to suitable depth to expose the pipeline and provide working space around the pipeline.
(b)Removal of existing coating by using scrappers etc. and cleaning the surface to fine finishes by power brush / suitable
method.(c) Rectification of Coating of the defects by HEAT SHRINKABLE /DENSO MAKE after surface preparation by
mechanical cleaning, primer application, wrapping of tape, edge preparation, holiday test etc.(d)Back filling the trenches
and restoring the fields to the satisfaction of GSPL. Cleaning ROU of any debris etc.(e) The supply of all consumables,
35 utilities, equipment, and all manpower required, pipe cleaning and surface preparation, repairing of coating defects
(resulting in holiday in coating) and testing including all handling, transportation, etc. included in this schedule of item.
(f)any crop compensation to the land owner / farmers shall be in the scope of GSPL. (No separate charges shall be paid for
manpower, consumables, equipments, tools used for this activity)

DENSO / RayChem MAKE TAPE 100 Sq. Mtr. 4800 480000 9 9


HEAT SHRINKABLE Sleeve 6 Sq. Mtr. 5000 30000 9 9
COATING REPAIR PERP HTLP 80 8 Sq. Mtr. 6600 52800 9 9
COATING REPAIR FILLING MATERIAL MASTIC 6 Sq. Mtr. 2500 15000 9 9
Condition Checking of underground sectionalizing Valves including it's by-pass valves and associated underground piping.
The job includes
a) Removal of gravels, Excavation( (Removal of gravel from Process Area, Manual Excavation) and making trench of
appropriate size, required for checking of valves and under ground piping. Excavation to be carried out segragating sand,
gravel, mud, PVC so that backfilling can be done appropriately. Thickness measurement of valve body as well as
underground piping,
b) Reconditioning of coating using R-95 Epoxy or equivalent coating to be claimed as per relevant SOR (Supply &
Application).
c) Holiday test for the valve body and underground piping
d) Backfilling & restoration as found condition,
e) This include removal and re-installation of PT/TT/PGD stand, if required.
36 f) The supply of all consumables, utilities, equipment, and all manpower required, valve cleaning and surface preparation,
repairing of coating defects (resulting in holiday in coating) and testing including all handling, transportation, etc. included
in this schedule of item. This includes Supply & replacement of Polythelene sheet (sheet 0.5 mm thk) during the course of
valve checking.

12’’ NB 1 Nos. 8000 8000 9 9


16’’ NB 1 Nos. 8500 8500 9 9
18’’ NB 1 Nos. 8500 8500 9 9
24’’ NB 1 Nos. 8500 8500 9 9
30" NB 1 Nos. 8500 8500 9 9
36’’ NB 1 Nos. 8500 8500 9 9

Condition Checking of underground Tap-off Valves including it's by-pass/equilizing valves and associated underground
piping. The job includes
a) Removal of gravels, Excavation and making trench of appropriate size, required for checking of valves and under ground
piping. Thickness measurement of valve body as well as underground piping,
b) Reconditioning of coating using R-95 Epoxy or equivalent coating to be claimed as per relevant SOR (Supply &
Application).
c) Holiday test for the valve body and underground piping
d) Backfilling & restoration as found condition,
e) The supply of all consumables, utilities, equipment, and all manpower required, valve cleaning and surface preparation,
37 and testing including all handling, transportation, etc. included in this schedule of item. This SOR also includes Supply &
replacement of Polythelene sheet (sheet 0.5 mm thk) during the course of valve checking.

6’’ NB 1 Nos. 12000 12000 9 9


8’’ NB 1 Nos. 12000 12000 9 9
10’’ NB 1 Nos. 12000 12000 9 9
12’’ NB 1 Nos. 12000 12000 9 9
18" NB 1 Nos. 12000 12000 9 9
24" NB 1 Nos. 12000 12000 9 9
36’’ NB 1 Nos. 12000 12000 9 9
Supply and lay of Polythene sheet for process area. This includes removal of gravel & sieving & backfilling the same gravel
38 100 Sq. Mtr. 25000 9 9
after laying of Polythelene sheet of 0.5 mm thick 250

Checking of above ground pipeline supports by lifting the pipe section, providing temporary supports by standard
Engineering practises and rectification measures like application of paint to be carried out and fibre sheet of proper
dimension shall be placed. Any rectification in support shall be paid as per the relevant SOR. (Measurement shall be done
on the basis of Dia of Pipeline and Nos. of Support to be checked) No separate charges shall be paid for Manpower, Tools &
Tackles, consumbles used for this activities.

2”NB 4 Per support 500 2000 9 9


3”NB 6 Per support 700 4200 9 9
39 4”NB 6 Per support 900 5400 9 9
6” NB 6 Per support 1200 7200 9 9
8” NB 4 Per support 1800 7200 9 9
10” NB 8 Per support 2000 16000 9 9
12” NB 6 Per support 2000 12000 9 9
16” NB 1 Per support 2000 2000 9 9
18” NB 2 Per support 2200 4400 9 9
24” NB 1 Per support 2500 2500 9 9
30” NB 4 Per support 2500 10000 9 9
36” NB 1 Per support 2500 2500 9 9
Dismantling and taking out of submersible pump-motor of rating 3KW / 5 KW from bore well, retaining and rolling of
power cable pulled out from bore well. And reinstallation of repaired motor and associated assembly back into the bore in
complete working condition. The rate for repairing of damages in the system shall be paid as per list below. All the tools
tackles, manpower, tripod, fasteners etc. required for the job is included in the scope.
Rewinding 1 Nos. 4500 4500 9 9
a) 3 KW 6 Nos. 7000 42000 9 9
B) above 3KW to 5 KW 3 Nos. 8000 24000 9 9
above 5KW to 15 KW 1 Nos. 10000 10000 9 9
40
Rectificaiton/Replacement of mechanical damage of pump 3 Nos. 8000 24000 9 9
Flat strip cable 100 Mtr. 180 18000 9 9
Supply and installation of Casing PVC pipe of required diameter
a) 6" 30 Mtr. 450 13500 9 9
b) 8" 4 Mtr. 490 1960 9 9
Supply and Installation of Pump Pipe UPVC of required diameter
a) 1" 100 Mtr. 380 38000 9 9
b) 2" 50 Mtr. 390 19500 9 9

Providing & drilling the Bore well by means of mechanically suitable method prescribed in IS: 2800 (Part-I) of required dia,
having minimum depth of 50 Mtr. below clear water level at the location approved by Client/ Consultant, including all the
necessary labor, PVC casing confirm to IS: 12818, paddle flanges. waste, debris from/due to bore well to be removed &
41 make good upon completion of the works. Work includes but not limited to Gravel packing of suitable size, Mud pit
arrangement.

a) borehole including 6" dia PVC casing 1 Mtr. 830 830 9 9


b) borehole including 8" dia PVC casing 1 Mtr. 850 850 9 9
Providing & drilling the Bore well by means of mechanically suitable method prescribed in IS: 2800 (Part-I) of required dia,
having minimum depth of beyond 50 Mtr. below clear water level at the location approved by Client/ Consultant, including
all the necessary labor, PVC casing confirm to IS: 12818, paddle flanges. waste, debris from/due to bore well to be removed
42 & make good upon completion of the works. Work includes but not limited to Gravel packing of suitable size, Mud pit
arrangement.
a) borehole including 6" dia PVC casing 1 Mtr. 830 830 9 9
b) borehole including 8" dia PVC casing 1 Mtr. 850 850 9 9
Supply and installation of Submerible Pump with motor assembly of Approved Make as per the GSPL Vendor list attached
with this tender (KSB, Lubi,or equivalent make)
a) 1.5 HP 4 Nos. 14000 56000 9 9
b) 3 HP 4 Nos. 15500 62000 9 9
43
c) 5 HP 1 Nos. 25000 25000 9 9
d) 7.5 HP 1 Nos. 40000 40000 9 9
e) 10 HP 1 Nos. 45000 45000 9 9
f) 12 HP 1 Nos. 52000 52000 9 9
44 Supply & replacement of starting capacitor for 1-phase submersible pump set ( 250 mfd) 1 Nos. 400 400 9 9
Supply & Installation of Bore-well Starter Single-Phase (upto 3Kw)
45 2 Nos. 9000 9 9
Starter should be with in buit over load tripping feature. 4500
Supply & Installation of Bore-well Starter Three-Phase
Starter should be with in buit over load tripping feature.
46
up to 3 Kw 1 Nos. 6000 6000 9 9
4 Kw to 5 Kw 1 Nos. 6500 6500 9 9
Greasing of valves of size mentioned below with high pressure Grease/ pneumatic Sealant Gun under the supervision of
GSPL operator including Supply of manpower, nitrogen cylinder/air compressor, cotton waste for operation of pneumatic
gun. (Grease/Sealant and Grease Gun/pneumatic sealant gun will be supplied by GSPL) No separate charges shall be paid
for Manpower, Tools & Tackles, operation of valve for this activitiy.
6” NB 1 Nos. 800 800 9 9
8” NB 1 Nos. 800 800 9 9
47 10” NB 1 Nos. 800 800 9 9
12” NB 1 Nos. 800 800 9 9
16” NB 1 Nos. 900 900 9 9
18” NB 1 Nos. 970 970 9 9
24” NB 1 Nos. 1120 1120 9 9
30” NB 1 Nos. 1180 1180 9 9
36” NB 1 Nos. 1190 1190 9 9
Operation check of Manual/Gear/ Hydraulic operated Valves/ GOOV by manual opening and closing in presence and as per
instruction of GSPL supervisor - as per size given below (Including Consumables like Grease, Cotton Waste, etc.) No
separate charges shall be paid for Manpower, Tools & Tackles, consumbles used for this activities.
1/2" to 2”NB 1500 Nos. 250 375000 9 9
3”NB 50 Nos. 275 13750 9 9
4”NB 220 Nos. 350 77000 9 9
6” NB 250 Nos. 400 100000 9 9
48 8” NB 250 Nos. 450 112500 9 9
10” NB 50 Nos. 500 25000 9 9
12” NB 120 Nos. 525 63000 9 9
16” NB 2 Nos. 550 1100 9 9
18” NB 80 Nos. 575 46000 9 9
24” NB 30 Nos. 600 18000 9 9
30” NB 10 Nos. 600 6000 9 9
36” NB 1 Nos. 750 750 9 9
Painting of Valves (Ball,Globe & Check) of different sizes with two coats of finished paint of epoxy paint of suitable colour
of approved make as per the GSPL Vendor list attached with this tender to give an even shade after proper scraping of
existing paint by power brushing or suitable method and clearing of surface free from foreign materials as per the
instructions of GSPL EIC.
1/2" to 1”NB 50 Nos. 200 10000 9 9
2”NB 80 Nos. 250 20000 9 9
3”NB 8 Nos. 300 2400 9 9
4”NB 15 Nos. 350 5250 9 9
49 6” NB 15 Nos. 350 5250 9 9
8” NB 10 Nos. 350 3500 9 9
10” NB 8 Nos. 500 4000 9 9
12” NB 8 Nos. 600 4800 9 9
16” NB 1 Nos. 1000 1000 9 9
18” NB 4 Nos. 1500 6000 9 9
24” NB 6 Nos. 1500 9000 9 9
30” NB 1 Nos. 1500 1500 9 9
36” NB 1 Nos. 1500 1500 9 9
Painting of Actuators (excluding SS and Panel Part) installed on different sizes of valves with two coats of finished paint of
epoxy paint of suitable colour of approved make as per the GSPL Vendor list attached with this tender to give an even shade
after proper scraping of existing paint by power brushing or suitable method and clearing of surface free from foreign
50 materials as per the instructions of GSPL EIC.
2”NB to 8"NB 1 Nos. 4000 4000 9 9
10” NB to 18"NB 1 Nos. 4500 4500 9 9
24” NB to 36"NB 1 Nos. 5000 5000 9 9
Supply, Fabrication, Transportation and Installation of lighting Pole with required paint & pole identification tag: material
of GI pipe 4.5 mm thick Make-TATA/Jindal GI pipes and GI reducers of height approximately 5 to 12 Meter as per the
drawing attached including installation of luminaire, JBs, Earthing connection, cable connection etc.on new pole.
51 Type A (DWG-STD-15) 4 Nos. 14500 58000 9 9
Type B(DWG-STD-16) 10 Nos. 25000 250000 9 9
Type C(DWG-STD-25) 1 Nos. 14500 14500 9 9
Type D(DWG-STD-24) 1 Nos. 14500 14500 9 9
Calibration of secondary instruments such as Pressure Transmitter, Diff Pressure Transmitter, Temperature
Transmitter,Pressure Guage, Diff Pressure Gauge, Temperature Gauge, RTD at respective locations. (Trained manpower as
well as master calibrator in the scope of contractor).
PT of Range (0-120kg / cm2) 150 Nos. 900 135000 9 9
TT of Range (-30 to + 55 deg. C) 125 Nos. 900 112500 9 9
52
PG of Range (0-120 bar) 125 Nos. 700 87500 9 9
TG of Range (0-100 degree C) 20 Nos. 250 5000 9 9
DPG (0-2 kg/cmM2) 25 Nos. 700 17500 9 9
DPT (0-2 kg/cmM2) 25 Nos. 700 17500 9 9
RTD (PT 100) 180 Nos. 850 153000 9 9
Safety valve calibration of sizes as given below with men, materials tools & tackles, consumables. The job including
dismantling of safety valve from the filter equipment/Pipeline/ Launcher/Receiver/Actuator Valve cylinders at height of
maximum 3 meter, blinding of one upstream side of line flange of removed space of safety valve, Cleaning of all
components by kerosene if required, Lapping of nozzle & disc if required,assembly of valve with repaired component,
Calibration and Testing as found as left set pressure of safety valve at spot with all required materials tools & tackles. seat
tightness required at 90% of test pressure & calibration of PG is required. Re-installation/errection of safety valve on
equipment/Pipeline/ Launcher/Receiver/Actuator Valve cylinders in position after testing/calibration. Consumable such as
53 nitrogen, grease, testing gaskets & painting of Valves etc shall be arranged at site by the contractor for the above job. Gasket
for the pipes / joint flanges shall provided by GSPL. Issuing a certificate of calibration by a competent person. The job shall
be done by the competent person who has certificate possessing by issued Factory Inspector. All type of transportation is
included in the job
For Actutor Valve (Size below1") 175 Nos. 2500 437500 9 9
up to 2" 175 Nos. 3000 525000 9 9
above 2" 10 Nos. 3500 35000 9 9
Supply and mobilization of Nitrogen gas of commercial grade in loose Cylinder / banks of individual cylinder capacity 7m3
at a pressure of 150 kg/Sq cm with all connecting hoses and de-mobilization after completion of job including loading,
54 800 Cu. Mtr. 136000 9 9
unloading, handling Cylinder pressure regulator and pressure gauge with accessories.No separate charges shall be paid for
manpower, tools & tackles, lifting equipments used during this activity. 170
Removal,Refilling & re-installation of pilot Nitrogen Gas cylinder,Water Capacity:6.8 Ltr, Pressure: 150 Kg/Cm2 including
55 transportation to & from site. No separate charges shall be paid for manpower, tools & tackles, lifting equipments used 15 Nos. 10500 9 9
during this activity. 700
Removal, Refilling & Re-installation of pilot Nitrogen Gas cylinder, Water Capacity: 2 Ltr, Filling Pressure: 165 Kg/Cm2
56 @ 15 degree C including transportation. No separate charges shall be paid for manpower, tools & tackles, lifting equipments 1 Nos. 700 9 9
used during this activity. 700
Removal, Refilling & re-installation of CO2 Gas cylinders used for flooding system of Water Capacity: 68 Ltr, Pressure: 45
Kg/Cm2 including to & fro transportation.
57 50 Nos. 137500 9 9
(CO2 refilling shall be carried out thru PESO approved vendor only). No separate charges shall be paid for manpower,
tools & tackles, lifting equipments used during this activity. 2750
58 Arrangement and supply of water in tanker / truck / lorry only for fire fighting during emergency. 10,000 Litres 1 Nos. 6000 6000 9 9

Monitoring and Maintenance of earthing system as per AMS (Annual Maintenance Schedule) by measuring earth pit
resistance. The job includes cleaning of pit, checking and recording of earthing system circuit resistance by disconnecting
Earth pit from the equipments (provide alternative earthing if needed) and measure the earthing resistance of the
disconnected pit by Winner's three pin method. The earth pit resistance value to be measured under two separate condition
59 viz. (1) isolated from earthing grid and (2) when connected to earthing grid. After measurement it is re-connected and 4000 Per Pit 1200000 9 9
tightness of all connection to be confirmed. Anti corrosion gel /jelly shall be applied to all earthing connections checked.
Supply & replacement of nut bolts, if required. The work includes adding salt water to the earth pits if required and
replacement of nut bolts. The job shall be carried out by a qualified electrical engineer and endorsed by a competent
authority of respective region and submission of reports

300
Supply & installation of Copper earthing cable 16 sq mm. The job includes the excavation, removal of exisitng Copper
60 Strip, laying of new cable, back-filling & restoration. No separate charges shall be paid for manpower, tools & tackles, 60 R. Mtr. 15600 9 9
equipments, instruments used during this activity. 260

OFC-24 fiber Jointing at pit location by preparation of fiber, removal of the sheath, cleaning of the fiber, fixing the fiber to
the LIU with proper clamping / ties. Numbering of the fiber using ferrules, splicing the fiber to the pigtail, proper routing of
the fiber in the cassette. Proper closure of the cassette, connecting the pigtail to the adapter, and marking the same, for 1-24
fibers joints. Job Include Supply of Jointing Enclosure for 24 core Fiber Cable, Weather proof, as per Standard
Specification and approved make ( Raychem, 3 M make ) and Fault finding & identification using OTDR. End to end
testing of fibres after jointing and submission of report. Incase of unacceptable dB loss at repair joint same needs to be
61 20 Per joint 160000 9 9
rectified with-out any cost implication to GSPL. Final end to end OTDR test shall be carried-out for all 24 Fibres & submit
the report without any cost implication to GSPL. No separate charges shall be paid for manpower,instruments,
transportation used during this activity. Visit for fault finding & final testing shall be considered as one visit only. Complete
Link Testing End to End with Power Source, Laser Source, OTDR meter working with 1310 nm and 1550 nm from both
end including Pigtails, Patch cord for testing. Submission of all 24 core OTDR traces between two terminals or across the
joints. Pit Excavation & back-filling be paid as per relevant SOR.

