Вы находитесь на странице: 1из 1

Company's Name: ABC Consultants Job No.

: ABC/1001
101, Known Street, Known Area, Known City, Pin …. Design by: UVW
Client: Very Important Industries Ltd, Well Known City Date: 30-Aug-19
Project: XYZ Building Page No. C/101
RCDesignCD

SPREADSHEET OF DESIGN OF RECTANGULAR COLUMN SECTION BY LIMIT STATE METHOD


FOR AXIAL COMPRESSIVE LOAD & UNIAXIAL BENDING MOMENT AS PER IS:456-2000

Calculates range of safe loads for a section of Short Column (Cl. 25.1.2 of IS:456-2000), with given Concrete Grade
and type of Steel, and checks adequacy of the section for the given loads.

Column Dimensions:
Breadth, 'b' = 230 mm
Depth, 'D' = 460 mm
Concrete Grade = M 20 2
Yield Strength of Steel, fy = 4500 N/mm2
Concrete Cover to main bars = 38 mm

Details of Reinforcement: b
d2
2 d1
Row1-6 Nos. of bars Bar Dia (mm) Ast (mm ) d1-6 (mm) Y1-6 from CL(mm)
d3
1 2 12 226 44.00 186.00 Mux
d4d5

C.L.
2 2 12 226 98.00 132.00 X X d6
D
3 0 0 0 0.00 0.00 Pu
4 0 0 0 0.00 0.00
5 2 12 226 402.00 -172.00
6 2 12 226 416.00 -186.00
Total Ast = 904 COLUMN SECTION
Percentage of Reinforcement = 0.854 < 4% O.K. (Nos. of bars shown in the
Section are indicative only)
Col. Applied Ultimate Loads Unsupported Moment due to Design Permissible Max. Tensile
Status
Mk. Pu (kN) Mux (kNm) Col. Length(m)Min. Ecc.(kNm) Mux (kNm) Mux (kNm) Stress (N/mm2)
C15C21 978.00 0.00 2.740 19.56 19.56 53.75 64.02 Section O.K.
C20 0.00 0.00 2.740 0.00 0.00 74.02 434.80 Section O.K.
C23 0.00 0.00 3.500 0.00 0.00 74.02 434.80 Section O.K.
C4 0.00 0.00 5.000 0.00 0.00 74.02 434.80 Section O.K.
C5 0.00 0.00 4.000 0.00 0.00 74.02 434.80 Section O.K.
C6 0.00 0.00 5.500 0.00 0.00 74.02 434.80 Section O.K.
C7 0.00 0.00 3.600 0.00 0.00 74.02 434.80 Section O.K.
C8 0.00 0.00 4.200 0.00 0.00 74.02 434.80 Section O.K.
C9 0.00 0.00 3.600 0.00 0.00 74.02 434.80 Section O.K.
C10 0.00 0.00 4.000 0.00 0.00 74.02 434.80 Section O.K.