H= 0.

7 f
F= 0.7 f
1. Determine the total wetted surface area K1 = 1.4
K= K1
K= 1.4
E1 = 0.7
E= E1 f if cylindrical
E= 0.7 f
Es = 0.7 FT D/2= 9.25 m if spherical
D = 0.7 FT 31 f
pi = 3.14 Es= d/2
Awet 1.5386 f2 Es= 31 f

K = Effective total height of liquid surface (f)


K1 = Total height of liquid surface (f)
H = Vessel Elevation (f)
F = Liquid depth in vessel (f)
E = Effective liquid Level (f)
E1 = Initial liquid level (f)
Es = Effective spherical liquid level (f)

2. Determine the total heat absorption

F= 1
Awet 1.5386 f2
Q 49120.43 btu/h
3. Determine the rate of vapour or gas vaporized from the liquid

Q= 49120.43 btu/h
Hvap = 129.1 btu/lb (From Hysys)
W= 380.4836 lb/h 173 Kg/h
840 kg/m3
V 0.205952 m3/h 0.92 gpm

thermal expansion

Relieve Rate (gpm)


API Gravity 44.9 Data mas galin
B 0.0005 Table 3 api521
H
G
C
PSV LOAD CALCULATION
PSV No. :

CAUSE : Open External Fire ---> Vapor Expansion

CALCULATION: CALCULATION FOR (UNWETTED WESSEL): FOR GASSY SYSTEM

Sketch Vessel diameter 1910 mm


Vessel height exposed to fire 1400.0 mm
Height of flame from grade 1900 mm

Head type: (1) 2:1 ellipsoidal


3820 mm (2) hemisphere
your choice is (1 or 2) = 1

Area exposed to fire 16.35 m2


500 mm

GROUND

Set Pressure 13.06 kg/cm2A


Temp. @ Set Pressure 170.35 oC
é A (T - T ) 1.25 ù Relieving Pressure, P1 15.58 kg/cm2A
w 1
W = 0.1406 ´ Mw ´ P1 ´ ê ú
Relieving Temperature, T1
ê T11.1506 ú 256.15 oC
ë û
Normal Operating Pressure, Pn 10.10 kg/cm2A
Normal Operating Temp., Tn 70.00 oC
Max. Vessel Wall Temp., Tw 593.33 oC
Molecular Weight, MW 28.85
Relief Load 1009.79 kg/hr
TION

: FOR GASSY SYSTEM CALCULATION FOR (WETTED WESSEL): FOR TEMPERATED SYSTEM (MIXED PH

Q= 269073.146 btu/hr
D= 0.95 m H= 2.1 m
A= 8.22409734 m2
6.27 ft
4.59 ft Safety Factor = 9.04650708 m2 97.3757880052 ft2
6.23 ft
Hvl = 37.38 Btu/lb Mass Heat Vaporazies Liquid (from Hysys)
W= 7198.31853 lb/hr

176.03 ft2

171.00 psig
338.63 oF
206.91 psig
493.07 oF
129 psig
158.00 oF
1100.00 oF
28.85
2226.23 lb/hr
ED SYSTEM (MIXED PHASED)
Conversion Of SCFM To ACFM

Inputs

Pressure 38.50 Psig


53.20 Psia
Temperature 89.7 °F
549.67 °R
Molecular Weight 22.85 lb/lbmol
Volumetric Flow Rate 15.000 MMSCFD
10416.6666666667 SCFM
Calculations

Standard Pressure 14.5 Psia


Standard Temperature 32 °F
492 °R
Absolute Pressure 53.2 Psia
Temperature 549.7 °R
R 10.73159 ft3·psi/ °R lb-mol
Density 0.2060668003 lb / ft3

Result

ACFM 3171.9188564654 ACFM


52.8653142744 ft3/ sec
4567563.1533101 CFD
129338.772299652 M3/D
5389.1155124855 M3/hr Flowrate
Density (kg/m3) 3.22932 17403.1785067796 Kg/Hr Mass Flow
38367.3953996165 Lb/Hr
PSV LOAD CALCULATION
PSV No. : 01 Receiving Filter Separator

CAUSE : Open External Fire ---> Vapor Expansion

CALCULATION: CALCULATION FOR (UNWETTED WESSEL): FOR GASSY SYSTEM

Sketch Vessel diameter 3000 mm


Vessel height exposed to fire 500.0 mm
Height of flame from grade 1000 mm

Head type: (1) 2:1 ellipsoidal


6500 mm (2) hemisphere
your choice is (1 or 2) = 1

Area exposed to fire 24.33 m2


500 mm

GROUND

Set Pressure 9.19 kg/cm2A


Temp. @ Set Pressure -182.22 oC
é A (T - T ) 1.25 ù Relieving Pressure, P1 10.90 kg/cm2A
w 1
W = 0.1406 ´ Mw ´ P1 ´ ê ú
Relieving Temperature, T1
ê T11.1506 ú -165.24 oC
ë û
Normal Operating Pressure, Pn 11.23 kg/cm2A
Normal Operating Temp., Tn -162.00 oC
Max. Vessel Wall Temp., Tw 593.33 oC
Molecular Weight, MW 18.12
Relief Load 17077.89 kg/hr
TION

: FOR GASSY SYSTEM CALCULATION FOR (WETTED WESSEL): FOR TEMPERATED SYSTEM (MIXED PH

Q= 6085147.92 btu/hr
D= 23.1 m H= 23.1 m
A= 368.804756 m2
9.84 ft
1.64 ft Safety Factor = 405.685232 m2 4366.759324753 ft2
3.28 ft (x110%)
Hvl = 110.1 Btu/lb Latent heat of vaporization (from Hysys)
W= 55269.2817 lb/hr

Relief load = 27.7444474 MMSCFD


Safety Factor = 30.5188921 MMSCFD
261.91 ft2 (x110%)

116.03 psig
-295.99 oF
140.40 psig
-265.42 oF
145.04 psig
-259.60 oF
1100.00 oF
18.12
37650.50 lb/hr
ED SYSTEM (MIXED PHASED)
PSV CALCULATION AND R

DOCUMENT NO.
PEMBANGUNAN TERMINAL LPG
ENG-DED-028-TPT-CAL-008 BELAWAN

PSV SIZING

1 Design Basis

Refference P&ID =
PSV Tag No. =
Scenario Sizing Basis =
Type PSV =
Fluid =
Phase =

Relief Rate, W =
Setting Pressure, P0 =
Setting Temperature =
Relief Temperature =
Back Pressure, P2 =

Molucular Weight, MW =
Compressibility Factor, Z =
k = Cp/Cv =

2 Calculation
Overpressure / Accumulation =
Relieving Pressure, P1 =
Back Pressure Ratio ᴨa, P2/P0 =
Critical Flow Pressure, Pcf =
Kb =
Kd =
Kc =
C =
Use E.q Critcal Flow to calculate A orrifice
A calculation =
3 Summary
Selected Orifice Area =
Orrifice Designation =
Rated Flow (W rated) =