8000
Illumination Monitoring at various GSPL terminals at Night including required calibrated instrument and transportation
62 160 per Station 400000 9 9
upto the respective sites as per instruction of EIC. Report shall be submitted in GSPL approved format 2500
Environmental Monitoring by carrying out the Ambient air quality measurement for Particulate Matter (P.M10 & PM 2.5),
Oxides of Sulphur (SOx) and Oxides of Nitrogen (NOx) and Noise level measurement at least 7 different spot ( i.e.
7samples) as per GSPL format/EIC Instruction & GPCB norms in each SV station for 24 hrs and analysis of the result for 140 Per Station 770000 9 9
63 submitting to GPCB as per scope of work and instruction by Engineer-in-charge. The scope includes noise level recordiing
for HVS machines also.Noise level monitoring includes DG area during day & night time. 5500
D.G Sets Stack monitoring as per GPCB norms from 45 KVA to 125 KVA 20 Nos. 3500 70000 9 9
64 Potable drinking water analysis as per BIS-10500 (2012) 20 Per Sample 4500 90000 9 9
Collection of hazardous wastes including used engine oil, gear oil, hydraulic oil , turbine oil , compressor oil , transformer
65 oil ,spent oil, filter elements, grease contaminated cotton waste etc. from GSPL stations and disposal-off the same to an 800 Kg 32000 9 9
approved CPCB / GPCB vendor by complying Hazardous Waste (Management and Handling) Rules, 1989. 40
Transportation of diesel in 200 liter capacity of MS barrel from GSPL approved diesel bunk station to GSPL’s Central
storage location and from there or directly from diesel bunk to different SV stations or as directed by engineer-in-charge for
fueling the DG sets. The job includes loading of filled drums in vehicle, transportation abiding all safety precautions and
66 unloading at designated places. Transportation shall maximum of 999 litters at a time.
30-50 KM 1 Per Trip 2000 2000 9 9
66

51-75 KM 1 Per Trip 3000 3000 9 9


76-100 KM 1 Per Trip 4500 4500 9 9

Supply, installation testing & commissioning of Copper earthing: the job includes:
a) Excavation of a pit of size (900 mm x 900mm x 3500mm deep)
b) placement of Copper earth plate (600mm x600mm x3 6mm) and embedding the GI pipe of 20mm, 3Mtr. length in the
earth
c) back filling the pit with alternate layers of approx 100Kg Charcoal and 50 Kg salt to cover the earth plate
The pit shall further be refilled with earth upto ground level and compacted. Copper Strip (Size 25mm X 3 6mm) 2 nos.
67 20 Nos. 440000 9 9
shall be provided from plate electrode to ground level to facilitate jointing with earth wire. It shall be provided with test link
for testing of the particular earth pit. The funnel shall be installed above the ground for facilitating pouring of water. The
funnel of earthing pits shall be covered by brick masonary chamber (Size 900mm x 900 mm x 600mm) with cement plaster
on inside and outside. The chamber shall be provided with a hinged MS cover and frame fixed on chamber alognwith
tagging on MS plate (400x100mm). The resistance of the pit must be achieved below 1 ohm

22000

Supply, Installation, Testing & Commissinong of GI Pipe Earthing. A Pit (Size : 3500 mm deep) shall be excavated by
auguring or otherwise, 65 dia GI pipe 3.5 Mtr. length shall be put. The GI pipe shall be cut tapered at the bottom and
provided with holes of 12 mm dia. drilled at 75 mm interval upto 2.5 Mtr. length from bottom.The pit shall be back filled
with alternate layers of appx 100 kg of charcoal and 50 kg of salt. The Pit shall further be refilled with earth upto ground
level and compacted. GI Strip size 50x12mm shall be welded to this GI Pipe at ground level to facilitate jointing with earth
68 1 Nos. 22000 9 9
wire. It shall be provided with test link for testing of the particular earth pit. The funnel shall be installed above the ground
for facilitating pouring of water. The funnel of earthing pits shall be covered by brick masonary chamber (Size 900mm x
900mm x 600mm) with cement plaster on inside and outside. The chamber shall be provided with a hinged MS cover and
frame fixed on chamber alongwith tagging on MS plate (400x100mm). The resistance of the pit must be achieved below 1
ohm.
22000
69 Supply, installation testing & commissioning of Copper earthing, Chemical Maintenance Free Earth Pit 30 Nos. 18500 555000 9 9
70 Supply, installation testing & commissioning of GI earthing, Chemical Maintenance Free Earth Pit 50 Nos. 18000 900000 9 9
Supply, Laying & Installation of Copper earthing strip – 50x 6 mm (Above ground / Under Ground) with over lapping of
minimum 75 mm at joints and two consecutive strip be bolted together with copper bolt., Job includs cutting the strip
71 200 Mtr. 140000 9 9
suitable to site, edge preparation , excavation of required length, strip laying and back filling after completion , site welding
and bending and termaination as per EIC, supply of connection bolts etc. 700
Supply, Laying & Installation of Copper earthing strip – 25 x 3 mm (Above ground / Under Ground) with over lapping of
minimum 75 mm at joints and two consecutive strip be bolted together with copper bolt., Job includs cutting the strip
72 80 Mtr. 48000 9 9
suitable to site, edge preparation , excavation of required length, strip laying and back filling after completion , site welding
and bending and termaination as per EIC, supply of connection bolts etc. 600
Supply, Laying & Installation of GI earthing strip – 50 x 6 mm, (Above ground) with over lapping of minimum 75 mm at
73 joints and two consecutive strips to be welded together and applying bitumin on the joint. Separate charges will not be paid 300 Mtr. 69000 9 9
for manpower, tools & tackles, consumables used for this activity. 230
Supply, Laying & Installation of GI earthing strip – 50 x 6 mm, (Under Ground) with over lapping of minimum 75 mm at
74 joints and two consecutive strips to be welded together and applying bitumin on the joint. Separate charges will not be paid 80 Mtr. 26400 9 9
for excavation, backfilling, manpower, tools & tackles, consumables used for this activity. 330
Supply, Laying & Installation of GI earthing strip – 25 x 3 mm, (Above Ground) with over lapping of minimum 75 mm at
75 joints and two consecutive strips to be welded together and applying bitumin on the joint. Separate charges will not be paid 80 Mtr. 16000 9 9
for excavation, backfilling, manpower, tools & tackles, consumables used for this activity. 200
Supply, Laying & Installation of GI earthing strip – 25 x 3 mm, (Under Ground) with over lapping of minimum 75 mm at
76 joints and two consecutive strips to be welded together and applying bitumin on the joint. Separate charges will not be paid 200 Mtr. 60000 9 9
for excavation, backfilling, manpower, tools & tackles, consumables used for this activity. 300
Replacement of concrete/ MS plate covers of Earth Pits by hinged acrylic covers with locking/bolting facility & with
77 facility to change testing date. The related modifications of massonary works of Earth pits shall be in the scope of the 20 Nos. 39000 9 9
contractor. 1950
78 Supply & replacement of earth pit covers (Precast bid material) 50 Nos. 1950 97500 9 9
79 Tagging of Earth Pit on MS Plate of size (400x100 mm2) 40 Nos. 300 12000 9 9

Supply and Installation of LED tube light having 20W Al body T8 Tube Rod with colour temp. 6500K of
80 20 Nos. 8000 9 9
Bajaj/Philips/CG/Osram/Halonix/Syska/Wipro Make or other makes as per the GSPL Vendor list
400

Supply and Replacement of Lamps (Bajaj/Philips/CG/Osram/GE Make or other makes as as per the GSPL Vendor lsit
attached with this tender) including scaffolding, men, machinery if required as per EIC

Pin/ Thread Type – 70/80w HPSV 20 Nos. 275 5500 9 9


70w-HPMV 20 Nos. 275 5500 9 9
Pin/ Thread Type – 125w – HPMV 200 Nos. 300 60000 9 9
Pin/Thread Type - 250w - HPMV 20 Nos. 480 9600 9 9
Pin/ Thread Type - 150w - HPSV 100 Nos. 960 96000 9 9

81
Pin/ Thread Type – 250w – HPSV 200 Nos. 460 92000 9 9
Pin/ Thread Type – 400w – HPSV 20 Nos. 620 12400 9 9
81 36/40w Four Pin CFL 200 Nos. 280 56000 9 9
11 w CFL 100 Nos. 240 24000 9 9
18 w Four/Two Pin CFL 20 Nos. 300 6000 9 9
23 w CFL 20 Nos. 400 8000 9 9
35 w CFL 20 Nos. 540 10800 9 9
70 W CFL 20 Nos. 750 15000 9 9
Tube light 36/40w 600 Nos. 135 81000 9 9
Tube light 18w 100 Nos. 130 13000 9 9
160 W MLL Lamps 20 Nos. 250 5000 9 9
150w MHT 50 Nos. 550 27500 9 9
250w MHT 30 Nos. 825 24750 9 9
400w MHT 30 Nos. 1050 31500 9 9
Supply and Replacement of Ballast (Bajaj/Philips/CG/Osram/GE Make or Other makes as per the GSPL Vendor list
attached with this tender) including scaffolding, men, machinery if required as per EIC
70/80w HPSV 30 Nos. 500 15000 9 9
125w – HPMV 130 Nos. 550 71500 9 9
250w - HPMV 30 Nos. 825 24750 9 9
150w – HPSV 100 Nos. 850 85000 9 9
82 250w - HPSV 200 Nos. 1200 240000 9 9
400w – HPSV 15 Nos. 1800 27000 9 9
36/40w VPIT Choke 40 Nos. 275 11000 9 9
9/11 w VPIT Choke 15 Nos. 290 4350 9 9
9/11 w Electronic Choke 15 Nos. 290 4350 9 9
18 w Electronic Choke 15 Nos. 290 4350 9 9
36/40w Electronic Choke 500 Nos. 250 125000 9 9
Supply and Replacement of Lamp Holder at a height up to 12 Mtr. including Collapsible Telescopic ladder & other
arrangements. Test certificate of ladder must be availabe at the point of use.
70/80w HPSV 1 Nos. 140 140 9 9
125w – HPMV 20 Nos. 150 3000 9 9
250w – HPMV 10 Nos. 180 1800 9 9
150w – HPSV 10 Nos. 155 1550 9 9
250w – HPSV 10 Nos. 180 1800 9 9
400w – HPSV 10 Nos. 240 2400 9 9
18w - CFL 10 Nos. 140 1400 9 9
36/40w Four Pin CFL 10 Nos. 120 1200 9 9
83 Tube light 36/40w 150 Nos. 170 25500 9 9
Long Distance Capacitors 1 Nos. 320 320 9 9
Short Distance Capacitors 6 Nos. 180 1080 9 9
Supply & Replacement of LED 36 W 1 Nos. 550 550 9 9
Supply & replacement of 120 W flood light LED fixture 1 Nos. 8500 8500 9 9
Supply & replacement of 120 W flood light LED 1 Nos. 8500 8500 9 9
Supply & replacement of 72 W street light LED fixture 1 Nos. 5850 5850 9 9
Supply & replacement of 72 W street light LED 1 Nos. 5850 5850 9 9
Supply & replacement of 45 W flameproof street light LED fixture 1 Nos. 7000 7000 9 9
Supply & replacement of 45 W flameproof street light LED 1 Nos. 7000 7000 9 9
Supply & replacement of 30 W, 12V light LED for Solar light 1 Nos. 8000 8000 9 9
Supply, Erection and Installation of Halogen lamp along with fixtures (Bajaj/Philips/CG/Osram/GE Make or Other makes
as per the GSPL Vendor list attached with this tender)
84
150 W 1 Nos. 2000 2000 9 9
500 W 1 Nos. 2500 2500 9 9
Supply and Installation of HPSV Integral flood light fixture of Approved Make as per the GSPL Vendor list attached with
this tender made of pressure die-cast aluminium housing in powder coated black finish. Heat resistant toughened glass fixed
to housing by stainless steel toggles. Pre-anodised asymmetric hammered finish aluminium reflector along with side
85 reflectors. Control gear housing wired with ballast, lamp and accessories etc. confirming to IP 65 alongwith M.S cradle for
facilitating ease of mounting.
150W 6 Nos. 5000 30000 9 9
250W 15 Nos. 5250 78750 9 9
86 Supply and insallation of 2 X18 W Optic lighting fixure surface mounted including electronic choke and lamp 1 Nos. 2500 2500 9 9
87 Supply and installation of 2 X 36W FTL industrial type fixture including electronic choke and lamp 1 Nos. 1950 1950 9 9
Supply and Installation of 12V, up to 30W LED Fixture for Solar Light of Approved Make as per the GSPL, Cofirming to
88 1 Nos. 18000 9 9
IP65. 18000
Supply and Installation of LED Street light 60 W of Bajaj/Philips/CG/Osram/Halonix/Syska/Wipro Make or other makes as
89 1 Nos. 7500 9 9
per the GSPL Vendor list having IP66 or more 7500
90 Supply and installation of 50 W/100 W LED Streetlight luminaire Approved Make as per the GSPL Vender List 1 Nos. 9800 9800 9 9
Supply and Installation of LED Flood light 120 W of Bajaj/Philips/CG/Osram/Halonix/Syska/Wipro Make or other makes
91 1 Nos. 12500 9 9
as per the GSPL Vendor list having IP66 or more 12500
92 Supply and installation of 150 W/200 W LED Floodlight luminaire Approved Make as per the GSPL Vender List 1 Nos. 17500 17500 9 9
Supply and Installation of LED Flameproof light 40 W of Bajaj/Philips/CG/Osram/Halonix/Syska/Wipro Make or other
93 1 Nos. 8500 9 9
makes as per the GSPL Vendor list having IP66 or more 8500
Supply, erection and Installation of LED, Integral Flameproof Well Glass Lighting Fixture of Approved Make as per the
94 1 Nos. 7500 9 9
GSPL Vendor list 7500
Supply, erection and Installation of 125 W HPMV, Integral Flameproof Well Glass Lighting Fixture of Approved Make as
per the GSPL Vendor list attached with this tender, made of cast aluminium alloy LM6, with in built control gear box with
95 1 Nos. 2550 9 9
bulb, ballast completed with all accessories Flameproof to gas group IIA & IIB and Weather proof to IP 65, with 2 nos. of
cable entry of 3/4" ET. 2550
Supply and Installation of single/twin 36/40w tube light fixture Approved Make as per the GSPL Vendor list attached with
this tender having FRP (Fiber glass reinforced polyester) housing with rubber gasket and clear acrylic cover with stainless
96 steel toggles. The fixture should have stove enemeled white CRCA gear tray cum reflector, electronic choke, 36/40w TL 20 Nos. 39500 9 9
complete with all accessories. It should be suitable for direct mounting or suspension.
1975

Supply & Installation of functional widespread luminaires for recessed mounting in modular strip ceilings suitable for 2 x
36w TL fluorescent lamps/ LED lights. Housing shuold be made of CRCA sheet steel, powder coated white, accomodating
all electrical accessories pre-wire up to a terminal block. Designed for mounting into modular strip ceilings. The optical
97 5 Nos. 9250 9 9
system should be fixed on the luminaire by four spring clips and be suspendable during re-lamping / maintenance. The
optical system should have high efficiency mirror optics of standard aluminium with faceted side reflectors and diffuse
white lamellae. The fixture shall be supplied with electronic choke, 2 x 36w TL complete with all accesories.
1850
Supply and Installation of LED Type Indication Lamp in Panel.
Red Colour , 230 V AC 10 Nos. 200 2000 9 9
Yellow Colour , 230 V AC 10 Nos. 200 2000 9 9
Blue Colour , 230 V AC 10 Nos. 200 2000 9 9
98
Green Colour , 230 V AC 10 Nos. 200 2000 9 9
Red Colour , 12 V DC 10 Nos. 200 2000 9 9
Red Colour , 24 V DC 10 Nos. 200 2000 9 9
Green Colour , 24 V DC 10 Nos. 200 2000 9 9
Supply & Instalaltion of L&T or euqivalent Make SFU (4 pole) with Top & Bottom Fabricated Enclosure for Cable Entry of
FN-Series.
99
FN-150 5 Nos. 13000 65000 9 9
FN-200 5 Nos. 16500 82500 9 9
Suppy and replacement of Capacitors
(Bajaj/Philips/CG/Osram/GE Make or other makes as per the GSPL Vendor list attached with this tender)
1 mfd 1 Nos. 80 80 9 9
1.5 mfd 1 Nos. 80 80 9 9
2 mfd 1 Nos. 90 90 9 9
4 mfd 20 Nos. 110 2200 9 9
100
10 mfd 30 Nos. 130 3900 9 9
15 mfd 15 Nos. 150 2250 9 9
33 mfd 150 Nos. 200 30000 9 9
42 mfd 5 Nos. 260 1300 9 9
120-150 mfd 1 Nos. 340 340 9 9
250 mfd 1 Nos. 400 400 9 9
Supply & Replacement of MCB, 10 KA of Aproved Make as per the GSPL Vendor list attached with this tender
6A SP, DP, TP, TPN, FP 8 Nos. 1250 10000 9 9
10A SP, DP, TP, TPN, FP 40 Nos. 1300 52000 9 9
16A SP, DP, TP, TPN, FP 10 Nos. 1400 14000 9 9
101 25A SP, DP, TP, TPN, FP 10 Nos. 1450 14500 9 9
32A SP, DP, TP, TPN, FP 10 Nos. 1600 16000 9 9
40A SP, DP, TP, TPN, FP 1 Nos. 1650 1650 9 9
63A SP, DP, TP, TPN, FP 1 Nos. 1900 1900 9 9
100A SP, DP, TP, TPN, FP 1 Nos. 5900 5900 9 9
Supply & Replacement of MCCB, 50 KA of Aproved Make as per the GSPL Vendor list attached with this tender
32 A TP, FP 1 Nos. 14000 14000 9 9
63 A TP, FP 1 Nos. 14500 14500 9 9
100 A TP, FP 1 Nos. 15000 15000 9 9
102
125 A TP, FP 1 Nos. 17500 17500 9 9
102
150 A FP 1 Nos. 19000 19000 9 9
200 A FP 1 Nos. 20000 20000 9 9
250 A TP, FP 1 Nos. 22000 22000 9 9
Supply & Replacement of ELCB/RCCB of Aproved Make as per the GSPL Vendor list attached with this tender
Upto 25 A DP 1 Nos. 2400 2400 9 9
103
Upto 63 A DP, FP 30mA 1 Nos. 3000 3000 9 9
Upto 63 A DP, FP 100mA 1 Nos. 3700 3700 9 9
Supply and Replacement of HRC Fuse of Aproved Make as per the GSPL Vendor list attached with this tender
Upto 16 A 130 Nos. 200 26000 9 9
25 A 1 Nos. 240 240 9 9
104 32 A 1 Nos. 250 250 9 9
63 A 6 Nos. 320 1920 9 9
100 A 4 Nos. 430 1720 9 9
200 A 4 Nos. 670 2680 9 9
Supply and Replacement of Backalite Fuse Fittings of Aproved Make for below given size
105 20 Amps 10 Nos. 280 2800 9 9
30 Amps 10 Nos. 280 2800 9 9
Supply and Installation of utility spares of Aproved Make as per the GSPL Vendor list attached with this tender
3 Pin Plug Top upto 16A 6 Nos. 110 660 9 9
3 Pin Socket (With/Without Safety Shutter) upto 16A 15 Nos. 250 3750 9 9
Piano switch upto 16 A (single pole) (Industrial/Decorative) 30 Nos. 220 6600 9 9
Piano switch upto 32 A (double pole) (Industrial/Decorative) 6 Nos. 410 2460 9 9
3 Pin Switch Socket board upto 16 A with indicator (PVC/ Acrylic/Metal) 8 Nos. 400 3200 9 9
3 Pin 6/16 A surface type combined switch socket outlet (Industrial/Decorative) 12 Nos. 400 4800 9 9
106 3 Pin 6/16 A flush type socket outlet 1 Nos. 280 280 9 9
Switch type fan regulator Electronic 6 Nos. 280 1680 9 9
Socket type fan regulator Electronic 1 Nos. 350 350 9 9
25 mm dia PVC conduit 4 Mtr. 70 280 9 9
PVC Casing / Capping of size upto 50 x 16 mm 6 Mtr. 70 420 9 9
PVC Flexbile Corrugated Conduit upto size 50 mm 1 Mtr. 80 80 9 9
Starter for Tubelight 36/40w 20 Nos. 35 700 9 9
Ignitor 70/150/250/400 w supporting upto 30 Mtr.s. 400 Nos. 270 108000 9 9
107 Supply and Installation FLUSH Type On-Off Push Button switch 19mm Dia 1 Nos. 200 200 9 9
108 Supply and Installation NO Block for On-Off Push Button Flush Type 1 Nos. 120 120 9 9
109 Supply and Installation NC Block for On-Off Push Button Flush Type 1 Nos. 150 150 9 9
110 Supply and Installation STOP Push Button Switch 19mm Dia 1 Nos. 180 180 9 9
Supply and Installation of DIN Rail Mounted, Power (Bus-Bar) Terminals Type CBT suitable for cables with Ring / Fork
type lugs in Melamine Housing alongwith partition plates and end plates. The current bar should be tapped and the fixing
111 bolt should have slotted head, that allows use of screw-driver for bolting for below mentiond conductor size.
35 sq. mm. to 70 sq. mm. 1 Nos. 600 600 9 9
95 sq. mm. to 120 sq. mm. 1 Nos. 800 800 9 9
Supply and Installation of DIN Rail Mounted, Screw or Nut Driver Operated, Stud Type Terminals, TYPE CBT in
Melamine Housing with end plates for below mentioned conductor size.
112
6 sq. mm. to 16 sq. mm. 1 Nos. 240 240 9 9
25 sq. mm. to 35 sq. mm. 1 Nos. 450 450 9 9
Supply and Installation of DIN Rail Mounted Feed ThroughTerminals Type CST in Melamine Housing with end plates for
below mentioned conductor size.
113 2.5 sq. mm. to 6 sq. mm. 1 Nos. 350 350 9 9
10 sq. mm. to 25 sq. mm. 1 Nos. 450 450 9 9
35 sq. mm to 70 sq. mm. 1 Nos. 550 550 9 9
Supply and Installation of MS Junction Box of of Aproved Make as per the GSPL Vendor list attached with this tender –
114 1 Nos. 540 9 9
Size 6x4 inch 540
Supply and Installation of Four Way Flameproof Junction box of Aproved Make as per the GSPL Vendor list attached with
115 15 Nos. 28500 9 9
this tender – 125 mm 1900
Supply and Installation of PVC Junction Box of Aproved Make as per the GSPL Vendor list attached with this tender– Size
116 8 Nos. 7200 9 9
200 x 150 mm 900
Supply and Installation Side Hinged SMC FRP Based Pole mounted Junction Box for Street Light/Flood Lighting pole for
below mentioned size of Approved make like SINTEX.
117
Size 250 mm X 200 mm X 105mm 20 Nos. 1400 28000 9 9
Size 300 mm X 200 mm X 105 mm 30 Nos. 1700 51000 9 9
Supply and Installation of Terminal Connectors in Electrical Panels & Junction bos suitable to Din Rail type mounting for
below mentioned size of Approved make with Side lolk plates/seprators Operating voltage is 440 Volts.
118 up to 16 SQmm 50 Nos. 100 5000 9 9
118
Above 16 SQmm up to-32 Sqmm 10 Nos. 125 1250 9 9
Above 32 SQm m up to-63 Sqmm 10 Nos. 180 1800 9 9
Supply and Installation of Junction Box of Aproved Make as per the GSPL Vendor list attached with this tender made of 14
119 SWG MS Sheet, of size 250mm x 200mm x 125 mm, having canopy, pole mounting bracket, hinged door with lock, two 1 Nos. 900 9 9
earth studs, 19 dia conduit welded with box for cable outlet to pole, and 4 way terminal block. 900
Supply and Installation of Bolt on/Din-Rail Industrial type Fabricated Finished Enclosure (MCB Distribution Box)of
Aproved Make Legrand, Hawells
120
4P MCB 4-Way Bolt on Type/Din Rail Type 8 Nos. 500 4000 9 9
4P MCB 8-Way Bolt on Type/Din Rail Type 5 Nos. 700 3500 9 9
Supply and Replacement of Acrylic Cover for Gate light doom & fixture of 70 - 80W-- HPSV.
121 1 Nos. 1250 9 9
(Bajaj/Philips/CG/Osram/GE Make or Other makes as per the GSPL Vendor list attached with this tender) 1250
122 Supply and Installation of Glass Cover for 125w/250w HPMV flameproof fixture 1 Nos. 1850 1850 9 9
Supply and Installation of Post Top Lanterns of Aproved Make as per the GSPL Vendor list attached with this tender for
123 8 Nos. 23600 9 9
Gate Lighting with IP 54 Protection, Complete with lamp and gear box and all accessories, CG Make 2950
Supply and Replacement of Pressure Regulator (Make:GSPL approved vendor, Gas: N2, inlet: 150 Kg/cm2 & outlet: 4-
124 1 Nos. 5600 9 9
10Kg/CM2) 5600
Supply & Installation of OPTICAL-PHOTOELECTRIC SMOKE DETECTOR of of Aproved Make as per the GSPL
125 1 Nos. 3100 9 9
Vendor list attached with this tender 3100
Supply and Installation of SS 316, double compression type Cable Glands for armoured twin and multicore power cables of
voltage grade 650/1100 V and Instrument cables alongwith PVC Shrouds. The Glands Shall be Flameproof to Gas Group
IIA, IIB and / or Weatherproof to IP 65, for cables having overall diameters as given below.
126 19 mm 80 Nos. 190 15200 9 9
25 mm 40 Nos. 270 10800 9 9
40 mm 1 Nos. 750 750 9 9
80 mm 1 Nos. 2100 2100 9 9
Sealing of Junction box,cable gland, Electrical & Instrumentation cable rising PVC/GI Pipe, Electrical & Instrumentations
127 Cable Entry/Exit holes Electrical & Instrumentation box by PUF seal (1K-S) make:Stanvac including supply of the 100 Nos. 23000 9 9
Material 230
Maintenance of Junction box including Cleaning, supply & replacement of Rubber Seal,Nut-Bolt , Entry Plug, Gland &
128 Washer. No separate charges shall be paid for manpower, Rubber seal, Nut-Bolt, entry plug, Gland, washer, consumables, 200 Nos. 27000 9 9
tools & tackles used during execution of this activity. 135
Cable Fault Repairing - Supply and installation of M-Seal Cable Jointing Kits for following Cables including IR test and
Re-commissioning of cable. The work includes excavation upto the cable, making required trenches for execution of job
and backfilling the area. No separate charges shall be paid for manpower, excavation, backfilling, consumables,
129 equipments, tools & tackles used during execution of this activity.
Upto 3 C x 25 sq. mm. Cu. Armoured Cable 1 Nos. 2400 2400 9 9
Upto 4 C x 25 sq. mm. Cu. Armoured Cable 1 Nos. 2700 2700 9 9
Supply and Installation of Cable Jointing Kit for Following Cable (3M/Raychem Make) including IR test and Re-
commissioning of cable.The work includes excavation upto the cable, making required trenches for execution of job and
backfilling the area. No separate charges shall be paid for manpower, excavation, backfilling, consumables, equipments,
tools & tackles used during execution of this activity.
Upto 3.5 C x 50 sq. mm. Al. Armoured Cable 1 Nos. 2250 2250 9 9
130
Upto 4 C x 50 sq. mm. Al. Armoured Cable 1 Nos. 2350 2350 9 9
3.5 C x 70 sq. mm. Al. Armoured Cable 1 Nos. 2500 2500 9 9
3.5 C x 95 sq. mm. Al. Armoured Cable 1 Nos. 2600 2600 9 9
3.5 C x 300 sq. mm. Al. Armoured Cable 1 Nos. 4350 4350 9 9
3.5 C x 120 sq. mm. Al. Armoured Cable 1 Nos. 2700 2700 9 9

