MSK-ESPS-TE4020 series high voltage power supply, high voltage power supply for
electrospinning equipment. The output voltage is adjustable, and the front panel of the power
supply has a voltage and current liquid crystal display instrument, which can achieve a linear
and steady rise of the high voltage output. The series of power supplies can also be connected
to a potentiometer for remote control of output voltage and current, and has external voltage
and current display. The high voltage output has overvoltage and short circuit protection, and
safety interlock.
Usual application:
KGC RESOURCES SDN. BHD.(Co. no. 223165-D)
Office: No. 2-2-3, Jalan Setia Prima E, U13/E, Seksyen U13
Setia Alam, 40170 Shah Alam, Selangor Darul Ehsan.
Tel: 03-33412880 Fax: 03-33439880
Email: kgcresources88@yahoo.com
Website: http://www.kgcscientific.com CIDB LICENSE: 1991124-SL054439 MOF LICENSE: 357-02067811
Specifications:
Input 220V ± 10% AC 50/60 HZ
Output The highest voltage output is 50KV
(optional), and the 0V to maximum voltage
is adjustable. Maximum power 100W
(optional)
Voltage control Power board surface: The output voltage can
be set between 0V and the highest voltage by
the potentiometer of the power supply.
Check the outer packaging of the power supply to find out if there are any signs of damage
caused during transportation. If you find it, please inform KGC and do not remove the materials
used for packaging. Check the panel and casing after unpacking to see if there are any signs of
damage.
1.2 Installation
The power supply can be installed in an electrical cabinet or placed on a workbench. The
following shows the dimension of the machine.
KGC RESOURCES SDN. BHD.(Co. no. 223165-D)
Office: No. 2-2-3, Jalan Setia Prima E, U13/E, Seksyen U13
Setia Alam, 40170 Shah Alam, Selangor Darul Ehsan.
Tel: 03-33412880 Fax: 03-33439880
Email: kgcresources88@yahoo.com
Website: http://www.kgcscientific.com CIDB LICENSE: 1991124-SL054439 MOF LICENSE: 357-02067811
High
voltage
Voltage Setting
(close)
adjustment
Power input
JPI Control interface AC 220V
Caution
2. Safety Precautions
Safety precautions
Improper use of high voltage power supplies may threaten personal safety.
2. Do not touch the high voltage connector unless the high voltage power supply is turned off
and the internal capacitance of the load and power supply is completely discharged.
3. Wait 5 minutes after turning off the high voltage power supply, so that the internal
capacitance of the power supply is fully discharged.
4. Do not operate the power supply in a humid environment, nor ground yourself.
5. Maintenance may require the removal of the power supply cover. The operation must be
carried out by qualified personnel to prevent electric shock.
KGC RESOURCES SDN. BHD.(Co. no. 223165-D)
Office: No. 2-2-3, Jalan Setia Prima E, U13/E, Seksyen U13
Setia Alam, 40170 Shah Alam, Selangor Darul Ehsan.
Tel: 03-33412880 Fax: 03-33439880
Email: kgcresources88@yahoo.com
Website: http://www.kgcscientific.com CIDB LICENSE: 1991124-SL054439 MOF LICENSE: 357-02067811
2.1 Steps
1. Check the label on the power supply to make sure the rating of the power supply is the same
as you requested.
2. Good grounding: The outer casing of the high-voltage power supply must be well grounded.
The grounding end of the power supply and the bottom wire can be directly connected by
copper wires. The return line of the high voltage load should be directly connected to the
ground of the power supply. It is not recommended to ground the return line of the high voltage
load and the ground end of the high voltage power supply separately.
4. If the user does not have remote control requirements, you can directly short the 1 pin and
15 pin of the DB15 terminal, and short the 8 pin and 2 pin; if the user has remote control
requirements, it can be connected at the 1 pin and 2 pin of the DB15 terminal. Adjust the
potentiometer to adjust the current and voltage.
5. Connect a switch to the 6-pin and 11-pin of DB5 to control the remote high-voltage switch.
The wiring diagram is shown in Figure 2.1.
7. At this point, you can see that there is a high voltage output; adjusting the external
potentiometer can change the output voltage. With a slow-start high-voltage power supply, the
output will rise slowly and the rise time is about 2-4 seconds.
KGC RESOURCES SDN. BHD.(Co. no. 223165-D)
Office: No. 2-2-3, Jalan Setia Prima E, U13/E, Seksyen U13
Setia Alam, 40170 Shah Alam, Selangor Darul Ehsan.
Tel: 03-33412880 Fax: 03-33439880
Email: kgcresources88@yahoo.com
Website: http://www.kgcscientific.com CIDB LICENSE: 1991124-SL054439 MOF LICENSE: 357-02067811
8. Turn off the voltage power switch or cut off the 220V power input line of the high voltage
power supply to turn off the high voltage power supply completely.
Warning
1. After cutting off the power, do not approach and disconnect the load until the internal power
of the high voltage power supply is completed.
2. When the power supply of the high-voltage power supply is cut off, the voltage indication
of the high-voltage power supply panel does not represent the actual voltage output. At this
time, it is likely that high-voltage static electricity still exists in the high-voltage output and the
load.
3. When operating the high-voltage power supply, be sure to cover the power supply. Do not
operate or repair the internal circuit of the high-voltage power supply. Dangerous or even fatal
voltage may be generated inside the power supply.
2. If the above damage is not avoided, the rise time of the high voltage output must be strictly
controlled to ensure that the high voltage rises slowly. Under normal circumstances, the high
voltage rise time of the high voltage power supply is not less than 2-4 seconds. In order to
achieve a slow rise of the high voltage, high voltage output is required. The control signal is a
ramp-up signal from the starting voltage to the target voltage. The rise time of the signal is not
less than 2 seconds. It is strictly forbidden to use the step-down signal instead! The step-down
signal or the ramp signal that rises too fast will cause overshoot of the high-voltage output, that
is, the high-voltage output exceeds the set value of the high-voltage output at the moment of
high-voltage rise.
2. Remote monitoring
The corresponding output of pin 7 and pin 4 of connector DB15 on the power panel can be
used as the test point of the current of the voltage respectively. The output signal is always 0
to 10V (optional) regardless of whether the polarity of the output is positive or negative.
Positive signal. 0 to 10V represents a nominal output of 0 to 100%. The output resistance of
this output signal is less than 100 ohms.
KGC RESOURCES SDN. BHD.(Co. no. 223165-D)
Office: No. 2-2-3, Jalan Setia Prima E, U13/E, Seksyen U13
Setia Alam, 40170 Shah Alam, Selangor Darul Ehsan.
Tel: 03-33412880 Fax: 03-33439880
Email: kgcresources88@yahoo.com
Website: http://www.kgcscientific.com CIDB LICENSE: 1991124-SL054439 MOF LICENSE: 357-02067811
Chain output
electricity failure
Current control signal
input
OTHERS
1. Maintenance and testing guide
1.1 Regular maintenance: This product does not require regular maintenance.
1.2 Testing:
WARNING: High voltage hazard, testing high voltage power supplies requires professionally
qualified personnel.
3. Warranty terms
3.1 KGC provides a free warranty service for the power products it produces during the
warranty period. The warranty covers products with defects in materials and workmanship or
products that fail due to product defects under normal use.
3.2 The company is not responsible for warranty services other than this
3.3 The company's warranty liability and the purchaser's compensation will be limited to the
purchase price of the product. The repair or replacement of the product during the warranty
period depends on the company's inspection results for the returned product. The customer will
bear the cost of returning the product and returning the product.