Size Inlet =
Size Outlet =
Inlet Rating =
Outlet Rating =
CALCULATION AND REPORT

REV:
UNAN TERMINAL LPG PRESSURIZED PAGES:
BELAWAN 3 OF 10

PSV SIZING

BLW-PID-10-004-A3 For Outlet 200-T-01


PSV-01-1
FIRE CASE ; as governing case
CONVENTIONAL P2/P0 = 0.00 %
LPG
Vapor

38,367.40 lb/hr
256.02 psig = 270.72 psia
140.00 F = 599.67 R
212.00 F = 671.67 R
0.00 psig = 14.70 psia

51.11
0.070
1.060 (Table 7 Api 520)

121.00 %
309.78 psig = 324.48 psia
0.00 %
192.49 psia ; E.q. 3.1 Critical Flow (P2 ≤ Pcf)
1.00
0.975 ; for preeliminary sizing
1.00
365.00 ; see figure 32 (API 520)

0.319 in2
26.00 in2
; as API 526
T
3,130,331.47 lb/hr

8.00 in
10.00 in
300#
150#
REV:
PAGES:
3 OF 10

Flow (P2 ≤ Pcf)


PSV CALCULATION AND R

DOCUMENT NO.
PEMBANGUNAN TERMINAL LPG
ENG-DED-028-TPT-CAL-008 BELAWAN

PSV SIZING

1 Design Basis

Refference P&ID =
PSV Tag No. =
Scenario Sizing Basis =
Type PSV =
Fluid =
Phase =

Relief Rate, W =
Setting Pressure, P0 =
Setting Temperature =
Relief Temperature =
Back Pressure, P2 =

Molucular Weight, MW =
Compressibility Factor, Z =
k = Cp/Cv =

2 Calculation
Overpressure / Accumulation =
Relieving Pressure, P1 =
Back Pressure Ratio ᴨa, P2/P0 =
Critical Flow Pressure, Pcf =
Kb =
Kd =
Kc =
C =
Use E.q Critcal Flow to calculate A orrifice
A calculation =
3 Summary
Selected Orifice Area =
Orrifice Designation =
Rated Flow (W rated) =

Size Inlet =
Size Outlet =
Inlet Rating =
Outlet Rating =
CALCULATION AND REPORT

REV:
UNAN TERMINAL LPG PRESSURIZED PAGES:
BELAWAN 4 OF 10

PSV SIZING

BLW-PID-10-004-A3 For Outlet 200-T-01


PSV-01-2
FIRE CASE ; as governing case
CONVENTIONAL P2/P0 = 0.00 %
LPG
Vapor

38,367.40 lb/hr
256.02 psig = 270.72 psia
140.00 F = 599.67 R
212.00 F = 671.67 R
0.00 psig = 14.70 psia

51.11
0.070
1.060 (Table 7 Api 520)

121.00 %
309.78 psig = 324.48 psia
0.00 %
192.49 psia ; E.q. 3.1 Critical Flow (P2 ≤ Pcf)
1.00
0.975 ; for preeliminary sizing
1.00
365.00 ; see figure 32 (API 520)

0.319 in2
26.000 in2
; as API 526
T
3,130,331.47 lb/hr

8.00 in
10.00 in
300#
150#
REV:
PAGES:
4 OF 10

Flow (P2 ≤ Pcf)


PSV DATASHE

DOCUMENT NO. PEMBANGUNAN TERMINAL L


ENG-DED-028-TPT-DSH-008 BELAWAN

OPERATING CONDITIONS
PSV Tag No. :
Fluid :
Phase :
Scenario :
Type PSV :
Flow rate (Relief Load) :
Setting Temperature :
Set Pressure, P0 :
Relief Pressure, P1 :
Back Pressure P2 :
Back Pressure Ratio, P2/P0 :
Allowable Overpressure :
A Orrifice Calculation :

SUMMARY
Relieve Case Rated Flow (lb/hr) A Orrifice Calculation A Orrifice Effective
FIRE CASE 3,130,331.47 0.319 26.00

:
CONNECTION :
Inlet Size :
Inlet Rating :
Outlet Size :
Outlet Rating :
Calculated Orifice Area :
Selected Effective Orifice Area :
Orifice Designation (Letter) :

Notes :
1. API Standart 526 provides standard effective orifice area in terms of letter designations.
PSV DATASHEET

GUNAN TERMINAL LPG PRESSURIZED REV:


PAGES:
BELAWAN 3 OF 8

PSV-01-1/01-2
LPG
Vapor
FIRE CASE
CONVENTIONAL
38,367.40 (lb/hr)
140.00 (Fo)
256.02 psig
309.78 psig
0.00 psig
0.00 %
121 %
0.319 inch2

A Orrifice Effective Type Orrifice Designation (NOTE 1)


26.00
T

8.0 inch
300#
10.0 inch
#REF!
0.319 inch2
26.000 inch2
T

designations.
PSV CALCULATION AND R

DOCUMENT NO.
PEMBANGUNAN TERMINAL LPG
ENG-DED-028-TPT-CAL-008 BELAWAN

PSV SIZING

1 Design Basis

Refference P&ID =
PSV Tag No. =
Scenario Sizing Basis =
Type PSV =
Fluid =
Phase =

Relief Rate, W =
Setting Pressure, P0 =
Setting Temperature =
Relief Temperature =
Back Pressure, P2 =

Molucular Weight, MW =
Compressibility Factor, Z =
k = Cp/Cv =

2 Calculation
Overpressure / Accumulation =
Relieving Pressure, P1 =
Back Pressure Ratio ᴨa, P2/P0 =
Critical Flow Pressure, Pcf =
Kb =
Kd =
Kc =
C =
Use E.q Critcal Flow to calculate A orrifice
A calculation =
3 Summary
Selected Orifice Area =
Orrifice Designation =
Rated Flow (W rated) =

Size Inlet =
Size Outlet =
Inlet Rating =
Outlet Rating =
CALCULATION AND REPORT

REV:
UNAN TERMINAL LPG PRESSURIZED PAGES:
BELAWAN 5 OF 10

PSV SIZING

BLW-PID-10-004-A3 For Outlet 200-T-02


PSV-02-1
FIRE CASE ; as governing case
CONVENTIONAL P2/P0 = 0.00 %
LPG
Vapor

38,367.40 lb/hr
256.02 psig = 270.72 psia
140.00 F = 599.67 R
212.00 F = 671.67 R
0.00 psig = 14.70 psia

51.11
0.070
1.060 (Table 7 Api 520)

121.00 %
309.78 psig = 324.48 psia
0.00 %
192.49 psia ; E.q. 3.1 Critical Flow (P2 ≤ Pcf)
1.00
0.975 ; for preeliminary sizing
1.00
365.00 ; see figure 32 (API 520)

0.319 in2
26.00 in2
; as API 526
T
3,130,331.47 lb/hr

8.00 in
10.00 in
300#
150#
REV:
PAGES:
5 OF 10

Flow (P2 ≤ Pcf)


PSV CALCULATION AND R

DOCUMENT NO.
PEMBANGUNAN TERMINAL LPG
ENG-DED-028-TPT-CAL-008 BELAWAN

PSV SIZING

1 Design Basis

Refference P&ID =
PSV Tag No. =
Scenario Sizing Basis =
Type PSV =
Fluid =
Phase =

Relief Rate, W =
Setting Pressure, P0 =
Setting Temperature =
Relief Temperature =
Back Pressure, P2 =