Supply, Laying
& Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts of
following sizes Above-Ground on cable trays, supported on steel structures, in ready made trenches. The rates shall include
the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars, lugs, ferrules, double compression type
SS glands, etc, including transportation with all labor and materials as per the specifications, drawings and directions of
Engineer-in-charge . The Insulation Resistance of cable has to be checked & report to be submitted before commissioning.
No separate charges shall be paid for manpower,consumables, tools & tackles used during execution of this activity.

Upto 2 C x 6 sq. mm. Cu. Armoured Cable 1 Mtr. 330 330 9 9


Upto 3 C x 6 sq. mm. Cu. Armoured Cable 250 Mtr. 300 75000 9 9
Upto 4 C x 6 sq. mm. Cu. Armoured Cable 80 Mtr. 350 28000 9 9
131 3 C x 10 sq. mm. Cu. Armoured Cable 40 Mtr. 455 18200 9 9
4 C x 10 sq. mm. Cu. Armoured Cable 1 Mtr. 610 610 9 9
3 C x 16 sq. mm. Cu. Armoured Cable 1 Mtr. 610 610 9 9
4 C x 16 sq. mm. Cu. Armoured Cable 10 Mtr. 750 7500 9 9
3 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr. 1200 1200 9 9
4 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr. 1300 1300 9 9
1 C x 25 sq. mm. Cu. Armoured Cable 10 Mtr. 350 3500 9 9
Upto 3.5 C x 50 sq. mm. Al. Armoured Cable 1 Mtr. 360 360 9 9
Upto 4 C x 50 sq. mm. Al. Armoured Cable 30 Mtr. 390 11700 9 9
3.5 C x 70 sq. mm. Al. Armoured Cable 1 Mtr. 460 460 9 9
3.5 C x 95 sq. mm. Al. Armoured Cable 1 Mtr. 550 550 9 9
3.5 C x 120 sq. mm. Al. Armoured Cable 1 Mtr. 680 680 9 9

Laying &
Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts of
following sizes Above-Ground on cable trays, supported on steel structures, in ready made trenches. The rates shall include
the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars, lugs, ferrules, double compression type
SS glands, etc, . Only Cable will be supplied by GSPL at designated stores.The Insulation Resistance of cable has to be
checked & report to be submitted before commissioning.No separate charges shall be paid for transportation of cables from
GSPL designated stores to the site, manpower, consumables, equipments, tools & tackles used during execution of this
activity.
132
Upto 2 C x 6 sq. mm. Cu. Armoured Cable 1 Mtr. 170 170 9 9
Upto 4 C x 25 sq. mm. Cu. Armoured Cable 40 Mtr. 175 7000 9 9
Upto 3.5 C x 50 sq. mm. Al. Armoured Cable 40 Mtr. 185 7400 9 9
Upto 4 C x 50 sq. mm. Al. Armoured Cable 1 Mtr. 320 320 9 9
3.5 C x 70 sq. mm. Al. Armoured Cable 1 Mtr. 340 340 9 9
3.5 C x 95 sq. mm. Al. Armoured Cable 1 Mtr. 350 350 9 9
3.5 C x 300 sq. mm. Al. Armoured Cable 1 Mtr. 400 400 9 9
3.5 C x 120 sq. mm. Al. Armoured Cable 1 Mtr. 370 370 9 9
Supply, Laying & Termination of PVC insulated, FRLS Outer sheathed, PVC Inner Sheathed instrumentation Cable
Voltage grade 650 / 1100 Volts of following sizes Above-Ground on cable trays, supported on steel structures, in ready
made trenches. The rates shall include the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars,
lugs, ferrules, double compression type SS glands, etc, including transportation with all labor and materials as per the
specifications, drawings and directions of Engineer-in-charge . No separate charges shall be paid for
manpower,consumables, tools & tackles used during execution of this activity.
133
Instrument cable upto 2P x 1.5sqmm armoured cable 100 Mtr. 135 13500 9 9
Instrument cable upto 6P x 1.5sqmm armoured cable 8 Mtr. 340 2720 9 9
Instrument cable upto 12P x 1.5sqmm armoured cable 1 Mtr. 460 460 9 9
Flexible cable upto 1 C x 6 sq. mm. cable 150 Mtr. 120 18000 9 9
Flexible cable upto 3 C x 6 sq. mm. cable 1 Mtr. 210 210 9 9
Non-FRLS Flexible Earthing cable of size upto 25 sq. mm. 250 Mtr. 225 56250 9 9
Laying & Termination of PVC insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts
of following sizes Above-Ground on cable trays, supported on steel structures, in ready made trenches. The rates shall
include the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars, lugs, ferrules, double
compression type SS glands, etc, Cable will be supplied by GSPL at designated stores. No separate charges shall be paid for
transportation of cables from GSPL designated stores to the site, manpower, consumables, equipments, tools & tackles used
during execution of this activity
134
Instrument cable upto 2P x 1.5sqmm armoured cable 100 Mtr. 110 11000 9 9
Instrument cable upto 6P x 1.5sqmm armoured cable 15 Mtr. 120 1800 9 9
Instrument cable upto 12P x 1.5sqmm armoured cable 25 Mtr. 150 3750 9 9
Flexible cable upto 1 C x 6 sq. mm. cable 1 Mtr. 60 60 9 9
Flexible cable upto 3 C x 6 sq. mm. cable 40 Mtr. 80 3200 9 9
Non-FRLS Flexible Earthing cable of size upto 25 sq. mm. 15 Mtr. 100 1500 9 9

Supply, Laying & Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 /
1100 Volts of following sizes Under-Ground and / or pull through pipes including excavation and backfilling etc. Work
includes excavation of trench of average 0.5 meter wide & up to 1.2 meter depth with all appropriate tools & tacles( manual
work inside terminals). Layer of sand shall be of 100 mm thick & brick layer shall be laid on cable for protection and back
filling of trench after completion of work. work includes carting of surplus earth/debris and handling/unrolling of cable,
supply of auminium tags, lugs, ferrules, double compression type SS glands, etc, including transportation with all labor and
materials as per the specifications, drawings and directions of Engineer-in-charge . The Insulation Resistance of cable has to
be checked & reported before commissioning.No separate charges shall be paid for excavation, backfilling, manpower,
consumables, equipments, tools & tackles used during execution of this activity

Upto 3 C x 6 sq. mm. Cu. Armoured Cable 500 Mtr. 300 150000 9 9
Upto 4 C x 6 sq. mm. Cu. Armoured Cable 100 Mtr. 350 35000 9 9
3 C x 10 sq. mm. Cu. Armoured Cable 1 Mtr. 500 500 9 9
135
4 C x 10 sq. mm. Cu. Armoured Cable 50 Mtr. 600 30000 9 9
3 C x 16 sq. mm. Cu. Armoured Cable 1 Mtr. 700 700 9 9
4 C x 16 sq. mm. Cu. Armoured Cable 25 Mtr. 900 22500 9 9
3 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr. 1000 1000 9 9
4 C x 25 sq. mm. Cu. Armoured Cable 25 Mtr. 1100 27500 9 9
1 C x 25 sq. mm. Cu. Armoured Cable 80 Mtr. 320 25600 9 9
Upto 3.5 C x 50 sq. mm. Al. Armoured Cable 1 Mtr. 380 380 9 9
Upto 4 C x 50 sq. mm. Al. Armoured Cable 30 Mtr. 400 12000 9 9
3.5 C x 70 sq. mm. Al. Armoured Cable 1 Mtr. 800 800 9 9
3.5 C x 95 sq. mm. Al. Armoured Cable 1 Mtr. 860 860 9 9
3.5 C x 120 sq. mm. Al. Armoured Cable 1 Mtr. 960 960 9 9
2 core x 1.5 mm2 Armoured Shield Data cable 1 Mtr. 375 375 9 9

Laying & Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts
of following sizes Under-Ground and / or pull through pipes including excavation and backfilling etc. Work includes
excavation of trench of average 0.5 meter wide & up to 1.2 meter depth with all appropriate tools & tacles( manual work
inside terminals). Layer of sand shall be of 100 mm thick & brick layer shall be laid on cable for protection and back filling
of trench after completion of work. work includes carting of surplus earth/debris and handling/unrolling of cable, supply of
auminium tags, lugs, ferrules, double compression type SS glands, etc, Cable will be supplied by GSPL at designated
store.The Insulation Resistance of cable has to be checked & reported before commissioning.No separate charges shall be
paid for transportation of cable from GSPL designated store to site, excavation, backfilling, manpower, consumables,
equipments, tools & tackles used during execution of this activity.

Upto 3 C x 2.5 sq. mm. Cu. Armoured Cable 130 Mtr. 175 22750 9 9
Upto 3 C x 6.0 sq. mm. Cu. Armoured Cable 1 Mtr. 350 350 9 9
136
Upto 3 C x 10.0 sq. mm. Cu. Armoured Cable 1 Mtr. 550 550 9 9
Upto 3 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr. 550 550 9 9
Upto 4 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr. 700 700 9 9
Upto 3.5 C x 50 sq. mm. Al. Armoured Cable 1 Mtr. 800 800 9 9
Upto 4 C x 50 sq. mm. Al. Armoured Cable 6 Mtr. 900 5400 9 9
3.5 C x 70 sq. mm. Al. Armoured Cable 1 Mtr. 950 950 9 9
3.5 C x 95 sq. mm. Al. Armoured Cable 1 Mtr. 1000 1000 9 9
3.5 C x 300 sq. mm. Al. Armoured Cable 1 Mtr. 1100 1100 9 9
3.5 C x 120 sq. mm. Al. Armoured Cable 1 Mtr. 1000 1000 9 9
3 C x 1 Sq mm Armoured Power Cable 1 Mtr. 220 220 9 9
2 core x 1.5 mm2 Armoured Shield Data cable 1 Mtr. 240 240 9 9

Supply & Instalaltion of GI Cable Trays with cover on MS steel sUpport. All Accessories shall be in the scope of
contractor like MS angle sUpport , channel,Fastners, Clamp,Cable tie etc. as per below mentiond size

Perforated Cable tray with cover 450 mm 35 per Mtr. 2800 98000 9 9
Perforated Cable tray with cover 300 mm 35 per Mtr. 2100 73500 9 9
137
Perforated Cable tray with cover 150 mm 35 per Mtr. 1100 38500 9 9
Perforated Cable tray with cover 100 mm 35 per Mtr. 850 29750 9 9
Ladder type Cable tray 450 mm 35 per Mtr. 2300 80500 9 9
Ladder type Cable tray 300 mm 35 per Mtr. 1700 59500 9 9
Ladder type Cable tray 150 mm 35 per Mtr. 900 31500 9 9

Supply, Laying & Termination of PVC insulated, FRLS Outer sheathed, PVC Inner Sheathed Instrumentation Cable
Voltage grade 650 / 1100 Volts of following sizes Under-Ground and / or pull through pipes including excavation and
backfilling etc. Work includes excavation of trench of average 0.5 meter wide & up to 1.2 meter depth with all appropriate
tools & tacles( manual work inside terminals). Layer of sand shall be of 100 mm thick & brick layer shall be laid on cable
for protection and back filling of trench after completion of work. work includes carting of surplus earth/debris and
handling/unrolling of cable, supply of auminium tags, lugs, ferrules, double compression type SS glands, etc, including
138 transportation with all labor and materials as per the specifications, drawings and directions of Engineer-in-charge . The
insulation resistance of cable has to be checked & reported before commissioning.No separate charges shall be paid for
excavation, backfilling, manpower, consumables, equipments, tools & tackles used during execution of this activity

Instrument cable upto 1P x 1.5sqmm armoured cable 1 Mtr. 180 180 9 9


Instrument cable upto 2P x 1.5sqmm armoured cable 300 Mtr. 200 60000 9 9
Instrument cable upto 6P x 1.5sqmm armoured cable 1 Mtr. 550 550 9 9
Instrument cable upto 12P x 1.5sqmm armoured cable 1 Mtr. 850 850 9 9
Laying & Termination of PVC insulated, FRLS Outer sheathed, PVC Inner Sheathed Instrumentation Cable Voltage grade
650 / 1100 Volts of following sizes Under-Ground and / or pull through pipes including excavation and backfilling etc.
Work includes excavation of trench of average 0.5 meter wide & up to 1.2 meter depth with all appropriate tools &
tacles( manual work inside terminals). Layer of sand shall be of 100 mm thick & brick layer shall be laid on cable for
protection and back filling of trench after completion of work. work includes carting of surplus earth/debris and
handling/unrolling of cable, supply of auminium tags, lugs, ferrules, double compression type SS glands, etc, Cable will be
139 supplied by GSPL at designated store.The Insulation Resistance of cable has to be checked & reported before
commissioning.No separate charges shall be paid for transportation of cable from GSPL designated store to site, excavation,
backfilling, manpower, consumables, equipments, tools & tackles used during execution of this activity.

Instrument cable upto 1P x 1.5sqmm armoured cable 30 Mtr. 150 4500 9 9


Instrument cable upto 2P x 1.5sqmm armoured cable 80 Mtr. 160 12800 9 9
Instrument cable upto 6P x 1.5sqmm armoured cable 25 Mtr. 170 4250 9 9
Instrument cable upto 12P x 1.5sqmm armoured cable 6 Mtr. 180 1080 9 9
Supply laying and Termination (using Conduit,Rojet Box ,temrinal block, crimping, connectors) of telecom cables
Underground/Aboveground. Cable will be supplied by GSPL at designated store.The Insulation Resistance of cable has to
be checked & reported before commissioning.No separate charges shall be paid for excavation, backfilling, manpower,
consumables, equipments, tools & tackles used during execution of this activity.
140
Polythene (Solid/Foam Skin) Insulated Jelly Filled Cables (5 Pair ) 1 Mtr. 325 325 9 9
Polythene (Solid/Foam Skin) Insulated Jelly Filled Cables (10 Pair ) 1 Mtr. 425 425 9 9
Flexible 2 pair Telephone cable 25 Mtr. 70 1750 9 9
RG-11 Video Cable 1 Mtr. 90 90 9 9

Supply & Installation of Heavy Duty Exhaust Fan, that is totally enclosed, highly efficient heavy duty motor with pressure
die cast aluminium rotor mounted on two ball bearings. Aerodynamically contoured blades and Rigid frame with rubber
mountings for silent operation. Suitable for continuous running. It should be Epoxy powder coated with specially pre-
treated components for better resistance to corrosion and acid alkali fumes. It should be supplied alongwith self opening
louvers for tota protection against birds and direct rain. The Fan should confirm to IS 2312 standards.Cable will be supplied
141 by GSPL at designated store.The Insulation Resistance of cable has to be checked & reported before commissioning.No
separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this
activity.

