• Precise time programming for Daily/Weekly/Pulse switching
• 25 ON/OFF programs
• Weekend exclusion (FRI SAT or SAT SUN) and Weekly OFF programming
• LED indication of Relay status
• 12/24 h display formats
• 6 years battery reserve
• Simple Reset & Manual override
• DST Feature Available
EMI/ EMC
Radio Interference Suppression CISPR 14-1 Ed. 5.0 (2005-11) Class B
ESD IEC 61000-4-2 Ed. 1.2 (2001-04) Level II
Electrical Fast Transients IEC 61000-4-4 Ed. 2.0 (2004-07) Level IV
Surges IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV
Voltage Dips & Interruptions IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)
Applications Ideal for Lighting applications like street lighting, Ideal for Siren, School bell application
Advertising Displays, Glowsigns. Also can be used for
Air conditioners / Coolers, Geysers, conveyors,
pumps etc.
ORDERING INFORMATION
Cat. No. Description
67DDT0 110 - 240 VAC (50/60 Hz), 1 C/O (SPDT)
67DDT9 110 - 240 VAC (50/60 Hz), 1 C/O (SPDT)
PROGRAMMING: PROGRAMMING:
To set a program - Press PRG key. To set a program - Press PRG key.
Set 1 ON time, day, then 1 OFF time, day (a) If pulse is common or the same, set pulse
with the help of D+, H+ & M+ keys. before the ON time (b) If pulse time is different
We can set total of 25 ON & 25 OFF programs. for different programs, set the ON time first and
then set different pulse values for each
DST: programme
Press H+ & M+ keys simultaneously to enter the DST mode.
To enable DST, press M+ key once.
To disable DST, press M+ key again.
31
TM
Astronomical Time Switch
• Astronomical Time Switch in 35mm size
• Latitude/Longitude precise to the minute with time zone
• Sunrise/Sunset or Twilight rise/set trigger modes
• Ease of programming & navigation
• DST, Offset, OFF Hours, Weekly OFF features
• 12/24 Hour display format
• 6 years battery reserve
• Easy Manual Override
• Ideal for Outdoor & Street lighting applications
EMI/ EMC
Radio Interference Suppression CISPR 14-1 Ed. 5.0 (2005-11) Class B
ESD IEC 61000-4-2 Ed. 1.2 (2001-04) Level II
Electrical Fast Transients IEC 61000-4-4 Ed. 2.0 (2004-07) Level IV
Surges IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV
Voltage Dips & Interruptions IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)
ORDERING INFORMATION
Cat. No. Description
T2DDT7 110 - 240 VAC (50/60 Hz), 1 C/O (SPDT)
FUNCTIONS OF KEYS:
ESC : Previous Menu / Undo Change
: Menu scroll up / Increase parameter value / View Output OFF time in standby mode
: Menu scroll down / Decrease parameter value / View Output ON time in standby mode
OK : Enter programming mode / selecting a particular parameter to edit / applying & confirming changes
RST : Resets clock & other programs & settings to default
ESC OK
MAN : For mode setting (Manual override)
: Exit programming mode / 12 or 24 Hour clock mode selection in standby mode
RST MAN
32