Molucular Weight, MW =
Compressibility Factor, Z =
k = Cp/Cv =

2 Calculation
Overpressure / Accumulation =
Relieving Pressure, P1 =
Back Pressure Ratio ᴨa, P2/P0 =
Critical Flow Pressure, Pcf =
Kb =
Kd =
Kc =
C =
Use E.q Critcal Flow to calculate A orrifice
A calculation =
3 Summary
Selected Orifice Area =
Orrifice Designation =
Rated Flow (W rated) =

Size Inlet =
Size Outlet =
Inlet Rating =
Outlet Rating =
CALCULATION AND REPORT

REV:
UNAN TERMINAL LPG PRESSURIZED PAGES:
BELAWAN 6 OF 10

PSV SIZING

BLW-PID-10-004-A3 For Outlet 200-T-02


PSV-02-2
FIRE CASE ; as governing case
CONVENTIONAL P2/P0 = 0.00 %
LPG
Vapor

38,367.40 lb/hr
256.02 psig = 270.72 psia
140.00 F = 599.67 R
212.00 F = 671.67 R
0.00 psig = 14.70 psia

51.11
0.070
1.060 (Table 7 Api 520)

121.00 %
309.78 psig = 324.48 psia
0.00 %
192.49 psia ; E.q. 3.1 Critical Flow (P2 ≤ Pcf)
1.00
0.975 ; for preeliminary sizing
1.00
365.00 ; see figure 32 (API 520)

0.319 in2
26.00 in2
; as API 526
T
3,130,331.47 lb/hr

8.00 in
10.00 in
300#
150#
REV:
PAGES:
6 OF 10

Flow (P2 ≤ Pcf)


PSV DATASHEE

DOCUMENT NO. PEMBANGUNAN TERMINAL LP


ENG-DED-028-TPT-DSH-008 BELAWAN

OPERATING CONDITIONS
PSV Tag No. :
Fluid :
Phase :
Scenario :
Type PSV :
Flow rate :
Setting Temperature :
Set Pressure, P0 :
Relieve Pressure, P1 :
Back Pressure P2 :
Back Pressure Ratio, P2/P0 :
Allowable Overpressure :
A Orrifice Calculation :

SUMMARY
Relieve Case Rated Flow (lb/hr) A Orrifice Calculation A Orrifice Effective
FIRE CASE 3,130,331.47 0.319 26.000

:
CONNECTION :
Inlet Size :
Inlet Rating :
Outlet Size :
Outlet Rating :
Calculated Orifice Area :
Selected Effective Orifice Area :
Orifice Designation (Letter) :

Notes :
1. API Standart 526 provides standard effective orifice area in terms of letter designations.
PSV DATASHEET

UNAN TERMINAL LPG PRESSURIZED REV:


PAGES:
BELAWAN 4 OF 8

PSV-02-1/02-2
LPG
Vapor
FIRE CASE
CONVENTIONAL
38,367.40 (lb/hr)
140.00 (Fo)
256.02 psig
#REF! psig
0.00 psig
0.00 %
121 %
0.319 inch2

A Orrifice Effective Type Orrifice Designation (NOTE 1)


26.000
T

8.0 inch
300#
10.0 inch
#REF!
0.319 inch2
26.000 inch2
T

designations.
PSV CALCULATION AND R

DOCUMENT NO.
PEMBANGUNAN TERMINAL LPG
ENG-DED-028-TPT-CAL-008 BELAWAN

PSV SIZING

1 Design Basis

Refference P&ID =
PSV Tag No. =
Scenario Sizing Basis =
Type PSV =
Fluid =
Phase =

Relief Rate, W =
Setting Pressure, P0 =
Setting Temperature =
Relief Temperature =
Back Pressure, P2 =

Molucular Weight, MW =
Compressibility Factor, Z =
k = Cp/Cv =

2 Calculation
Overpressure / Accumulation =
Relieving Pressure, P1 =
Back Pressure Ratio ᴨa, P2/P0 =
Critical Flow Pressure, Pcf =
Kb =
Kd =
Kc =
C =
Use E.q Critcal Flow to calculate A orrifice
A calculation =
3 Summary
Selected Orifice Area =
Orrifice Designation =
Rated Flow (W rated) =

Size Inlet =
Size Outlet =
Inlet Rating =
Outlet Rating =
CALCULATION AND REPORT

REV:
UNAN TERMINAL LPG PRESSURIZED PAGES:
BELAWAN 5 OF 10

PSV SIZING

BLW-PID-10-004-A3 For Outlet 200-T-03


PSV-03-1
FIRE CASE ; as governing case
CONVENTIONAL P2/P0 = 0.00 %
LPG
Vapor

38,367.40 lb/hr
256.02 psig = 270.72 psia
140.00 F = 599.67 R
212.00 F = 671.67 R
0.00 psig = 14.70 psia

51.11
0.070
1.060 (Table 7 Api 520)

121.00 %
309.78 psig = 324.48 psia
0.00 %
192.49 psia ; E.q. 3.1 Critical Flow (P2 ≤ Pcf)
1.00
0.975 ; for preeliminary sizing
1.00
365.00 ; see figure 32 (API 520)

0.319 in2
26.00 in2
; as API 526
T
3,130,331.47 lb/hr

8.00 in
10.00 in
300#
150#
REV:
PAGES:
5 OF 10

Flow (P2 ≤ Pcf)


PSV CALCULATION AND R

DOCUMENT NO.
PEMBANGUNAN TERMINAL LPG
ENG-DED-028-TPT-CAL-008 BELAWAN

PSV SIZING

1 Design Basis

Refference P&ID =
PSV Tag No. =
Scenario Sizing Basis =
Type PSV =
Fluid =
Phase =

Relief Rate, W =
Setting Pressure, P0 =
Setting Temperature =
Relief Temperature =
Back Pressure, P2 =

Molucular Weight, MW =
Compressibility Factor, Z =
k = Cp/Cv =

2 Calculation
Overpressure / Accumulation =
Relieving Pressure, P1 =
Back Pressure Ratio ᴨa, P2/P0 =
Critical Flow Pressure, Pcf =
Kb =
Kd =
Kc =
C =
Use E.q Critcal Flow to calculate A orrifice
A calculation =
3 Summary
Selected Orifice Area =
Orrifice Designation =
Rated Flow (W rated) =

Size Inlet =
Size Outlet =
Inlet Rating =
Outlet Rating =
CALCULATION AND REPORT

REV:
UNAN TERMINAL LPG PRESSURIZED PAGES:
BELAWAN 6 OF 10

PSV SIZING

BLW-PID-10-004-A3 For Outlet 200-T-03


PSV-03-2
FIRE CASE ; as governing case
CONVENTIONAL P2/P0 = 0.00 %
LPG
Vapor

38,367.40 lb/hr
256.02 psig = 270.72 psia
140.00 F = 599.67 R
212.00 F = 671.67 R
0.00 psig = 14.70 psia

51.11
0.070
1.060 (Table 7 Api 520)

121.00 %
309.78 psig = 324.48 psia
0.00 %
192.49 psia ; E.q. 3.1 Critical Flow (P2 ≤ Pcf)
1.00
0.975 ; for preeliminary sizing
1.00
365.00 ; see figure 32 (API 520)