Size : 300 mm, Single Phase, 1400 rpm 1 Nos. 5000 5000 9 9
Size : 450mm, Single Phase, 1400 rpm 6 Nos. 6300 37800 9 9
Size : 600mm, Single Phase, 950 rpm 1 Nos. 7500 7500 9 9
Supply & Instalation of Heavy Duty Exhaust Fan, made of cast aluminium alloy LM6, Exproof to gas group IIA & IIB.
Suitable for continuos running. It should be Epoxy powder coated for resistance to corrosion and acid alkali fumes. It
should be supplied with self opening louvers for total protection against birds and direct rain. No separate charges shall be
142 paid for manpower, consumables,equipments, tools & tackles used during execution of this activity.
Size : 300 mm, Single Phase 1 Nos. 6500 6500 9 9
Size : 450mm, Single Phase 1 Nos. 7800 7800 9 9
Supply and Installation of ceiling fan(GSPL approved vendor make), white / ivory colour, 230v, 1-Phase, 1200 mm sweep.
It shall have robust two piece motor construction, All Aluminum alloy construction with double ball bearing and powder
143 25 Nos. 55000 9 9
coated finish to protect metal from corrosion.The fan shall be energy efficient having 5 star rating. No separate charges shall
be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 2200
144 Supply and Installation of Wall mounted cabin fan, 230V, 1-Phase, 300 mm sweep. 1 Nos. 2200 2200 9 9
Supply and Installation of selfpriming Monoblock pumps operating on single phase, upto rating of 1.5 HP, with matching
piping connections. Work includes dismantling of alraedy installed pump, required inlet/outlet connection, foot valves
145 6 Nos. 34800 9 9
servicing & cable termination. No separate charges shall be paid for manpower, consumables,equipments, tools & tackles
used during execution of this activity. 5800
Rewinding of the following motors/Monoblock Pump. work includes removal of the equipment, rewinding & repairing, re-
installation of the same.(Including replacement of Bearing).No separate charges shall be paid for manpower,
consumables,equipments, bearings, tools & tackles used during execution of this activity.
Ceiling fan 30 Nos. 550 16500 9 9
146 Monoblock pump of 0.5 HP 4 Nos. 2500 10000 9 9
Monoblock pump of 0.75 HP 4 Nos. 3000 12000 9 9
Monoblock pump of 1.0 HP 4 Nos. 3000 12000 9 9
Exhaust Fan heavy duty 20 Nos. 1100 22000 9 9
Exhaust Fan heavy duty explosion proof IIA & IIB 2 Nos. 1500 3000 9 9
Supply & Installation of G.I Pipe for electrical related works. No separate charges shall be paid for excavation, backfilling,
manpower, consumables, equipments, tools & tackles used during execution of this activity.
1" 12 Mtr. 250 3000 9 9
147
2" 2 Mtr. 450 900 9 9
3" 10 Mtr. 500 5000 9 9
4" 5 Mtr. 980 4900 9 9
Supply and Installation of G.I Bend Pipe ( for Cable entry). No separate charges shall be paid for excavation, backfilling,
manpower, consumables, equipments, tools & tackles used during execution of this activity.
1" 1 Nos. 120 120 9 9
148
2" 1 Nos. 180 180 9 9
3" 1 Nos. 250 250 9 9
4" 1 Nos. 300 300 9 9
Supply, Fabrication and Installation of Aluminium Canopy for Field Instruments, Open Path Gas Detectors, Flow
149 1 Kg 1000 9 9
Computers. Dimensions of the canopy as per field instrument actual at site and instruction as per EIC 1000
Supply, Fabrication and Installation of G.I Sheet Canopy for Field Instruments, Open Path Gas Detectors, Flow Computers.
150 40 Kg 9600 9 9
Dimensions of the canopy as per field instrument actual at site and instruction as per EIC 240
Supply and Installation of "U" Clamps of CS material of standard type with NPT at bolting end including polyethelyne
insulation/conduit for "U" Clamps including nuts and washers for different size of pipe clamps as per instruction of EIC. No
separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this
activity.
1/2" 6 Nos. 70 420 9 9
1" 20 Nos. 80 1600 9 9
151 2" 220 Nos. 90 19800 9 9
3" 20 Nos. 130 2600 9 9
4" 25 Nos. 150 3750 9 9
6" 12 Nos. 200 2400 9 9
8" 10 Nos. 210 2100 9 9
10' 1 Nos. 290 290 9 9
12" 1 Nos. 340 340 9 9
Supply and Installation of "U" Clamps of SS material of standard type with NPT at bolting end including polyethelyne
insulation/conduit for "U" Clamps including nuts and washers for different size of pipe clamps as per instruction of EIC. No
separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this
activity.
152 1/4" 15 Nos. 290 4350 9 9
1/2" 6 Nos. 300 1800 9 9
3/8" 100 Nos. 390 39000 9 9
3/4" 1 Nos. 500 500 9 9
1" 1 Nos. 600 600 9 9
Supply & installation of MS sheet, removal of existing sheet, if any. Powder coated, Color:Simense gray or Smoke gray or
GI Sheet along with all accessories like studs & washers. No separate charges shall be paid for manpower, consumables,
equipments, tools & tackles used during execution of this activity.
153 MS sheet 18 gauge 10 Sq. Mtr. 500 5000 9 9
MS sheet 22 gauge 1 Sq. Mtr. 690 690 9 9
GI sheet 18 gauge 1 Sq. Mtr. 690 690 9 9
GI sheet 22 gauge 1 Sq. Mtr. 690 690 9 9
Supply & installation of SS sheet Cabinet (Removal of old SS Sheet Cabinet from Actuator Valve/Equipment, if
any)conforming to IP65 for Actuator Valve/Any Equipment along with all provisions for cable entry, glands, accessories
like studs & washers
154 SS sheet 18 gauge Upto 12"Valve 1 Nos. 10500 10500 9 9
SS sheet 18 gauge Above 12"Valve 1 Nos. 11000 11000 9 9
SS sheet 22 gauge upto 12"Valve 1 Nos. 9500 9500 9 9
SS sheet 22 gauge above 12"Valve 4 Nos. 10000 40000 9 9
Supply and placing of insulation Rubber Mats( 2 mm thick, class-A, Colour-Blue) as per IS15652;2006(New IS Standard)
155 & of approved make of GSPL Vendor list attached with the tender. Material batch test certificate shall be provided along 1 Sq. Mtr. 1890 9 9
with material. 1890
Supply and placing of insulation Rubber Mats( 2.5 mm thick, class-B, Colour-Blue) as per IS15652;2006(New IS Standard)
156 & of approved make of GSPL Vendor list attached with the tender. Material batch test certificate shall be provided along 1 Sq. Mtr. 2200 9 9
with material. 2200
Painting of lighting pole/ Solar pole / OPD Pole/chimeny/ Stack including surface preperation, supply of paint and
application of 2 coat of high build chlorinated rubber / zinc phosphate primer and two coats of finished paint of epoxy paint
of Silver colour approved make as per the GSPL Vendor list attached with this tender to give an even shade after proper
removal of existing paint by power brushing or suitable method and clearing of surface free from foreign materials. No
separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this
activity.
157
Upto 4.5 Meter Height Pole (FLP Light pole in process area) 35 Nos. 1800 63000 9 9
Upto 6 Meter Height Pole (Solar Light) 20 Nos. 2000 40000 9 9
6.1 Meter to 9 Meter Height Pole 20 Nos. 2500 50000 9 9
9.1 Meter to 11 Meter Height Pole 15 Nos. 3000 45000 9 9
11.1 Meter to 15 Meter Height Pole 4 Nos. 4500 18000 9 9
Servicing of Air-Conditioners (includes cleaning of blower condenser fan, cleaning of air filter with vacuum cleaner,
Evaporator coil, condenser coil and equipment,metallic/plastic body parts with soaked cotton cloths, Condenser ,Oil the
motor as and when required, Checking of Voltage stabilizers / Timers and remote control units to maintain these in healthy
158 conditions,Cleaning of Outdoor unit by Blower, Checking of working of compressor (Ampere of Compressor),Pressure 1500 Nos. 750000 9 9
checking of refrigerant,Checking the working of Stabilizer unit,Checking of working of Capacitors of outdoor
unit,Checking of drain pipe of outdoor unit, Checking the working of Flapper motor)
500
Supply and installation of capacitor for A.C compressor of 1.5 TR, 2 TR and 4TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
159 1.5 TR 17 Nos. 400 6800 9 9
2 TR 55 Nos. 450 24750 9 9
4 TR 3 Nos. 500 1500 9 9
Supply and installation of capacitor for fan motor of 1.5 TR, 2 TR and 4TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
160 1.5 TR 2 Nos. 150 300 9 9
2 TR 10 Nos. 180 1800 9 9
4 TR 1 Nos. 200 200 9 9
Supply and installation of thermostat switch of compressor for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
161 1 Nos. 500 9 9
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General 500
Supply and repalcing of faulty relay in compressor for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
162 1 Nos. 200 9 9
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General 200
Supply and repalcing of 3 way switch for 1.5 TR, 2 TR and 4TR AC as per OEM supply of
163 LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
1.5 TR, 2TR, 4 TR 1 Nos. 250 250 9 9
Supply and repalcing of outer cover for AC units for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
164 1.5 TR 1 Nos. 3000 3000 9 9
2 TR 1 Nos. 3500 3500 9 9
4 TR 1 Nos. 4000 4000 9 9
Supply and repalcing of front grill of Split A.Cof 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
165 1.5 TR 1 Nos. 3000 3000 9 9
2 TR 1 Nos. 3500 3500 9 9
4 TR 1 Nos. 4000 4000 9 9
Supply and installation of copper tubing for1.5 TR, 2 TR and 4 TR AC as per OEM supply of
166 LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
1.5 TR, 2TR, 4 TR 60 Mtr. 850 51000 9 9
Supply and repalcing of contactor coil for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
167 1.5 TR 4 Nos. 1500 6000 9 9
2 TR 25 Nos. 1800 45000 9 9
4 TR 1 Nos. 2500 2500 9 9
168 Reapairing of control curcuit of indoor AC unit up to 04 Ton 1 Nos. 3500 3500 9 9
169 Supply and installation of control curcuit unit from OEM of indoor AC unit up to 04 Ton 1 Nos. 10500 10500 9 9
Supply and installation of required Cu armoured cable for AC having capacity mentioned below:
170
1.5 TR, 2TR, 4 TR 80 Mtr. 300 24000 9 9
Supply and repalcing of Drain pipe of PVC for 1.5 TR, 2 TR, 2.5 TR, 5.5 TR and 8.5 TR AC
171
1.5 TR, 2TR, 4 TR 12 Mtr. 30 360 9 9
Supply and repalcing of Swing motor 12 V for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
172 1.5 TR 1 Nos. 750 750 9 9
2 TR 1 Nos. 850 850 9 9
4 TR 1 Nos. 1000 1000 9 9
Supply and repalcing of exhaust fan of outdoor unit for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
173 1.5 TR 3 Nos. 850 2550 9 9
2 TR 8 Nos. 950 7600 9 9
4 TR 1 Nos. 1000 1000 9 9
Supply and repalcing of flapper for indoor unit for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
174 1.5 TR 1 Nos. 700 700 9 9
2 TR 1 Nos. 850 850 9 9
4 TR 1 Nos. 1000 1000 9 9
Supply and repalcing of Air filter net for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
175 1.5 TR 1 Nos. 700 700 9 9
2 TR 1 Nos. 800 800 9 9
4 TR 1 Nos. 950 950 9 9
Supply and repalcing of insulation of AC duct from outdoor to indoor for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
176 80 Mtr. 20000 9 9
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General 250
Repairing,rewinding & re-installation of blower fan motor for 1.5 TR, 2 TR and 4 TR AC.This job includes removal of
faulty motor, repairing & rewinding and re-installation. No separate charges shall be paid for manpower, consumables,
bearings, equipments, tools & tackles used during execution of this activity.
177
1.5 TR 2 Nos. 1200 2400 9 9
2 TR 6 Nos. 1300 7800 9 9
4 TR 1 Nos. 1400 1400 9 9
Charging of refrigarant for 1.5 TR, 2 TR and 4 TR AC
1.5 TR 9 Nos. 2800 25200 9 9
178
2 TR 70 Nos. 3000 210000 9 9
4 TR 1 Nos. 4200 4200 9 9
Supply & Replacemet of condensor coil for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
179 1.5 TR 10 Nos. 11000 110000 9 9
2 TR 12 Nos. 11500 138000 9 9
4 TR 1 Nos. 14250 14250 9 9
Supply and repalcing of fan blade assembly of 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
180 1.5 TR 4 Nos. 750 3000 9 9
2 TR 10 Nos. 850 8500 9 9
4 TR 1 Nos. 950 950 9 9
Supply and replacement of motor assembly of indoor unit for 1.5 TR, 2 TR and 4 TR AC as per OEM supply of
LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar/Diakin/ Mitshubishi/ O'General
181 1.5 TR 4 Nos. 2600 10400 9 9
2 TR 15 Nos. 3000 45000 9 9
4 TR 1 Nos. 3400 3400 9 9
Shifting of A.C including gas charging, upto three meter copper tubing and civil work for 1.5 TR, 2 TR and 4 TR AC. The
job includes dismantling,handling, transportation, re-installation, testing & commissioning of A.C.Units. No separate
charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. Above
182 three meter copper tubing will be paid extra as per relevant SOR.
1.5 TR 6 Nos. 3200 19200 9 9
2 TR 18 Nos. 4000 72000 9 9
4 TR 1 Nos. 5000 5000 9 9
183 Reparing of stabilizer Upto 4 KVA 230 volt of Vinner , GRE, AB tronics make 4 Nos. 1000 4000 9 9
184 Reparing of stabilizer of from 5 KVA to 8 KVA 230 volt of Vinner , GRE, AB tronics make 1 Nos. 2500 2500 9 9
Supply and installation of the outdoor unit condensor body of AC of LG/Carrier, voltas , Blue-star/ONIDA/Hitachi/Diakin/
Mitshubishi/ O'General. The job includes dismantling of old one,re-installation of new one , testing & commissioning. No
separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this
185 activity.
1.5 TR 4 Nos. 4750 19000 9 9
2 TR 10 Nos. 5500 55000 9 9
4 TR 1 Nos. 7500 7500 9 9
Supply & installation of stabilizer Upto 4 KVA 230 volt of Vinner , GRE, AB tronics make,
186 1 Nos. 19000 9 9
It should be cu wound with overload tripping feature, voltmeter(digital) and MCB of GSPL approved vendor. 19000
Supply & installation of stabilizer from 5 KVA to 8 KVA 230 volt of Vinner , GRE, AB tronics make,
187 1 Nos. 23000 9 9
It should be cu wound with overload tripping feature, voltmeter(digital) and MCB of GSPL approved vendor. 23000
Supply of compressor having warranty of atleast one year for compressor and installation including gas charging for 1.5 & 2
188 TR Split AC as per OEM supply of LG/Carrier/ONIDA/Hitachi/Voltas. No separate charges shall be paid for manpower, 15 Nos. 146250 9 9
consumables, equipments, tools & tackles used during execution of this activity. 9750
Supply of compressor having warranty of atleast one year for compressor and installation including gas charging for 3-
Phase Split AC as per OEM supply of LG/Carrier/ONIDA/Voltas/Hitachi. No separate charges shall be paid for manpower,
189 consumables, equipments, tools & tackles used during execution of this activity.
4 TR 1 Nos. 12000 12000 9 9
Supply of compressor having warranty of atleast one year for compressor and installation including gas charging for 1.5
190 1 Nos. 17500 9 9
Window AC as per OEM supply of LG/Carrier/ONIDA/Hitachi/Voltas/Bluestar 17500
191 Reparing & Reinstalaltion of AC Timer Panel, including replacement of Timer PCB & Relays. 1 Nos. 2400 2400 9 9
192 Supply & installation of AC Timer Panel of Microprocessor based for Max 6 no of A.C Timer Operation. 1 Nos. 3750 3750 9 9
Supply & Installation of Faulty PCB of Indoor AC unit for 1.5 TR to 2.0 TR as per OEM supply of LG/Carrier/Onida
193 25 Nos. 46875 9 9
/Hitachi/VoltasMake/Bluestar/Diakin/ Mitshubishi/ O'General 1875
Supply & Instalaltion of Air Conditioner out door unit Bracket/Stand. The Job includes of installtion of required bracket in
194 12 Nos. 7200 9 9
wall with drill & suitable fastners. 600
Servicing of DG Sets as per rating mentioned below ( includes physical inspection, checking for damaged parts, repairing of
damaged parts, oil checking, trial run, synchronize checking, full load RPM checking, Voltage checking and adjustment,
Lube oil Checking, battery checking etc. with men, tools and tackles as required). Cost of spare parts replaced shall be paid
195 as per relevant SOR. No separate charges shall be paid for manpower, consumables, equipments, tools & tackles used
during execution of this activity.
upto 50 KVA 170 Nos. 3300 561000 9 9
51 to 125 KVA 20 Nos. 3800 76000 9 9
196 Supply and installation of Banjo hose for DG set up to 50 KVA 1 Nos. 670 670 9 9
197 Supply and Installation of KWH meters in DG set 1 Nos. 1800 1800 9 9
198 Supply and installation of Thermostat for DG set up to 50 KVA 1 Nos. 1200 1200 9 9
199 Supply and installation of Water temperature switch for DG set up to 50 KVA 1 Nos. 800 800 9 9
200 Supply and installation of Spin on Lube oil Filter for DG set up to 50 KVA 1 Nos. 500 500 9 9
201 Supply and installation of Spin on Diesel Filter for DG set up to 50 KVA 1 Nos. 500 500 9 9
202 Supply and installation of Battery Charger 12 V for DG set up to 50 KVA 1 Nos. 3500 3500 9 9
203 Supply and installation of Magnetic Pick-up coil for DG set up to 50 KVA 1 Nos. 5000 5000 9 9
204 Supply of Coolant for coolant cooled engines of Cummins/Kirloskar Make 1 Litres 100 100 9 9
205 Supply and Installation of DG Set Exhaust pipe Insulation (Rope) Coating 40 R. Mtr. 2500 100000 9 9
Repairing of the leaked Radiator of Diesel Generator Set for the Capacity from 51 to 125 KVA includes dismantling and
206 1 Nos. 3500 9 9
installation. 3500
Repairing of the leaked Radiator of Diesel Generator Set for the Capacity Upto 50 KVA includes dismantling and
207 1 Nos. 3500 9 9
installation. 3500
Supply & replacement of Automatic Voltage Regulator of crompton greaves /AVR-SR 7/3/SX-440 AVR of Cummins make
208 D.G set. No separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution 1 Nos. 12000 9 9
of this activity. 12000
209 Supply and Installation of Fuel Filter PRE Type of Kirloskar/Cummins/ Crompton Greaves Make 70 Nos. 600 42000 9 9
210 Supply of Fuel Filter MIC Type of Kirloskar/Cummins/ Crompton Greaves make 70 Nos. 600 42000 9 9
211 Supply of Lube Oil Filter Element of Kirloskar/Cummins/ Crompton Greaves Make 70 Nos. 800 56000 9 9
212 Supply of Air Filter of Kirloskar/Cummins/ Crompton Greaves Make 20 Nos. 1300 26000 9 9
213 Supply of Air Cleaner of Kirloskar/Cummins/ Crompton Greaves Make 20 Litres 1100 22000 9 9
Supply & replacement of "V"-Belt for blower of Kirloskar/Cummins/ Crompton Greaves/ A49 make. No separate charges
214 2 Nos. 1200 9 9
shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 600
Supply of & replacement "V"-Belt for dynamo of Kirloskar/Cummins/ Crompton Greaves /A45 make. No separate charges
215 9 Nos. 5400 9 9
shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 600
Supply & replacement of Bearing set of Kirloskar/Cummins/ Crompton Greaves make. No separate charges shall be paid
216 4 Nos. 3600 9 9
for manpower, consumables, equipments, tools & tackles used during execution of this activity. 900
Supply & replacement of Oil seal for crank of Kirloskar/Cummins/ Crompton Greaves make. No separate charges shall be
217 1 Nos. 1250 9 9
paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 1250
Supply & replacement of Steel Braided Diesel Pipe with/without banjo connection of Kirloskar make. No separate charges
218 40 Mtr. 20000 9 9
shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 500
219 Supply and replacement of engine oil of Kirloskar make / (20W40/15W40) 600 Litres 380 228000 9 9
Supply & replacement of Copper Washer set of Kirloskar/Cummins/ Crompton Greaves make. No separate charges shall
220 1 Nos. 700 9 9
be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 700
Supply & replacement of "O" ring set of Kirloskar/Cummins/ Crompton Greaves make. No separate charges shall be paid
221 1 Nos. 890 9 9
for manpower, consumables, equipments, tools & tackles used during execution of this activity. 890
Supply & Installation of Automatic Float-Boost charger of NHP Make Provided by M/s Kirloskar/Cummins/ Crompton
222 Greaves of 12V 6 Amp Rating. No separate charges shall be paid for manpower, consumables, equipments, tools & tackles 1 Nos. 4500 9 9
used during execution of this activity. 4500
Supply, removal of old battery & Installation of new 12V Lead-Acid Battery of Approved make for Invertor/ DG Set. No
separate charges shall be paid for manpower, consumables, equipments, tools & tackles, used during execution of this
activity. Contractor shall buyback the old battery.
150 Ah 20 Nos. 12000 240000 9 9
223
180 Ah 10 Nos. 13000 130000 9 9
97Ah 1 Nos. 11000 11000 9 9
135 Ah 1 Nos. 12500 12500 9 9
166 Ah 1 Nos. 14500 14500 9 9
Supply & Installation of 12V SMF Battery of Approved make. No separate charges shall be paid for manpower,
consumables, equipments, tools & tackles used during execution of this activity. Contractor shall buyback the old battery.
42 Ah 5 Nos. 10700 53500 9 9
224
65 Ah 1 Nos. 13500 13500 9 9
224
150 Ah 1 Nos. 22700 22700 9 9
180 Ah 1 Nos. 28890 28890 9 9

Servicing of Alternator of below mentioned rating DG sets, the job includes removal of oil and dirt accumulation, greasy
deposits on the windings should be wiped off with a lint free cloth dipped in petroleum solvent such as kerosene, petroleum
spirit to avoid short circuit. To check the condition of magnetic rotors & bearings, no-load and full-load test etc. No separate
225 charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity.

