Вы находитесь на странице: 1из 1

Low Frequency Power Inverter

Solar System
EP3300 TLV Series
Low Frequnecy Pure Sine Wave Power Inverter Specifications
Feature: Model 1012 1024 1512 1524 2012 2024 3024 3048 4024 4048 5048 6048
Rated power(W) 1KW 1.5KW 2KW 3KW 4KW 5KW 6KW
Pure sine wave output
Friendly user interface Power Factor 1
3 Steps charging Wave form Pure sine wave
MFD (multi-function display)
Output voltage RMS 100V/110V/120VAC(200V/220V/240VAC)±10%
Overload and short-circuit protection
Set charging voltage/charging current. Output frequency 50HZ or 60HZ (±0.3HZ)
Battery low voltage shutdown point can be set to 10/10.5/11V Inverter efficiency(peak) >80%
Power-save mode
Set utility priority/ Battery priority 100%<Load<110% (alarm 5min then stop output and fault code 07)
Overload 110%<Load<125% (alarm 60s then stop output and fault code 07)
Set utility input wide/narrow range Load>125% (alarm 10s then stop output and fault code 07)
Inverter voltage can be set to 100/110/120 V
Inverter frequency can be set to 50/60Hz Surge rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA
Set utility charging on/off switch Capable of starting
1P 1P 1.5P 1.5P 2P 3P
electric motor
Inverter
Introduction: Mode Battery voltage 12VDC/24VDC 24VDC/48VDC 48VDC

This inverter is applicable to different markets demands, it matches different voltage AC 120V/240V, also can set output Minimum start voltage 11VDC/22VDC/44VDC
voltage, frequency, charging voltage, charging current, it’s available to work in split phase power environment. (low voltage fault code04)
10/10.5/11V for 12V model
Low battery cut off
20/21/22V for 24V model
LCD Panel Description: Solar System Connection: 40/42/44V for 48v model
Add 0.5V/battery: (low battery alarm one second one time)
(10/10.5/11V) +0.5Vdc for 12V model
Low battery alarm
(20/21/22V) +1Vdc for 24v model
1. Switch ON/OFF: (40/42/44V) +2Vdc for 48v model
POWER ON/OFF Switch
9 Add +1V/battery: (high voltage one second one time/after 30s fault 03)
2. MENU (13.8-14.5V) + 1V for 12V model
PV Panel High voltage alarm
8 3. UP (27.6-29V) + 2V for 24v model
6 7
4. DOWN (55.2-58) + 4V for 48v model
2 5
5. ENTER Save mode Load≤40W(110V)/80W(220V)
3 4
6. AC LED
1 Input waveform Pure sine wave
7. INV LED

8. FAULT Nominal input voltage 220Vac / 230Vac / 240Vac


INVERTE R Generator
9. LCD Max input voltage 270Vac MAX
External Battery Pack Utility
Input frequency 50HZ/60HZ (auto sensing)

AC Output waveform Same as input waveform


Home Appliances
1. Battery -/+ 5. USB Mode Overload protection Breaker + software protection
2. REMOTE PORT 6. AC OUTPUT PROTECT: HOT1 - N output breaker
Output short circuit Breaker+ software protection
3. BTS 7. AC OUTPUT PROTECT: HOT2 - N output breaker

4. AGS 8. AC INPUT PROTECT: Input protect breaker Efficiency(AC mode) >95%® load, full battery)
Transfer time AC TO DC 15ms(max)
6 7 8 3 4 5 2 6 7 8 3 4 5 2
Transfer time DC TO AC 15ms(max)
BatteryVoltage

12VDC
24VDC 12V 30A 45A 60A \ \ \ \
48VDC
US B

24V 20A 25A 30A 40A 60A \ \


USB REMOTE
PORT

Battery
Negative Charge
1 1 Mode 48V \ \ \ 20A 30A 35A 40A
Battery

Min charge current 10A. change by every 5A.


Positive

1-3K Back Panel 4-6K Back Panel


* Product specifications are subject to chaange without further notice.