0.319 in2
26.00 in2
; as API 526
T
3,130,331.47 lb/hr

8.00 in
10.00 in
300#
150#
REV:
PAGES:
6 OF 10

Flow (P2 ≤ Pcf)


PSV DATASHEE

DOCUMENT NO. PEMBANGUNAN TERMINAL LP


ENG-DED-028-TPT-DSH-008 BELAWAN

OPERATING CONDITIONS
PSV Tag No. :
Fluid :
Phase :
Scenario :
Type PSV :
Flow rate :
Setting Temperature :
Set Pressure, P0 :
Relieve Pressure, P1 :
Back Pressure P2 :
Back Pressure Ratio, P2/P0 :
Allowable Overpressure :
A Orrifice Calculation :

SUMMARY
Relieve Case Rated Flow (lb/hr) A Orrifice Calculation A Orrifice Effective
FIRE CASE 3,130,331.47 0.319 26.000

:
CONNECTION :
Inlet Size :
Inlet Rating :
Outlet Size :
Outlet Rating :
Calculated Orifice Area :
Selected Effective Orifice Area :
Orifice Designation (Letter) :

Notes :
1. API Standart 526 provides standard effective orifice area in terms of letter designations.
PSV DATASHEET

UNAN TERMINAL LPG PRESSURIZED REV:


PAGES:
BELAWAN 4 OF 8

PSV-03-1/03-2
LPG
Vapor
FIRE CASE
CONVENTIONAL
38,367.40 (lb/hr)
140.00 (Fo)
256.02 psig
#REF! psig
0.00 psig
0.00 %
121 %
0.319 inch2

A Orrifice Effective Type Orrifice Designation (NOTE 1)


26.000
T

8.0 inch
300#
10.0 inch
#REF!
0.319 inch2
26.000 inch2
T

designations.
PSV CALCULATION AND R

DOCUMENT NO.
PEMBANGUNAN TERMINAL LPG
ENG-DED-028-TPT-CAL-008 BELAWAN

PSV SIZING

1 Design Basis

Refference P&ID =
PSV Tag No. =
Scenario Sizing Basis =
Type PSV =
Fluid =
Phase =

Relief Rate, W =
Setting Pressure, P0 =
Setting Temperature =
Relief Temperature =
Back Pressure, P2 =

Molucular Weight, MW =
Compressibility Factor, Z =
k = Cp/Cv =

2 Calculation
Overpressure / Accumulation =
Relieving Pressure, P1 =
Back Pressure Ratio ᴨa, P2/P0 =
Critical Flow Pressure, Pcf =
Kb =
Kd =
Kc =
C =
Use E.q Critcal Flow to calculate A orrifice
A calculation =
3 Summary
Selected Orifice Area =
Orrifice Designation =
Rated Flow (W rated) =

Size Inlet =
Size Outlet =
Inlet Rating =
Outlet Rating =
CALCULATION AND REPORT

REV:
UNAN TERMINAL LPG PRESSURIZED PAGES:
BELAWAN 5 OF 10

PSV SIZING

BLW-PID-10-004-A3 For Outlet 200-T-04


PSV-04-1
FIRE CASE ; as governing case
CONVENTIONAL P2/P0 = 0.00 %
LPG
Vapor

38,367.40 lb/hr
256.02 psig = 270.72 psia
140.00 F = 599.67 R
212.00 F = 671.67 R
0.00 psig = 14.70 psia

51.11
0.070
1.060 (Table 7 Api 520)

121.00 %
309.78 psig = 324.48 psia
0.00 %
192.49 psia ; E.q. 3.1 Critical Flow (P2 ≤ Pcf)
1.00
0.975 ; for preeliminary sizing
1.00
365.00 ; see figure 32 (API 520)

0.319 in2
26.00 in2
; as API 526
T
3,130,331.47 lb/hr

8.00 in
10.00 in
300#
150#
REV:
PAGES:
5 OF 10

Flow (P2 ≤ Pcf)


PSV CALCULATION AND R

DOCUMENT NO.
PEMBANGUNAN TERMINAL LPG
ENG-DED-028-TPT-CAL-008 BELAWAN

PSV SIZING

1 Design Basis

Refference P&ID =
PSV Tag No. =
Scenario Sizing Basis =
Type PSV =
Fluid =
Phase =

Relief Rate, W =
Setting Pressure, P0 =
Setting Temperature =
Relief Temperature =
Back Pressure, P2 =

Molucular Weight, MW =
Compressibility Factor, Z =
k = Cp/Cv =

2 Calculation
Overpressure / Accumulation =
Relieving Pressure, P1 =
Back Pressure Ratio ᴨa, P2/P0 =
Critical Flow Pressure, Pcf =
Kb =
Kd =
Kc =
C =
Use E.q Critcal Flow to calculate A orrifice
A calculation =
3 Summary
Selected Orifice Area =
Orrifice Designation =
Rated Flow (W rated) =

Size Inlet =
Size Outlet =
Inlet Rating =
Outlet Rating =
CALCULATION AND REPORT

REV:
UNAN TERMINAL LPG PRESSURIZED PAGES:
BELAWAN 6 OF 10

PSV SIZING

BLW-PID-10-004-A3 For Outlet 200-T-04


PSV-04-2
FIRE CASE ; as governing case
CONVENTIONAL P2/P0 = 0.00 %
LPG
Vapor

38,367.40 lb/hr
256.02 psig = 270.72 psia
140.00 F = 599.67 R
212.00 F = 671.67 R
0.00 psig = 14.70 psia

51.11
0.070
1.060 (Table 7 Api 520)

121.00 %
309.78 psig = 324.48 psia
0.00 %
192.49 psia ; E.q. 3.1 Critical Flow (P2 ≤ Pcf)
1.00
0.975 ; for preeliminary sizing
1.00
365.00 ; see figure 32 (API 520)

0.319 in2
26.00 in2
; as API 526
T
3,130,331.47 lb/hr

8.00 in
10.00 in
300#
150#
REV:
PAGES:
6 OF 10

Flow (P2 ≤ Pcf)


PSV DATASHEE

DOCUMENT NO. PEMBANGUNAN TERMINAL LP


ENG-DED-028-TPT-DSH-008 BELAWAN

OPERATING CONDITIONS
PSV Tag No. :
Fluid :
Phase :
Scenario :
Type PSV :
Flow rate :
Setting Temperature :
Set Pressure, P0 :
Relieve Pressure, P1 :
Back Pressure P2 :
Back Pressure Ratio, P2/P0 :
Allowable Overpressure :
A Orrifice Calculation :

SUMMARY
Relieve Case Rated Flow (lb/hr) A Orrifice Calculation A Orrifice Effective
FIRE CASE 3,130,331.47 0.319 26.000

:
CONNECTION :
Inlet Size :
Inlet Rating :
Outlet Size :
Outlet Rating :
Calculated Orifice Area :
Selected Effective Orifice Area :
Orifice Designation (Letter) :

Notes :
1. API Standart 526 provides standard effective orifice area in terms of letter designations.
PSV DATASHEET

UNAN TERMINAL LPG PRESSURIZED REV:


PAGES:
BELAWAN 4 OF 8

PSV-04-1/04-2
LPG
Vapor
FIRE CASE
CONVENTIONAL
38,367.40 (lb/hr)
140.00 (Fo)
256.02 psig
#REF! psig
0.00 psig
0.00 %
121 %
0.319 inch2

A Orrifice Effective Type Orrifice Designation (NOTE 1)


26.000
T

8.0 inch
300#
10.0 inch
#REF!
0.319 inch2
26.000 inch2
T

designations.
PSV LOAD CALCULATION
PSV No. : 01 Receiving Filter Separator

CAUSE : Open External Fire ---> Vapor Expansion

CALCULATION: CALCULATION FOR (UNWETTED WESSEL): FOR GASSY SYSTEM

Sketch Vessel diameter 1000 mm


Vessel height exposed to fire 1500.0 mm
Height of flame from grade 2000 mm

Head type: (1) 2:1 ellipsoidal


2000 mm (2) hemisphere
your choice is (1 or 2) = 1

Area exposed to fire 6.89 m2


500 mm

GROUND

Set Pressure 13.03 kg/cm2A


Temp. @ Set Pressure 132.24 oC
é A (T - T ) 1.25 ù Relieving Pressure, P1 15.55 kg/cm2A
w 1
W = 0.1406 ´ Mw ´ P1 ´ ê ú
Relieving Temperature, T1
ê T11.1506 ú 210.65 oC
ë û
Normal Operating Pressure, Pn 11.03 kg/cm2A
Normal Operating Temp., Tn 70.00 oC
Max. Vessel Wall Temp., Tw 593.33 oC
Molecular Weight, MW 28.85
Relief Load 552.35 kg/hr
TION

: FOR GASSY SYSTEM CALCULATION FOR (WETTED WESSEL): FOR TEMPERATED SYSTEM (MIXED PH

Q= 6085147.92 btu/hr
D= 23.1 m H= 23.1 m
A= 368.804756 m2
3.28 ft
4.92 ft Safety Factor = 405.685232 m2 4366.759324753 ft2
6.56 ft (x110%)
Hvl = 110.1 Btu/lb Latent heat of vaporization (from Hysys)
W= 55269.2817 lb/hr

Relief load = 27.7444474 MMSCFD


Safety Factor = 30.5188921 MMSCFD
74.19 ft2 (x110%)

170.68 psig
270.03 oF
206.52 psig
411.18 oF
142.23 psig
158.00 oF
1100.00 oF
28.85
1217.74 lb/hr
ED SYSTEM (MIXED PHASED)
PSV CALCULATION AND R

DOCUMENT NO.
PEMBANGUNAN TERMINAL LPG
ENG-DED-028-TPT-CAL-008 BELAWAN

PSV SIZING

1 Design Basis

Refference P&ID =
PSV Tag No. =
Scenario Sizing Basis =
Type PSV =
Fluid =
Phase =

Relief Rate, W =
Setting Pressure, P0 =
Setting Temperature =
Relief Temperature =
Back Pressure, P2 =

Molucular Weight, MW =
Compressibility Factor, Z =
k = Cp/Cv =

2 Calculation
Overpressure / Accumulation =
Relieving Pressure, P1 =
Back Pressure Ratio ᴨa, P2/P0 =
Critical Flow Pressure, Pcf =
Kb =
Kd =
Kc =
C =
Use E.q Critcal Flow to calculate A orrifice
A calculation =
3 Summary
Selected Orifice Area =
Orrifice Designation =
Rated Flow (W rated) =

Size Inlet =
Size Outlet =
Inlet Rating =
Outlet Rating =
CALCULATION AND REPORT

REV:
UNAN TERMINAL LPG PRESSURIZED PAGES:
BELAWAN 8 OF 10

PSV SIZING

BLW-PID-10-007-A3 For Utility Air Receiver


PSV-01
FIRE CASE ; as governing case
CONVENTIONAL P2/P0 = 0.00 %
Utility Air
Gas Expansion

1217.74 lb/hr
170.68 psig = 185.38 psia
158.00 F = 617.67 R
685.04 F = 1144.71 R
0.00 psig = 14.70 psia

28.85
1.000
1.411 (Table 7 Api 520)

121.00 %
206.52 psig = 221.22 psia
0.00 %
116.46 psia ; E.q. 3.1 Critical Flow (P2 ≤ Pcf)
1.00
0.975 ; for preeliminary sizing
1.00
350.00 ; see figure 32 (API 520)

0.102 in2
0.110 in2
; as API 526
D
1318.32 lb/hr

1.00 in
2.00 in
150#
150#
REV:
PAGES:
8 OF 10

Flow (P2 ≤ Pcf)


PSV DATASHE

DOCUMENT NO. PEMBANGUNAN TERMINAL L


ENG-DED-028-TPT-DSH-008 BELAWAN

OPERATING CONDITIONS
PSV Tag No. :
Fluid :
Phase :
Scenario :
Type PSV :
Flow rate :
Setting Temperature :
Set Pressure, P0 :
Relieve Pressure, P1 :
Back Pressure P2 :
Back Pressure Ratio, P2/P0 :
Allowable Overpressure :
A Orrifice Calculation :

SUMMARY
Relieve Case Rated Flow (lb/hr) A Orrifice Calculation A Orrifice Effective
FIRE CASE 1318.32 0.102 0.110

:
CONNECTION :
Inlet Size :
Inlet Rating :
Outlet Size :
Outlet Rating :
Calculated Orifice Area :
Selected Effective Orifice Area :
Orifice Designation (Letter) :

Notes :
1. API Standart 526 provides standard effective orifice area in terms of letter designations.
PSV DATASHEET

GUNAN TERMINAL LPG PRESSURIZED REV:


PAGES:
BELAWAN 6 OF 8

PSV-01
Utility Air
Gas Expansion
FIRE CASE
CONVENTIONAL
1217.74 (lb/hr)
158.00 (Fo)
170.68 psig
206.52 psig
0.00 psig
0.00 %
121 %
0.102 inch2

A Orrifice Effective Type Orrifice Designation (NOTE 1)


0.110
D

1.0 inch
150#
2.0 inch
150#
0.102 inch2
0.110 inch2
D

designations.
PSV LOAD CALCULATION
PSV No. : 01 Receiving Filter Separator

CAUSE : Open External Fire ---> Vapor Expansion

CALCULATION: CALCULATION FOR (UNWETTED WESSEL): FOR GASSY SYSTEM

Sketch Vessel diameter 1910 mm


Vessel height exposed to fire 1500.0 mm
Height of flame from grade 2000 mm

Head type: (1) 2:1 ellipsoidal


3820 mm (2) hemisphere
your choice is (1 or 2) = 1

Area exposed to fire 16.95 m2


500 mm

GROUND

Set Pressure 13.03 kg/cm2A


Temp. @ Set Pressure 172.66 oC
é A (T - T ) 1.25 ù Relieving Pressure, P1 15.55 kg/cm2A
w 1
W = 0.1406 ´ Mw ´ P1 ´ ê ú
Relieving Temperature, T1
ê T11.1506 ú 258.89 oC
ë û
Normal Operating Pressure, Pn 10.03 kg/cm2A
Normal Operating Temp., Tn 70.00 oC
Max. Vessel Wall Temp., Tw 593.33 oC
Molecular Weight, MW 28.85
Relief Load 1029.18 kg/hr
TION