upto 50 KVA 1 Nos. 4200 4200 9 9


51 to 125 KVA 1 Nos. 5000 5000 9 9
Servicing of DG starter system. The Work involves checking of ignition start switch & magnetic switch, fuse between
ignition switch and 12 V battery, 12 V battery voltage and Sp. Gravity of battery water. Top-up of DM water in battery if
required.
226 Supply and replacement of bearings. 1 Nos. 1800 1800 9 9
Supply and replacement of magnetic rotors. 1 Nos. 3500 3500 9 9
Rewinding of Alternator upto 50 kVA . 1 Nos. 16000 16000 9 9
Rewinding of Alternator above 50 kv to 125 KVA 1 Nos. 25000 25000 9 9
Servicing of below mentioned electrical panel: The job shall include cleaning of the panel from outside and inside by
vaccum cleaner & Manual, checking of operation of MCCB/ACB/MCB, Indication Lamp, Meters
(KWh/Voltmeters/Ammeters/PF meters/FrequncyMeters etc.), Contactor, Fuses, CTs, Spacers etc. and sealing of the open
cable entries by PVC/GI blind plug . The job shall also include Identification, termination & proper Dressing of Cable. All
227 required tools, tackles, manpower and PVC/GI blind plug shall be in contractor's scope. The report submission in GSPL
approved format is also part of the job. The job shall be carried out by qualified electrician.
Only MEDB 75 Nos. 6000 450000 9 9
Other Panel except MEDB 150 Nos. 3500 525000 9 9
228 Supply and installation of Power contactors (65A-150A; UI=1000V). 1 Nos. 12500 12500 9 9
229 Supply & Replacement of Faulty Power Contactor coil (65A-150 A;UI=1000V) 1 Nos. 300 300 9 9
230 Supply & Replacement of Faulty Aux Contactor coil (For R,Y,B Phase Indication Contactor, 240 V Rating) 15 Nos. 600 9000 9 9
231 Supply & Replacement of Faulty Aux Contactor (For R,Y,B Phase Indication, 4A, 415/440 V Rating) 25 Nos. 850 21250 9 9
Supply and replacement of Current Transformer 1
CT Rasin Cast : CT ratio 100/1A, CL 5P20, VA 7.5 1 Nos. 3950 3950 9 9
CT Rasin Cast : CT ratio 100/1A, CL 1, VA 7.5 1 Nos. 1050 1050 9 9
CT Rasin Cast : CT ratio 75/1A, CL 5P20, VA 15 1 Nos. 4500 4500 9 9
CT Rasin Cast : CT ratio 75/1A, CL 1, VA 10 1 Nos. 1050 1050 9 9
232 CT Rasin Cast : CT ratio 75/1A, CL 5P20, VA 7.5 1 Nos. 3950 3950 9 9
CT Rasin Cast : CT ratio 75/1A, CL 1, VA 5 1 Nos. 980 980 9 9
CT Resin Cast : CT ratio 50/1A, CL 1, VA 5 1 Nos. 980 980 9 9
CT Tape Wound : CT ratio 50/1A, CL 5P20, VA 5 1 Nos. 2950 2950 9 9
CT Tape Wound : CT ratio 50/1A, CL 5P20, VA 15 1 Nos. 2950 2950 9 9
CT Tape Wound : CT ratio 50/1A, CL 1, VA 5 1 Nos. 750 750 9 9
Supply and replacement of Potential Transformer
233
PT ratio 415/110V, 50VA 1 Nos. 1200 1200 9 9
Supply and replacement of Analog/Digital Ammeters
CTR 75/1A Range 0-75A, Size 96 x 96 sq. mm. 1 Nos. 1500 1500 9 9
CTR 100/1A Range 0-100A, Size 96 x 96 sq. mm. 1 Nos. 1500 1500 9 9
234 CTR 50/1A, Range 0-50A, Size 96 x 96 sq. mm. 1 Nos. 1500 1500 9 9
CTR 50/1A, Range 0-50A, Size 72 x 72 sq. mm. 1 Nos. 1500 1500 9 9
DC 0-20A, 72 x 72 sq.mm 1 Nos. 1350 1350 9 9
DC 0-20 A, Size 96 x 96 sq. mm. 1 Nos. 1500 1500 9 9
Supply and replacement of Analog/Digital Voltmeters
AC 0-500 Volts, Size 96 x 96 sq. mm. 4 Nos. 1500 6000 9 9
AC 0-500 Volts, Size 72 x 72 sq. mm. 1 Nos. 1350 1350 9 9
235
DC 0-30 Volts, Size 96 x 96 sq. mm. 1 Nos. 1500 1500 9 9
DC 0-500 Volts, Size 96 x 96 sq. mm. 1 Nos. 1500 1500 9 9
DC 0-30 Volts, Size 72 x 72 sq. mm. 1 Nos. 1350 1350 9 9
Maintenance of cable trench and cable trays which involves cleaning by Vaccum Cleaner & manual, cable dressing, cable
236 identification etc.No separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during 1500 R. Mtr. 150000 9 9
execution of this activity. 100
Measurement of Insulation Resistance of Main-feeder cable (above 3C/4C X 25 sq.mm. ) during Plant shutdown time with
all required tools, tackles and skilled manpower
237 1 Per Cable 145 9 9
The job includes disconnection of termination at both ends & reconnection after completion of job.No separate charges shall
be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 145
Measurement of Insulation Resistance of cables below 3C/4C X 25 sq. mm.
238 The job includes disconnection of termination at both ends & reconnection after completion of job. No separate charges 1 Per Cable 220 9 9
shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 220
Preventive maintenance of switchgears 415 V, 250 A (involves cleaning of circuit breaker contacts and testing of relays). No
separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this 1 Nos. 1200 9 9
239 activity. 1200
Supply and top-up of breaker oil in case of MOCB. 1 Nos. 1300 1300 9 9
Supply and replacement of SF6 cylinder in case of SF6 breaker. 1 Nos. 1550 1550 9 9
Servicing and repair of 1250 VA inverter units for emergency lighting system. The works involves cleaning, to check the
condition of converter-rectifier units, DC capacitors, Batteries etc. of make "Keprej, Microtek, Sukam". No separate charges 1 Nos. 4500 9 9
shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 4500
240
Supply and installation of inverter upto 1600 VA of make Microtek/ Sukam/ Luminous 1 Nos. 40000 40000 9 9
Supply and Replacement of Converter-Rectifier unit. 4 Nos. 1200 4800 9 9
Supply and replacement of DC capacitor. 1 Nos. 850 850 9 9
Dismantling, powdercoating (Alkali Resistant Epoxy Powder Coated , Shade:RAL 7032) & reassembling of Ni-CD Battery
Rack. Work includes Surface Cleaning of batteries with DM water & potential measurement of each cell voltage after
241 15 Nos. 82500 9 9
reassembling. No separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during
execution of this activity. 5500
Ni-CD Battery Bank maintenance including cleaning of battery by removing each cells from battery racks, dust/ corrosion
removal from terminals & battery cells, Specific Gravity Checking, Water level checking & refilling of DM water (if
required), application of petrolium jelly on each battery terminal & links as per instruction of Engineer In charge. All
242 55000 Per Battery 1430000 9 9
required tools tackles like hydrometer, insulated spanners, etc., PPEs, DM water & other consumable are in the scope of
contractor . No separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during
execution of this activity. 26

Stenciling & Painting of numbers/ letters/ logos/ arrow etc including supply of fluorescent/ highlighted paint/ acrylic
243 emulsion/ oil paint of approved brand as per the approved vendor list given in tender and quality wherever required as per 250 Sq. Mtr. 287500 9 9
directed by GSPL E-I-C: Area of the Stenciling & Painting shall be calculated on the basis of length & width of words.
1150
Supply and filling of bentonite slurry in pipe conduits. The Job includes excavation upto the underground vent pipe, opening
of vent pipe if required, sealing of vent pipe after bentonite filling, backfilling, provision of all required manpower,
244 machinery, bentonite, water and power etc., for complete job and as per instruction of EIC. No separate charges shall be 6 Cu. Mtr. 30000 9 9
paid for excavation, backfilling, cutting & welding of vent pipe, manpower, consumables, equipments, tools & tackles used
during execution of this activity. 5000

Load testing of EOT/Mono Rails of various capacities in presence of competent authority including supply of dead weight
block of required capacity and submission of certificates. The job includes examination and testing of lifting tools and
tackles as per Factories Act,1948 and providing certificate in FORM No:10 (Prescribed under rule 60) by competent person
who has certificate possessing by issued Factory Inspector . Tested date, safe working load, due date etc shall be written on
the equipment at end of testing as per instruction of Engineer In-Charge. No separate charges shall be paid for manpower,
245 consumables,lifting equipments, transportation of test load, tools & tackles used during execution of this activity.

up to 2 Tonne 1 Nos. 4500 4500 9 9


up to 5 Tonne 3 Nos. 8000 24000 9 9
up to 10 Tonne 1 Nos. 11000 11000 9 9
up to 15 Tonne 1 Nos. 15000 15000 9 9

Hydro testing of Launcher/Receiver, Filters as per GSPL Requirements( Test Pressure- 150 Barg, Holding period - Min 4
Hours). Test includes Complete hydrostatic test arrangement i.e. test facilities with high pressure hose pipe, Calibrated
digital pressure gauge, pressure recorder & chart, suitable manifold and any special requirement to conduct the hydrostatic
test at site location and submission of reports. Required Valve operation, blinding if required, removal of filter elements, re-
installation of filter elements after completion of Hydro- test. No separate charges shall be paid for manpower,
consumables,lifting equipments,water, tools & tackles used during execution of this activity. The job includes examination
and testing of pressure vessel as per Factories Act 1948 and providing certificate in FORM No:11 (Prescribed under rule 61)
by competent person who has certificate possessing by issued Factory Inspector . Tested date, Test Pressure, due date etc
246 shall be written on the equipment at end of testing as per instruction of Engineer In-Charge.

Launcher/ Receiver Barrel size upto - 18" dia 1 Nos. 8900 8900 9 9
Launcher/ Receiver barrel size from 20" to - 36" dia 1 Nos. 15000 15000 9 9
Launcher/ Receiver barrel size 40" dia 1 Nos. 20000 20000 9 9
upto 12" dia size Filter 1 Nos. 14500 14500 9 9
14" to 20" dia size Filter 1 Nos. 17500 17500 9 9
24" to 30" dia size Filter 1 Nos. 20500 20500 9 9
36" to 60" dia size Filter 1 Nos. 20500 20500 9 9
247 Visual inspection & Certfications of filter as per factory act through approved competent person. 1 Nos. 6500 6500 9 9
Pneumatic testing of Launcher/Receiver, Filters as per GSPL Requirements Test Pressure shall be 1.1 times of design
pressure (MAOP), holding period- Min 30 minutes. Test includes Complete Pneumatic test arrangement i.e. test facilities
with high pressure hose pipe, Calibrated digital pressure gauge, suitable manifold and any special requirement to conduct
the Pneumatic test at site location and submission of reports. Required Valve operation, blinding if required, removal of
filter elements, re-installation of filter elements after completion of Pneumatic Test. No separate charges shall be paid for
manpower, consumables,lifting equipments,Nitrogen, tools & tackles used during execution of this activity. Positive
isolation of connected piping system to the equipments to be tested, if required.
248
Launcher/ Receiver Barrel size upto - 18" dia 1 Nos. 22000 22000 9 9
Launcher/ Receiver barrel size from 20" to - 36" dia 1 Nos. 30000 30000 9 9
Launcher/ Receiver barrel size 40" dia 1 Nos. 35000 35000 9 9
upto 12" dia size Filter 2 Nos. 22000 44000 9 9
14" to 20" dia size Filter 2 Nos. 30000 60000 9 9
24" to 30" dia size Filter 1 Nos. 40000 40000 9 9
36" to 60" dia size Filter 1 Nos. 45000 45000 9 9
Hydrostatic testing of Nitrogen cylinder/ Co2 Flooding cylinder / pilot cylinder as per Latest Gas Cylinder Rules from
authorized agency/Vendor. Hydrotesting of cylinders at vendor shop/Factory to be carried-out with high pressure hose pipe,
calibrated digital pressure gauge, pressure recorder & chart, suitable manifold with fittings and any special requirement.
Dismantling, loading, unloading, to and fro transportation, re-filling, re-installation shall paid as per relevant SOR. No
249 separate charges shall be paid for manpower, consumables,lifting equipments, tools & tackles used during execution of this
activity.
CO2 Flooding cylinder - Water Capacity:68 Litress 20 Nos. 2900 58000 9 9
Nitrogen Gas pilot cylinder - water capacity : 6.8Litress 1 Nos. 2900 2900 9 9
Nitrogen Gas cylinder- water capacity : 48Litress 10 Nos. 2900 29000 9 9
Hydrostatic testing of double length Line Pipe( approx. 24 meter) at max. pressure of 150 brag. Job includes arrangement of
Header/ Dish end (end cap) for installation of calibrated pressure gauge, water inlet, drain, vent; welding,NDT, cutting,
bevelling and edge preparation after testig job. Submission of report after completion of hydrotest.This includes
loading/unloading of linepipe, header/disc end preparation, tools, tackels, water, Pump, corrosion inhibitor, equipment,
manpower, etc. required for execution of job.
6"NB 2 Nos. 20000 40000 9 9
250 8"NB 2 Nos. 30000 60000 9 9
12"NB 2 Nos. 40000 80000 9 9
16"NB 2 Nos. 50000 100000 9 9
18"NB 2 Nos. 70000 140000 9 9
24"NB 2 Nos. 90000 180000 9 9
30"NB 2 Nos. 105000 210000 9 9
36"NB 2 Nos. 110000 220000 9 9
Hiring of following equipments for doing any emergency work with all required valid test certificates. The period of hiring
will start after the equipment reaches at site and ends when equipment leaves the site. Break down period of equipment will
not be paid. Normal working time per day will be 8 Hrs. Rate for idle time shall be 50%. Night is not included in idle time
except if works will continue in night. Hiring rates is inclusive of diesel, operators, maintenance cost, loading/unloading of
equipments by Hydra/manual at site.
Dewatering pump of capacity 20KL with required capacity D.G.Set 30 Per Hour 400 12000 9 9
Diaphragm pump of capacity 20KL with required capacity D.G.Set 1 Per Hour 400 400 9 9
Air Compressor of capacity 100-240CFM with required capacity D.G.Set 1 Per Hour 590 590 9 9
251 Air Compressor of capacity 75 CFM with required capacity D.G.Set 2 Per Hour 400 800 9 9
Hydra of lifting capacity 10MT to 15 MT along with required wire ropes & D-Shackle 300 Per Hour 1450 435000 9 9
Crane of capacity 20MT along with required wire ropes & D-Shackle 6 Per Hour 3000 18000 9 9
Crane of capacity up to 50MT along with required wire ropes & D-Shackle 1 Per Hour 3500 3500 9 9
Plate - compactor 1 Per Hour 250 250 9 9
15KVA DG set: 10 Per Hour 630 6300 9 9
JCB 125 Per Hour 1100 137500 9 9
Back-hoe With Rock Breaker 1 Per Hour 3900 3900 9 9
Tractor Mounted Pneumatic Type Rock Breaker 1 Per Hour 3500 3500 9 9
Schedule of rates for extra works for manpower supply
Qualified Welder 30 1400 42000 9 9
Fitter/Grinder 150 950 142500 9 9
Electrician/ Wireman 350 1100 385000 9 9
Per 8 Hr.
Instrument Technician / Tubing Fitter 550 1170 643500 9 9
252
Rigger 700 850 595000 9 9
Helper/Unskilled Labour 1650 600 990000 9 9
Plumber 1 Per 8 Hr. 1600 1600 9 9
Mason 1 Per 8 Hr. 1800 1800 9 9
Carpenter 1 Per 8 Hr. 1800 1800 9 9
Updation of As-Built drawings like P&ID, GAD, Plot Plan, ISO, Alignment Sheet etc. (including taking of required
253 1 Per Drawing 25000 9 9
measurement from Site) after modifications. 25000
Preparation of Engineering Drawings such as P&ID, GAD, HAC, ISO, Plotplan, Alignment Sheets, Crossing Drawings, etc
254 (including taking of required measurement from Site). Final approved copy of drawing along with submission of editable 1 Per Drawing 25000 9 9
Auto-Cad file and one printed copy in A2 size shall be entitled for redemption of this SoR 25000
Checking & Maintenance of Instrument Panel: The job shall include cleaning of the panel from outside and inside by
vaccum cleaner / Manual, checking of Indication Lamp, Hooter, Fuses, and sealing of the open cable entries by PVC/GI
255 blind plug . The job shall also include Identification, termination & proper Dressing of Cable. All required tools, tackles, 20 Nos. 60000 9 9
manpower and PVC/GI blind plug shall be in contractor's scope. The report submission in GSPL approved format is also
part of the job. The job shall be caarried out by qualified instrument technician /electrician. 3000
Supply & Installation of GSPL approved makes Cooling/Ventilation fan along with safety grill and dust preventor in
control panel 4” axial fan 220V Ball baring
256
Size : 4” axial fan 220V Ball baring with finger guard 10 Nos. 1500 15000 9 9
Size : 6” axial fan 220V Ball baring with finger guard 1 Nos. 1900 1900 9 9
257 Supply of panel cover for modular piano switches of different sizes 1 Nos. 650 650 9 9
Supply & Replacement of door hinges in instrument local control panel / RTU panel / DCIU panel, Make: Rittal. The job
258 18 Nos. 18000 9 9
shall be caarried out by qualified instrument technician /electrician. 1000
Supply & Replacement of door Lock in instrument local control panel / RTU panel / DCIU panel/Electrical panels, Make:
259 35 Nos. 10500 9 9
Rittal. The job shall be caarried out by qualified instrument technician /electrician. 300
Supply & Replacement of GSPL approved make Tube light including lamp,choke and fixure for panel door in instrument
260 local control panel / RTU panel / DCIU panel, Make: Rittal. The job shall be caarried out by qualified instrument technician 3 Nos. 1200 9 9
/electrician. 400
Supply & Replacement of GSPL approved make Selector switch in Instrument local control panel.The job shall be caarried
261 1 Nos. 650 9 9
out by qualified instrument technician /electrician. 650
Supply & Replacement of GSPL approved make Panel Hooter, Supply Voltage 230Vac / 24 Vdc as per GSPL requirement
262 1 Nos. 1200 9 9
for instrument panel and F & G and CO2 flooding system 1200
Supply & Replacement of GSPL approved make FLP & WP Field Hooter , Supply Voltage 230Vac / 24 Vdc as per GSPL
263 3 Nos. 12000 9 9
requirement for Gas Detection System. 4000
Supply & Replacement of GSPL approved make i.e. Sudhir Switchgear - FLP & WP Flasher (Yellow/Red) , Supply Voltage
264 6 Nos. 39000 9 9
230Vac / 24 Vdc as per GSPL requirement for Gas Detection System. 6500
Supply & Replacement of Point gas Detector GSPL approved make & model Crowcon XgardIR and Det-tronics PIRECL/
265 other approved make with control card and full intregration as per the given specification by EIC and as per GSPL 1 Nos. 125000 9 9
requirement for Gas Detection System. 125000
Supply & replacement of Interconnecting Hose Pipe 1/4" dia for CO2 Cylinder , Make: GSPL approved vendor. Hose pipe
266 1 Nos. 780 9 9
hydrotest certificate to be submitted. 780
Supply & replacement of Electrical Weight indicator Actuator on Co2 Cylinder with interconnection cable with adapter,
267 3 Nos. 4500 9 9
Make:GSPL approved vendor 1500
268 Supply & replacement of Manual call point, Make:GSPL approved vendor 1 Nos. 850 850 9 9
269 Supply & replacement of Electrical Fire Exit Glow Board, Make:GSPL approved vendor 1 Nos. 2500 2500 9 9
270 Supply & Replacement of Power Supply Converter, 230 Vac to 24 Vdc, 10A approved makes : GSPL approved vendor 1 Nos. 1500 9 9
1500
271 Supply of solenoid valve of Kirloskar/Cummins/ Crompton Greaves Make 1 Nos. 9500 9500 9 9
272 Supply & installation of floating mechanical fuel gauge on fuel tank of Kirloskar/Cummins/ Crompton Greaves Make 1 Nos. 2250 2250 9 9
273 Supply and replacement of display of Kirloskar/Cummins/ Crompton Greaves Make 1 Nos. 5500 5500 9 9
274 Repairing of display panel and programming of Kirloskar/Cummins/ Crompton Greaves Make 1 Nos. 12500 12500 9 9
275 Supply and replacement of ignition key of Kirloskar/Cummins/ Crompton Greaves Make 1 Nos. 1750 1750 9 9
276 Supply and installation of door hinges and locks for DG set canopy 1 Nos. 1400 1400 9 9
277 Repair of 12 V DG battery charger 1 Nos. 1800 1800 9 9
Supply and replacement of Gland packings of Globe Valves (from 2" to 10"). Gland Packing to be purchase from GSPL
278 10 Nos. 15000 9 9
Approved Vendor/OEM of Valve. 1500
Supply and installation of caution board/danger notice on electrical panel as per IS 2551 having skull and bone sign with
279 1 Nos. 450 9 9
volatage level. 450

Servicing & Maintenance of EOT Crane (Overhead Crane) of capacity mentioned below for General Servicing & checking
of Long Travel, Cross Travel & Hoist Mechanism including following activities
1) Checking of Travelling speed for LT,CT & Hoist.
2) Checking the condition of Main Hoist Wire Rope
3) Operational check for Gear box of LT,CT & Hoist to check the condition of Gears & Oil.
4) Cleaning & checking of Girder
280 5) Checking of Brake Disc/Brake Pads/Brake Liners
6) Checking of Push Button Controls, Operation of Motors, Variable Frequency Drives (VFD), Limit Switches, Breaking
Resistors & Bus Bars. No separate charges shall be paid for manpower, consumables, tools & tackles used during execution
of this activity.

5 Ton 1 Nos. 20000 20000 9 9


10 Ton 1 Nos. 25000 25000 9 9
Supply of DM water as per the requirement at designated store. Transporation, manpower and containers are in contractor's
281 1 Litres 62 9 9
scope. 62
Operation of 125 KVA, 2 Nos. D.G sets on round the clock basis by placing at least three experienced personnel and
282 12 Per Month 660000 9 9
maintain hourly logs, D.G. sets dialy checks, diesel filling, water filling as per EIC requirement 55000
283 Supply and installation of Hot insulation with GI cladding by filling glass wool as per EIC requirement. 1 Sq. Mtr. 4000 4000 9 9
284 Overhauling of the jockey Centrifugal pump (01 Nos.) and Main centrifugal pump (02 Nos.) of the Fire hydrant system. 1 Nos. 19005 19005 9 9
Supply & installation of FRP sheet as per thickness mentioned below of approved colour on roofing and sides of Metering
system or DG Sets as per manufacturer’s instructions including providing sealant in the overlapping portion of sheets 1
complete and including all accessories.
285 3 MM 20 SQ FT 120 2400 9 9
5 MM 1 SQ FT 500 500 9 9
8 MM 1 SQ FT 600 600 9 9
10 MM 1 SQ FT 800 800 9 9
Supply & Installation of different type of TLP units. This includes Transportation, Cable termination and Jointing, Tagging,
Excavation, Civil work, Jointing with old cables with epoxy hardener.
A 15 Nos. 20000 300000 9 9
B 2 Nos. 25000 50000 9 9
286 C 2 Nos. 20000 40000 9 9
D 5 Nos. 20000 100000 9 9
E 1 Nos. 25000 25000 9 9
H 1 Nos. 25000 25000 9 9
I 1 Nos. 10000 10000 9 9
Pin brazing for CP system, job includes removal of coating, pipe surface preparation, supply & installation of Cable,
materials, consumbles (epoxy hardener application, etc.), manpower, equipments. Job also includes excavation up to
287 20 Nos. 100000 9 9
pipleine depth of maxium of 5.5 meters in case pipe is under ground and locate the point, dewatering, backfilling,
restoration. 5000
Removal and Re-installation of Turbine Meter of size mentioned below, Profiler Plate, Spool Piece Between Profiler Plate
to Meter , Upstream Spool Piece of Profiler, Spool Piece between Meter and Metering Temperature Measurement. No
separate charges shall be paid for manpower, consumables,lifting equipments, valve operations, tools & tackles used during
288 execution of this activity. Gasket shall be supplied by GSPL at designated store.
2" 1 Nos. 1200 1200 9 9
3" 1 Nos. 1200 1200 9 9
Removal and Re-installation of Senior Orifice Meter of size mentioned below, Profiler Plate , Spool Piece Between Profiler
Plate to Meter , Upstream Spool Piece of Profiler , Spool Piece between Meter and Metering Temperature Measurement.
No separate charges shall be paid for manpower, consumables,lifting equipments, valve operations, tools & tackles used
289 during execution of this activity. Gasket shall be supplied by GSPL at designated store.
2" 1 Nos. 1400 1400 9 9
3" 1 Nos. 1400 1400 9 9
Removal and Re-installation of Ultrasonic Meter of size mentioned below , Profiler Plate , Spool Piece Between Profiler
Plate to Meter , Upstream Spool Piece of Profiler , Spool Piece between Meter and Metering Temperature Measurement.
No separate charges shall be paid for manpower, consumables,lifting equipments, valve operations, tools & tackles used
during execution of this activity. Gasket shall be supplied by GSPL at designated store.
4" 1 Nos. 1200 1200 9 9
290
6" 4 Nos. 2400 9600 9 9
8" 1 Nos. 4980 4980 9 9
10" 1 Nos. 4980 4980 9 9
12" 1 Nos. 6300 6300 9 9
16" 1 Nos. 6300 6300 9 9
Removal and Re-installation of Turbine Meter of size mentioned below. No separate charges shall be paid for manpower,
consumables,lifting equipments, valve operations, tools & tackles used during execution of this activity. Gasket shall be
291 supplied by GSPL at designated store.
2" 1 Nos. 1190 1190 9 9
3" 1 Nos. 1190 1190 9 9
Removal and Re-installation of Ultrasonic Meter of size mentioned below. No separate charges shall be paid for
manpower, consumables,lifting equipments, valve operations, tools & tackles used during execution of this activity. Gasket
shall be supplied by GSPL at designated store.
4" 1 Nos. 2400 2400 9 9
292 6" 1 Nos. 3100 3100 9 9
8" 1 Nos. 3800 3800 9 9
10" 1 Nos. 4400 4400 9 9
12" 1 Nos. 5000 5000 9 9
16" 1 Nos. 5500 5500 9 9
Removal and Re-installation of Regulator Valve ( Either Active or Monitor) of size mentioned below. Size of regulator
valve to be considered as per Inlet size of Regulator. No separate charges shall be paid for manpower, consumables,lifting
equipments, tools & tackles used during execution of this activity. Gasket shall be supplied by GSPL at designated store.

1" 1 Nos. 2500 2500 9 9


293 1.5" 1 Nos. 2500 2500 9 9
2" 1 Nos. 3000 3000 9 9
2.5" 1 Nos. 3500 3500 9 9
3" 1 Nos. 4000 4000 9 9
4" 1 Nos. 5500 5500 9 9
6" 4 Nos. 6000 24000 9 9
Removal and Re-installation of SSV Valve of size mentioned below. No separate charges shall be paid for manpower,
consumables,lifting equipments, tools & tackles used during execution of this activity. Gasket shall be supplied by GSPL at
designated store.
1" 1 Nos. 2500 2500 9 9
1.5" 1 Nos. 2500 2500 9 9
2" 1 Nos. 3000 3000 9 9
294
2.5" 1 Nos. 3500 3500 9 9
3" 1 Nos. 4000 4000 9 9
4" 1 Nos. 5500 5500 9 9
6" 1 Nos. 6000 6000 9 9
8" 1 Nos. 7000 7000 9 9
10" 1 Nos. 7500 7500 9 9
Removal and Re-installation of Flow Control Valve of size mentioned below. No separate charges shall be paid for
manpower, consumables,lifting equipments, tools & tackles used during execution of this activity. Gasket shall be supplied
by GSPL at designated store.
1" 1 Nos. 990 990 9 9
1.5" 1 Nos. 990 990 9 9
2" 1 Nos. 990 990 9 9
295
3" 1 Nos. 1090 1090 9 9
4" 1 Nos. 2200 2200 9 9
6" 1 Nos. 3000 3000 9 9
8" 1 Nos. 3500 3500 9 9
10" 1 Nos. 4300 4300 9 9
12" 1 Nos. 5000 5000 9 9
Supply, fabrication and installtion of Vent line Flapper(Brass) with perforated wiremesh in Brass material. The Job includes
dismantle the vent pipe and refitting as found position after fabrication. No seperate charges shall be paid for manpower,
dismantling spool, welding and refitting the same. Cosumable like Gasket shall be provided by GSPL
Upto 2" 1 Nos. 3000 3000 9 9
3" 1 Nos. 4000 4000 9 9
296 4" 1 Nos. 5000 5000 9 9
6" 1 Nos. 6000 6000 9 9
8" 1 Nos. 7000 7000 9 9
10" 1 Nos. 10000 10000 9 9
12" 1 Nos. 12000 12000 9 9
16" 1 Nos. 14000 14000 9 9
Supply and installtion of Vent line Flapper(Brass material). The Job includes instalation of flapper in propser position. No
seperate charges shall be paid for manpower.
Upto 2" 1 Nos. 2400 2400 9 9
3" 1 Nos. 3000 3000 9 9
4" 1 Nos. 4000 4000 9 9
297 6" 1 Nos. 5000 5000 9 9
8" 1 Nos. 6000 6000 9 9
10" 1 Nos. 8000 8000 9 9
12" 1 Nos. 10000 10000 9 9
16" 1 Nos. 13000 13000 9 9
1
Cold Cutting Activity for Joint/Pipe of different sizes. This inclides all tools, tackels, consumables, equipment, manpower,
etc. to perform this job.
Up to 3" 1 Inch. Dia. 5000 5000 9 9
4" 1 Inch. Dia. 5000 5000 9 9
6" 1 Inch. Dia. 5500 5500 9 9
8" 1 Inch. Dia. 5500 5500 9 9
298
298
12" 1 Inch. Dia. 6000 6000 9 9
16" 1 Inch. Dia. 6500 6500 9 9
18" 1 Inch. Dia. 7000 7000 9 9
24" 1 Inch. Dia. 7500 7500 9 9
30" 1 Inch. Dia. 8000 8000 9 9
36" 1 Inch. Dia. 8500 8500 9 9
Removal and Re Fitment of Spool Piece between Profiler Plate to Meter of size mentioned below.No separate charges shall
be paid for manpower, consumables,lifting equipments, valve operations, tools & tackles used during execution of this
activity. Gasket shall be supplied by GSPL at designated store.
2" 1 Nos. 1400 1400 9 9
3" 1 Nos. 2000 2000 9 9
299 4" 1 Nos. 2900 2900 9 9
6" 1 Nos. 7000 7000 9 9
8" 1 Nos. 7000 7000 9 9
10" 1 Nos. 12000 12000 9 9
12" 1 Nos. 12000 12000 9 9
16" 1 Nos. 12000 12000 9 9
300 Maintenance of Solar Lights. 1 Nos. 2000 2000 9 9
Supply and replacement of solar light spares
Solar Module
(Vikram Solar, Waree Solar,Goldi green technologies pvt ltd, Tata power solar systems pvt.ltd, Solar systmes pvt.ltd, Moser
1 Nos. 55000 9 9
bear solar limited, XL energy limited, Solar semiconductor, Emmvee photovoltaics pvt ltd ,Navitas green solutions pvt ltd,
301 Satvik, Panchwakr solar, Surana solar) 55000
Photovoltaic Battery 12V 150AH
1 Nos. 20000 9 9
( Exide, Okaya, Luminous, Relicell, Artheon, Su-kam, base, Southern, HBL, Gem) 20000
Charge Controller
1 Nos. 4500 9 9
(Systeller, Flin energy, SuKam, UTL Inverter, Luminous) 4500
LED Street light Fixtures Solar Lighting Poles
(Philips, Crompton, Wipro, Havells, Oreva, Charlson, Syska, Moser bear, Surya, Bajaj)
LED Luminarie Fixture 09 -12 Watts 1 Nos. 1800 1800 9 9
LED Luminarie Fixture 18 - 24 Watts 1 Nos. 2400 2400 9 9
LED Luminarie Fixture 30 - 43 Watts 1 Nos. 5100 5100 9 9
Approved make PCB for LED Luminarie Fixture 09 -12 Watts 1 Nos. 300 300 9 9
302 Approved make PCB for LED Luminarie Fixture 18 - 24 Watts 1 Nos. 500 500 9 9
Approved make PCB for LED Luminarie Fixture 30 - 43 Watts 1 Nos. 700 700 9 9
Approved make 12 Volt SMPS for LED Luminarie Fixture 09 -12 Watts 1 Nos. 1500 1500 9 9
Approved make 12 Volt SMPS for LED Luminarie Fixture 18 - 24 Watts 1 Nos. 2000 2000 9 9
Approved make 12 Volt SMPS for LED Luminarie Fixture 30 - 43 Watts 1 Nos. 2500 2500 9 9
Poweder Coated Battery Box 1 Nos. 8100 8100 9 9
Supply, Laying & Terminaltion of 2C x 4 Sq. mm armored power cable 1 R. Mtr. 350 350 9 9
Supply & Installation (Including removal of existing one) of Ni-CD Battery (NCPP/ VRPP) 1.2 V for UPS system
NCCP 1.2 Volt, 52 AH 1 Nos. 3000 3000 9 9
NCCP 1.2 Volt, 100AH 1 Nos. 6000 6000 9 9
303 NCCP 1.2 Volt, 135AH 1 Nos. 10000 10000 9 9
VRPP 1.2 Volt, 166AH 1 Nos. 12000 12000 9 9
NCCP 1.2 Volt, 145AH 1 Nos. 13000 13000 9 9
VRPP 1.2 Volt, 555AH 1 Nos. 25000 25000 9 9
304 PAUT Testing as per instruction of EIC and submission of report 1 Location 24000 24000 9 9
CP Monitoring
PSP & TLP Monitering through Data Logger ( atleast 1 TLP/ KM) 2700 Per Kms 725 1957500 9 9
CIPL Survey 1 Per Kms 5500 5500 9 9
DCVG Survey 1 Per Kms 5500 5500 9 9
CAT Survey 1 Per Kms 5500 5500 9 9
AC/DC survey 1 Location 4000 4000 9 9
305 Software modelling for AC/DC interference survey 1 Per Kms 250000 250000 9 9
ON/OFF Potential Survey 1 Per Kms 1500 1500 9 9
TR Unit Preventive Maintenance 1 Nos. 12000 12000 9 9
Monitoring & Preventive Maintenance of AGB 1 Location 15000 15000 9 9
TR Unit Meter Calibration 1 Location 3000 3000 9 9
Foreign Pipeline crossing survey 1 Location 4000 4000 9 9
ER Probe/CTSU/Corrosion coupon monitoring 1 Location 2000 2000 9 9
Dismantling of exisitng battery & re-installation of the same after charging
306 1 Nos. 400 9 9
(for battery of DG, Inverter, Solar etc.) 400
307 Supply and Installation of Pre cast Cable Route Marker (For Instrumentation and Electrical cables) 1 Nos. 700 700 9 9
Preparation of cable schedule and termination detailing of existing cables of all panels (E&I, Telecom, Metering,
308 Scada, EPABX, CCTV, GC, etc.) the job is to be executed as per the direction of the GSPL E.I.C. & GSPL 1 per panel 7500 9 9
requirement. 7500
Relocation of panel (Base frame Mounted)- Isolation of the existing panels by Dismantling/ Disconnection of cables,
earthings, tag-weldings etc as to make them fully isolated from the existing setUp and shifting & erection of panels on
MS frame at new location,the job is to be executed as per the direction of the GSPL E.I.C. & GSPL requirement
309 8 per panel 160000 9 9
(separate charges shall be paid for MS steel frame & earthing connectivity as per relevent SOR SOR). The size of
floor mounted panel shall be up to 2100 X 1000 X 1200 (HxDxW) (in mm). The maximum weight shall be consider
up to 2 tons. 20000
Relocation of panel (wall mounted) - Isolation of the existing panels by Dismantling/ Disconnection of cables,
earthings, tag-weldings etc as to make them fully isolated from the existing setUp and shifting & erection of panels on
310 wall or on vertical steel frame at new location.the job is to be executed as per the direction of the GSPL E.I.C. & GSPL 10 per panel 100000 9 9
requirement (separate charges shall be paid for MS steel frame as per relevent SOR). The maximum weight shall be
up to 400 Kg. 10000

Supply, transportation, fabrication and erection of MS steel section (Frame) of various sizes along with required
fasteners (plate, angle, tee, channel, beam etc) for installation of panel. Rate also includes the surface cleaning by a
suitable method, Supply and application of two coat of high build chlorinated rubber / zinc phosphate primer and two
311 coats of finished paint of epoxy of grey colour / colour as specified by GSPL of approved make, the job is to be 1000 per Kg 170000 9 9
executed as per the direction of the GSPL E.I.C. & GSPL requirement. Job inclusive of labour, machinery etc.(No
separate charges shall be paid for transportation of fabricated structure, manpower, equipemnts used during execution
of this activity)
170

Existing Cable to be shifted with panel- Isolation, disconnection, removal of all signal, power, Ethernet & fiber cables
from existing panel at existing location and re-routing of same cable to new panel location by proper cable laying on
cable tray , Cable dressing on cable tray and in panel,Cable glanding, termination in same panel at new location as per
cable schedule and termination detailing prepared by contractor.The rates shall include the Supply and fixing of cable
tags at both end , G.I. saddles / clamps, PVC/HDPE flexible conduit, saddle bars, lugs, ferrules, RJ45 & RJ11
connector for eathernet and telecom cable,Fiber ST/SC/LC/FC connector including crimping, including transportation
with all labor and materials as per the specifications, drawings and directions of Engineer-in-charge . No separate
charges shall be paid for manpower,consumables, tools & tackles used during execution of this activity. Cable joint is
not allowed. Replace all shorts cable as per cable schedule. (Seprate charges shall be paid for Supply of cable,Cable
gland, Cable tray and 24 Core OFC splicing and termination as per relevent SOR)job is to be executed as per the
direction of the GSPL E.I.C. & GSPL requirement

Up to 3 core x 25 sqmm power cable 1 per No 600 600 9 9


Up to 3 core x 6 sqmm power cable 1 per No 300 300 9 9
312
Up to 3 Core x 2.5 sqmm power cable 1 per No 200 200 9 9
2 Core x 2.5 sqmm power cable 1 per No 200 200 9 9
2 core x 1.5 sqmm power cable 1 per No 200 200 9 9
Up to 1 sqmm control cable 1 per No 200 200 9 9
Up to 2 pair x 1.5 sqmm instrument cable 1 per No 200 200 9 9
Up to 6 pair x 1.5 sqmm instrument cable 1 per No 300 300 9 9
Up to 12 pair x 1.5 sqmm instrument cable 1 per No 350 350 9 9
Up to 8 traid x 1.5 sqmm cable 1 per No 300 300 9 9
CAT 6 Eathernet cable 1 per No 200 200 9 9
Optical Fiber Patch chord - 1 pair - Up to 25 meter 1 per No 200 200 9 9
24 Core OFC cable 1 per No 300 300 9 9
Video Cable 1 per No 200 200 9 9
Earthing Cable Up to 25 sqmm 1 per No 200 200 9 9

Existing Cable (not shifted)- Proper cable laying on cable tray, Cable dressing on cable tray and in panel as per cable
schedule and termination detailing prepared by contractor.The rates shall include the Supply and fixing of cable tags at
both end , G.I. saddles / clamps, PVC/HDPE flexible conduit, saddle bars, lugs, ferrules, RJ45 & RJ11 connector for
eathernet and telecom cable,Fiber ST/SC/LC/FC connector including crimping etc, including transportation with all
labor and materials as per the specifications, drawings and directions of Engineer-in-charge . No separate charges shall
be paid for manpower,consumables, tools & tackles used during execution of this activity. (Seprate charges shall be
paid for Supply Cable tray as per relevent SOR)job is to be executed as per the direction of the GSPL E.I.C. & GSPL
requirement

Up to 3 core x 25 sqmm 1 per No 600 600 9 9

313
Up to 3 core x 6 sqmm power cable 1 per No 300 300 9 9
313 Up to 3 Core x 2.5 sqmm power cable 1 per No 200 200 9 9
2 Core x 2.5 sqmm power cable 1 per No 200 200 9 9
2 core x 1.5 sqmm power cable 1 per No 200 200 9 9
Up to 1 sqmm control cable 1 per No 200 200 9 9
Up to 2 pair x 1.5 sqmm instrument cable 1 per No 200 200 9 9
Up to 6 pair x 1.5 sqmm instrument cable 1 per No 300 300 9 9
Up to 12 pair x 1.5 sqmm instrument cable 1 per No 350 350 9 9
Up to 8 traid x 1.5 sqmm cable 1 per No 300 300 9 9
CAT 6 Eathernet cable 1 per No 200 200 9 9
Up to 50 pair Telecom cable 1 per No 200 200 9 9
Optical Fiber Patch chord - 1 pair - Up to 25 meter 1 per No 300 300 9 9
24 Core OFC cable 1 per No 200 200 9 9
Video Cable 1 per No 200 200 9 9

Supply, Laying & Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed copper armoured Cable
Voltage grade 650 / 1100 Volts of following sizes as per GSPL approved make, on cable trays, supported on steel
structures, in ready made trenches/ cable gallery. The rates shall include the supply and fixing of aluminium number
tags, G.I. saddles / clamps, saddle bars, lugs, ferrules, double compression type SS glands, etc, including transportation
with all labor and materials as per the specifications, drawings and directions of GSPL Engineer-in-charge . The
Insulation Resistance of cable has to be checked & report to be submitted before commissioning. No separate charges
shall be paid for manpower,consumables, tools & tackles used during execution of this activity.(Seprate charges shall
be paid for supply of cable tray as per relevent SOR)job is to be executed as per the direction of the GSPL E.I.C. &
GSPL requirement

314
Up to 3 core x 25 sqmm power cable 50 per Mtr. 1175 58750 9 9
Up to 3 core x 6 sqmm power cable 100 per Mtr. 335 33500 9 9
Up to 3 Core x 2.5 sqmm power cable 250 per Mtr. 178 44500 9 9
2 Core x 2.5 sqmm power cable 100 per Mtr. 142 14200 9 9
2 core x 1.5 sqmm power cable 100 per Mtr. 118 11800 9 9
Up to 2 pair x 1.5 sqmm instrument cable 200 per Mtr. 138 27600 9 9
Up to 6 pair x 1.5 sqmm instrument cable 250 per Mtr. 325 81250 9 9
Up to 12 pair x 1.5 sqmm instrument cable 150 per Mtr. 445 66750 9 9
Up to 8 traid x 1.5 sqmm cable 150 per Mtr. 535 80250 9 9
Up to 25 sqmm earthing cable 300 per Mtr. 225 67500 9 9
Supply laying and Termination (using Conduit, Rojet Box ,temrinal block, crimping, connectors) of telecom &
network cables . The Insulation Resistance of cable has to be checked & reported before commissioning. No separate
charges shall be paid for excavation, backfilling, manpower, consumables, equipments, tools & tackles used during
execution of this activity.
Polythene (Solid/Foam Skin) Insulated Jelly Filled Cables Up to 5 Pair 100 per Mtr. 180 18000 9 9
Polythene (Solid/Foam Skin) Insulated Jelly Filled Cables Up to 10 Pair 100 per Mtr. 245 24500 9 9
315
Polythene (Solid/Foam Skin) Insulated Jelly Filled Cables Up to 50 Pair 100 per Mtr. 430 43000 9 9
Flexible 2 pair Telephone cable 250 per Mtr. 48 12000 9 9
Up to 1 sqmm control cable 100 per Mtr. 73 7300 9 9
RG-11 Video Cable 250 per Mtr. 78 19500 9 9
Optical Fiber Patch chord with connector as per GSPL requirement- 1 pair - Up to 25 meter length 10 per Mtr. 350 3500 9 9
CAT 6 Eathernet cable 500 per Mtr. 45 22500 9 9
Erection of new HMI console / panel on MS frame/ RCC slab,the job is to be executed as per the direction of the
316 GSPL E.I.C. Job include shifting from ground floor to first floor, using hydra crain etc (separate charges shall be paid 4 per panel 28000 9 9
for MS steel frame & earthing connectivity as per relevent SOR SOR) 7000