: FOR GASSY SYSTEM CALCULATION FOR (WETTED WESSEL): FOR TEMPERATED SYSTEM (MIXED PH

Q= 6085147.92 btu/hr
D= 23.1 m H= 23.1 m
A= 368.804756 m2
6.27 ft
4.92 ft Safety Factor = 405.685232 m2 4366.759324753 ft2
6.56 ft (x110%)
Hvl = 110.1 Btu/lb Latent heat of vaporization (from Hysys)
W= 55269.2817 lb/hr

Relief load = 27.7444474 MMSCFD


Safety Factor = 30.5188921 MMSCFD
182.49 ft2 (x110%)

170.68 psig
342.79 oF
206.52 psig
498.01 oF
128.01 psig
158.00 oF
1100.00 oF
28.85
2268.96 lb/hr
ED SYSTEM (MIXED PHASED)
PSV CALCULATION AND R

DOCUMENT NO.
PEMBANGUNAN TERMINAL LPG
ENG-DED-028-TPT-CAL-008 BELAWAN

PSV SIZING

1 Design Basis

Refference P&ID =
PSV Tag No. =
Scenario Sizing Basis =
Type PSV =
Fluid =
Phase =

Relief Rate, W =
Setting Pressure, P0 =
Setting Temperature =
Relief Temperature =
Back Pressure, P2 =

Molucular Weight, MW =
Compressibility Factor, Z =
k = Cp/Cv =

2 Calculation
Overpressure / Accumulation =
Relieving Pressure, P1 =
Back Pressure Ratio ᴨa, P2/P0 =
Critical Flow Pressure, Pcf =
Kb =
Kd =
Kc =
C =
Use E.q Critcal Flow to calculate A orrifice
A calculation =
3 Summary
Selected Orifice Area =
Orrifice Designation =
Rated Flow (W rated) =

Size Inlet =
Size Outlet =
Inlet Rating =
Outlet Rating =
CALCULATION AND REPORT

REV:
UNAN TERMINAL LPG PRESSURIZED PAGES:
BELAWAN 9 OF 10

PSV SIZING

BLW-PID-10-007-A3 For Instrument Air Receiver


PSV-02
FIRE CASE ; as governing case
CONVENTIONAL P2/P0 = 0.00 %
Instrument Air
Gas Expansion

2268.96 lb/hr
170.68 psig = 185.38 psia
158.00 F = 617.67 R
572.00 F = 1031.67 R
0.00 psig = 14.70 psia

28.85
1.000
1.411 (Table 7 Api 520)

121.00 %
206.52 psig = 221.22 psia
0.00 %
116.46 psia ; E.q. 3.1 Critical Flow (P2 ≤ Pcf)
1.00
0.975 ; for preeliminary sizing
1.00
350.00 ; see figure 32 (API 520)

0.180 in2
0.196 in2
; as API 526
E
2474.35 lb/hr

1.00 in
2.00 in
150#
150#
REV:
PAGES:
9 OF 10

Flow (P2 ≤ Pcf)


PSV DATASHE

DOCUMENT NO. PEMBANGUNAN TERMINAL L


ENG-DED-028-TPT-CAL-008 BELAWAN

OPERATING CONDITIONS
PSV Tag No. :
Fluid :
Phase :
Scenario :
Type PSV :
Flow rate :
Setting Temperature :
Set Pressure, P0 :
Relieve Pressure, P1 :
Back Pressure P2 :
Back Pressure Ratio, P2/P0 :
Allowable Overpressure :
A Orrifice Calculation :

SUMMARY
Relieve Case Rated Flow (lb/hr) A Orrifice Calculation A Orrifice Effective
FIRE CASE 2474.35 0.180 0.196

:
CONNECTION :
Inlet Size :
Inlet Rating :
Outlet Size :
Outlet Rating :
Calculated Orifice Area :
Selected Effective Orifice Area :
Orifice Designation (Letter) :

Notes :
1. API Standart 526 provides standard effective orifice area in terms of letter designations.
PSV DATASHEET

GUNAN TERMINAL LPG PRESSURIZED REV:


PAGES:
BELAWAN 7 OF 8

PSV-02
Instrument Air
Gas Expansion
FIRE CASE
CONVENTIONAL
2268.96 (lb/hr)
158.00 (Fo)
170.68 psig
206.52 psig
0.00 psig
0.00 %
121 %
0.180 inch2

A Orrifice Effective Type Orrifice Designation (NOTE 1)


0.196
E

1.0 inch
150#
2.0 inch
150#
0.180 inch2
0.196 inch2
E

designations.
CALCULATION SHEET
THERMAL CASE

JOB NO. :
PROJECT : PEMBANGUNAN TERMINAL LPG PRESSURIZED BELAWAN
CLIENT : PT Pertamina
SERVICE : LPG
PSV CASE : THERMAL RELIEF

EQUIPMENT TAG NO. : PID NO : BLW-PID-10-003-A3


EQUPMENT TAG NAME :
PSV TAG NO. : PSV - 01-2

Line Pipe
No Routing OD, in ID, in Length, ft
Number NPS
1 Inlet Jetty LPG Metering 16 15.92 15.250 393.70

Total Pipe Area Exposed

INPUT DATA
Normal operating pressure (Pn) ( psig )
Normal operating temperature (Tn) ( ºF )
Set pressure (psig)
Overpressure
Relieving pressure (psia)
Back pressure (psig)
HEAT ABSORBED
Heat radiation (Btu/hr/ft2)
(Refer to Project Design Basis on intensity of solar radiation is 300 Btu/hr/ft 2)
Heat transfer area (ft2)
Total heat absorbed (btu/hr)
THERMAL EXPANSION
Relieving temperature ( T1 ) ( ºF )
Molecular weight (MW)
Density lb/ft3
Viscosity (cP)
Specific gravity (SG)
API gravity (deg. API)
Cubical expansion coefficient (B) (Table C-1 API 520) (1/deg.F)
Coefficient for specific heat ratio ( C )
Specific heat (Cp) (Btu/lb.oF)
Specific heat ratio (Cp/Cv)
Relief load ( W ) (gpm)
(BFPD)
(lb/hr)
Back pressure correction factor ( Kb )
Valve discharge coeff. ( Kd )
Reynold Number
Viscosity coeff. ( Kv ) (Fig.32 API 520)
Required orifice area (A) ( in2 )
Selected orifice area ( in2 )
Selected orifice designation
Standard valve body size available (sq.in)
Rated Flowrate (lb/hr)

Calculation reference: API RP 520, Crosby Pressure Relief Valve Engineering Handbook
CALCULATION SHEET
THERMAL CASE

BLW-PID-10-003-A3

Pipe
Area, ft2
1641.30

1641.30

= 170.68
= 95.0
= 256.02
= 10%
= 296.32
= 25.60 (assumed)