Making of Cable entry hole - 4" & 2" on floor by breaking of RCC by using mechanical breaker / Hammer /
Manually / abrasive cutting machine and disposal of the demolished materials within a lead of 1KM. including
317 20 per No 20000 9 9
stacking of steel bars and disposal of unserviceable material within 1KM lead. No separate charges shall be paid for
manpower, consumables, equipments, handling, tools & tackles used during execution of this activity.
1000
Supply and Installation of DIN Rail Mounted Feed ThroughTerminals Type CST in Melamine Housing with end plates
for below mentioned conductor size, RJ 45 Connector.
1.5 sqmm 1 per No 40 40 9 9
318
2.5 sqmm 1 per No 50 50 9 9
Up to 6 sqmm 1 per No 60 60 9 9
Up to 10 sqmm 1 per No 90 90 9 9
Supply & installation of SS sheet enclosure or Die cast aluminium junction box for field cable joint in case of short
along with all provisions for cable entry, glands, terminals, accessories like studs & washers
SS sheet enclosure Size 300 x 300 - 48 terminal 1 per No 4500 4500 9 9
319
SS sheet enclosure Size 600 x 600 - 96 terminal 1 per No 8500 8500 9 9
Die cast aluminium junction box- Size 300 x 300 - 48 terminal 1 per No 6000 6000 9 9
Die cast aluminium junction box-Size 600 x 600 - 96 terminal 1 per No 12000 12000 9 9
320 OFC Splicing at panel in FTC including pigtels and termination of 24 core in Telecom panel 3 per Joint 7000 21000 9 9

Complete Link Testing End to End with Power Source, Laser Source, OTDR meter working with 1310 nm and 1550
321 nm from both end including Pigtails, Patch cord for testing. And submission of all 24 core OTDR traces between two 3 per Cable 21000 9 9
terminals or across the joints.(Before & after of OFC splicing)
7000

Supply & installation of solid state, chassis mounted, Adjustable Output, Load Sharing, Remote On/Off, Remote
Sense, 3kV Volatge Isolation, Universal Input power supply module (AC-DC) for control panels.
322 2 per No 150000 9 9
Input:100~240 VAC, 4.1A, Output: 24V, 300W, 14A.
Certification: CE, RoHS & ULcompliant.
75000

Supply & installation of (2100mm H (inclusive of 100mm Base channel) x 800mm D x 1000mm W) 42U Floor
mounted, Freestanding, Vertical panel.
Material: Min. 2 mm thickness CRCA sheet metal. Thickness of panel front & Mounting Plate & Gland Plate shall be
3 mm. Top & Bottom cover with cable entry gland plates.
Cabinet Finish: Sand blasting, grinding, chemical cleaning, surface finishing by suitable filter and two coats of high
grade lacquer with wet sanding between two coats.
Panel Paint: RAL-7032 , Siemens Grey for Body / Black for Base Frame.
Protection: Min. IP-42, as per IS – 2147.
Doors: To be provided with lockable handles (flush pull chrome plated handles) and concealed hinges with pull pins
for easy door removal. Panel Doors shall be provided with pockets for storing of manuals/ drawings etc. The racks
must have steel front / rear doors and side panels. Racks should NOT have glass doors / panels.
Lifting Hooks: Removable hooks to be provided for lifting purpose.
323 1 per No 40000 9 9
Accessories (Minimum): Door Switch Operated Light, Thermostat operated space heater, Fans and Fan Tray: 230V
AC, 4" dia (4 Nos. per Rack) setting should be factory settable. This unit should also include - humidity & temperature
sensor, 15A power supply socket, Instrument / Electronic Earth bus 25 x 6mm copper, Body Earth bus 25 x 6mm
copper, Telephone jack,
Power distribution: by MCB & Fused terminals.
Depth support channels: 3 pairs with an overall weight carrying Capacity of 500Kgs.
Must be lockable with unique key for each rack, Panel should have Rear Cable Management channels, Wire managers:
Two vertical and four horizontal
Power Distribution Unit: Vertically Mounted with appropriate number of Power Outputs. (A combination of IEC 320
C13 Sockets & IEC 320 C19 ), Electronically controlled circuits for Surge & Spike protection, 32AMPS MCB, 5 KV
AC isolated input to Ground & Output to Ground.

40000

PART-B: Civil Activities


Earth work in excavation below ground level for all kinds of work in basements, foundations, including trenches etc.
including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, leveling, grading and ramming
of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and
disposal or stacking of excavated material within a lead of 1 KM, as decided including providing temporary supports to
existing service lines like water pipes sewage pipes, electric overhead and underground cables etc. all complete, including
324 shoring and strutting. No separate charges shall be paid for manpower, consumables, equipments, handling, tools & tackles
used during execution of this activity.
Soft soil upto 2.5 meter 750 Cu. Mtr. 390 292500 9 9
Below 2.5 meter 125 Cu. Mtr. 430 53750 9 9
Hard rock upto 2.5 meter 70 Cu. Mtr. 500 35000 9 9
Hard rock below 2.5 meter 2 Cu. Mtr. 550 1100 9 9
Back-filling of available excavated earth (excluding rock) in trench, sides of foundation etc in layers not exceeding 20 cm in
depth consolidating earth deposited layer by ramming and watering, lead up to 100 Mtr. and filling up to required Ground
325 750 Cu. Mtr. 150000 9 9
level. No separate charges shall be paid for manpower, consumables, equipments, handling, tools & tackles used during
execution of this activity. 200
Breaking of PCC by using mechanical breaker / Hammer / Manually / abrasive cutting machine and disposal of the
326 demolished materials within a lead of 1KM. No separate charges shall be paid for manpower, consumables, equipments, 12 Cu. Mtr. 15240 9 9
handling, tools & tackles used during execution of this activity. 1270
Breaking of RCC by using mechanical breaker / Hammer / Manually / abrasive cutting machine and disposal of the
demolished materials within a lead of 1KM. including stacking of steel bars and disposal of unserviceable material within
327 1 Cu. Mtr. 5500 9 9
1KM lead. No separate charges shall be paid for manpower, consumables, equipments, handling, tools & tackles used
during execution of this activity. 5500
Supply & filling of Good Quality Sand in trench, sides of foundation, bottom of foundations for FML skid/piping supports
etc in layers not exceeding 100 mm in depth consolidating each layer by ramming and watering up to required level. No
328 1 Cu. Mtr. 1000 9 9
separate charges shall be paid for manpower, consumables, equipments, handling, tools & tackles used during execution of
this activity. 1000
Supply & filling Rubble Soiling (200-250 mm thick) in trench, bottom of foundations for FML skid/piping supports etc up
329 to required level complete as per drawings, specifications and as directed by EIC. No separate charges shall be paid for 30 Sq. Mtr. 38400 9 9
manpower, consumables, equipments, handling, tools & tackles used during execution of this activity. 1280

Providing, mixing and laying binding layer of PCC Grade of 1:3:6 nominal mix using 40 mm and downgraded coarse
aggregate for any thickness below footings, plinth beams, foundations, trenches, pits & sumps etc. using ordinary Portland
330 cement, curing etc., complete as per drawings, specifications and as directed by EIC. Centring & Shuttering is also in the 25 Cu. Mtr. 130000 9 9
scope. No separate charges shall be paid for manpower, consumables, equipments, handling, tools & tackles used during
execution of this activity.
5200
Providing reinforcement (HYSD bars) for RCC work including bending, binding and placing in position complete as per
standard ISI 422 part 1. Transportation, loading, unloading & handling of materials to site are included. No separate charges
331 3300 Kg 330000 9 9
shall be paid for manpower, consumables,lifting equipments, handling, tools & tackles used during execution of this
activity. 100

Providing RCC work M15 1:2:4 (1cement, 2 coarse sand , 4 graded stone aggregate size 20mm nominal size) in support,
332 foundation, footing, pavements, floors etc. This job includes providing Centering and shuttering, strutting, propping and 100 Cu. Mtr. 620000 9 9
removal of form with all tools / tackles / labour /machinery etc. Charges of HYSD bars shall be paid as per relevent SOR.
6200
Providing RCC work M20 1:1.5:3 (1cement, 1.5 coarse sand , 3 graded stone aggregate size 20mm nominal size) in
support, foundation, footing, pavements, floors etc. This job includes providing Centering and shuttering, strutting,
333 1 7200 9 9
propping and removal of form with all tools / tackles / labour /machinery etc. Charges of HYSD bars shall be paid as per
relevent SOR. 7200

Providing RCC work M25 1:1:2 (1cement, 1 coarse sand , 2 graded stone aggregate size 20mm nominal size) in support,
334 foundation, footing, pavements, floors etc. This job includes providing Centering and shuttering, strutting, propping and 1 7400 9 9
removal of form with all tools / tackles / labour /machinery etc. Charges of HYSD bars shall be paid as per relevent SOR.
7400
12mm thick plaster in 1:4 cement-mortar, providing & applying finish cement plaster at all heights, levels and places,
335 including scaffolding, chipping, roughing up the concrete , curing and finishing . No separate charges shall be paid for 100 Sq . Mtr. 35000 9 9
manpower, consumables, equipments, scaffolding, handling, tools & tackles used during execution of this activity. 350
Demolishing brick work in cement mortar including staking of serviceable materials and disposal of unserviceable material
336 1 Cu. Mtr. 1700 9 9
within 1KM lead including transportation/labour etc. 1700
Providing and laying 50 B Class Brick Masonry Work in foundation / superstructure with Cement Mortar 1:6 (1 Cement: 6
Coarse Sand) as per specifications in one or more brick thickness and in any standard shape (excluding circular/curved)
including providing recesses, opening, scaffolding, staging, curing, finishing the joints flush below ground level and raking
337 out joints in and above plinth level etc. all complete.
At all depths below and upto 2.5 Mtr. from Ground level 1 Cu. Mtr. 6000 6000 9 9
At all heights above 2.5 Mtr. from Ground Level 1 Cu. Mtr. 6500 6500 9 9
Dismantling and stacking of damaged lighting pole of sizes upto15M including excavation, cutting etc.& backfilling if
required, completion of job in totality to the satisfaction of EIC within a lead of 100Mtr. The safe removal of existing
338 luminaire, JBs, Earthing connection, cable connection etc. from the pole and handing over of same to GSPL is in 20 Nos. 80000 9 9
contractor's scope. No separate charges shall be paid for manpower, consumables,lifting equipments, handling, tools &
tackles used during execution of this activity. 4000
Relocation of Lighting / Solar pole within the terminal which includes removal with or without RCC foundation & re-
installation with proper foudation , concrete support etc. complete in all respect. This also includes leveling of old
foundation location & backfilling if required, with all tools/tackles/labour/machinery/Hydra etc. Removal of fixtures, JB,
339 7 Nos. 39200 9 9
earthing connections, Cable connections from pole at old location & reconnection and testing of all the system at new
location is included in the scope.
In case of relocation of pole to other terminal the transportation shall be given as per the relevant SOR. 5600
Painting, Numbering & Lettering of existing pipeline markers and painting of vent pipes in cased crossings including
Supply of paint and application of 2 coats of red-oxide primer and 2 coats of zebra strip (black and golden yellow stripes)
of approved quality to give an even shade after proper scraping of existing paint and clearing of surface free from foreign
materials. The rate are including man/ material and transportation to the position / site.
Vent Pipes 1 Sq. Mtr. 120 120 9 9
Direction Marker 175 Nos. 1200 210000 9 9
340
340 Warning Marker 220 Nos. 1200 264000 9 9
K.M. Marker 75 Nos. 1200 90000 9 9
Aerial Marker 20 Nos. 1200 24000 9 9
OFC Marker 1 Nos. 450 450 9 9
Navigation Marker 1 Nos. 2890 2890 9 9
RoU Boundary Marker 100 Nos. 590 59000 9 9
TLP 4 Nos. 1900 7600 9 9
Supply of Station approach road direction markers including stenciling the logo, arrow markers & signs; to be installed at
roadsides as per the specimen drawing DRW. No. GSPL-AMC-STD-14 enclosed including supply of all materials for
grouting in 1:3:6 PCC mixtures to correct line, level and direction. The work also includes transportation to site of
341 4 Nos. 36000 9 9
installation, necessary excavation for grouting of post, cleaning under ground portion upto 300 mm height from the ground
level. No separate charges shall be paid for manpower, consumables,lifting equipments, handling, tools & tackles used
during execution of this activity. 9000
Supply, transportation & installation of Navigation Marker (of size 5m X 2m with required chanels for grouting) at River
Crossing including painting, stenciling the logo, arrow markers & signs as per specimen drawing DRW. No. GSPL-AMC-
342 STD-10 enclosed. The Job includes supply of all materials for grouting in 1:3:6 PCC mixtures to correct line, level and 1 Nos. 10000 9 9
direction. The work also includes transportation to site of installation, necessary excavation for grouting of post, cleaning
ground portion upto 300 mm height from the ground level & restoration. 10000
Stenciling of English / Gujarati / numerical letters on sign boards and markers wherever required as per directed by GSPL
E-I-C:
Aerial Marker as per DWG. No. GSPL-AMC-STD-08 20 Nos. 700 14000 9 9
K.M. Marker as per DWG. No. GSPL-AMC-STD-09 12 Nos. 700 8400 9 9
343 Direction Marker as per DWG. No. GSPL-AMC-STD-10 6 Nos. 700 4200 9 9
Warning Marker as per DWG. No. GSPL-AMC-STD-11 1 Nos. 700 700 9 9
OFC Marker as per DWG. No. GSPL-AMC-STD-05 1 Nos. 700 700 9 9
Navigation Markeras per DWG. No. GSPL-AMC-STD-? 2 Nos. 1500 3000 9 9
Sign Board as per DWG. No. GSPL-AMC-STD-14 12 Nos. 700 8400 9 9
Supply, transportation and installation of new direction marker / warning Marker on pipeline RoU as per DWG. No. GSPL-
AMC-STD-10 / GSPL-AMC-STD-11 including supply of all materials for fabrication, cleaning, two coats of red-oxide and
two coats of zebra color (black and golden yellow strips) of approved quality (I S I Mark) paint and marking the number,
direction, chainage and pipe size. Excavation upto required size, grouting in 1:3:6 PCC mixture to correct line, level and
direction, back-filling & restoration. The work is to be executed as per drawing and direction E.I.C. No separate charges
344 shall be paid for manpower, consumables, transportation, lifting equipments, handling, tools & tackles used during
execution of this activity.
Type-I, For normal soil 25 Nos. 8500 212500 9 9
Type-II, For drifting sand soil 1 Nos. 9200 9200 9 9
Type-III, For Rocky areas 1 Nos. 9200 9200 9 9

Supply, transportation and installation of new Arial marker on pipeline RoU as per DWG. No. GSPL-AMC-STD-08
including supply of all materials for fabrication, cleaning, two coats of red-oxide and two coats of zebra color (black and
golden yellow strips) of approved quality (I S I Mark) paint and marking the number, direction, chainage and pipe size.
Excavation upto required size, grouting in 1:3:6 PCC mixture to correct line, level and direction, back-filling & restoration.
345 The work is to be executed as per drawing and direction E.I.C. No separate charges shall be paid for manpower,
consumables, transportation, lifting equipments, handling, tools & tackles used during execution of this activity.

Type-I, For normal soil 5 Nos. 8500 42500 9 9


Type-II, For drifting sand soil 1 Nos. 9200 9200 9 9
Type-III, For Rocky areas 1 Nos. 9200 9200 9 9
Supply, Transportation and installation of new K.M. Marker as per DWG. No. GSPL-AMC-STD-09 including supply of all
materials for fabrication, cleaning, two coats of red-oxide and two coats of zebra color (black and golden yellow strips) of
approved quality (I S I Mark) paint and marking the number, direction, chainage and pipe size. Excavation upto required
size, grouting in 1:3:6 PCC mixture to correct line, level and direction, back-filling & restoration. The work is to be
346 executed as per drawing and direction E.I.C. No separate charges shall be paid for manpower, consumables, transportation,
lifting equipments, handling, tools & tackles used during execution of this activity.
Type-I, For normal soil 10 Nos. 8500 85000 9 9
Type-II, For drifting sand soil 1 Nos. 9200 9200 9 9
Type-III, For Rocky areas 1 Nos. 9200 9200 9 9

Supply, Transportation and installation of new OFC Marker as per DWG. No. GSPL-AMC-STD-05 including supply of
all materials for fabrication, cleaning, two coats of red-oxide and two coats of zebra color (black and golden yellow strips)
of approved quality (I S I Mark) paint and marking the number, direction, chainage and pipe size. Excavation upto required
size, grouting in 1:3:6 PCC mixture to correct line, level and direction, back-filling & restoration. The work is to be
347 executed as per drawing and direction E.I.C. No separate charges shall be paid for manpower, consumables, transportation,
lifting equipments, handling, tools & tackles used during execution of this activity.
347

Type-I, For normal soil 1 Nos. 8500 8500 9 9


Type-II, For drifting sand soil 1 Nos. 8500 8500 9 9
Type-III, For Rocky areas 1 Nos. 8500 8500 9 9

Supply, transportation and installation of pre-cast RCC (1:2:4) RoU boundary markers on pipeline RoU as per drawing No.-
DWG. No. GSPL-AMC-STD-04 or as per direction of E.I.C. The work also includes necessary excavation of pits, grouting
348 100 Nos. 140000 9 9
of post & restoration. No separate charges shall be paid for manpower, consumables, transportation to site location, tools &
tackles used during execution of this activity.
1400

Filling empty cement bags of 50 kg capacity (the bags to be used in good condition only) by using sand/cement mixture in
10: 1 ratio and stitching by using jute threads and placing in position in RoW as directed by engineer-in-charge /Site
349 500 Nos. 45000 9 9
Engineer. No separate charges shall be paid for manpower, consumables, transportation to site location, tools & tackles used
during execution of this activity.
90
Providing temporary supports to existing Instrument / Electrical panels/DG set/PRS/Valves and equipments etc with
350 1 Location 700 9 9
metallic scaffolding material / wooden sleepers or Jacks etc. 700
Cleaning of valve chamber / condensate pit including de-watering, cleaning of moisture content, sludge removal, cleaning
Per Chamber /
351 with fresh water, drying of cleaned valve chamber or condensate pit and disposal of sludge and debris within a lead of 1 1 500 9 9
PIT
KM. 500
Providing stone pitching average 230-250mm thickness with the joints filled up with cement mortar of 1:6. Including
preparation of the bed slope, cutting and filing earth, compacting to the 90% of proctor's density, filling the joints with 1:6
352 1 Sq. Mtr. 4500 9 9
cement mortar pointing the joints with same mortar complete in all respects including the supply of stone boulders, all
materials, labour and consumables etc. as directed by engineer-in-charge and as per the specifications. 4500
Installation of fallen boundary stones / pipeline makers, the job includes supply of all materials required to complete the re-
353 installation works including excavation, fixing of boundary stone/pipeline marker on pipeline RoU in PCC 1:3:6 to correct 1 Nos. 1890 9 9
line & level, restoration etc. Complete job as per specification and direction of E.I.C. 1890
Supply and installation of concertina Razor wire to replace the existing damage portion fencing of dia. 500mm of GI
barbed wire 12SWG in helical shape of wire to wire distance 250mm spacing in existing boundary wall with 8 nos(4 on
354 each side) horizontal wiring at 45 degree spacing each as described in drawing. 1 R. Mtr. 1650 9 9
The 'Y' Steel Structure if used shall be claimed as per relevent SOR. New structure work includes sand blasting , primer and
2 coats of aluminium paint for structural work. 1650
Supply and installation of Barbed wire( 6 Wire) fencing to replace the existing damage portion mm of GI barbed wire
12SWG in existing boundary wall.
355 1 R. Mtr. 1650 9 9
The Steel Structure if used shall be claimed as per relevent SOR. New structure work includes sand blasting , primer and 2
coats of aluminium paint for structural work and existing with single coal of aluminium painting 1650
356 Supply and installation of GI Chain link fencing with hole size of 50 mm 1 Sq. Mtr. 1000 1000 9 9

Washout repair job on existing buried pipeline, which occur mostly during monsoon period: Supplying and filling selected
loose earth other than black cotton soil from borrowed pits
in the washout/depressed land or in the pit locations of pipeline ROW compacting up to 90% of proctor density and filling
in layers not exceeding 200 mm including cost of transportation, spreading, compacting, all as directed by engineer-in-
357 1 Cu. Mtr. 880 9 9
charge. The rates includes royalty or any other levies by Govt. agencies towards taking of loose earth from borrowed area as
per the direction of engineer-in-charge
/site engineer inclusive all labour, materials, tools, tackles, transportation, taxes etc. completion all respect. (Payment shall
be made on basis of measurement of the pit profile of the earth washout in the ROW)
880
Supplying and laying in position of RCC NP3 class pipes with collars, confirming to IS: 458 for pipe culverts, cable
crossing, road crossing etc. including cutting the hume pipe if necessary, lowering, laying in position to proper levels, slopes
etc. caulking the joints with spun yarn soaked in neat cement slurry and finishing with cement mortar 1: 2 (1 Cement: 2
Sand) curing etc. all complete as per drawings / specifications and directions of Owner/Owner’s Representative. Rate is
included the cost of excavation up to 1.2-meter cover and backfilling of earth. Providing bedding concrete of PCC (1:4:8)
358 75 mm thick and backfilling with good earth
100 mm dia pipes 1 R. Mtr. 1200 1200 9 9
300 mm dia pipes 1 R. Mtr. 2800 2800 9 9
400 mm dia pipes 1 R. Mtr. 3400 3400 9 9
500 mm dia pipes 1 R. Mtr. 4300 4300 9 9
Monitoring of RoU and PSP by foot patrolling with the help of GPS based mobile application along the route of pipeline.
359 1 Km 500 9 9
GSPL will provide mobile with installed software. 500
360 Supply and Installation of 1" UPVC water pipeline in control room building / terminal at damaged locations 1 R. Mtr. 450 450 9 9
Supply & Replacement of Open Path gas Detector of GSPL approved make & model.with control card and full intregration
361 1 No. 22000 9 9
as per the given specification by EIC and as per GSPL requirement for Gas Detection System. 22000
362 Transportation of material up to 2 Tonnes from one location to another location
Tata 407 1 Km 100 100 9 9
Eicher 1 Km 150 150 9 9
Truck 1 Km 200 200 9 9
Total Amount (In Words):Six Crore twelve Lacs eighty seven thousands and eight hundred eighty Rs and Seventy six Paisa only
Note:
1. Bidders are required to visit station, mainline and associated facilities to make themshelves fully aware of the typical facilities of GSPL installation. Based on that bidder shall quote the price against each SOR item.

2. The description given under the items of work in Schedule of Rates shall be deemed to include, wherever applicable, mobilisation ,labour, equipments, materials and fixing in position of all materials and equipments, disposal of wastages, desludging and allied operations at any stage of the work and a
operations necessary whether specifically stated/implied or not, for the full and entire execution and completion of the relative works in all respects according to the contract. Cost of materials under the scope of Contractor’s supply & all other consumables/inputs required for carrying out the works & for
incorporation in the works for which rates are quoted in the "Schedule of Rates" shall be inclusive of all duties, taxes (excluding GST), etc as applicable.

3. Based on the SOR price, the contracr shall be liable to execute each SOR items irrespective of rate change/escalations as per the requirement given by GSPL. In case contractor deny to execute any of the SOR item within the specified timeline given in the work request then the work shall be carried o
at the risk & cost of engaged ARC contractor. Cost of the same shall be recovered from the ARC contractor either from RA Bills or from Performanace Bank Garuentee (PBG).
4. Without prejudice to any other right(s) the Owner reserves the right to change the frequency of work/ activities/ quantity appearing in the shedule of Rates without any clarification to the qualified bidder. GSPL shall also reserve a right to offload any particular line item/ actvity to any specilized agency
of time and ARC contractor shall not make any claim related to the offloaded/ deleted items.
5. The Quantities mentioned above are estimated for evaluation purpose. Payment shall be made based on Actual Quantity executed.
6. The quatity is indicative for entire grid. Actual award of work shall be done zonewise.
7. Bidder should strictly quote as per price bid format only.Any bid not conforming to the price bid formats shall be liable for rejection.
8. The bidder should quote for all the items.Incomplete price SoRs shall not be considered for evaluation.Scope mentioned to be read along with tender in totality.
9. GSPL reserves the right to reject any bid without any reason whatsoever
10. Bidder confirms that he has noted the contents of notes to the price schedule, bid document and quoted his prices accordingly without any deviation.
NETWORK

Total tax amount Gross Amount

L = G x (H+I+K) or M=G+L
L = G x (J+K)

108000 708000

6840 44840

15525 101775

8100 53100

45000 295000
630 4130
630 4130
630 4130
630 4130
630 4130
900 5900
900 5900
900 5900
900 5900
1260 8260
1260 8260

90 590
90 590
90 590
180 1180
180 1180
270 1770
270 1770
360 2360
360 2360
360 2360
450 2950
450 2950
450 2950

2520 16520
2880 18880
3240 21240
4140 27140
4500 29500
4860 31860
5760 37760
6300 41300
8100 53100
9900 64900
11700 76700
13680 89680
28080 184080
63360 415360
38880 254880
21240 139240
149040 977040
26640 174640
241920 1585920
427680 2803680
149760 981760
39240 257240

20160 132160
5040 33040
20160 132160
20520 134520
18000 118000
19440 127440

11520 75520
7200 47200

27000 177000
50400 330400
46800 306800
43200 283200
25200 165200
27000 177000
13950 91450

27000 177000
50400 330400
46800 306800
43200 283200
25200 165200
27000 177000
13950 91450

3420 22420
4275 28025
810 5310
1350 8850
3600 23600
4950 32450
1044 6844
3402 22302
1152 7552
1224 8024
1584 10384
1584 10384
1584 10384

855 5605
2565 16815
864 5664
2160 14160
7200 47200
5184 33984
936 6136
4032 26432
1044 6844
2278.8 14938.8
3168 20768
1620 10620
1620 10620

1080 7080
540 3540
1800 11800
900 5900
1080 7080

72 472
216 1416
216 1416
324 2124
900 5900
900 5900
360 2360
1728 11328
900 5900
10800 70800
19800 129800
16200 106200
1350 8850

2160 14160
720 4720
288 1888
2880 18880
90 590
90 590

1440 9440
1512 9912
1620 10620
1692 11092
1800 11800
1872 12272
1980 12980
2070 13570
2340 15340
2430 15930
2520 16520
2610 17110
2700 17700
2790 18290
2880 18880
2970 19470

1080 7080
1116 7316
1170 7670
1206 7906
1260 8260
1296 8496
1314 8614
1350 8850
1350 8850
1386 9086
1404 9204
1440 9440
1440 9440
1476 9676
1530 10030
1584 10384
3600 23600
2160 14160
2340 15340
576 3776
648 4248
360 2360

180 1180
216 1416
234 1534
288 1888
324 2124
360 2360

4320 28320
626.4 4106.4
2808 18408
3240 21240
2970 19470
7020 46020
6300 41300
396 2596
396 2596
450 2950
450 2950

6912 45312
1044 6844
1404 9204
5616 36816
2565 16815
1274.4 8354.4
4608 30208
396 2596
396 2596
450 2950
450 2950

1080 7080

7200 47200
4320 28320
5040 33040

9792 64192
18360 120360

11430 74930
4320 28320
540 3540
216 1416
450 2950
180 1180
198 1298
1170 7670
360 2360
198 1298
864 5664
216 1416
216 1416

45000 295000
9900 64900
49500 324500
10800 70800
14400 94400
3060 20060
18000 118000
3600 23600
3600 23600
1800 11800
9900 64900
3960 25960
4320 28320
2160 14160

25920 169920
21600 141600
2700 17700

630 4130
810 5310
900 5900
990 6490
1080 7080
1260 8260
1440 9440
1800 11800
2160 14160
2520 16520

46800 306800
72000 472000
189000 1239000
62100 407100
457.2 2997.2
685.8 4495.8
1143 7493
1710 11210
1890 12390
1143 7493
1260 8260
1170 7670
1170 7670
90 590
117 767
135 885
162 1062
198 1298
162 1062
162 1062

24300 159300
21600 141600
8100 53100
1800 11800
450 2950
612 4012
630 4130

86400 566400
5400 35400
9504 62304
2700 17700
1440 9440
1530 10030
1530 10030
1530 10030
1530 10030
1530 10030

2160 14160
2160 14160
2160 14160
2160 14160
2160 14160
2160 14160
2160 14160

4500 29500

360 2360
756 4956
972 6372
1296 8496
1296 8496
2880 18880
2160 14160
360 2360
792 5192
450 2950
1800 11800
450 2950
810 5310
7560 49560
4320 28320
1800 11800
4320 28320
3240 21240

2430 15930
352.8 2312.8

6840 44840
3510 23010

149.4 979.4
153 1003

149.4 979.4
153 1003

10080 66080
11160 73160
4500 29500
7200 47200
8100 53100
9360 61360
72 472
1620 10620

1080 7080
1170 7670

144 944
144 944
144 944
144 944
162 1062
174.6 1144.6
201.6 1321.6
212.4 1392.4
214.2 1404.2
67500 442500
2475 16225
13860 90860
18000 118000
20250 132750
4500 29500
11340 74340
198 1298
8280 54280
3240 21240
1080 7080
135 885

1800 11800
3600 23600
432 2832
945 6195
945 6195
630 4130
720 4720
864 5664
180 1180
1080 7080
1620 10620
270 1770
270 1770

720 4720
810 5310
900 5900

10440 68440
45000 295000
2610 17110
2610 17110

24300 159300
20250 132750
15750 103250
900 5900
3150 20650
3150 20650
27540 180540
78750 516250
94500 619500
6300 41300

24480 160480

1890 12390

126 826

24750 162250

1080 7080

216000 1416000

2808 18408

28800 188800

72000 472000

138600 908600

12600 82600
16200 106200

5760 37760

360 2360
540 3540
810 5310

79200 519200

3960 25960

99900 654900
162000 1062000

25200 165200

8640 56640

12420 81420

4752 31152

2880 18880

10800 70800

7020 46020

17550 115050
2160 14160

1440 9440

990 6490
990 6490
10800 70800
1728 11328
17280 113280
16560 108560
2232 14632
10080 66080
4320 28320
1080 7080
1440 9440
1944 12744
2700 17700
14580 95580
2340 15340
900 5900
4950 32450
4455 29205
5670 37170

2700 17700
12870 84370
4455 29205
15300 100300
43200 283200
4860 31860
1980 12980
783 5133
783 5133
783 5133
22500 147500

25.2 165.2
540 3540
324 2124
279 1829
324 2124
432 2832
252 1652
216 1416
4590 30090
57.6 377.6
194.4 1274.4
99 649
1530 10030
1530 10030
1053 6903
1053 6903
1260 8260
1260 8260
1440 9440

360 2360
450 2950

5400 35400
14175 92925
450 2950
351 2301
3240 21240
1350 8850
1764 11564
2250 14750
3150 20650
1530 10030

1350 8850

459 3009

7110 46610

1665 10915

360 2360
360 2360
360 2360
360 2360
360 2360
360 2360
360 2360

11700 76700
14850 97350

14.4 94.4
14.4 94.4
16.2 106.2
396 2596
702 4602
405 2655
5400 35400
234 1534
61.2 401.2
72 472

1800 11800
9360 61360
2520 16520
2610 17110
2880 18880
297 1947
342 2242
1062 6962

2520 16520
2610 17110
2700 17700
3150 20650
3420 22420
3600 23600
3960 25960

432 2832
540 3540
666 4366

4680 30680
43.2 283.2
45 295
345.6 2265.6
309.6 2029.6
482.4 3162.4

504 3304
504 3304

118.8 778.8
675 4425
1188 7788
442.8 2902.8
576 3776
864 5664
50.4 330.4
302.4 1982.4
63 413
50.4 330.4
75.6 495.6
14.4 94.4
126 826
19440 127440
36 236
21.6 141.6
27 177
32.4 212.4

108 708
144 944

43.2 283.2
81 531

63 413
81 531
99 649
97.2 637.2

5130 33630

1296 8496

5040 33040
9180 60180

900 5900
225 1475
324 2124

162 1062

720 4720
630 4130
225 1475
333 2183
4248 27848

1008 6608

558 3658

2736 17936
1944 12744
135 885
378 2478

4140 27140

4860 31860

432 2832
486 3186

405 2655
423 2773
450 2950
468 3068
783 5133
486 3186

59.4 389.4
13500 88500
5040 33040
3276 21476
109.8 719.8
109.8 719.8
1350 8850
216 1416
234 1534
630 4130
64.8 424.8
2106 13806
82.8 542.8
99 649
122.4 802.4

30.6 200.6
1260 8260
1332 8732
57.6 377.6
61.2 401.2
63 413
72 472
66.6 436.6

2430 15930
489.6 3209.6
82.8 542.8
3240 21240
37.8 247.8
10125 66375

1980 12980
324 2124
675 4425
10.8 70.8
576 3776
270 1770

27000 177000
6300 41300
90 590
5400 35400
126 826
4050 26550
180 1180
4950 32450
4608 30208
68.4 448.4
2160 14160
144 944
154.8 1014.8
172.8 1132.8
67.5 442.5

4095 26845
63 413
99 649
99 649
126 826
144 944
972 6372
171 1121
180 1180
198 1298
180 1180
39.6 259.6
43.2 283.2

17640 115640
13230 86730
6930 45430
5355 35105
14490 94990
10710 70210
5670 37170

32.4 212.4
10800 70800
99 649
153 1003
810 5310
2304 15104
765 5015
194.4 1274.4

58.5 383.5
76.5 501.5
315 2065
16.2 106.2

900 5900
6804 44604
1350 8850

1170 7670
1404 9204

9900 64900

396 2596

6264 41064

2970 19470
1800 11800
2160 14160
2160 14160
3960 25960
540 3540

540 3540
162 1062
900 5900
882 5782
21.6 141.6
32.4 212.4
45 295
54 354
180 1180

1728 11328

75.6 495.6
288 1888
3564 23364
468 3068
675 4425
432 2832
378 2478
52.2 342.2
61.2 401.2

783 5133
324 2124
7020 46020
90 590
108 708

900 5900
124.2 814.2
124.2 814.2
124.2 814.2

1890 12390
1980 12980
1710 11210
7200 47200

340.2 2230.2

396 2596

11340 74340
7200 47200
9000 59000
8100 53100
3240 21240
135000 885000

1224 8024
4455 29205
270 1770

54 354
324 2124
36 236
90 590

36 236

45 295

540 3540
630 4130
720 4720

540 3540
630 4130
720 4720

9180 60180

1080 7080
8100 53100
450 2950
630 4130
1890 12390

4320 28320

64.8 424.8

135 885
153 1003
180 1180

459 3009
1368 8968
180 1180

126 826
153 1003
180 1180
126 826
144 944
171 1121
3600 23600

432 2832
1404 9204
252 1652

4536 29736
37800 247800
756 4956

19800 129800
24840 162840
2565 16815

540 3540
1530 10030
171 1121

1872 12272
8100 53100
612 4012

3456 22656
12960 84960
900 5900
720 4720
450 2950

3420 22420
9900 64900
1350 8850
3420 22420

4140 27140

26325 172575

2160 14160
3150 20650
432 2832
675 4425
8437.5 55312.5

1296 8496

100980 661980
13680 89680
120.6 790.6
324 2124
216 1416
144 944
90 590
90 590
630 4130
900 5900
18 118
18000 118000
630 4130

630 4130

2160 14160

7560 49560
7560 49560
10080 66080
4680 30680
3960 25960
216 1416

972 6372

648 4248

225 1475

3600 23600
41040 269040
126 826

160.2 1050.2

810 5310

43200 283200
23400 153400
1980 12980
2250 14750
2610 17110

9630 63130
2430 15930
4086 26786
5200.2 34090.2

756 4956
900 5900

324 2124
630 4130
2880 18880
4500 29500

81000 531000
94500 619500
2250 14750
54 354
1620 10620
3825 25075

711 4661
189 1239
810 5310
189 1239
711 4661
176.4 1156.4
176.4 1156.4
531 3481
531 3481
135 885

216 1416

270 1770
270 1770
270 1770
270 1770
243 1593
270 1770

1080 7080
243 1593
270 1770
270 1770
243 1593

27000 177000

26.1 171.1
39.6 259.6

216 1416

234 1534
279 1829

810 5310

7200 47200
864 5664
153 1003

14850 97350

257400 1687400

51750 339250

5400 35400

810 5310
4320 28320
1980 12980
2700 17700

1602 10502
2700 17700
3600 23600
2610 17110
3150 20650
3690 24190
3690 24190
1170 7670
3960 25960
5400 35400
6300 41300
7920 51920
10800 70800
7200 47200
8100 53100

10440 68440
522 3422
5220 34220

7200 47200
10800 70800
14400 94400
18000 118000
25200 165200
32400 212400
37800 247800
39600 259600

2160 14160
72 472
106.2 696.2
144 944
78300 513300
3240 21240
630 4130
45 295
1134 7434
24750 162250
702 4602
630 4130

7560 49560
25650 168150
69300 454300
115830 759330
107100 702100
178200 1168200
288 1888
324 2124
324 2124
4500 29500

4500 29500

10800 70800

2700 17700
342 2242
117 767
3240 21240

1890 12390

216 1416

117 767

216 1416

2160 14160

7020 46020

22500 147500

140.4 920.4

810 5310
153 1003
450 2950
270 1770
1710 11210
405 2655
990 6490
2250 14750
315 2065
252 1652
324 2124
2700 17700

81 531

3600 23600
4500 29500
11.16 73.16

118800 778800
720 4720
3420.9 22425.9

432 2832
90 590
108 708
144 944

54000 354000
9000 59000
7200 47200
18000 118000
4500 29500
4500 29500
1800 11800

18000 118000

216 1416
216 1416

252 1652
252 1652

216 1416
1728 11328
896.4 5876.4
896.4 5876.4
1134 7434
1134 7434

214.2 1404.2
214.2 1404.2

432 2832
558 3658
684 4484
792 5192
900 5900
990 6490
450 2950
450 2950
540 3540
630 4130
720 4720
990 6490
4320 28320

450 2950
450 2950
540 3540
630 4130
720 4720
990 6490
1080 7080
1260 8260
1350 8850

178.2 1168.2
178.2 1168.2
178.2 1168.2
196.2 1286.2
396 2596
540 3540
630 4130
774 5074
900 5900

540 3540
720 4720
900 5900
1080 7080
1260 8260
1800 11800
2160 14160
2520 16520

432 2832
540 3540
720 4720
900 5900
1080 7080
1440 9440
1800 11800
2340 15340

900 5900
900 5900
990 6490
990 6490
1080 7080
1170 7670
1260 8260
1350 8850
1440 9440
1530 10030

252 1652
360 2360
522 3422
1260 8260
1260 8260
2160 14160
2160 14160
2160 14160
360 2360

9900 64900

3600 23600

810 5310

324 2124
432 2832
918 6018
54 354
90 590
126 826
270 1770
360 2360
450 2950
1458 9558
63 413

540 3540
1080 7080
1800 11800
2160 14160
2340 15340
4500 29500
4320 28320

352350 2309850
990 6490
990 6490
990 6490
720 4720
45000 295000
270 1770
2160 14160
2700 17700
540 3540
720 4720
360 2360
72 472
126 826

1350 8850

28800 188800

18000 118000

30600 200600

108 708
54 354
36 236
36 236
36 236
36 236
36 236
54 354
63 413
54 354
36 236
36 236
54 354
36 236
36 236

108 708
54 354
36 236
36 236
36 236
36 236
36 236
54 354
63 413
54 354
36 236
36 236
54 354
36 236
36 236

10575 69325
6030 39530
8010 52510
2556 16756
2124 13924
4968 32568
14625 95875
12015 78765
14445 94695
12150 79650

3240 21240
4410 28910
7740 50740
2160 14160
1314 8614
3510 23010
630 4130
4050 26550

5040 33040

3600 23600

7.2 47.2
9 59
10.8 70.8
16.2 106.2
810 5310
1530 10030
1080 7080
2160 14160
3780 24780

3780 24780

27000 177000

7200 47200

52650 345150
9675 63425
6300 41300
198 1298

27000 177000

2743.2 17983.2
990 6490

180 1180

6912 45312

23400 153400

59400 389400

111600 731600

1296 8496

1332 8732

6300 41300

306 2006

1080 7080
1170 7670

14400 94400

7056 46256

21.6 141.6
37800 247800
47520 311520
16200 106200
4320 28320
81 531
520.2 3410.2
10620 69620
1368 8968

6480 42480

1800 11800

2520 16520
1512 9912
756 4956
126 826
126 826
540 3540
1512 9912

38250 250750
1656 10856
1656 10856

7650 50150
1656 10856
1656 10856

15300 100300
1656 10856
1656 10856
1530 10030
1530 10030
1530 10030

25200 165200

8100 53100

126 826

90 590

810 5310

340.2 2230.2

297 1947

297 1947

180 1180

158.4 1038.4

216 1416
504 3304
612 4012
774 5074
90 590
81 531
3960 25960

18 118
27 177
36 236
61287880.76

rations at any stage of the work and all other labours and
uired for carrying out the works & for permanent

quest then the work shall be carried out by any other agency

item/ actvity to any specilized agency/ vendor at any point

Вам также может понравиться