= 300

= 1641.30
= 492389.01

= 140.0
= 51.11
= 32.28
= 0.1250
= 0.52
= 114.00
= 0.0009
= 384.2
= 0.7443
= 1.758
= 2.302
= 78.93
= 596.03
= 1.000
= 0.975
= 34059.79
= 0.991
= 0.002819
= 0.110
= D
= 1x2;1.5x2;1.5x2.5
= 7730

y Pressure Relief Valve Engineering Handbook


PROCESS DATA SHEET FOR PRESSURE SAFETY VALVE
Tag No. : Client : PT Pertamina
Equipment Name : Plant Location : Belawan, North Sumatera
PSV Tag No. : PSV - 01-2 No. of Unit : 1
P&ID No. :

PSV LOAD SUMMARY

RELIEF CONDITION UNIT Thermal Relief

PSV RELIEF LOAD CALCULATION RESULT


Required Relieved Load : lb/hr 596.03
- Vapour Load lb/hr -
- Liquid Load lb/hr 596.03
Molecular Weight 51.11
Specific Gravity :
- Vapour Phase -
- Liquid Phase 0.517
Operating Pressure psig 170.68
Set Pressure psig 256.02
Operating Temperature o
F 95
Relieving Temperature o
F 140.00
Total Back Pressure psig 25.60
% Allowable Overpressure % 10.0
Vapour Compressibility Factor 0.2126
Ratio of Specific Heat 1.7580
Mass Density :
- Overall Density lb/ft3 -
- Vapour Density lb/ft 3
-
- Liquid Density lb/ft 3
32.28
Viscosity : .
- Vapour Viscosity cP -
- Liquid Viscosity cP 0.1250
PRELIMINARY PSV AREA CALCULATION RESULT
Required PSV Area in2 0.00282
Selected PSV Orifice Area in 2
0.11
Selected PSV Letter Designation D
Valve orifice designation in x in 1D2
PSV Rated Relief Rate lb/hr 7730
Number of Operated PSV Required 1
PSV Type Conventional
VALVE
North Sumatera
CALCULATION SHEET
THERMAL CASE

JOB NO. :
PROJECT : PEMBANGUNAN TERMINAL LPG PRESSURIZED BELAWAN
CLIENT : PT Pertamina
SERVICE : LPG
PSV CASE : THERMAL RELIEF

EQUIPMENT TAG NO. : PID NO : BLW-PID-10-005-A3


EQUPMENT TAG NAME :
PSV TAG NO. : PSV -300

Line Pipe
No Routing OD, in ID, in Length, ft
Number NPS
1 Outlet LPG Truck Filling Pumps 12 12.67 12.000 393.70

Total Pipe Area Exposed

INPUT DATA
Normal operating pressure (Pn) ( psig )
Normal operating temperature (Tn) ( ºF )
Set pressure (psig)
Overpressure
Relieving pressure (psia)
Back pressure (psig)
HEAT ABSORBED
Heat radiation (Btu/hr/ft2)
(Refer to Project Design Basis on intensity of solar radiation is 300 Btu/hr/ft 2)
Heat transfer area (ft2)
Total heat absorbed (btu/hr)
THERMAL EXPANSION
Relieving temperature ( T1 ) ( ºF )
Molecular weight (MW)
Density lb/ft3
Viscosity (cP)
Specific gravity (SG)
API gravity (deg. API)
Cubical expansion coefficient (B) (Table C-1 API 520) (1/deg.F)
Coefficient for specific heat ratio ( C )
Specific heat (Cp) (Btu/lb.oF)
Specific heat ratio (Cp/Cv)
Relief load ( W ) (gpm)
(BFPD)
(lb/hr)
Back pressure correction factor ( Kb )
Valve discharge coeff. ( Kd )
Reynold Number
Viscosity coeff. ( Kv ) (Fig.32 API 520)
Required orifice area (A) ( in2 )
Selected orifice area ( in2 )
Selected orifice designation
Standard valve body size available (sq.in)
Rated Flowrate (lb/hr)

Calculation reference: API RP 520, Crosby Pressure Relief Valve Engineering Handbook
CALCULATION SHEET
THERMAL CASE

BLW-PID-10-005-A3

Pipe
Area, ft2
1306.32

1306.32

= 199.13
= 95.0
= 256.02
= 10%
= 296.32
= 25.60 (assumed)

= 300

= 1306.32
= 391895.14

= 140.0
= 51.11
= 33.29
= 0.1257
= 0.53
= 114.00
= 0.0009
= 384.2
= 0.7443
= 1.758
= 1.776
= 60.90
= 474.38
= 1.000
= 0.975
= 34937.90
= 0.991
= 0.002208
= 0.110
= D
= 1x2;1.5x2;1.5x2.5
= 7730

y Pressure Relief Valve Engineering Handbook


PROCESS DATA SHEET FOR PRESSURE SAFETY VALVE
Tag No. : Client : PT Pertamina
Equipment Name : Plant Location : Belawan, North Sumatera
PSV Tag No. : PSV -300 No. of Unit : 1
P&ID No. :

PSV LOAD SUMMARY

RELIEF CONDITION UNIT Thermal Relief

PSV RELIEF LOAD CALCULATION RESULT


Required Relieved Load : lb/hr 474.38
- Vapour Load lb/hr -
- Liquid Load lb/hr 474.38
Molecular Weight 51.11
Specific Gravity :
- Vapour Phase -
- Liquid Phase 0.534
Operating Pressure psig 199.13
Set Pressure psig 256.02
Operating Temperature o
F 95
Relieving Temperature o
F 140.00
Total Back Pressure psig 25.60
% Allowable Overpressure % 10.0
Vapour Compressibility Factor 0.2126
Ratio of Specific Heat 1.7580
Mass Density :
- Overall Density lb/ft3 -
- Vapour Density lb/ft 3
-
- Liquid Density lb/ft 3
33.29
Viscosity : .
- Vapour Viscosity cP -
- Liquid Viscosity cP 0.1257
PRELIMINARY PSV AREA CALCULATION RESULT
Required PSV Area in2 0.00221
Selected PSV Orifice Area in 2
0.11
Selected PSV Letter Designation D
Valve orifice designation in x in 1D2
PSV Rated Relief Rate lb/hr 7730
Number of Operated PSV Required 1
PSV Type Conventional
VALVE
North Sumatera
CALCULATION SHEET
THERMAL CASE

JOB NO. :
PROJECT : PEMBANGUNAN TERMINAL LPG PRESSURIZED BELAWAN
CLIENT : PT Pertamina
SERVICE : LPG
PSV CASE : THERMAL RELIEF

EQUIPMENT TAG NO. : PID NO : BLW-PID-10-006-A3


EQUPMENT TAG NAME :
PSV TAG NO. : PSV -300-01/02/03/04

Line Pipe
No Routing OD, in ID, in Length, ft
Number NPS
1 Outlet LPG Truck Filling Pumps 4 4.70 4.026 393.70

Total Pipe Area Exposed

INPUT DATA
Normal operating pressure (Pn) ( psig )
Normal operating temperature (Tn) ( ºF )
Set pressure (psig)
Overpressure
Relieving pressure (psia)
Back pressure (psig)
HEAT ABSORBED
Heat radiation (Btu/hr/ft2)
(Refer to Project Design Basis on intensity of solar radiation is 300 Btu/hr/ft 2)
Heat transfer area (ft2)
Total heat absorbed (btu/hr)
THERMAL EXPANSION
Relieving temperature ( T1 ) ( ºF )
Molecular weight (MW)
Density lb/ft3
Viscosity (cP)
Specific gravity (SG)
API gravity (deg. API)
Cubical expansion coefficient (B) (Table C-1 API 520) (1/deg.F)
Coefficient for specific heat ratio ( C )
Specific heat (Cp) (Btu/lb.oF)
Specific heat ratio (Cp/Cv)
Relief load ( W ) (gpm)
(BFPD)
(lb/hr)
Back pressure correction factor ( Kb )
Valve discharge coeff. ( Kd )
Reynold Number
Viscosity coeff. ( Kv ) (Fig.32 API 520)
Required orifice area (A) ( in2 )
Selected orifice area ( in2 )
Selected orifice designation
Standard valve body size available (sq.in)
Rated Flowrate (lb/hr)

Calculation reference: API RP 520, Crosby Pressure Relief Valve Engineering Handbook
CALCULATION SHEET
THERMAL CASE

BLW-PID-10-006-A3

Pipe
Area, ft2
484.43

484.43

= 199.13
= 95.0
= 256.02
= 10%
= 296.32
= 25.60 (assumed)

= 300

= 484.43
= 145329.59

= 140.0
= 51.11
= 33.29
= 0.1257
= 0.53
= 114.00
= 0.0009
= 384.2
= 0.7443
= 1.758
= 0.659
= 22.59
= 175.92
= 1.000
= 0.975
= 34937.90
= 0.991
= 0.000819
= 0.110
= D
= 1x2;1.5x2;1.5x2.5
= 7730

y Pressure Relief Valve Engineering Handbook


PROCESS DATA SHEET FOR PRESSURE SAFETY VALVE
Tag No. : Client : PT Pertamina
Equipment Name : Plant Location : Belawan, North Sumatera
PSV Tag No. : PSV -300-01/02/03/04 No. of Unit : 1
P&ID No. :

PSV LOAD SUMMARY

RELIEF CONDITION UNIT Thermal Relief

PSV RELIEF LOAD CALCULATION RESULT


Required Relieved Load : lb/hr 175.92
- Vapour Load lb/hr -
- Liquid Load lb/hr 175.92
Molecular Weight 51.11
Specific Gravity :
- Vapour Phase -
- Liquid Phase 0.534
Operating Pressure psig 199.13
Set Pressure psig 256.02
Operating Temperature o
F 95
Relieving Temperature o
F 140.00
Total Back Pressure psig 25.60
% Allowable Overpressure % 10.0
Vapour Compressibility Factor 0.2126
Ratio of Specific Heat 1.7580
Mass Density :
- Overall Density lb/ft3 -
- Vapour Density lb/ft 3
-
- Liquid Density lb/ft 3
33.29
Viscosity : .
- Vapour Viscosity cP -
- Liquid Viscosity cP 0.1257
PRELIMINARY PSV AREA CALCULATION RESULT
Required PSV Area in2 0.00082
Selected PSV Orifice Area in 2
0.11
Selected PSV Letter Designation D
Valve orifice designation in x in 1D2
PSV Rated Relief Rate lb/hr 7730
Number of Operated PSV Required 1
PSV Type Conventional
VALVE
North Sumatera
PSV CALCULATION AND R

DOCUMENT NO.
PEMBANGUNAN TERMINAL LPG
TELUK KABUNG PADA

PSV SIZING

1 Design Basis

Refference P&ID =
PSV Tag No. =
Scenario Sizing Basis =
Type PSV =
Fluid =
Phase =

Relief Rate, W =
Setting Pressure, P0 =
Setting Temperature =
Relief Temperature =
Back Pressure, P2 =

Molucular Weight, MW =
Compressibility Factor, Z =
k = Cp/Cv =

2 Calculation
Overpressure / Accumulation =
Relieving Pressure, P1 =
Back Pressure Ratio ᴨa, P2/P0 =
Critical Flow Pressure, Pcf =
Kb =
Kd =
Kc =
C =
Use E.q Critcal Flow to calculate A orrifice
A calculation =
3 Summary
Selected Orifice Area =
Orrifice Designation =

Selected Orifice Area =


Orrifice Designation =
Rated Flow (W rated) =

Size Inlet =
Size Outlet =
Inlet Rating =
Outlet Rating =
CALCULATION AND REPORT

REV:
UNAN TERMINAL LPG PRESSURIZED PAGES:
TELUK KABUNG PADANG 10 OF 10

PSV SIZING

BLW-PID-10-007-A3 For Outlet 200-T-01


PSV-101
THERMAL EXPANSION ; as governing case
CONVENTIONAL P2/P0 = 0.00 %
LPG
Vapor

TBA lb/hr
257.00 psig = 271.70 psia
95.00 F = 554.67 R
86.00 F = 545.67 R
0.00 psig = 14.70 psia

51.11
0.980
1.580 (Table 7 Api 520)

121.00 %
310.97 psig = 325.67 psia
0.00 %
162.75 psia ; E.q. 3.1 Critical Flow (P2 ≤ Pcf)
1.00
0.975 ; for preeliminary sizing
1.00
350.00 ; see figure 32 (API 520)

TBA in2
TBA in2
; as API 526
TBA

TBA in2 (based on feed requirement)


TBA (based on feed requirement)
TBA lb/hr

0.75 in
1.00 in
300#
150#
REV:
PAGES:
10 OF 10

Flow (P2 ≤ Pcf)


OK
PSV DATASHEET

DOCUMENT NO. PEMBANGUNAN TERMINAL LPG PRESSURIZED REV:


PAGES:
15NO23-DS-10-006 BELAWAN 8 OF 8

OPERATING CONDITIONS
PSV Tag No. : PSV-101
Fluid : Vapour LPG
Phase : Vapour
Scenario : THERMAL EXPANSION
Type PSV : CONVENTIONAL
Flow rate : TBA (lb/h)
Setting Temperature : 95.00 (oF)
Set Pressure, P0 : 257.00 psig
Relieve Pressure, P1 : 310.97 psig
Back Pressure P2 : 0.00 psig
Back Pressure Ratio, P2/P0 : #REF! %
Allowable Overpressure : 121 %
A Orrifice Calculation : TBA inch2

SUMMARY
Relieve Case Relief Load (gal/min) A Orrifice Calculation A Orrifice Effective Type Orrifice Designation (NOTE 1)
THERMAL EXPANSIO TBA TBA TBA
TBA

:
CONNECTION :
Inlet Size : 0.75 inch
Inlet Rating : #REF!
Outlet Size : 1.0 inch
Outlet Rating : #REF!
Calculated Orifice Area : TBA inch2
Selected Effective Orifice Area : TBA inch2
Orifice Designation (Letter) : TBA

Notes :
1. API Standart 526 provides standard effective orifice area in terms of letter designations.
Alfa 0.0024 1/C
Q 31589.97 kcal/h
G 0.529 kg/l
C 0.6307 kcal/kg.C
s3 1
V 227.23852 m3/h

Q 31589.97 kcal/h
qs 353 kcal/h/m2
emisivity 0.95
A 94.2 m2
B 0.00133
H 125412.2
G 0.529
C 0.6307
Q 0.999868
1/F
BTU/h

BTU/lb/F
gpm